{"schema":"diagnostic-information-library/2.1.0","catalog_version":"1.3.0","collection":{"id":"medical-diagnostics-2024","title":"Medical diagnostics 2024","short_title":"Diagnostics 2024","evidence_level":"diagnostic_tool","description":"Medical diagnostic tools collected for the 2024 Scientific Reports study.","source_url":"https://www.nature.com/articles/s41598-024-51268-4","source_version":"Mendeley dataset 2","license":"CC BY 4.0","license_url":"https://creativecommons.org/licenses/by/4.0/","redistribution_status":"allowed_with_attribution","default_visible":false,"reference_distribution_eligible":false,"color":"#1b7f79","point_shape":"square","marker_label":"square","available_count":624,"plottable_count":622,"excluded_count":2,"duplicate_group_count":0,"input_sha256":{"normalized_snapshot":"4bcb91516b2623dddffe7e26192f38fa8ac0f9005cd63257259b7a0d9f75ab72","original_source":"dccf4950f7dcb3015c00d30a6be4969fe47643965df86f87ffff90afe420a6f9"},"data_path":"data/library/medical-diagnostics-2024.json"},"records":[{"id":"diagnostics-2024:2:694e55f6cf08","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fluorescent brightener 85 method","test_or_feature":"Fluorescent brightener 85 method","target_condition":"Vaginal Candida infection","citation":"Zhao Y, Yu Z, Yue X. Evaluating the accuracy and diagnostic value of CFW and a new fluorescent reagents, fluorescent brightener 85, for the diagnosis of vulvovaginal candidiasis. J Clin Lab Anal. 2021;35(8):e23891. doi:10.1002/jcla.23893","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"2","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":2,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.88,"specificity":1.0},"tp":68.0,"fp":0.0,"fn":9.0,"tn":33.0,"sample_size":110.0,"observed_prevalence":0.7,"sensitivity":0.8831168831168831,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.7857142857142857,"youden_j":0.883116883116883,"lr_positive":null,"lr_negative":0.11688311688311692,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8812908992306927,"conditional_entropy_bits_observed":0.2862090982263469,"information_bits_observed":0.5950818010043458,"information_fraction_observed":0.6752387906465527,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0c319de12ea1"},{"id":"diagnostics-2024:3:6be51b0a28b5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Calcofluor White method","test_or_feature":"Calcofluor White method","target_condition":"Vaginal Candida infection","citation":"Zhao Y, Yu Z, Yue X. Evaluating the accuracy and diagnostic value of CFW and a new fluorescent reagents, fluorescent brightener 85, for the diagnosis of vulvovaginal candidiasis. J Clin Lab Anal. 2021;35(8):e23891. doi:10.1002/jcla.23892","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"3","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":3,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.92,"specificity":1.0},"tp":71.0,"fp":0.0,"fn":6.0,"tn":33.0,"sample_size":110.0,"observed_prevalence":0.7,"sensitivity":0.922077922077922,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.8461538461538461,"youden_j":0.922077922077922,"lr_positive":null,"lr_negative":0.07792207792207795,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8812908992306927,"conditional_entropy_bits_observed":0.21959914174974351,"information_bits_observed":0.6616917574809492,"information_fraction_observed":0.7508210490526582,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a9f77ee705ad"},{"id":"diagnostics-2024:4:47e7215ba165","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"KOH prep","test_or_feature":"KOH prep","target_condition":"Vaginal Candida infection","citation":"Zhao Y, Yu Z, Yue X. Evaluating the accuracy and diagnostic value of CFW and a new fluorescent reagents, fluorescent brightener 85, for the diagnosis of vulvovaginal candidiasis. J Clin Lab Anal. 2021;35(8):e23891. doi:10.1002/jcla.23891","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"4","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":4,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.91,"specificity":1.0},"tp":70.0,"fp":0.0,"fn":7.0,"tn":33.0,"sample_size":110.0,"observed_prevalence":0.7,"sensitivity":0.9090909090909091,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.825,"youden_j":0.9090909090909092,"lr_positive":null,"lr_negative":0.09090909090909094,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8812908992306927,"conditional_entropy_bits_observed":0.24327848547511186,"information_bits_observed":0.6380124137555808,"information_fraction_observed":0.7239521187754492,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ac33999cf3ba"},{"id":"diagnostics-2024:5:3a2addac2b5c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PCR","test_or_feature":"PCR","target_condition":"Mycoplasma pneumonia","citation":"Zhang L, Zong ZY, Liu YB, Ye H, Lv XJ. PCR versus serology for diagnosing Mycoplasma pneumoniae infection: a systematic review & meta-analysis. Indian J Med Res. 2011;134(3):270-280.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"5","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":5,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.6,"specificity":0.96},"tp":297.0,"fp":79.0,"fn":198.0,"tn":1757.0,"sample_size":2331.0,"observed_prevalence":0.21235521235521235,"sensitivity":0.6,"specificity":0.9569716775599129,"ppv_observed":0.7898936170212766,"npv_observed":0.8987212276214833,"youden_j":0.556971677559913,"lr_positive":13.944303797468356,"lr_negative":0.41798520204894707,"diagnostic_odds_ratio":33.360759493670884,"baseline_entropy_bits_observed":0.7459605888215293,"conditional_entropy_bits_observed":0.5163704939361479,"information_bits_observed":0.2295900948853814,"information_fraction_observed":0.3077777811936265,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ba4c62653fb4"},{"id":"diagnostics-2024:6:2b4ec269acc4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Phdurkan's test","test_or_feature":"Phdurkan's test","target_condition":"Carpal tunnel syndrome","citation":"Zhang D et al. Accuracy of Provocative Tests for Carpal Tunnel Syndrome. Journal of Hand Surgery Global Online. 2020;2(3):121-125. doi:10.1016/j.jhsg.2020.03.005","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"6","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":6,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.84,"specificity":0.11},"tp":64.0,"fp":8.0,"fn":12.0,"tn":1.0,"sample_size":85.0,"observed_prevalence":0.8941176470588236,"sensitivity":0.8421052631578947,"specificity":0.1111111111111111,"ppv_observed":0.8888888888888888,"npv_observed":0.07692307692307693,"youden_j":-0.04678362573099415,"lr_positive":0.9473684210526315,"lr_negative":1.4210526315789478,"diagnostic_odds_ratio":0.6666666666666666,"baseline_entropy_bits_observed":0.48736957102366274,"conditional_entropy_bits_observed":0.4861266638944332,"information_bits_observed":0.0012429071292295313,"information_fraction_observed":0.002550235392453719,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bc875abc52fb"},{"id":"diagnostics-2024:7:9369c9df738b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Durkan's test","test_or_feature":"Durkan's test","target_condition":"Carpal tunnel syndrome","citation":"Zhang D et al. Accuracy of Provocative Tests for Carpal Tunnel Syndrome. Journal of Hand Surgery Global Online. 2020;2(3):121-125. doi:10.1016/j.jhsg.2020.03.004","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"7","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":7,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.71,"specificity":0.22},"tp":54.0,"fp":7.0,"fn":22.0,"tn":2.0,"sample_size":85.0,"observed_prevalence":0.8941176470588236,"sensitivity":0.7105263157894737,"specificity":0.2222222222222222,"ppv_observed":0.8852459016393442,"npv_observed":0.08333333333333333,"youden_j":-0.06725146198830412,"lr_positive":0.9135338345864661,"lr_negative":1.3026315789473686,"diagnostic_odds_ratio":0.7012987012987013,"baseline_entropy_bits_observed":0.48736957102366274,"conditional_entropy_bits_observed":0.48577849914579707,"information_bits_observed":0.0015910718778656685,"information_fraction_observed":0.0032646106208965987,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"75cbf15cdec3"},{"id":"diagnostics-2024:8:9f3f8ebf0ee4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Phalen's test","test_or_feature":"Phalen's test","target_condition":"Carpal tunnel syndrome","citation":"Zhang D et al. Accuracy of Provocative Tests for Carpal Tunnel Syndrome. Journal of Hand Surgery Global Online. 2020;2(3):121-125. doi:10.1016/j.jhsg.2020.03.003","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"8","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":8,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.5,"specificity":0.33},"tp":38.0,"fp":6.0,"fn":38.0,"tn":3.0,"sample_size":85.0,"observed_prevalence":0.8941176470588236,"sensitivity":0.5,"specificity":0.3333333333333333,"ppv_observed":0.8636363636363636,"npv_observed":0.07317073170731707,"youden_j":-0.16666666666666674,"lr_positive":0.7499999999999999,"lr_negative":1.5,"diagnostic_odds_ratio":0.5,"baseline_entropy_bits_observed":0.48736957102366274,"conditional_entropy_bits_observed":0.4796172927197601,"information_bits_observed":0.007752278303902627,"information_fraction_observed":0.015906365035510676,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1be93aeccd3d"},{"id":"diagnostics-2024:9:0ebda5fb2f5b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Tinel's sign","test_or_feature":"Tinel's sign","target_condition":"Carpal tunnel syndrome","citation":"Zhang D et al. Accuracy of Provocative Tests for Carpal Tunnel Syndrome. Journal of Hand Surgery Global Online. 2020;2(3):121-125. doi:10.1016/j.jhsg.2020.03.002","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"9","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":9,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.47,"specificity":0.56},"tp":36.0,"fp":4.0,"fn":40.0,"tn":5.0,"sample_size":85.0,"observed_prevalence":0.8941176470588236,"sensitivity":0.47368421052631576,"specificity":0.5555555555555556,"ppv_observed":0.9,"npv_observed":0.1111111111111111,"youden_j":0.029239766081871288,"lr_positive":1.0657894736842106,"lr_negative":0.9473684210526316,"diagnostic_odds_ratio":1.125,"baseline_entropy_bits_observed":0.48736957102366274,"conditional_entropy_bits_observed":0.4871346918644154,"information_bits_observed":0.0002348791592473587,"information_fraction_observed":0.0004819323429528489,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"38936f331d36"},{"id":"diagnostics-2024:10:ab68de39fae7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Cell-free DNA","test_or_feature":"Cell-free DNA","target_condition":"Tuberculosis","citation":"Yu G, Shen Y, Ye B, Shi Y. Diagnostic accuracy of Mycobacterium tuberculosis cell-free DNA for tuberculosis: A systematic review and meta-analysis. PLoS One. 2021;16(6):e0253658. Published 2021 Jun 23. doi:10.1371/journal.pone.0253658","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"10","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":10,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.58,"specificity":0.97},"tp":627.0,"fp":21.0,"fn":458.0,"tn":597.0,"sample_size":1703.0,"observed_prevalence":0.637110980622431,"sensitivity":0.5778801843317972,"specificity":0.9660194174757282,"ppv_observed":0.9675925925925926,"npv_observed":0.5658767772511848,"youden_j":0.5438996018075253,"lr_positive":17.006188281764327,"lr_negative":0.436968251395225,"diagnostic_odds_ratio":38.91859014348098,"baseline_entropy_bits_observed":0.9450551909645368,"conditional_entropy_bits_observed":0.6902227892382637,"information_bits_observed":0.2548324017262731,"information_fraction_observed":0.26964816887169046,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"18794ffc8a70"},{"id":"diagnostics-2024:11:605bf0b74830","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum procalcitonin","test_or_feature":"Serum procalcitonin","target_condition":"Spontaneous bacterial peritonitis","citation":"Yang Y, Li L, Qu C, et al. Diagnostic Accuracy of Serum Procalcitonin for Spontaneous Bacterial Peritonitis Due to End-stage Liver Disease: A Meta-analysis. Medicine (Baltimore). 2015;94(49):e2077. doi:10.1097/MD.0000000000002077","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"11","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":11,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.83,"specificity":0.86},"tp":281.0,"fp":57.0,"fn":58.0,"tn":346.0,"sample_size":742.0,"observed_prevalence":0.4568733153638814,"sensitivity":0.8289085545722714,"specificity":0.858560794044665,"ppv_observed":0.8313609467455622,"npv_observed":0.8564356435643564,"youden_j":0.6874693486169363,"lr_positive":5.860528903379392,"lr_negative":0.19927703036813474,"diagnostic_odds_ratio":29.408953418027828,"baseline_entropy_bits_observed":0.9946267573485776,"conditional_entropy_bits_observed":0.6213233116252386,"information_bits_observed":0.37330344572333907,"information_fraction_observed":0.37532013186380714,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8bda5897d456"},{"id":"diagnostics-2024:12:c2f269c1005a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CT angiogram","test_or_feature":"CT angiogram","target_condition":"Acute GI bleeding","citation":"Wu LM, Xu JR, Yin Y, Qu XH. Usefulness of CT angiography in diagnosing acute gastrointestinal bleeding: a meta-analysis. World J Gastroenterol. 2010;16(31):3957-3963. doi:10.3748/wjg.v16.i31.3966","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"12","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":12,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.81,"specificity":0.98},"tp":801.0,"fp":654.0,"fn":185.0,"tn":27125.0,"sample_size":28765.0,"observed_prevalence":0.03427776812098036,"sensitivity":0.8123732251521298,"specificity":0.9764570358904209,"ppv_observed":0.5505154639175258,"npv_observed":0.9932259245697547,"youden_j":0.7888302610425506,"lr_positive":34.50598749464995,"lr_negative":0.1921505687925893,"diagnostic_odds_ratio":179.57785767418795,"baseline_entropy_bits_observed":0.2154105581814873,"conditional_entropy_bits_observed":0.10579964386234128,"information_bits_observed":0.10961091431914602,"information_fraction_observed":0.5088465265792442,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bcb45c1048a3"},{"id":"diagnostics-2024:13:fa62a087f815","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Nephrolithiasis","citation":"Wong C, Teitge B, Ross M, Young P, Robertson HL, Lang E. The Accuracy and Prognostic Value of Point-of-care Ultrasound for Nephrolithiasis in the Emergency Department: A Systematic Review and Meta-analysis. Acad Emerg Med. 2018;25(6):684-698. doi:10.1111/acem.13388","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"13","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":13,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.65,"specificity":0.75},"tp":770.0,"fp":342.0,"fn":413.0,"tn":1025.0,"sample_size":2550.0,"observed_prevalence":0.463921568627451,"sensitivity":0.650887573964497,"specificity":0.7498171177761521,"ppv_observed":0.6924460431654677,"npv_observed":0.7127955493741307,"youden_j":0.40070469174064915,"lr_positive":2.6016471158171557,"lr_negative":0.4655967672102757,"diagnostic_odds_ratio":5.587768857171176,"baseline_entropy_bits_observed":0.9962409567840815,"conditional_entropy_bits_observed":0.8760923329576749,"information_bits_observed":0.12014862382640668,"information_fraction_observed":0.12060197185051776,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e1bbc15eff76"},{"id":"diagnostics-2024:14:e8a5ae6c5497","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Intramedullary spinal cord tumor","citation":"Won, Y.I., Choi, Y., Yuh, W.T. et al. Validity of magnetic resonance imaging (MRI) in the primary spinal cord tumors in routine clinical setting. Sci Rep 12, 10151 (2022). https://doi.org/10.1038/s41598-022-13881-z","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"14","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":14,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.93,"specificity":0.97},"tp":154.0,"fp":20.0,"fn":11.0,"tn":635.0,"sample_size":820.0,"observed_prevalence":0.20121951219512196,"sensitivity":0.9333333333333333,"specificity":0.9694656488549618,"ppv_observed":0.8850574712643678,"npv_observed":0.9829721362229102,"youden_j":0.9027989821882951,"lr_positive":30.566666666666617,"lr_negative":0.06876640419947505,"diagnostic_odds_ratio":444.5,"baseline_entropy_bits_observed":0.7243604244946997,"conditional_entropy_bits_observed":0.20721680986144078,"information_bits_observed":0.517143614633259,"information_fraction_observed":0.7139313484637274,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1bed493f7a60"},{"id":"diagnostics-2024:15:afbc1962ca4e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Extradural spinal cord tumor","citation":"Won, Y.I., Choi, Y., Yuh, W.T. et al. Validity of magnetic resonance imaging (MRI) in the primary spinal cord tumors in routine clinical setting. Sci Rep 12, 10151 (2022). https://doi.org/10.1038/s41598-022-13881-z","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"15","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":15,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.88,"specificity":0.98},"tp":138.0,"fp":15.0,"fn":18.0,"tn":649.0,"sample_size":820.0,"observed_prevalence":0.1902439024390244,"sensitivity":0.8846153846153846,"specificity":0.9774096385542169,"ppv_observed":0.9019607843137255,"npv_observed":0.9730134932533733,"youden_j":0.8620250231696014,"lr_positive":39.15897435897445,"lr_negative":0.11805144008533842,"diagnostic_odds_ratio":331.7111111111111,"baseline_entropy_bits_observed":0.7019814061434109,"conditional_entropy_bits_observed":0.23198127420143455,"information_bits_observed":0.4700001319419763,"information_fraction_observed":0.6695335913868321,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"36c65d0f57b6"},{"id":"diagnostics-2024:16:c2b24eadb707","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Intradural extramedullary spinal cord tumor","citation":"Won, Y.I., Choi, Y., Yuh, W.T. et al. Validity of magnetic resonance imaging (MRI) in the primary spinal cord tumors in routine clinical setting. Sci Rep 12, 10151 (2022). https://doi.org/10.1038/s41598-022-13881-z","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"16","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":16,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.93,"specificity":0.92},"tp":425.0,"fp":29.0,"fn":31.0,"tn":335.0,"sample_size":820.0,"observed_prevalence":0.5560975609756098,"sensitivity":0.9320175438596491,"specificity":0.9203296703296703,"ppv_observed":0.9361233480176211,"npv_observed":0.9153005464480874,"youden_j":0.8523472141893194,"lr_positive":11.698427102238346,"lr_negative":0.07386750458235146,"diagnostic_odds_ratio":158.37041156840934,"baseline_entropy_bits_observed":0.9909007147597781,"conditional_entropy_bits_observed":0.3765137082744755,"information_bits_observed":0.6143870064853026,"information_fraction_observed":0.620028825626841,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4d32fc49a046"},{"id":"diagnostics-2024:17:7c08d9a7b51f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"At least 2 diagnostic elements","test_or_feature":"At least 2 diagnostic elements","target_condition":"Neuromyelitis optica","citation":"Wingerchuk DM, Lennon VA, Pittock SJ, Lucchinetti CF, Weinshenker BG. Revised diagnostic criteria for neuromyelitis optica. Neurology. 2006;66(10):1485-1489. doi:10.1212/01.wnl.0000216139.44259.75","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"17","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":17,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.99,"specificity":0.91},"tp":95.0,"fp":3.0,"fn":1.0,"tn":30.0,"sample_size":129.0,"observed_prevalence":0.7441860465116279,"sensitivity":0.9895833333333334,"specificity":0.9090909090909091,"ppv_observed":0.9693877551020408,"npv_observed":0.967741935483871,"youden_j":0.8986742424242424,"lr_positive":10.885416666666664,"lr_negative":0.011458333333333293,"diagnostic_odds_ratio":950.0,"baseline_entropy_bits_observed":0.8203636429576731,"conditional_entropy_bits_observed":0.1994090091738332,"information_bits_observed":0.6209546337838399,"information_fraction_observed":0.7569260767640799,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cb83709163aa"},{"id":"diagnostics-2024:18:3a40a9f8b5f6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NMO IgG seropositivity","test_or_feature":"NMO IgG seropositivity","target_condition":"Neuromyelitis optica","citation":"Wingerchuk DM, Lennon VA, Pittock SJ, Lucchinetti CF, Weinshenker BG. Revised diagnostic criteria for neuromyelitis optica. Neurology. 2006;66(10):1485-1489. doi:10.1212/01.wnl.0000216139.44259.74","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"18","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":18,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.76,"specificity":0.94},"tp":73.0,"fp":2.0,"fn":23.0,"tn":31.0,"sample_size":129.0,"observed_prevalence":0.7441860465116279,"sensitivity":0.7604166666666666,"specificity":0.9393939393939394,"ppv_observed":0.9733333333333334,"npv_observed":0.5740740740740741,"youden_j":0.699810606060606,"lr_positive":12.54687500000001,"lr_negative":0.2550403225806452,"diagnostic_odds_ratio":49.19565217391305,"baseline_entropy_bits_observed":0.8203636429576731,"conditional_entropy_bits_observed":0.515086228639323,"information_bits_observed":0.3052774143183501,"information_fraction_observed":0.37212450471077374,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5dd1c4cf583a"},{"id":"diagnostics-2024:19:722a55825b93","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Auditory brainstem response","test_or_feature":"Auditory brainstem response","target_condition":"Acoustic neuroma","citation":"Wilson DF, Hodgson RS, Gustafson MF, Hogue S, Mills L. The sensitivity of auditory brainstem response testing in small acoustic neuromas. Laryngoscope. 1992;102(9):961-964. doi:10.1288/00005537-199209000-00001","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"19","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":19,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1992,"source_reported":{"sensitivity":0.82,"specificity":1.0},"tp":28.0,"fp":0.0,"fn":6.0,"tn":6.0,"sample_size":40.0,"observed_prevalence":0.85,"sensitivity":0.8235294117647058,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.5,"youden_j":0.8235294117647058,"lr_positive":null,"lr_negative":0.17647058823529416,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.6098403047164005,"conditional_entropy_bits_observed":0.3,"information_bits_observed":0.3098403047164005,"information_fraction_observed":0.5080679356876688,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0d31588ee8ef"},{"id":"diagnostics-2024:20:b475f14d5fb6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Reported family history of prostate cancer","test_or_feature":"Reported family history of prostate cancer","target_condition":"Family history of prostate cancer","citation":"Wilson BJ, Qureshi N, Santaguida P, et al. Systematic review: family history in risk assessment for common diseases. Ann Intern Med. 2009;151(12):878-885. doi:10.7326/0003-4819-151-12-200912150-00180","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"20","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":20,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.79,"specificity":0.99},"tp":46.0,"fp":7.0,"fn":12.0,"tn":557.0,"sample_size":622.0,"observed_prevalence":0.0932475884244373,"sensitivity":0.7931034482758621,"specificity":0.9875886524822695,"ppv_observed":0.8679245283018868,"npv_observed":0.9789103690685413,"youden_j":0.7806921007581316,"lr_positive":63.901477832512086,"lr_negative":0.20949668792174825,"diagnostic_odds_ratio":305.0238095238095,"baseline_entropy_bits_observed":0.4472179397924695,"conditional_entropy_bits_observed":0.18292734045694092,"information_bits_observed":0.26429059933552856,"information_fraction_observed":0.5909660052058109,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f1df0753251f"},{"id":"diagnostics-2024:21:6acafe7bbb33","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Reported family history of ovarian cancer","test_or_feature":"Reported family history of ovarian cancer","target_condition":"Family history of ovarian cancer","citation":"Wilson BJ, Qureshi N, Santaguida P, et al. Systematic review: family history in risk assessment for common diseases. Ann Intern Med. 2009;151(12):878-885. doi:10.7326/0003-4819-151-12-200912150-00179","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"21","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":21,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.83,"specificity":0.99},"tp":35.0,"fp":11.0,"fn":7.0,"tn":1017.0,"sample_size":1070.0,"observed_prevalence":0.03925233644859813,"sensitivity":0.8333333333333334,"specificity":0.9892996108949417,"ppv_observed":0.7608695652173914,"npv_observed":0.9931640625,"youden_j":0.8226329442282752,"lr_positive":77.87878787878816,"lr_negative":0.16846935431006224,"diagnostic_odds_ratio":462.27272727272725,"baseline_entropy_bits_observed":0.23885361556139287,"conditional_entropy_bits_observed":0.09057755222715672,"information_bits_observed":0.14827606333423615,"information_fraction_observed":0.6207821597581158,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0bd36a5cf39d"},{"id":"diagnostics-2024:22:0ac4bab4096c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Reported family history of colorectal cancer","test_or_feature":"Reported family history of colorectal cancer","target_condition":"Family history of colorectal cancer","citation":"Wilson BJ, Qureshi N, Santaguida P, et al. Systematic review: family history in risk assessment for common diseases. Ann Intern Med. 2009;151(12):878-885. doi:10.7326/0003-4819-151-12-200912150-00178","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"22","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":22,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.86,"specificity":0.92},"tp":70.0,"fp":20.0,"fn":11.0,"tn":219.0,"sample_size":320.0,"observed_prevalence":0.253125,"sensitivity":0.8641975308641975,"specificity":0.9163179916317992,"ppv_observed":0.7777777777777778,"npv_observed":0.9521739130434783,"youden_j":0.7805155224959965,"lr_positive":10.32716049382716,"lr_negative":0.1482045211116749,"diagnostic_odds_ratio":69.68181818181819,"baseline_entropy_bits_observed":0.8161936656965703,"conditional_entropy_bits_observed":0.4140906357666089,"information_bits_observed":0.40210302992996133,"information_fraction_observed":0.4926563961836086,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e58532a17cbc"},{"id":"diagnostics-2024:23:aeb86d9b37f4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Reported family history of breast cancer","test_or_feature":"Reported family history of breast cancer","target_condition":"Family history of breast cancer","citation":"Wilson BJ, Qureshi N, Santaguida P, et al. Systematic review: family history in risk assessment for common diseases. Ann Intern Med. 2009;151(12):878-885. doi:10.7326/0003-4819-151-12-200912150-00177","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"23","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":23,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.9,"specificity":0.99},"tp":54.0,"fp":5.0,"fn":6.0,"tn":364.0,"sample_size":429.0,"observed_prevalence":0.13986013986013987,"sensitivity":0.9,"specificity":0.986449864498645,"ppv_observed":0.9152542372881356,"npv_observed":0.9837837837837838,"youden_j":0.8864498644986449,"lr_positive":66.42000000000019,"lr_negative":0.10137362637362635,"diagnostic_odds_ratio":655.2,"baseline_entropy_bits_observed":0.5838724133205311,"conditional_entropy_bits_observed":0.16076105052556564,"information_bits_observed":0.4231113627949654,"information_fraction_observed":0.724664075818715,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"389335af96d8"},{"id":"diagnostics-2024:24:545717cf24cf","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Supine AP CXR","test_or_feature":"Supine AP CXR","target_condition":"Pneumothorax","citation":"Wilkerson RG, Stone MB. Sensitivity of bedside ultrasound and supine anteroposterior chest radiographs for the identification of pneumothorax after blunt trauma. Acad Emerg Med. 2010;17(1):11-17. doi:10.1111/j.1553-2712.2009.00628.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"24","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":24,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.56,"specificity":1.0},"tp":91.0,"fp":0.0,"fn":72.0,"tn":443.0,"sample_size":606.0,"observed_prevalence":0.26897689768976896,"sensitivity":0.558282208588957,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.8601941747572815,"youden_j":0.5582822085889569,"lr_positive":null,"lr_negative":0.44171779141104295,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8399927148763524,"conditional_entropy_bits_observed":0.49607422546638524,"information_bits_observed":0.34391848940996717,"information_fraction_observed":0.4094303240005983,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e35548383233"},{"id":"diagnostics-2024:25:bb51f9e70232","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Chest US","test_or_feature":"Chest US","target_condition":"Pneumothorax","citation":"Wilkerson RG, Stone MB. Sensitivity of bedside ultrasound and supine anteroposterior chest radiographs for the identification of pneumothorax after blunt trauma. Acad Emerg Med. 2010;17(1):11-17. doi:10.1111/j.1553-2712.2009.00628.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"25","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":25,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.95,"specificity":0.99},"tp":156.0,"fp":5.0,"fn":8.0,"tn":437.0,"sample_size":606.0,"observed_prevalence":0.2706270627062706,"sensitivity":0.9512195121951219,"specificity":0.9886877828054299,"ppv_observed":0.968944099378882,"npv_observed":0.9820224719101124,"youden_j":0.9399072950005518,"lr_positive":84.08780487804907,"lr_negative":0.04933861695596365,"diagnostic_odds_ratio":1704.3,"baseline_entropy_bits_observed":0.842362993360115,"conditional_entropy_bits_observed":0.14845496962486382,"information_bits_observed":0.6939080237352512,"information_fraction_observed":0.8237636615152223,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f3756218c412"},{"id":"diagnostics-2024:26:3c606fb745a7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Gallbladder US","test_or_feature":"Gallbladder US","target_condition":"Gallstone","citation":"Wertz JR, Lopez JM, Olson D, Thompson WM. Comparing the Diagnostic Accuracy of Ultrasound and CT in Evaluating Acute Cholecystitis. AJR Am J Roentgenol. 2018;211(2):W92-W97. doi:10.2214/AJR.17.18885","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"26","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":26,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.93,"specificity":0.97},"tp":64.0,"fp":8.0,"fn":5.0,"tn":265.0,"sample_size":342.0,"observed_prevalence":0.20175438596491227,"sensitivity":0.927536231884058,"specificity":0.9706959706959707,"ppv_observed":0.8888888888888888,"npv_observed":0.9814814814814815,"youden_j":0.8982322025800287,"lr_positive":31.65217391304347,"lr_negative":0.07465135356849875,"diagnostic_odds_ratio":424.0,"baseline_entropy_bits_observed":0.7254230207665604,"conditional_entropy_bits_observed":0.2109804246454246,"information_bits_observed":0.5144425961211359,"information_fraction_observed":0.7091622148653626,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4cc3056e9306"},{"id":"diagnostics-2024:27:f16a711c4473","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal CT","test_or_feature":"Abdominal CT","target_condition":"Cholecystitis","citation":"Wertz JR, Lopez JM, Olson D, Thompson WM. Comparing the Diagnostic Accuracy of Ultrasound and CT in Evaluating Acute Cholecystitis. AJR Am J Roentgenol. 2018;211(2):W92-W97. doi:10.2214/AJR.17.18884","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"27","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":27,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.85,"specificity":1.0},"tp":41.0,"fp":0.0,"fn":7.0,"tn":60.0,"sample_size":108.0,"observed_prevalence":0.4444444444444444,"sensitivity":0.8541666666666666,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.8955223880597015,"youden_j":0.8541666666666665,"lr_positive":null,"lr_negative":0.14583333333333337,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9910760598382222,"conditional_entropy_bits_observed":0.299657921942189,"information_bits_observed":0.6914181378960332,"information_fraction_observed":0.6976438700465598,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3f40460a6fe0","condition_context_id":"condition:cholecystitis"},{"id":"diagnostics-2024:28:994db279bd9a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Gallbladder US","test_or_feature":"Gallbladder US","target_condition":"Cholecystitis","citation":"Wertz JR, Lopez JM, Olson D, Thompson WM. Comparing the Diagnostic Accuracy of Ultrasound and CT in Evaluating Acute Cholecystitis. AJR Am J Roentgenol. 2018;211(2):W92-W97. doi:10.2214/AJR.17.18884","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"28","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":28,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.68,"specificity":1.0},"tp":38.0,"fp":0.0,"fn":18.0,"tn":60.0,"sample_size":116.0,"observed_prevalence":0.4827586206896552,"sensitivity":0.6785714285714286,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.7692307692307693,"youden_j":0.6785714285714286,"lr_positive":null,"lr_negative":0.3214285714285714,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9991421039919088,"conditional_entropy_bits_observed":0.5240455802481263,"information_bits_observed":0.47509652374378253,"information_fraction_observed":0.4755044571193748,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"515263d71332","condition_context_id":"condition:cholecystitis"},{"id":"diagnostics-2024:29:00b55def6ab9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"N-terminal pro-brain natriuretic peptide","test_or_feature":"N-terminal pro-brain natriuretic peptide","target_condition":"Kawasaki disease","citation":"Wen JX, Bai X, Niu Y, Hu ZD. Diagnostic accuracy of N-terminal pro-brain natriuretic peptide for Kawasaki disease: An updated systematic review and meta-analysis. Int J Clin Pract. 2021;75(11):e14538. doi:10.1111/ijcp.14538","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"29","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":29,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.8,"specificity":0.81},"tp":1738.0,"fp":363.0,"fn":435.0,"tn":1546.0,"sample_size":4082.0,"observed_prevalence":0.5323370896619304,"sensitivity":0.7998159226875288,"specificity":0.8098480880041907,"ppv_observed":0.8272251308900523,"npv_observed":0.7804139323573952,"youden_j":0.6096640106917195,"lr_positive":4.206194480469677,"lr_negative":0.24718719507730114,"diagnostic_odds_ratio":17.016231278300243,"baseline_entropy_bits_observed":0.9969806771368239,"conditional_entropy_bits_observed":0.7103099123106917,"information_bits_observed":0.2866707648261322,"information_fraction_observed":0.2875389377148279,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3f7570e616c3"},{"id":"diagnostics-2024:30:a9fd273ca51a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum procalcitonin","test_or_feature":"Serum procalcitonin","target_condition":"Bacterial meningitis","citation":"Wei TT, Hu ZD, Qin BD, et al. Diagnostic Accuracy of Procalcitonin in Bacterial Meningitis Versus Nonbacterial Meningitis: A Systematic Review and Meta-Analysis. Medicine (Baltimore). 2016;95(11):e3079. doi:10.1097/MD.0000000000003080","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"30","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":30,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.93,"specificity":0.91},"tp":569.0,"fp":109.0,"fn":40.0,"tn":1083.0,"sample_size":1801.0,"observed_prevalence":0.3381454747362576,"sensitivity":0.9343185550082101,"specificity":0.9085570469798657,"ppv_observed":0.8392330383480826,"npv_observed":0.9643811219946572,"youden_j":0.8428756019880759,"lr_positive":10.217501996053082,"lr_negative":0.07229204287184995,"diagnostic_odds_ratio":141.33646788990825,"baseline_entropy_bits_observed":0.9230329862306218,"conditional_entropy_bits_observed":0.37780119026311676,"information_bits_observed":0.545231795967505,"information_fraction_observed":0.5906958950557784,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e88bbc94f500","condition_context_id":"condition:bacterial_meningitis"},{"id":"diagnostics-2024:31:0cecac1f3f20","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CSF procalcitonin","test_or_feature":"CSF procalcitonin","target_condition":"Bacterial meningitis","citation":"Wei TT, Hu ZD, Qin BD, et al. Diagnostic Accuracy of Procalcitonin in Bacterial Meningitis Versus Nonbacterial Meningitis: A Systematic Review and Meta-Analysis. Medicine (Baltimore). 2016;95(11):e3079. doi:10.1097/MD.0000000000003079","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"31","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":31,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.76,"specificity":0.8},"tp":117.0,"fp":54.0,"fn":36.0,"tn":216.0,"sample_size":423.0,"observed_prevalence":0.3617021276595745,"sensitivity":0.7647058823529411,"specificity":0.8,"ppv_observed":0.6842105263157895,"npv_observed":0.8571428571428571,"youden_j":0.5647058823529412,"lr_positive":3.8235294117647065,"lr_negative":0.2941176470588236,"diagnostic_odds_ratio":13.0,"baseline_entropy_bits_observed":0.9440870182837794,"conditional_entropy_bits_observed":0.7162121109696202,"information_bits_observed":0.22787490731415916,"information_fraction_observed":0.24137066064990964,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1b3144751bb0","condition_context_id":"condition:bacterial_meningitis"},{"id":"diagnostics-2024:32:0b22b3838620","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Real-time quaking-induced conversion","test_or_feature":"Real-time quaking-induced conversion","target_condition":"Creutzfeldt-Jakob disease","citation":"Watson N, Hermann P, Ladogana A, et al. Validation of Revised International Creutzfeldt-Jakob Disease Surveillance Network Diagnostic Criteria for Sporadic Creutzfeldt-Jakob Disease. JAMA Netw Open. 2022;5(1):e2146319. Published 2022 Jan 4. doi:10.1001/jamanetworkopen.2021.46322","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"32","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":32,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.92,"specificity":1.0},"tp":251.0,"fp":0.0,"fn":23.0,"tn":77.0,"sample_size":351.0,"observed_prevalence":0.7806267806267806,"sensitivity":0.916058394160584,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.77,"youden_j":0.916058394160584,"lr_positive":null,"lr_negative":0.08394160583941601,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.7590213674137011,"conditional_entropy_bits_observed":0.22165564203605062,"information_bits_observed":0.5373657253776505,"information_fraction_observed":0.7079718021755793,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2132d87bba8d"},{"id":"diagnostics-2024:33:862535db78da","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CSF 14-3-3","test_or_feature":"CSF 14-3-3","target_condition":"Creutzfeldt-Jakob disease","citation":"Watson N, Hermann P, Ladogana A, et al. Validation of Revised International Creutzfeldt-Jakob Disease Surveillance Network Diagnostic Criteria for Sporadic Creutzfeldt-Jakob Disease. JAMA Netw Open. 2022;5(1):e2146319. Published 2022 Jan 4. doi:10.1001/jamanetworkopen.2021.46321","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"33","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":33,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.72,"specificity":0.46},"tp":326.0,"fp":67.0,"fn":127.0,"tn":56.0,"sample_size":576.0,"observed_prevalence":0.7864583333333334,"sensitivity":0.7196467991169978,"specificity":0.45528455284552843,"ppv_observed":0.8295165394402035,"npv_observed":0.30601092896174864,"youden_j":0.17493135196252618,"lr_positive":1.3211426312147871,"lr_negative":0.6157757805108799,"diagnostic_odds_ratio":2.145493007403925,"baseline_entropy_bits_observed":0.7481981891199668,"conditional_entropy_bits_observed":0.7317888678790263,"information_bits_observed":0.016409321240940522,"information_fraction_observed":0.02193178422449969,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"59558a81d766"},{"id":"diagnostics-2024:34:4c821151c767","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Creutzfeldt-Jakob disease","citation":"Watson N, Hermann P, Ladogana A, et al. Validation of Revised International Creutzfeldt-Jakob Disease Surveillance Network Diagnostic Criteria for Sporadic Creutzfeldt-Jakob Disease. JAMA Netw Open. 2022;5(1):e2146319. Published 2022 Jan 4. doi:10.1001/jamanetworkopen.2021.46320","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"34","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":34,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.87,"specificity":0.82},"tp":395.0,"fp":20.0,"fn":60.0,"tn":91.0,"sample_size":566.0,"observed_prevalence":0.803886925795053,"sensitivity":0.8681318681318682,"specificity":0.8198198198198198,"ppv_observed":0.9518072289156626,"npv_observed":0.6026490066225165,"youden_j":0.687951687951688,"lr_positive":4.818131868131867,"lr_negative":0.16085013887211688,"diagnostic_odds_ratio":29.954166666666666,"baseline_entropy_bits_observed":0.7140857947240757,"conditional_entropy_bits_observed":0.46294052318465134,"information_bits_observed":0.2511452715394244,"information_fraction_observed":0.35170181705752523,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9e4df21cd691"},{"id":"diagnostics-2024:35:fe9928c90b9f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"EEG","test_or_feature":"EEG","target_condition":"Creutzfeldt-Jakob disease","citation":"Watson N, Hermann P, Ladogana A, et al. Validation of Revised International Creutzfeldt-Jakob Disease Surveillance Network Diagnostic Criteria for Sporadic Creutzfeldt-Jakob Disease. JAMA Netw Open. 2022;5(1):e2146319. Published 2022 Jan 4. doi:10.1001/jamanetworkopen.2021.46319","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"35","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":35,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.46,"specificity":0.88},"tp":207.0,"fp":14.0,"fn":241.0,"tn":104.0,"sample_size":566.0,"observed_prevalence":0.7915194346289752,"sensitivity":0.46205357142857145,"specificity":0.8813559322033898,"ppv_observed":0.9366515837104072,"npv_observed":0.30144927536231886,"youden_j":0.3434095036319613,"lr_positive":3.8944515306122445,"lr_negative":0.610362293956044,"diagnostic_odds_ratio":6.380557202133966,"baseline_entropy_bits_observed":0.7385683401702147,"conditional_entropy_bits_observed":0.6712469366092819,"information_bits_observed":0.06732140356093275,"information_fraction_observed":0.09115121769966131,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"960b49ed570a"},{"id":"diagnostics-2024:36:48994af84444","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Monofilament test","test_or_feature":"Monofilament test","target_condition":"Diabetic neuropathy","citation":"Wang F, Zhang J, Yu J, et al. Diagnostic Accuracy of Monofilament Tests for Detecting Diabetic Peripheral Neuropathy: A Systematic Review and Meta-Analysis. J Diabetes Res. 2017;2017:8787261. doi:10.1155/2017/8787261","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"36","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":36,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.69,"specificity":0.79},"tp":512.0,"fp":145.0,"fn":231.0,"tn":544.0,"sample_size":1432.0,"observed_prevalence":0.5188547486033519,"sensitivity":0.6890982503364738,"specificity":0.7895500725689405,"ppv_observed":0.7792998477929984,"npv_observed":0.7019354838709677,"youden_j":0.47864832290541415,"lr_positive":3.274404789529865,"lr_negative":0.3937707822025176,"diagnostic_odds_ratio":8.315509777578743,"baseline_entropy_bits_observed":0.9989739961235905,"conditional_entropy_bits_observed":0.825017818783206,"information_bits_observed":0.1739561773403845,"information_fraction_observed":0.17413484036161345,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e58d51ec174d"},{"id":"diagnostics-2024:37:066ce9d5761d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Bedside ocular ultrasonography","test_or_feature":"Bedside ocular ultrasonography","target_condition":"Retinal detachment","citation":"Vrablik ME, Snead GR, Minnigan HJ, Kirschner JM, Emmett TW, Seupaul RA. The diagnostic accuracy of bedside ocular ultrasonography for the diagnosis of retinal detachment: a systematic review and meta-analysis. Ann Emerg Med. 2015;65(2):199-203.e1. doi:10.1016/j.annemergmed.2014.02.020","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"37","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":37,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.98,"specificity":0.93},"tp":55.0,"fp":10.0,"fn":1.0,"tn":135.0,"sample_size":201.0,"observed_prevalence":0.27860696517412936,"sensitivity":0.9821428571428571,"specificity":0.9310344827586207,"ppv_observed":0.8461538461538461,"npv_observed":0.9926470588235294,"youden_j":0.9131773399014778,"lr_positive":14.241071428571422,"lr_negative":0.01917989417989423,"diagnostic_odds_ratio":742.5,"baseline_entropy_bits_observed":0.8535457524356882,"conditional_entropy_bits_observed":0.24270986797165983,"information_bits_observed":0.6108358844640284,"information_fraction_observed":0.7156451575336646,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f90234f5560b"},{"id":"diagnostics-2024:38:d9c9d87bcc9d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"HIST1H4A-IgG","test_or_feature":"HIST1H4A-IgG","target_condition":"SLE","citation":"Vordenbäumen S, Böhmer P, Brinks R, et al. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus. Rheumatology (Oxford). 2018;57(3):533-537. doi:10.1093/rheumatology/kex467","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"38","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":38,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.95,"specificity":0.93},"tp":146.0,"fp":6.0,"fn":7.0,"tn":75.0,"sample_size":234.0,"observed_prevalence":0.6538461538461539,"sensitivity":0.954248366013072,"specificity":0.9259259259259259,"ppv_observed":0.9605263157894737,"npv_observed":0.9146341463414634,"youden_j":0.8801742919389979,"lr_positive":12.882352941176473,"lr_negative":0.049411764705882294,"diagnostic_odds_ratio":260.7142857142857,"baseline_entropy_bits_observed":0.9305861291319928,"conditional_entropy_bits_observed":0.3032786306824963,"information_bits_observed":0.6273074984494965,"information_fraction_observed":0.6740993432113797,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"088dc17d9e2e"},{"id":"diagnostics-2024:39:a3087d1fedb3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Anti-Smith antibodies","test_or_feature":"Anti-Smith antibodies","target_condition":"SLE","citation":"Vordenbäumen S, Böhmer P, Brinks R, et al. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus. Rheumatology (Oxford). 2018;57(3):533-537. doi:10.1093/rheumatology/kex466","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"39","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":39,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.82,"specificity":0.91},"tp":125.0,"fp":7.0,"fn":28.0,"tn":74.0,"sample_size":234.0,"observed_prevalence":0.6538461538461539,"sensitivity":0.8169934640522876,"specificity":0.9135802469135802,"ppv_observed":0.946969696969697,"npv_observed":0.7254901960784313,"youden_j":0.7305737109658677,"lr_positive":9.453781512605037,"lr_negative":0.2003179650238474,"diagnostic_odds_ratio":47.19387755102041,"baseline_entropy_bits_observed":0.9305861291319928,"conditional_entropy_bits_observed":0.5383222295943978,"information_bits_observed":0.392263899537595,"information_fraction_observed":0.42152347564376486,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fc2c59d9d160"},{"id":"diagnostics-2024:40:6e613f456f4f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"U1RNP antibodies","test_or_feature":"U1RNP antibodies","target_condition":"SLE","citation":"Vordenbäumen S, Böhmer P, Brinks R, et al. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus. Rheumatology (Oxford). 2018;57(3):533-537. doi:10.1093/rheumatology/kex465","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"40","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":40,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.95,"specificity":0.77},"tp":145.0,"fp":19.0,"fn":8.0,"tn":62.0,"sample_size":234.0,"observed_prevalence":0.6538461538461539,"sensitivity":0.9477124183006536,"specificity":0.7654320987654321,"ppv_observed":0.8841463414634146,"npv_observed":0.8857142857142857,"youden_j":0.7131445170660857,"lr_positive":4.0402476780185745,"lr_negative":0.06831119544592036,"diagnostic_odds_ratio":59.14473684210526,"baseline_entropy_bits_observed":0.9305861291319928,"conditional_entropy_bits_observed":0.5159432815894593,"information_bits_observed":0.41464284754253344,"information_fraction_observed":0.4455717042863006,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1b99dcf838ba"},{"id":"diagnostics-2024:41:2ad30e0991e6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"SSB antibodies","test_or_feature":"SSB antibodies","target_condition":"SLE","citation":"Vordenbäumen S, Böhmer P, Brinks R, et al. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus. Rheumatology (Oxford). 2018;57(3):533-537. doi:10.1093/rheumatology/kex464","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"41","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":41,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.99,"specificity":0.73},"tp":151.0,"fp":22.0,"fn":2.0,"tn":59.0,"sample_size":234.0,"observed_prevalence":0.6538461538461539,"sensitivity":0.9869281045751634,"specificity":0.7283950617283951,"ppv_observed":0.8728323699421965,"npv_observed":0.9672131147540983,"youden_j":0.7153231663035586,"lr_positive":3.633689839572193,"lr_negative":0.017946161515453574,"diagnostic_odds_ratio":202.47727272727272,"baseline_entropy_bits_observed":0.9305861291319928,"conditional_entropy_bits_observed":0.4606115803933049,"information_bits_observed":0.4699745487386879,"information_fraction_observed":0.5050306833791496,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d36547c6cb26"},{"id":"diagnostics-2024:42:5f35fb34f20f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"SSA52 antibodies","test_or_feature":"SSA52 antibodies","target_condition":"SLE","citation":"Vordenbäumen S, Böhmer P, Brinks R, et al. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus. Rheumatology (Oxford). 2018;57(3):533-537. doi:10.1093/rheumatology/kex463","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"42","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":42,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.92,"specificity":0.78},"tp":141.0,"fp":18.0,"fn":12.0,"tn":63.0,"sample_size":234.0,"observed_prevalence":0.6538461538461539,"sensitivity":0.9215686274509803,"specificity":0.7777777777777778,"ppv_observed":0.8867924528301887,"npv_observed":0.84,"youden_j":0.6993464052287581,"lr_positive":4.147058823529412,"lr_negative":0.10084033613445385,"diagnostic_odds_ratio":41.125,"baseline_entropy_bits_observed":0.9305861291319928,"conditional_entropy_bits_observed":0.5495137426242027,"information_bits_observed":0.3810723865077901,"information_fraction_observed":0.40949717020093196,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b84e53ccfc57"},{"id":"diagnostics-2024:43:7f8654ef360d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"SSA60 antibodies","test_or_feature":"SSA60 antibodies","target_condition":"SLE","citation":"Vordenbäumen S, Böhmer P, Brinks R, et al. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus. Rheumatology (Oxford). 2018;57(3):533-537. doi:10.1093/rheumatology/kex462","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"43","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":43,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.96,"specificity":0.81},"tp":147.0,"fp":15.0,"fn":6.0,"tn":66.0,"sample_size":234.0,"observed_prevalence":0.6538461538461539,"sensitivity":0.9607843137254902,"specificity":0.8148148148148148,"ppv_observed":0.9074074074074074,"npv_observed":0.9166666666666666,"youden_j":0.775599128540305,"lr_positive":5.1882352941176455,"lr_negative":0.048128342245989275,"diagnostic_odds_ratio":107.8,"baseline_entropy_bits_observed":0.9305861291319928,"conditional_entropy_bits_observed":0.4354500857440063,"information_bits_observed":0.4951360433879865,"information_fraction_observed":0.5320690131603684,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0d6f14c4018c"},{"id":"diagnostics-2024:44:8d4e5fb116b4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CAGE, cut down","test_or_feature":"CAGE, cut down","target_condition":"AUD (DSM4)","citation":"Volk RJ, Cantor SB, Steinbauer JR, Cass AR. Item bias in the CAGE screening test for alcohol use disorders. J Gen Intern Med. 1997;12(12):763-769. doi:10.1046/j.1525-1497.1997.07162.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"44","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":44,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.63,"specificity":0.84},"tp":129.0,"fp":180.0,"fn":76.0,"tn":948.0,"sample_size":1333.0,"observed_prevalence":0.15378844711177794,"sensitivity":0.6292682926829268,"specificity":0.8404255319148937,"ppv_observed":0.4174757281553398,"npv_observed":0.92578125,"youden_j":0.4696938245978206,"lr_positive":3.9434146341463427,"lr_negative":0.44112380364309967,"diagnostic_odds_ratio":8.939473684210526,"baseline_entropy_bits_observed":0.6192402504569735,"conditional_entropy_bits_observed":0.520276902742872,"information_bits_observed":0.09896334771410153,"information_fraction_observed":0.15981413940884934,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3728809fee3d"},{"id":"diagnostics-2024:45:aa7b92c2f63a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CAGE, guilty","test_or_feature":"CAGE, guilty","target_condition":"AUD (DSM4)","citation":"Volk RJ, Cantor SB, Steinbauer JR, Cass AR. Item bias in the CAGE screening test for alcohol use disorders. J Gen Intern Med. 1997;12(12):763-769. doi:10.1046/j.1525-1497.1997.07162.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"45","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":45,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.37,"specificity":0.9},"tp":76.0,"fp":113.0,"fn":129.0,"tn":1015.0,"sample_size":1333.0,"observed_prevalence":0.15378844711177794,"sensitivity":0.37073170731707317,"specificity":0.899822695035461,"ppv_observed":0.4021164021164021,"npv_observed":0.8872377622377622,"youden_j":0.27055440235253414,"lr_positive":3.700755450032376,"lr_negative":0.6993247627057552,"diagnostic_odds_ratio":5.291898195787885,"baseline_entropy_bits_observed":0.6192402504569735,"conditional_entropy_bits_observed":0.573977963596703,"information_bits_observed":0.04526228686027056,"information_fraction_observed":0.07309325714352205,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"053bd8004b91"},{"id":"diagnostics-2024:46:454d432d826b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CAGE, eye-opener","test_or_feature":"CAGE, eye-opener","target_condition":"AUD (DSM4)","citation":"Volk RJ, Cantor SB, Steinbauer JR, Cass AR. Item bias in the CAGE screening test for alcohol use disorders. J Gen Intern Med. 1997;12(12):763-769. doi:10.1046/j.1525-1497.1997.07162.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"46","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":46,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.21,"specificity":0.95},"tp":43.0,"fp":56.0,"fn":162.0,"tn":1072.0,"sample_size":1333.0,"observed_prevalence":0.15378844711177794,"sensitivity":0.2097560975609756,"specificity":0.950354609929078,"ppv_observed":0.43434343434343436,"npv_observed":0.8687196110210696,"youden_j":0.16011070749005363,"lr_positive":4.22508710801394,"lr_negative":0.8315253003276302,"diagnostic_odds_ratio":5.081128747795415,"baseline_entropy_bits_observed":0.6192402504569735,"conditional_entropy_bits_observed":0.5926211963486914,"information_bits_observed":0.026619054108282136,"information_fraction_observed":0.04298663416765687,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ba487a20016c"},{"id":"diagnostics-2024:47:59821ed071ab","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CAGE, annoyed","test_or_feature":"CAGE, annoyed","target_condition":"AUD (DSM4)","citation":"Volk RJ, Cantor SB, Steinbauer JR, Cass AR. Item bias in the CAGE screening test for alcohol use disorders. J Gen Intern Med. 1997;12(12):763-769. doi:10.1046/j.1525-1497.1997.07162.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"47","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":47,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.24,"specificity":0.93},"tp":49.0,"fp":79.0,"fn":156.0,"tn":1049.0,"sample_size":1333.0,"observed_prevalence":0.15378844711177794,"sensitivity":0.23902439024390243,"specificity":0.9299645390070922,"ppv_observed":0.3828125,"npv_observed":0.870539419087137,"youden_j":0.1689889292509945,"lr_positive":3.4129052176597714,"lr_negative":0.8182845450952126,"diagnostic_odds_ratio":4.170804933463161,"baseline_entropy_bits_observed":0.6192402504569735,"conditional_entropy_bits_observed":0.5947552026576703,"information_bits_observed":0.02448504779930316,"information_fraction_observed":0.03954046556443031,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d0a4e35e7103"},{"id":"diagnostics-2024:48:a7896660cc3f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"2-dimensional echocardiography","test_or_feature":"2-dimensional echocardiography","target_condition":"Left ventricular thrombus","citation":"Visser CA, Kan G, David GK, Lie KI, Durrer D. Two dimensional echocardiography in the diagnosis of left ventricular thrombus. A prospective study of 67 patients with anatomic validation. Chest. 1983;83(2):228-232. doi:10.1378/chest.83.2.228","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"48","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":48,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1983,"source_reported":{"sensitivity":0.92,"specificity":0.88},"tp":24.0,"fp":5.0,"fn":2.0,"tn":36.0,"sample_size":67.0,"observed_prevalence":0.3880597014925373,"sensitivity":0.9230769230769231,"specificity":0.8780487804878049,"ppv_observed":0.8275862068965517,"npv_observed":0.9473684210526315,"youden_j":0.8011257035647281,"lr_positive":7.56923076923077,"lr_negative":0.08760683760683755,"diagnostic_odds_ratio":86.4,"baseline_entropy_bits_observed":0.9635359835770287,"conditional_entropy_bits_observed":0.4557709526251945,"information_bits_observed":0.5077650309518342,"information_fraction_observed":0.5269808700520021,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f67001c7b59e"},{"id":"diagnostics-2024:49:3c46c28f5ed6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Physically hazardous recurrent drinking & drinking more/longer than intended","test_or_feature":"Physically hazardous recurrent drinking & drinking more/longer than intended","target_condition":"AUD (DSM4)","citation":"Vinson DC, Kruse RL, Seale JP. Simplifying alcohol assessment: two questions to identify alcohol use disorders. Alcohol Clin Exp Res. 2007;31(8):1392-1398. doi:10.1111/j.1530-0277.2007.00440.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"49","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":49,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2007,"source_reported":{"sensitivity":0.94,"specificity":0.82},"tp":118.0,"fp":90.0,"fn":7.0,"tn":408.0,"sample_size":623.0,"observed_prevalence":0.20064205457463885,"sensitivity":0.944,"specificity":0.8192771084337349,"ppv_observed":0.5673076923076923,"npv_observed":0.983132530120482,"youden_j":0.7632771084337349,"lr_positive":5.223466666666666,"lr_negative":0.06835294117647066,"diagnostic_odds_ratio":76.41904761904762,"baseline_entropy_bits_observed":0.7232103470004622,"conditional_entropy_bits_observed":0.41173884797341076,"information_bits_observed":0.3114714990270514,"information_fraction_observed":0.43067898616065065,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c213fc3212c6"},{"id":"diagnostics-2024:50:930de38f39d2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Immulite TSI assay","test_or_feature":"Immulite TSI assay","target_condition":"Hyperthyroidism","citation":"Villalta, D., D’Aurizio, F., Da Re, M. et al. Diagnostic accuracy of a new fluoroenzyme immunoassay for the detection of TSH receptor autoantibodies in Graves’ disease. Autoimmun Highlights 9, 3 (2018). https://doi.org/10.1007/s13317-018-0102-6","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"50","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":50,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":1.0,"specificity":0.98},"tp":319.0,"fp":2.0,"fn":0.0,"tn":118.0,"sample_size":439.0,"observed_prevalence":0.7266514806378133,"sensitivity":1.0,"specificity":0.9833333333333333,"ppv_observed":0.9937694704049844,"npv_observed":1.0,"youden_j":0.9833333333333334,"lr_positive":59.999999999999815,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8462286209612908,"conditional_entropy_bits_observed":0.039929935251175344,"information_bits_observed":0.8062986857101154,"information_fraction_observed":0.9528142463370995,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"dc3bbae3723d"},{"id":"diagnostics-2024:51:ec94b21160dc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TRAK RIA TSI assay","test_or_feature":"TRAK RIA TSI assay","target_condition":"Hyperthyroidism","citation":"Villalta, D., D’Aurizio, F., Da Re, M. et al. Diagnostic accuracy of a new fluoroenzyme immunoassay for the detection of TSH receptor autoantibodies in Graves’ disease. Autoimmun Highlights 9, 3 (2018). https://doi.org/10.1007/s13317-018-0102-5","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"51","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":51,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":1.0,"specificity":0.98},"tp":319.0,"fp":2.0,"fn":0.0,"tn":118.0,"sample_size":439.0,"observed_prevalence":0.7266514806378133,"sensitivity":1.0,"specificity":0.9833333333333333,"ppv_observed":0.9937694704049844,"npv_observed":1.0,"youden_j":0.9833333333333334,"lr_positive":59.999999999999815,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8462286209612908,"conditional_entropy_bits_observed":0.039929935251175344,"information_bits_observed":0.8062986857101154,"information_fraction_observed":0.9528142463370995,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b9d945be48b6"},{"id":"diagnostics-2024:52:f4952f2bc3e6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ELiA anti-TSH-R assay","test_or_feature":"ELiA anti-TSH-R assay","target_condition":"Hyperthyroidism","citation":"Villalta, D., D’Aurizio, F., Da Re, M. et al. Diagnostic accuracy of a new fluoroenzyme immunoassay for the detection of TSH receptor autoantibodies in Graves’ disease. Autoimmun Highlights 9, 3 (2018). https://doi.org/10.1007/s13317-018-0102-4","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"52","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":52,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.95,"specificity":1.0},"tp":302.0,"fp":0.0,"fn":17.0,"tn":120.0,"sample_size":439.0,"observed_prevalence":0.7266514806378133,"sensitivity":0.9467084639498433,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.8759124087591241,"youden_j":0.9467084639498433,"lr_positive":null,"lr_negative":0.053291536050156685,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8462286209612908,"conditional_entropy_bits_observed":0.16883065054969054,"information_bits_observed":0.6773979704116002,"information_fraction_observed":0.8004904982321397,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"11a1a2fc1c48"},{"id":"diagnostics-2024:53:c858ad8b210a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CT angiography","test_or_feature":"CT angiography","target_condition":"Renal artery stenosis","citation":"Vasbinder GB, Nelemans PJ, Kessels AG, et al. Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis. Ann Intern Med. 2004;141(9):674-682. doi:10.7326/0003-4819-141-9-200411020-00007","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"53","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":53,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.63,"specificity":0.92},"tp":45.0,"fp":23.0,"fn":26.0,"tn":262.0,"sample_size":356.0,"observed_prevalence":0.199438202247191,"sensitivity":0.6338028169014085,"specificity":0.9192982456140351,"ppv_observed":0.6617647058823529,"npv_observed":0.9097222222222222,"youden_j":0.5531010625154436,"lr_positive":7.853643600734841,"lr_negative":0.3983442640576282,"diagnostic_odds_ratio":19.71571906354515,"baseline_entropy_bits_observed":0.7208030754476279,"conditional_entropy_bits_observed":0.5301750006229832,"information_bits_observed":0.19062807482464472,"information_fraction_observed":0.26446623400748154,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4d965a90f1ff"},{"id":"diagnostics-2024:54:f707c02d0f89","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MR angiography","test_or_feature":"MR angiography","target_condition":"Renal artery stenosis","citation":"Vasbinder GB, Nelemans PJ, Kessels AG, et al. Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis. Ann Intern Med. 2004;141(9):674-682. doi:10.7326/0003-4819-141-9-200411020-00007","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"54","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":54,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.62,"specificity":0.84},"tp":44.0,"fp":46.0,"fn":27.0,"tn":239.0,"sample_size":356.0,"observed_prevalence":0.199438202247191,"sensitivity":0.6197183098591549,"specificity":0.8385964912280702,"ppv_observed":0.4888888888888889,"npv_observed":0.8984962406015038,"youden_j":0.4583148010872251,"lr_positive":3.8395590936925914,"lr_negative":0.4534739819671165,"diagnostic_odds_ratio":8.466988727858293,"baseline_entropy_bits_observed":0.7208030754476279,"conditional_entropy_bits_observed":0.6066964484508734,"information_bits_observed":0.11410662699675445,"information_fraction_observed":0.15830485590796456,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8a65f1876902"},{"id":"diagnostics-2024:55:58afec36a58b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Synovial fluid neutrophil-to-lymphocyte ratio","test_or_feature":"Synovial fluid neutrophil-to-lymphocyte ratio","target_condition":"Septic arthritis","citation":"Varady NH, Schwab P-E, Kheir MM, Dilley JE, Bedair H, Chen AF. Synovial fluid and serum neutrophil-to-lymphocyte ratio. Journal of Bone and Joint Surgery. 2022;104(17):1516-1522. doi:10.2106/jbjs.21.01279","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"55","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":55,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.78,"specificity":0.81},"tp":183.0,"fp":69.0,"fn":52.0,"tn":294.0,"sample_size":598.0,"observed_prevalence":0.39297658862876256,"sensitivity":0.7787234042553192,"specificity":0.8099173553719008,"ppv_observed":0.7261904761904762,"npv_observed":0.8497109826589595,"youden_j":0.5886407596272201,"lr_positive":4.096762257169287,"lr_negative":0.27320885801128963,"diagnostic_odds_ratio":14.994983277591974,"baseline_entropy_bits_observed":0.9666936050756427,"conditional_entropy_bits_observed":0.7101473492230507,"information_bits_observed":0.25654625585259205,"information_fraction_observed":0.2653852828916951,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1203f9eec124"},{"id":"diagnostics-2024:56:3fdc14de1b01","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Synovial fluid PMN%","test_or_feature":"Synovial fluid PMN%","target_condition":"Septic arthritis","citation":"Varady NH, Schwab P-E, Kheir MM, Dilley JE, Bedair H, Chen AF. Synovial fluid and serum neutrophil-to-lymphocyte ratio. Journal of Bone and Joint Surgery. 2022;104(17):1516-1522. doi:10.2106/jbjs.21.01279","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"56","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":56,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.65,"specificity":0.78},"tp":153.0,"fp":80.0,"fn":82.0,"tn":283.0,"sample_size":598.0,"observed_prevalence":0.39297658862876256,"sensitivity":0.6510638297872341,"specificity":0.7796143250688705,"ppv_observed":0.6566523605150214,"npv_observed":0.7753424657534247,"youden_j":0.4306781548561047,"lr_positive":2.9542021276595745,"lr_negative":0.4475753702729117,"diagnostic_odds_ratio":6.600457317073171,"baseline_entropy_bits_observed":0.9666936050756427,"conditional_entropy_bits_observed":0.8306905613820579,"information_bits_observed":0.13600304369358485,"information_fraction_observed":0.1406888831988733,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d608fd6740bb"},{"id":"diagnostics-2024:57:7376792be6ba","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Synovial fluid WBC","test_or_feature":"Synovial fluid WBC","target_condition":"Septic arthritis","citation":"Varady NH, Schwab P-E, Kheir MM, Dilley JE, Bedair H, Chen AF. Synovial fluid and serum neutrophil-to-lymphocyte ratio. Journal of Bone and Joint Surgery. 2022;104(17):1516-1522. doi:10.2106/jbjs.21.01279","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"57","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":57,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.56,"specificity":0.8},"tp":132.0,"fp":73.0,"fn":103.0,"tn":290.0,"sample_size":598.0,"observed_prevalence":0.39297658862876256,"sensitivity":0.5617021276595745,"specificity":0.7988980716253443,"ppv_observed":0.6439024390243903,"npv_observed":0.7379134860050891,"youden_j":0.3606001992849188,"lr_positive":2.7931215389099386,"lr_negative":0.5486280264123258,"diagnostic_odds_ratio":5.091102540231414,"baseline_entropy_bits_observed":0.9666936050756427,"conditional_entropy_bits_observed":0.867422267271721,"information_bits_observed":0.09927133780392172,"information_fraction_observed":0.10269162564301214,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3df99136fce7"},{"id":"diagnostics-2024:58:a3987d7665e0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Emergency room evaluation","test_or_feature":"Emergency room evaluation","target_condition":"Vasovagal syncope","citation":"van Wijnen, V.K., Gans, R.O.B., Wieling, W. et al. Diagnostic accuracy of evaluation of suspected syncope in the emergency department: usual practice vs. ESC guidelines. BMC Emerg Med 20, 59 (2020). https://doi.org/10.1186/s12873-020-00344-9","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"58","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":58,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.75,"specificity":0.82},"tp":47.0,"fp":7.0,"fn":16.0,"tn":31.0,"sample_size":101.0,"observed_prevalence":0.6237623762376238,"sensitivity":0.746031746031746,"specificity":0.8157894736842105,"ppv_observed":0.8703703703703703,"npv_observed":0.6595744680851063,"youden_j":0.5618212197159567,"lr_positive":4.049886621315192,"lr_negative":0.31131592421915,"diagnostic_odds_ratio":13.008928571428571,"baseline_entropy_bits_observed":0.9553413768968345,"conditional_entropy_bits_observed":0.7280431192121876,"information_bits_observed":0.22729825768464695,"information_fraction_observed":0.237923597973913,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f017f81041c3"},{"id":"diagnostics-2024:59:9298544f0171","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PCR of dried blood","test_or_feature":"PCR of dried blood","target_condition":"Neonatal HIV","citation":"van Schalkwyk, C., Maritz, J., van Zyl, G.U. et al. Pooled PCR testing of dried blood spots for infant HIV diagnosis is cost efficient and accurate. BMC Infect Dis 19, 136 (2019). https://doi.org/10.1186/s12879-019-3767-z","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"59","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":59,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.99,"specificity":0.99},"tp":165.0,"fp":1.0,"fn":2.0,"tn":66.0,"sample_size":234.0,"observed_prevalence":0.7136752136752137,"sensitivity":0.9880239520958084,"specificity":0.9850746268656716,"ppv_observed":0.9939759036144579,"npv_observed":0.9705882352941176,"youden_j":0.9730985789614799,"lr_positive":66.19760479041898,"lr_negative":0.012157503175467231,"diagnostic_odds_ratio":5445.0,"baseline_entropy_bits_observed":0.8639262896524751,"conditional_entropy_bits_observed":0.09329419478801289,"information_bits_observed":0.7706320948644622,"information_fraction_observed":0.8920113950629496,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"67c4eb55973d"},{"id":"diagnostics-2024:60:30fbd167c73f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Assay (male urine)","test_or_feature":"Assay (male urine)","target_condition":"Gonorrhea","citation":"Van Der Pol B, Taylor SN, Mena L, et al. Evaluation of the Performance of a Point-of-Care Test for Chlamydia and Gonorrhea. JAMA Netw Open. 2020;3(5):e204819. doi:10.1001/jamanetworkopen.2020.4822","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"60","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":60,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.97,"specificity":1.0},"tp":72.0,"fp":0.0,"fn":2.0,"tn":848.0,"sample_size":922.0,"observed_prevalence":0.08026030368763558,"sensitivity":0.972972972972973,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9976470588235294,"youden_j":0.972972972972973,"lr_positive":null,"lr_negative":0.027027027027026973,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.4030957229389528,"conditional_entropy_bits_observed":0.022065760197084106,"information_bits_observed":0.3810299627418687,"information_fraction_observed":0.9452592549575976,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"673b230cf95c"},{"id":"diagnostics-2024:61:31fe07e2f39a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Assay (vaginal swab)","test_or_feature":"Assay (vaginal swab)","target_condition":"Gonorrhea","citation":"Van Der Pol B, Taylor SN, Mena L, et al. Evaluation of the Performance of a Point-of-Care Test for Chlamydia and Gonorrhea. JAMA Netw Open. 2020;3(5):e204819. doi:10.1001/jamanetworkopen.2020.4821","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"61","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":61,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":45.0,"fp":1.0,"fn":0.0,"tn":1476.0,"sample_size":1522.0,"observed_prevalence":0.02956636005256242,"sensitivity":1.0,"specificity":0.999322951929587,"ppv_observed":0.9782608695652174,"npv_observed":1.0,"youden_j":0.999322951929587,"lr_positive":1476.9999999999502,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.19221249177264593,"conditional_entropy_bits_observed":0.004566662709452843,"information_bits_observed":0.1876458290631931,"information_fraction_observed":0.9762415924826863,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"28f9ccfbf1c9"},{"id":"diagnostics-2024:62:0db9f0770a55","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Assay (male urine)","test_or_feature":"Assay (male urine)","target_condition":"Chlamydia","citation":"Van Der Pol B, Taylor SN, Mena L, et al. Evaluation of the Performance of a Point-of-Care Test for Chlamydia and Gonorrhea. JAMA Netw Open. 2020;3(5):e204819. doi:10.1001/jamanetworkopen.2020.4820","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"62","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":62,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.93,"specificity":0.99},"tp":111.0,"fp":6.0,"fn":9.0,"tn":796.0,"sample_size":922.0,"observed_prevalence":0.1301518438177874,"sensitivity":0.925,"specificity":0.9925187032418953,"ppv_observed":0.9487179487179487,"npv_observed":0.9888198757763975,"youden_j":0.9175187032418952,"lr_positive":123.64166666666704,"lr_negative":0.07556532663316579,"diagnostic_odds_ratio":1636.2222222222222,"baseline_entropy_bits_observed":0.557854470266791,"conditional_entropy_bits_observed":0.11431715436327303,"information_bits_observed":0.44353731590351797,"information_fraction_observed":0.7950771026203277,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6eaf30eb88e6"},{"id":"diagnostics-2024:63:8f4601219691","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Assay (vaginal swab)","test_or_feature":"Assay (vaginal swab)","target_condition":"Chlamydia","citation":"Van Der Pol B, Taylor SN, Mena L, et al. Evaluation of the Performance of a Point-of-Care Test for Chlamydia and Gonorrhea. JAMA Netw Open. 2020;3(5):e204819. doi:10.1001/jamanetworkopen.2020.4819","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"63","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":63,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.96,"specificity":0.99},"tp":124.0,"fp":13.0,"fn":5.0,"tn":1381.0,"sample_size":1523.0,"observed_prevalence":0.08470124753775443,"sensitivity":0.9612403100775194,"specificity":0.990674318507891,"ppv_observed":0.9051094890510949,"npv_observed":0.9963924963924964,"youden_j":0.9519146285854103,"lr_positive":103.07453786523602,"lr_negative":0.039124553042677715,"diagnostic_odds_ratio":2634.523076923077,"baseline_entropy_bits_observed":0.4185314733092347,"conditional_entropy_bits_observed":0.07208056598106276,"information_bits_observed":0.3464509073281719,"information_fraction_observed":0.8277774299477698,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"049dd3e42dc0"},{"id":"diagnostics-2024:64:c5ef5b746d57","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ultrasonography","test_or_feature":"Ultrasonography","target_condition":"Pyloric stenosis","citation":"van den Bunder FA, Derikx JP, Kiblawi R, van Rijn RR, Dingemann J. Diagnostic accuracy of palpation and ultrasonography for diagnosing infantile hypertrophic pyloric stenosis: a systematic review and meta-analysis. Br J Radiol. 2022;95(1139):20211251. doi:10.1259/bjr.20211252","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"64","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":64,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.98,"specificity":0.99},"tp":583.0,"fp":2.0,"fn":14.0,"tn":363.0,"sample_size":962.0,"observed_prevalence":0.6205821205821206,"sensitivity":0.9765494137353434,"specificity":0.9945205479452055,"ppv_observed":0.9965811965811966,"npv_observed":0.9628647214854111,"youden_j":0.9710699616805489,"lr_positive":178.2202680067009,"lr_negative":0.023579790596693243,"diagnostic_odds_ratio":7558.178571428572,"baseline_entropy_bits_observed":0.9576298509008296,"conditional_entropy_bits_observed":0.10976916308787071,"information_bits_observed":0.8478606878129589,"information_fraction_observed":0.8853741213428002,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8a2388d390f0"},{"id":"diagnostics-2024:65:281e18f35b00","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Palpation of olive","test_or_feature":"Palpation of olive","target_condition":"Pyloric stenosis","citation":"van den Bunder FA, Derikx JP, Kiblawi R, van Rijn RR, Dingemann J. Diagnostic accuracy of palpation and ultrasonography for diagnosing infantile hypertrophic pyloric stenosis: a systematic review and meta-analysis. Br J Radiol. 2022;95(1139):20211251. doi:10.1259/bjr.20211251","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"65","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":65,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.81,"specificity":0.98},"tp":582.0,"fp":3.0,"fn":136.0,"tn":191.0,"sample_size":912.0,"observed_prevalence":0.7872807017543859,"sensitivity":0.8105849582172702,"specificity":0.9845360824742269,"ppv_observed":0.9948717948717949,"npv_observed":0.5840978593272171,"youden_j":0.795121040691497,"lr_positive":52.41782729805033,"lr_negative":0.19239014715104494,"diagnostic_odds_ratio":272.45588235294116,"baseline_entropy_bits_observed":0.746648527685297,"conditional_entropy_bits_observed":0.38095846355659285,"information_bits_observed":0.36569006412870414,"information_fraction_observed":0.48977537699349477,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9b7f9f7ec96b"},{"id":"diagnostics-2024:66:7d4c9376b394","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pelvic US","test_or_feature":"Pelvic US","target_condition":"Septic pelvic thrombophlebitis","citation":"Twickler DM, Setiawan AT, Evans RS, et al. Imaging of puerperal septic thrombophlebitis: prospective comparison of MR imaging, CT, and sonography. AJR Am J Roentgenol. 1997;169(4):1039-1043. doi:10.2214/ajr.169.4.9308463","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"66","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":66,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.5,"specificity":1.0},"tp":6.0,"fp":0.0,"fn":6.0,"tn":52.0,"sample_size":64.0,"observed_prevalence":0.1875,"sensitivity":0.5,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.896551724137931,"youden_j":0.5,"lr_positive":null,"lr_negative":0.5,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.6962122601251458,"conditional_entropy_bits_observed":0.43484777140211645,"information_bits_observed":0.26136448872302936,"information_fraction_observed":0.37540920160763686,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"156ba5b6fe2b"},{"id":"diagnostics-2024:67:061bc71b6bc4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pelvic CT","test_or_feature":"Pelvic CT","target_condition":"Septic pelvic thrombophlebitis","citation":"Twickler DM, Setiawan AT, Evans RS, et al. Imaging of puerperal septic thrombophlebitis: prospective comparison of MR imaging, CT, and sonography. AJR Am J Roentgenol. 1997;169(4):1039-1043. doi:10.2214/ajr.169.4.9308462","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"67","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":67,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":1.0,"specificity":0.98},"tp":12.0,"fp":1.0,"fn":0.0,"tn":51.0,"sample_size":64.0,"observed_prevalence":0.1875,"sensitivity":1.0,"specificity":0.9807692307692307,"ppv_observed":0.9230769230769231,"npv_observed":1.0,"youden_j":0.9807692307692308,"lr_positive":51.999999999999886,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.6962122601251458,"conditional_entropy_bits_observed":0.07947134886219252,"information_bits_observed":0.6167409112629533,"information_fraction_observed":0.8858518394262299,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b78f38a9c90b"},{"id":"diagnostics-2024:68:f4cee06b2516","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pelvic MRI","test_or_feature":"Pelvic MRI","target_condition":"Septic pelvic thrombophlebitis","citation":"Twickler DM, Setiawan AT, Evans RS, et al. Imaging of puerperal septic thrombophlebitis: prospective comparison of MR imaging, CT, and sonography. AJR Am J Roentgenol. 1997;169(4):1039-1043. doi:10.2214/ajr.169.4.9308461","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"68","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":68,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.92,"specificity":1.0},"tp":11.0,"fp":0.0,"fn":1.0,"tn":52.0,"sample_size":64.0,"observed_prevalence":0.1875,"sensitivity":0.9166666666666666,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9811320754716981,"youden_j":0.9166666666666665,"lr_positive":null,"lr_negative":0.08333333333333337,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.6962122601251458,"conditional_entropy_bits_observed":0.11182685544551195,"information_bits_observed":0.5843854046796338,"information_fraction_observed":0.8393782157392476,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7e2fa0570a8e"},{"id":"diagnostics-2024:69:1922cd596805","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"V/Q scan","test_or_feature":"V/Q scan","target_condition":"Chronic thromboembolic pulmonary hypertension","citation":"Tunariu N, Gibbs SJ, Win Z, et al. Ventilation-perfusion scintigraphy is more sensitive than multidetector CTPA in detecting chronic thromboembolic pulmonary disease as a treatable cause of pulmonary hypertension. J Nucl Med. 2007;48(5):680-684. doi:10.2967/jnumed.106.039438","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"69","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":69,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2007,"source_reported":{"sensitivity":0.96,"specificity":0.95},"tp":75.0,"fp":8.0,"fn":3.0,"tn":144.0,"sample_size":230.0,"observed_prevalence":0.3391304347826087,"sensitivity":0.9615384615384616,"specificity":0.9473684210526315,"ppv_observed":0.9036144578313253,"npv_observed":0.9795918367346939,"youden_j":0.9089068825910931,"lr_positive":18.269230769230752,"lr_negative":0.04059829059829057,"diagnostic_odds_ratio":450.0,"baseline_entropy_bits_observed":0.9239841591414172,"conditional_entropy_bits_observed":0.2569331217204035,"information_bits_observed":0.6670510374210137,"information_fraction_observed":0.7219290837635676,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ad11dec6fb3f"},{"id":"diagnostics-2024:70:cbf746844c9b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CT pulmonary angiography","test_or_feature":"CT pulmonary angiography","target_condition":"Chronic thromboembolic pulmonary hypertension","citation":"Tunariu N, Gibbs SJ, Win Z, et al. Ventilation-perfusion scintigraphy is more sensitive than multidetector CTPA in detecting chronic thromboembolic pulmonary disease as a treatable cause of pulmonary hypertension. J Nucl Med. 2007;48(5):680-684. doi:10.2967/jnumed.106.039438","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"70","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":70,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2007,"source_reported":{"sensitivity":0.51,"specificity":0.99},"tp":40.0,"fp":1.0,"fn":38.0,"tn":148.0,"sample_size":227.0,"observed_prevalence":0.3436123348017621,"sensitivity":0.5128205128205128,"specificity":0.9932885906040269,"ppv_observed":0.975609756097561,"npv_observed":0.7956989247311828,"youden_j":0.5061091034245395,"lr_positive":76.41025641025651,"lr_negative":0.4904712404712405,"diagnostic_odds_ratio":155.78947368421052,"baseline_entropy_bits_observed":0.9282335858807059,"conditional_entropy_bits_observed":0.6283951702026431,"information_bits_observed":0.2998384156780628,"information_fraction_observed":0.32302043390681323,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c6082feb4b34"},{"id":"diagnostics-2024:71:ed31cd04da98","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Alpha-fetoprotein","test_or_feature":"Alpha-fetoprotein","target_condition":"Hepatocellular carcinoma","citation":"Trevisani F, D'Intino PE, Morselli-Labate AM, et al. Serum alpha-fetoprotein for diagnosis of hepatocellular carcinoma in patients with chronic liver disease: influence of HBsAg and anti-HCV status. J Hepatol. 2001;34(4):570-575. doi:10.1016/s0168-8278(00)00053-2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"71","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":71,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2001,"source_reported":{"sensitivity":0.6,"specificity":0.91},"tp":102.0,"fp":16.0,"fn":68.0,"tn":154.0,"sample_size":340.0,"observed_prevalence":0.5,"sensitivity":0.6,"specificity":0.9058823529411765,"ppv_observed":0.864406779661017,"npv_observed":0.6936936936936937,"youden_j":0.5058823529411764,"lr_positive":6.375,"lr_negative":0.4415584415584416,"diagnostic_odds_ratio":14.4375,"baseline_entropy_bits_observed":1.0,"conditional_entropy_bits_observed":0.7790947552979128,"information_bits_observed":0.22090524470208717,"information_fraction_observed":0.22090524470208717,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"29a3fb95cdc4"},{"id":"diagnostics-2024:72:187af818955d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CXR","test_or_feature":"CXR","target_condition":"Lung cancer","citation":"Toyoda Y, Nakayama T, Kusunoki Y, Iso H, Suzuki T. Sensitivity and specificity of lung cancer screening using chest low-dose computed tomography. Br J Cancer. 2008;98(10):1602-1607. doi:10.1038/sj.bjc.6604366","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"72","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":72,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.78,"specificity":0.97},"tp":29.0,"fp":1081.0,"fn":8.0,"tn":34967.0,"sample_size":36085.0,"observed_prevalence":0.0010253567964528198,"sensitivity":0.7837837837837838,"specificity":0.9700122059476254,"ppv_observed":0.026126126126126126,"npv_observed":0.999771265189421,"youden_j":0.753795989731409,"lr_positive":26.136760257019272,"lr_negative":0.22290051082912926,"diagnostic_odds_ratio":117.25751618871415,"baseline_entropy_bits_observed":0.0116599611048448,"conditional_entropy_bits_observed":0.008371119764372954,"information_bits_observed":0.003288841340471846,"information_fraction_observed":0.2820628054329708,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cd6b22c54ef7"},{"id":"diagnostics-2024:73:16161d8d7efd","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Low-dose chest CT","test_or_feature":"Low-dose chest CT","target_condition":"Lung cancer","citation":"Toyoda Y, Nakayama T, Kusunoki Y, Iso H, Suzuki T. Sensitivity and specificity of lung cancer screening using chest low-dose computed tomography. Br J Cancer. 2008;98(10):1602-1607. doi:10.1038/sj.bjc.6604358","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"73","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":73,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.89,"specificity":0.93},"tp":40.0,"fp":528.0,"fn":5.0,"tn":6610.0,"sample_size":7183.0,"observed_prevalence":0.006264791869692329,"sensitivity":0.8888888888888888,"specificity":0.9260297001961334,"ppv_observed":0.07042253521126761,"npv_observed":0.999244142101285,"youden_j":0.8149185890850221,"lr_positive":12.01683501683502,"lr_negative":0.11998655236174152,"diagnostic_odds_ratio":100.15151515151516,"baseline_entropy_bits_observed":0.05485880389349281,"conditional_entropy_bits_observed":0.037282177381248234,"information_bits_observed":0.017576626512244578,"information_fraction_observed":0.32039755271312914,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"aa5248bd29fb"},{"id":"diagnostics-2024:74:3faf1bc22901","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Critical flicker frequency","test_or_feature":"Critical flicker frequency","target_condition":"Hepatic encephalopathy","citation":"Torlot FJ, McPhail MJ, Taylor-Robinson SD. Meta-analysis: The diagnostic accuracy of critical flicker frequency in minimal hepatic encephalopathy. Aliment Pharmacol Ther. 2013;37(5):527-536. doi:10.1111/apt.12199","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"74","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":74,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.61,"specificity":0.79},"tp":158.0,"fp":76.0,"fn":100.0,"tn":288.0,"sample_size":622.0,"observed_prevalence":0.41479099678456594,"sensitivity":0.6124031007751938,"specificity":0.7912087912087912,"ppv_observed":0.6752136752136753,"npv_observed":0.7422680412371134,"youden_j":0.40361189198398506,"lr_positive":2.933088535291717,"lr_negative":0.489879414298019,"diagnostic_odds_ratio":5.987368421052632,"baseline_entropy_bits_observed":0.9789478104336171,"conditional_entropy_bits_observed":0.8557357854092749,"information_bits_observed":0.12321202502434225,"information_fraction_observed":0.12586168916376295,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"aed78d071241"},{"id":"diagnostics-2024:75:e2b460b691b2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal CT","test_or_feature":"Abdominal CT","target_condition":"Diverticulitis","citation":"Toorenvliet, B. R. (2011, November 16). Acute abdominal pain: considerations on diagnosis and management. Retrieved from https://hdl.handle.net/1887/18093","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"75","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":75,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.95,"specificity":0.99},"tp":20.0,"fp":1.0,"fn":1.0,"tn":71.0,"sample_size":93.0,"observed_prevalence":0.22580645161290322,"sensitivity":0.9523809523809523,"specificity":0.9861111111111112,"ppv_observed":0.9523809523809523,"npv_observed":0.9861111111111112,"youden_j":0.9384920634920635,"lr_positive":68.57142857142881,"lr_negative":0.048289738430583554,"diagnostic_odds_ratio":1420.0,"baseline_entropy_bits_observed":0.7706290693639405,"conditional_entropy_bits_observed":0.14411460859807293,"information_bits_observed":0.6265144607658676,"information_fraction_observed":0.8129909520321862,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a57dd28f6196"},{"id":"diagnostics-2024:76:1c80e69947d6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Diverticulitis","citation":"Toorenvliet, B. R. (2011, November 16). Acute abdominal pain: considerations on diagnosis and management. Retrieved from https://hdl.handle.net/1887/18092","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"76","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":76,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.91,"specificity":1.0},"tp":20.0,"fp":0.0,"fn":2.0,"tn":383.0,"sample_size":405.0,"observed_prevalence":0.05432098765432099,"sensitivity":0.9090909090909091,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9948051948051948,"youden_j":0.9090909090909092,"lr_positive":null,"lr_negative":0.09090909090909094,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.3044760768157424,"conditional_entropy_bits_observed":0.04458101684422954,"information_bits_observed":0.25989505997151285,"information_fraction_observed":0.8535812162634757,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0c98b7374604"},{"id":"diagnostics-2024:77:e7562b36a4de","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"Diverticulitis","citation":"Toorenvliet, B. R. (2011, November 16). Acute abdominal pain: considerations on diagnosis and management. Retrieved from https://hdl.handle.net/1887/18091","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"77","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":77,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.68,"specificity":0.98},"tp":30.0,"fp":16.0,"fn":14.0,"tn":728.0,"sample_size":788.0,"observed_prevalence":0.05583756345177665,"sensitivity":0.6818181818181818,"specificity":0.978494623655914,"ppv_observed":0.6521739130434783,"npv_observed":0.9811320754716981,"youden_j":0.6603128054740957,"lr_positive":31.70454545454548,"lr_negative":0.3251748251748252,"diagnostic_odds_ratio":97.5,"baseline_entropy_bits_observed":0.3106950343238682,"conditional_entropy_bits_observed":0.18156598298165705,"information_bits_observed":0.12912905134221114,"information_fraction_observed":0.41561350223450033,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1059efb8c7fe"},{"id":"diagnostics-2024:78:6bb90cb8d874","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Plasma renin activity","test_or_feature":"Plasma renin activity","target_condition":"Hyperaldosteronism","citation":"Tiu SC, Choi CH, Shek CC, et al. The use of aldosterone-renin ratio as a diagnostic test for primary hyperaldosteronism and its test characteristics under different conditions of blood sampling. J Clin Endocrinol Metab. 2005;90(1):72-78. doi:10.1210/jc.2004-1151","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"78","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":78,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.91,"specificity":0.88},"tp":41.0,"fp":2.0,"fn":4.0,"tn":15.0,"sample_size":62.0,"observed_prevalence":0.7258064516129032,"sensitivity":0.9111111111111111,"specificity":0.8823529411764706,"ppv_observed":0.9534883720930233,"npv_observed":0.7894736842105263,"youden_j":0.7934640522875815,"lr_positive":7.744444444444443,"lr_negative":0.10074074074074077,"diagnostic_odds_ratio":76.875,"baseline_entropy_bits_observed":0.8474179614176633,"conditional_entropy_bits_observed":0.4157583239378891,"information_bits_observed":0.43165963747977426,"information_fraction_observed":0.5093822141291905,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4dc12b06859a"},{"id":"diagnostics-2024:79:6b86051257f2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Plasma aldosterone","test_or_feature":"Plasma aldosterone","target_condition":"Hyperaldosteronism","citation":"Tiu SC, Choi CH, Shek CC, et al. The use of aldosterone-renin ratio as a diagnostic test for primary hyperaldosteronism and its test characteristics under different conditions of blood sampling. J Clin Endocrinol Metab. 2005;90(1):72-78. doi:10.1210/jc.2004-1150","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"79","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":79,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.91,"specificity":0.82},"tp":41.0,"fp":3.0,"fn":4.0,"tn":14.0,"sample_size":62.0,"observed_prevalence":0.7258064516129032,"sensitivity":0.9111111111111111,"specificity":0.8235294117647058,"ppv_observed":0.9318181818181818,"npv_observed":0.7777777777777778,"youden_j":0.734640522875817,"lr_positive":5.162962962962962,"lr_negative":0.10793650793650797,"diagnostic_odds_ratio":47.833333333333336,"baseline_entropy_bits_observed":0.8474179614176633,"conditional_entropy_bits_observed":0.4767121394466347,"information_bits_observed":0.37070582197102864,"information_fraction_observed":0.4374533451602407,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"24846ae365d4"},{"id":"diagnostics-2024:80:ce6e17cf1122","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Aldosterone-to-renin ratio","test_or_feature":"Aldosterone-to-renin ratio","target_condition":"Hyperaldosteronism","citation":"Tiu SC, Choi CH, Shek CC, et al. The use of aldosterone-renin ratio as a diagnostic test for primary hyperaldosteronism and its test characteristics under different conditions of blood sampling. J Clin Endocrinol Metab. 2005;90(1):72-78. doi:10.1210/jc.2004-1149","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"80","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":80,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.98,"specificity":0.94},"tp":44.0,"fp":1.0,"fn":1.0,"tn":16.0,"sample_size":62.0,"observed_prevalence":0.7258064516129032,"sensitivity":0.9777777777777777,"specificity":0.9411764705882353,"ppv_observed":0.9777777777777777,"npv_observed":0.9411764705882353,"youden_j":0.9189542483660129,"lr_positive":16.622222222222216,"lr_negative":0.023611111111111145,"diagnostic_odds_ratio":704.0,"baseline_entropy_bits_observed":0.8474179614176633,"conditional_entropy_bits_observed":0.2000849421943558,"information_bits_observed":0.6473330192233075,"information_fraction_observed":0.7638887168975868,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f73acc3a48c0"},{"id":"diagnostics-2024:81:1aba26021750","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Low-dose CT scan","test_or_feature":"Low-dose CT scan","target_condition":"Diverticulitis","citation":"Thorisson A, Nikberg M, Torkzad MR, Laurell H, Smedh K, Chabok A. Diagnostic accuracy of acute diverticulitis with unenhanced low-dose CT. BJS Open. 2020;4(4):659-665. doi:10.1002/bjs5.50290","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"81","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":81,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.99,"specificity":0.98},"tp":211.0,"fp":2.0,"fn":3.0,"tn":84.0,"sample_size":300.0,"observed_prevalence":0.7133333333333334,"sensitivity":0.985981308411215,"specificity":0.9767441860465116,"ppv_observed":0.9906103286384976,"npv_observed":0.9655172413793104,"youden_j":0.9627254944577266,"lr_positive":42.39719626168217,"lr_negative":0.01435246995994654,"diagnostic_odds_ratio":2954.0,"baseline_entropy_bits_observed":0.8643763438484613,"conditional_entropy_bits_observed":0.11722584471382513,"information_bits_observed":0.7471504991346362,"information_fraction_observed":0.864381012335552,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0c6bd22e9599"},{"id":"diagnostics-2024:82:bd84ee49f350","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CSF Ag","test_or_feature":"CSF Ag","target_condition":"Cryptococcal meningitis","citation":"Temfack E, Rim JJB, Spijker R, et al. Cryptococcal Antigen in Serum and Cerebrospinal Fluid for Detecting Cryptococcal Meningitis in Adults Living With Human Immunodeficiency Virus: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies. Clin Infect Dis. 2021;72(7):1268-1278. doi:10.1093/cid/ciaa1243","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"82","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":82,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.98,"specificity":0.98},"tp":2292.0,"fp":53.0,"fn":41.0,"tn":2480.0,"sample_size":4866.0,"observed_prevalence":0.47944923962186603,"sensitivity":0.982426060865838,"specificity":0.9790761942360837,"ppv_observed":0.9773987206823028,"npv_observed":0.9837366124553748,"youden_j":0.9615022551019217,"lr_positive":46.95255117307869,"lr_negative":0.01794951122049697,"diagnostic_odds_ratio":2615.812241141279,"baseline_entropy_bits_observed":0.9987810590451077,"conditional_entropy_bits_observed":0.13721030725311856,"information_bits_observed":0.8615707517919892,"information_fraction_observed":0.8626222373657151,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b7ef138aab6c"},{"id":"diagnostics-2024:83:d308e9c273cf","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum Ag","test_or_feature":"Serum Ag","target_condition":"Cryptococcal meningitis","citation":"Temfack E, Rim JJB, Spijker R, et al. Cryptococcal Antigen in Serum and Cerebrospinal Fluid for Detecting Cryptococcal Meningitis in Adults Living With Human Immunodeficiency Virus: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies. Clin Infect Dis. 2021;72(7):1268-1278. doi:10.1093/cid/ciaa1243","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"83","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":83,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.99,"specificity":0.91},"tp":1150.0,"fp":85.0,"fn":11.0,"tn":864.0,"sample_size":2110.0,"observed_prevalence":0.5502369668246445,"sensitivity":0.9905254091300603,"specificity":0.9104320337197049,"ppv_observed":0.9311740890688259,"npv_observed":0.9874285714285714,"youden_j":0.9009574428497653,"lr_positive":11.058924861934436,"lr_negative":0.010406697610616678,"diagnostic_odds_ratio":1062.673796791444,"baseline_entropy_bits_observed":0.9927056868580757,"conditional_entropy_bits_observed":0.2519933114313977,"information_bits_observed":0.740712375426678,"information_fraction_observed":0.7461550641167783,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0e5b52f006d3"},{"id":"diagnostics-2024:84:88cd315bff6a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Smartphone videos","test_or_feature":"Smartphone videos","target_condition":"Epileptic seizure","citation":"Tatum WO, Hirsch LJ, Gelfand MA, et al. Assessment of the Predictive Value of Outpatient Smartphone Videos for Diagnosis of Epileptic Seizures. JAMA Neurol. 2020;77(5):593–600. doi:10.1001/jamaneurol.2019.4785","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"84","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":84,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.6,"specificity":0.91},"tp":65.0,"fp":27.0,"fn":44.0,"tn":274.0,"sample_size":410.0,"observed_prevalence":0.2658536585365854,"sensitivity":0.5963302752293578,"specificity":0.9102990033222591,"ppv_observed":0.7065217391304348,"npv_observed":0.8616352201257862,"youden_j":0.5066292785516169,"lr_positive":6.6479782534828376,"lr_negative":0.44344739837942815,"diagnostic_odds_ratio":14.991582491582491,"baseline_entropy_bits_observed":0.8354517724192136,"conditional_entropy_bits_observed":0.6457386033687356,"information_bits_observed":0.18971316905047808,"information_fraction_observed":0.22707854039393152,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f2850a1ea42f"},{"id":"diagnostics-2024:85:df6cda6cc99f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"QuickVue Influenza A+B test","test_or_feature":"QuickVue Influenza A+B test","target_condition":"Influenza infection","citation":"Tai CF, Lu CY, Shao PL, Lee PI, Chang LY, Huang LM. Rapid-test sensitivity for novel swine-origin pandemic influenza A. J Formos Med Assoc. 2012;111(8):427-430. doi:10.1016/j.jfma.2011.06.018","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"85","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":85,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.82,"specificity":0.99},"tp":419.0,"fp":1.0,"fn":94.0,"tn":70.0,"sample_size":584.0,"observed_prevalence":0.8784246575342466,"sensitivity":0.8167641325536062,"specificity":0.9859154929577465,"ppv_observed":0.9976190476190476,"npv_observed":0.4268292682926829,"youden_j":0.8026796255113529,"lr_positive":57.99025341130612,"lr_negative":0.18585352269562794,"diagnostic_odds_ratio":312.02127659574467,"baseline_entropy_bits_observed":0.5338722498196556,"conditional_entropy_bits_observed":0.29385716988572486,"information_bits_observed":0.24001507993393079,"information_fraction_observed":0.4495739945558304,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e45204880a3c"},{"id":"diagnostics-2024:86:0c2f48aeccc4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal CT","test_or_feature":"Abdominal CT","target_condition":"Bowel obstruction","citation":"Suri S, Gupta S, Sudhakar PJ, Venkataramu NK, Sood B, Wig JD. Comparative evaluation of plain films, ultrasound and CT in the diagnosis of intestinal obstruction. Acta Radiol. 1999;40(4):422-428. doi:10.3109/02841859909177758","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"86","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":86,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.93,"specificity":1.0},"tp":28.0,"fp":0.0,"fn":2.0,"tn":2.0,"sample_size":32.0,"observed_prevalence":0.9375,"sensitivity":0.9333333333333333,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.5,"youden_j":0.9333333333333333,"lr_positive":null,"lr_negative":0.06666666666666665,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.3372900666170139,"conditional_entropy_bits_observed":0.125,"information_bits_observed":0.21229006661701388,"information_fraction_observed":0.6293991066688157,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c855866254df","condition_context_id":"condition:bowel_obstruction"},{"id":"diagnostics-2024:87:1b9ffe9a770d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Bowel obstruction","citation":"Suri S, Gupta S, Sudhakar PJ, Venkataramu NK, Sood B, Wig JD. Comparative evaluation of plain films, ultrasound and CT in the diagnosis of intestinal obstruction. Acta Radiol. 1999;40(4):422-428. doi:10.3109/02841859909177758","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"87","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":87,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.83,"specificity":1.0},"tp":25.0,"fp":0.0,"fn":5.0,"tn":2.0,"sample_size":32.0,"observed_prevalence":0.9375,"sensitivity":0.8333333333333334,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.2857142857142857,"youden_j":0.8333333333333335,"lr_positive":null,"lr_negative":0.16666666666666663,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.3372900666170139,"conditional_entropy_bits_observed":0.18880762437395054,"information_bits_observed":0.14848244224306334,"information_fraction_observed":0.44022180591420196,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e89ad184e33d","condition_context_id":"condition:bowel_obstruction"},{"id":"diagnostics-2024:88:588d10eda18a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal X-ray","test_or_feature":"Abdominal X-ray","target_condition":"Bowel obstruction","citation":"Suri S, Gupta S, Sudhakar PJ, Venkataramu NK, Sood B, Wig JD. Comparative evaluation of plain films, ultrasound and CT in the diagnosis of intestinal obstruction. Acta Radiol. 1999;40(4):422-428. doi:10.3109/02841859909177758","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"88","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":88,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.77,"specificity":0.5},"tp":23.0,"fp":1.0,"fn":7.0,"tn":1.0,"sample_size":32.0,"observed_prevalence":0.9375,"sensitivity":0.7666666666666667,"specificity":0.5,"ppv_observed":0.9583333333333334,"npv_observed":0.125,"youden_j":0.2666666666666666,"lr_positive":1.5333333333333334,"lr_negative":0.46666666666666656,"diagnostic_odds_ratio":3.2857142857142856,"baseline_entropy_bits_observed":0.3372900666170139,"conditional_entropy_bits_observed":0.32330283042478813,"information_bits_observed":0.01398723619222575,"information_fraction_observed":0.04146945782458508,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3da13a06b8c1","condition_context_id":"condition:bowel_obstruction"},{"id":"diagnostics-2024:89:e0d00daa79a6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PCR","test_or_feature":"PCR","target_condition":"Neonatal sepsis","citation":"Straub J, Paula H, Mayr M, Kasper D, Assadian O, Berger A, et al. (2017) Diagnostic accuracy of the ROCHE Septifast PCR system for the rapid detection of blood pathogens in neonatal sepsis—A prospective clinical trial. PLoS ONE 12(11): e0187688. https://doi.org/10.1371/journal.pone.0187688","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"89","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":89,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.9,"specificity":0.73},"tp":46.0,"fp":23.0,"fn":5.0,"tn":62.0,"sample_size":136.0,"observed_prevalence":0.375,"sensitivity":0.9019607843137255,"specificity":0.7294117647058823,"ppv_observed":0.6666666666666666,"npv_observed":0.9253731343283582,"youden_j":0.6313725490196078,"lr_positive":3.333333333333333,"lr_negative":0.13440860215053763,"diagnostic_odds_ratio":24.8,"baseline_entropy_bits_observed":0.954434002924965,"conditional_entropy_bits_observed":0.6545630631765254,"information_bits_observed":0.2998709397484397,"information_fraction_observed":0.3141871924401825,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"170c20152d97"},{"id":"diagnostics-2024:90:a7377b85f255","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Xylose breath test","test_or_feature":"Xylose breath test","target_condition":"Small intestinal bacterial overgrowth","citation":"Stotzer PO, Kilander AF. Comparison of the 1-gram (14)C-D-xylose breath test and the 50-gram hydrogen glucose breath test for diagnosis of small intestinal bacterial overgrowth. Digestion. 2000;61(3):165-171. doi:10.1159/000007754","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"90","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":90,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.42,"specificity":0.86},"tp":10.0,"fp":3.0,"fn":14.0,"tn":19.0,"sample_size":46.0,"observed_prevalence":0.5217391304347826,"sensitivity":0.4166666666666667,"specificity":0.8636363636363636,"ppv_observed":0.7692307692307693,"npv_observed":0.5757575757575758,"youden_j":0.2803030303030303,"lr_positive":3.055555555555556,"lr_negative":0.675438596491228,"diagnostic_odds_ratio":4.523809523809524,"baseline_entropy_bits_observed":0.9986359641585718,"conditional_entropy_bits_observed":0.9257165686824235,"information_bits_observed":0.07291939547614834,"information_fraction_observed":0.07301899600380263,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"81d491d097d3"},{"id":"diagnostics-2024:91:cc2964a0f19a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Glucose hydrogen breath test","test_or_feature":"Glucose hydrogen breath test","target_condition":"Small intestinal bacterial overgrowth","citation":"Stotzer PO, Kilander AF. Comparison of the 1-gram (14)C-D-xylose breath test and the 50-gram hydrogen glucose breath test for diagnosis of small intestinal bacterial overgrowth. Digestion. 2000;61(3):165-171. doi:10.1159/000007753","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"91","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":91,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.58,"specificity":0.86},"tp":14.0,"fp":3.0,"fn":10.0,"tn":19.0,"sample_size":46.0,"observed_prevalence":0.5217391304347826,"sensitivity":0.5833333333333334,"specificity":0.8636363636363636,"ppv_observed":0.8235294117647058,"npv_observed":0.6551724137931034,"youden_j":0.446969696969697,"lr_positive":4.277777777777779,"lr_negative":0.48245614035087714,"diagnostic_odds_ratio":8.866666666666667,"baseline_entropy_bits_observed":0.9986359641585718,"conditional_entropy_bits_observed":0.8343599357539931,"information_bits_observed":0.16427602840457867,"information_fraction_observed":0.16450041286365444,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9dfd7d740360"},{"id":"diagnostics-2024:92:fa036d01dca1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Canadian C-Spine Rule","test_or_feature":"Canadian C-Spine Rule","target_condition":"Need for cervical radiography","citation":"Stiell IG, Wells GA, Vandemheen KL, et al. The Canadian C-Spine Rule for Radiography in Alert and Stable Trauma Patients. JAMA. 2001;286(15):1841–1848. doi:10.1001/jama.286.15.1841","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"92","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":92,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2001,"source_reported":{"sensitivity":1.0,"specificity":0.43},"tp":151.0,"fp":5041.0,"fn":0.0,"tn":3732.0,"sample_size":8924.0,"observed_prevalence":0.01692066337965038,"sensitivity":1.0,"specificity":0.42539610167559555,"ppv_observed":0.02908320493066256,"npv_observed":1.0,"youden_j":0.4253961016755956,"lr_positive":1.7403292997421147,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.12378294357961266,"conditional_entropy_bits_observed":0.11041036550506897,"information_bits_observed":0.013372578074543687,"information_fraction_observed":0.108032477559745,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7c154d5c1250"},{"id":"diagnostics-2024:93:d2a33d15615d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Canadian CT Head Rule, GC15","test_or_feature":"Canadian CT Head Rule, GC15","target_condition":"Need for neurosurgical intervention","citation":"Stiell IG, Clement CM, Rowe BH, et al. Comparison of the Canadian CT Head Rule and the New Orleans Criteria in Patients With Minor Head Injury. JAMA. 2005;294(12):1511–1518. doi:10.1001/jama.294.12.1511","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"93","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":93,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":1.0,"specificity":0.76},"tp":8.0,"fp":430.0,"fn":0.0,"tn":1384.0,"sample_size":1822.0,"observed_prevalence":0.0043907793633369925,"sensitivity":1.0,"specificity":0.762954796030871,"ppv_observed":0.0182648401826484,"npv_observed":1.0,"youden_j":0.7629547960308711,"lr_positive":4.218604651162791,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.04070617063040434,"conditional_entropy_bits_observed":0.03163216618103514,"information_bits_observed":0.009074004449369198,"information_fraction_observed":0.22291471560313325,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d94b96318225"},{"id":"diagnostics-2024:94:1a5e306f5a6c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Canadian CT Head Rule, GC13-15","test_or_feature":"Canadian CT Head Rule, GC13-15","target_condition":"Need for neurosurgical intervention","citation":"Stiell IG, Clement CM, Rowe BH, et al. Comparison of the Canadian CT Head Rule and the New Orleans Criteria in Patients With Minor Head Injury. JAMA. 2005;294(12):1511–1518. doi:10.1001/jama.294.12.1511","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"94","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":94,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":1.0,"specificity":0.66},"tp":41.0,"fp":918.0,"fn":0.0,"tn":1748.0,"sample_size":2707.0,"observed_prevalence":0.015145917990395271,"sensitivity":1.0,"specificity":0.6556639159789948,"ppv_observed":0.04275286757038582,"npv_observed":1.0,"youden_j":0.6556639159789948,"lr_positive":2.9041394335511983,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.11324059381949123,"conditional_entropy_bits_observed":0.09025817893209104,"information_bits_observed":0.022982414887400188,"information_fraction_observed":0.20295208734100087,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"73b4c5e23628"},{"id":"diagnostics-2024:95:56166e990905","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Canadian CT Head Rule, GC15","test_or_feature":"Canadian CT Head Rule, GC15","target_condition":"Clinically important brain injury","citation":"Stiell IG, Clement CM, Rowe BH, et al. Comparison of the Canadian CT Head Rule and the New Orleans Criteria in Patients With Minor Head Injury. JAMA. 2005;294(12):1511–1518. doi:10.1001/jama.294.12.1511","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"95","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":95,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":1.0,"specificity":0.51},"tp":97.0,"fp":853.0,"fn":0.0,"tn":872.0,"sample_size":1822.0,"observed_prevalence":0.05323819978046103,"sensitivity":1.0,"specificity":0.5055072463768115,"ppv_observed":0.10210526315789474,"npv_observed":1.0,"youden_j":0.5055072463768115,"lr_positive":2.022274325908558,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.2999965077999141,"conditional_entropy_bits_observed":0.24799787318921063,"information_bits_observed":0.051998634610703476,"information_fraction_observed":0.1733307997217905,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7ad84a6bfdb7"},{"id":"diagnostics-2024:96:ee2e057b38c0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Canadian CT Head Rule, GC13-15","test_or_feature":"Canadian CT Head Rule, GC13-15","target_condition":"Clinically important brain injury","citation":"Stiell IG, Clement CM, Rowe BH, et al. Comparison of the Canadian CT Head Rule and the New Orleans Criteria in Patients With Minor Head Injury. JAMA. 2005;294(12):1511–1518. doi:10.1001/jama.294.12.1511","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"96","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":96,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":1.0,"specificity":0.41},"tp":231.0,"fp":1458.0,"fn":0.0,"tn":1018.0,"sample_size":2707.0,"observed_prevalence":0.08533431843369044,"sensitivity":1.0,"specificity":0.4111470113085622,"ppv_observed":0.13676731793960922,"npv_observed":1.0,"youden_j":0.41114701130856224,"lr_positive":1.6982167352537725,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.42070158365876553,"conditional_entropy_bits_observed":0.3592071175270619,"information_bits_observed":0.06149446613170362,"information_fraction_observed":0.14617122568661942,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0a418ded3674"},{"id":"diagnostics-2024:97:6076c9d164b5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"New Orleans Criteria, GC15","test_or_feature":"New Orleans Criteria, GC15","target_condition":"Clinically important brain injury","citation":"Stiell IG, Clement CM, Rowe BH, et al. Comparison of the Canadian CT Head Rule and the New Orleans Criteria in Patients With Minor Head Injury. JAMA. 2005;294(12):1511–1518. doi:10.1001/jama.294.12.1511","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"97","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":97,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":1.0,"specificity":0.13},"tp":97.0,"fp":1506.0,"fn":0.0,"tn":219.0,"sample_size":1822.0,"observed_prevalence":0.05323819978046103,"sensitivity":1.0,"specificity":0.12695652173913044,"ppv_observed":0.06051154086088584,"npv_observed":1.0,"youden_j":0.1269565217391304,"lr_positive":1.145418326693227,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.2999965077999141,"conditional_entropy_bits_observed":0.2898704436606286,"information_bits_observed":0.010126064139285518,"information_fraction_observed":0.03375394004932619,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8137417fb343"},{"id":"diagnostics-2024:98:be8855de37ad","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"New Orleans Criteria, GC15","test_or_feature":"New Orleans Criteria, GC15","target_condition":"Need for neurosurgical intervention","citation":"Stiell IG, Clement CM, Rowe BH, et al. Comparison of the Canadian CT Head Rule and the New Orleans Criteria in Patients With Minor Head Injury. JAMA. 2005;294(12):1511–1518. doi:10.1001/jama.294.12.1511","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"98","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":98,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":1.0,"specificity":0.12},"tp":8.0,"fp":1595.0,"fn":0.0,"tn":219.0,"sample_size":1822.0,"observed_prevalence":0.0043907793633369925,"sensitivity":1.0,"specificity":0.1207276736493936,"ppv_observed":0.004990642545227698,"npv_observed":1.0,"youden_j":0.12072767364939363,"lr_positive":1.1373040752351098,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.04070617063040434,"conditional_entropy_bits_observed":0.039893074685746995,"information_bits_observed":0.0008130959446573452,"information_fraction_observed":0.019974758914070533,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6f9207bd0ae5"},{"id":"diagnostics-2024:99:3caff32a0309","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care US","test_or_feature":"Point-of-care US","target_condition":"Mixed type shock","citation":"Stickles SP, Carpenter CR, Gekle R, et al. The diagnostic accuracy of a point-of-care ultrasound protocol for shock etiology: A systematic review and meta-analysis. CJEM. 2019;21(3):406-417. doi:10.1017/cem.2018.502","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"99","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":99,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.75,"specificity":0.8},"tp":18.0,"fp":41.0,"fn":6.0,"tn":161.0,"sample_size":226.0,"observed_prevalence":0.10619469026548672,"sensitivity":0.75,"specificity":0.7970297029702971,"ppv_observed":0.3050847457627119,"npv_observed":0.9640718562874252,"youden_j":0.5470297029702971,"lr_positive":3.695121951219513,"lr_negative":0.3136645962732919,"diagnostic_odds_ratio":11.78048780487805,"baseline_entropy_bits_observed":0.48833020341885897,"conditional_entropy_bits_observed":0.3966764697320001,"information_bits_observed":0.09165373368685886,"information_fraction_observed":0.1876880296266337,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e1c20eb6924a"},{"id":"diagnostics-2024:100:be11909ad9cc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care US","test_or_feature":"Point-of-care US","target_condition":"Distributive shock","citation":"Stickles SP, Carpenter CR, Gekle R, et al. The diagnostic accuracy of a point-of-care ultrasound protocol for shock etiology: A systematic review and meta-analysis. CJEM. 2019;21(3):406-417. doi:10.1017/cem.2018.501","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"100","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":100,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.64,"specificity":0.95},"tp":87.0,"fp":10.0,"fn":48.0,"tn":199.0,"sample_size":344.0,"observed_prevalence":0.39244186046511625,"sensitivity":0.6444444444444445,"specificity":0.9521531100478469,"ppv_observed":0.8969072164948454,"npv_observed":0.805668016194332,"youden_j":0.5965975544922912,"lr_positive":13.468888888888882,"lr_negative":0.3734226689000558,"diagnostic_odds_ratio":36.06875,"baseline_entropy_bits_observed":0.96635730061266,"conditional_entropy_bits_observed":0.6451057769856168,"information_bits_observed":0.32125152362704323,"information_fraction_observed":0.33243555300236594,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"72099044bb4f"},{"id":"diagnostics-2024:101:cb217901cdc0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care US","test_or_feature":"Point-of-care US","target_condition":"Obstructive shock","citation":"Stickles SP, Carpenter CR, Gekle R, et al. The diagnostic accuracy of a point-of-care ultrasound protocol for shock etiology: A systematic review and meta-analysis. CJEM. 2019;21(3):406-417. doi:10.1017/cem.2018.500","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"101","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":101,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.93,"specificity":0.98},"tp":14.0,"fp":5.0,"fn":1.0,"tn":324.0,"sample_size":344.0,"observed_prevalence":0.0436046511627907,"sensitivity":0.9333333333333333,"specificity":0.9848024316109423,"ppv_observed":0.7368421052631579,"npv_observed":0.9969230769230769,"youden_j":0.9181357649442756,"lr_positive":61.41333333333344,"lr_negative":0.06769547325102879,"diagnostic_odds_ratio":907.2,"baseline_entropy_bits_observed":0.2585820207107542,"conditional_entropy_bits_observed":0.07436855380874108,"information_bits_observed":0.18421346690201312,"information_fraction_observed":0.7123985898001448,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ab29b3cf3b29"},{"id":"diagnostics-2024:102:e55756ba7ffa","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care US","test_or_feature":"Point-of-care US","target_condition":"Cardiogenic shock","citation":"Stickles SP, Carpenter CR, Gekle R, et al. The diagnostic accuracy of a point-of-care ultrasound protocol for shock etiology: A systematic review and meta-analysis. CJEM. 2019;21(3):406-417. doi:10.1017/cem.2018.499","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"102","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":102,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.83,"specificity":0.97},"tp":50.0,"fp":8.0,"fn":10.0,"tn":276.0,"sample_size":344.0,"observed_prevalence":0.1744186046511628,"sensitivity":0.8333333333333334,"specificity":0.971830985915493,"ppv_observed":0.8620689655172413,"npv_observed":0.965034965034965,"youden_j":0.8051643192488265,"lr_positive":29.583333333333375,"lr_negative":0.17149758454106276,"diagnostic_odds_ratio":172.5,"baseline_entropy_bits_observed":0.667713540528142,"conditional_entropy_bits_observed":0.2794222660687037,"information_bits_observed":0.38829127445943834,"information_fraction_observed":0.5815237386863702,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"15f9e8882fbd"},{"id":"diagnostics-2024:103:47522664f367","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care US","test_or_feature":"Point-of-care US","target_condition":"Hypovolemic shock","citation":"Stickles SP, Carpenter CR, Gekle R, et al. The diagnostic accuracy of a point-of-care ultrasound protocol for shock etiology: A systematic review and meta-analysis. CJEM. 2019;21(3):406-417. doi:10.1017/cem.2018.498","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"103","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":103,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.81,"specificity":0.91},"tp":88.0,"fp":22.0,"fn":20.0,"tn":219.0,"sample_size":349.0,"observed_prevalence":0.30945558739255014,"sensitivity":0.8148148148148148,"specificity":0.9087136929460581,"ppv_observed":0.8,"npv_observed":0.9163179916317992,"youden_j":0.7235285077608729,"lr_positive":8.925925925925924,"lr_negative":0.2037882631489938,"diagnostic_odds_ratio":43.8,"baseline_entropy_bits_observed":0.8925440277423877,"conditional_entropy_bits_observed":0.5117545260590387,"information_bits_observed":0.380789501683349,"information_fraction_observed":0.426633857655765,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"54f4686a1cf1"},{"id":"diagnostics-2024:104:7f38a4cb0e5a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Blood smear","test_or_feature":"Blood smear","target_condition":"Malaria","citation":"Stauffer WM, Cartwright CP, Olson DA, et al. Diagnostic performance of rapid diagnostic tests versus blood smears for malaria in US clinical practice. Clin Infect Dis. 2009;49(6):908-913. doi:10.1086/605437","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"104","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":104,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.85,"specificity":1.0},"tp":81.0,"fp":0.0,"fn":14.0,"tn":757.0,"sample_size":852.0,"observed_prevalence":0.11150234741784038,"sensitivity":0.8526315789473684,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9818417639429312,"youden_j":0.8526315789473684,"lr_positive":null,"lr_negative":0.1473684210526316,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.5044309269034921,"conditional_entropy_bits_observed":0.11851934584094621,"information_bits_observed":0.3859115810625459,"information_fraction_observed":0.7650434588368897,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b30ecec9d1f5"},{"id":"diagnostics-2024:105:071efaed5a7e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid diagnostic test","test_or_feature":"Rapid diagnostic test","target_condition":"Malaria","citation":"Stauffer WM, Cartwright CP, Olson DA, et al. Diagnostic performance of rapid diagnostic tests versus blood smears for malaria in US clinical practice. Clin Infect Dis. 2009;49(6):908-913. doi:10.1086/605436","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"105","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":105,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.97,"specificity":0.99},"tp":92.0,"fp":8.0,"fn":3.0,"tn":749.0,"sample_size":852.0,"observed_prevalence":0.11150234741784038,"sensitivity":0.968421052631579,"specificity":0.9894319682959049,"ppv_observed":0.92,"npv_observed":0.9960106382978723,"youden_j":0.9578530209274838,"lr_positive":91.63684210526284,"lr_negative":0.03191623919612113,"diagnostic_odds_ratio":2871.1666666666665,"baseline_entropy_bits_observed":0.5044309269034921,"conditional_entropy_bits_observed":0.0803359607324444,"information_bits_observed":0.4240949661710477,"information_fraction_observed":0.8407394224902187,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5af8c98e4820"},{"id":"diagnostics-2024:106:07f1df94504c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PCT (ng/mL)","test_or_feature":"PCT (ng/mL)","target_condition":"Sepsis","citation":"Spoto S, Nobile E, Carnà EPR, et al. Best diagnostic accuracy of sepsis combining SIRS criteria or qSOFA score with Procalcitonin and Mid-Regional pro-Adrenomedullin outside ICU. Sci Rep. 2020;10(1):16605. Published 2020 Oct 6. doi:10.1038/s41598-020-73676-y","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"106","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":106,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.68,"specificity":0.98},"tp":142.0,"fp":1.0,"fn":67.0,"tn":49.0,"sample_size":259.0,"observed_prevalence":0.806949806949807,"sensitivity":0.6794258373205742,"specificity":0.98,"ppv_observed":0.993006993006993,"npv_observed":0.4224137931034483,"youden_j":0.6594258373205741,"lr_positive":33.97129186602868,"lr_negative":0.3271164925300264,"diagnostic_odds_ratio":103.85074626865672,"baseline_entropy_bits_observed":0.7078087969775162,"conditional_entropy_bits_observed":0.47326080116651437,"information_bits_observed":0.23454799581100183,"information_fraction_observed":0.3313719705273066,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"020a03257e63","condition_context_id":"condition:sepsis"},{"id":"diagnostics-2024:107:86c83f9aa353","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MR-proADM (nmol/L)","test_or_feature":"MR-proADM (nmol/L)","target_condition":"Sepsis","citation":"Spoto S, Nobile E, Carnà EPR, et al. Best diagnostic accuracy of sepsis combining SIRS criteria or qSOFA score with Procalcitonin and Mid-Regional pro-Adrenomedullin outside ICU. Sci Rep. 2020;10(1):16605. Published 2020 Oct 6. doi:10.1038/s41598-020-73676-y","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"107","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":107,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.83,"specificity":0.76},"tp":173.0,"fp":12.0,"fn":36.0,"tn":38.0,"sample_size":259.0,"observed_prevalence":0.806949806949807,"sensitivity":0.8277511961722488,"specificity":0.76,"ppv_observed":0.9351351351351351,"npv_observed":0.5135135135135135,"youden_j":0.5877511961722488,"lr_positive":3.44896331738437,"lr_negative":0.22664316293125158,"diagnostic_odds_ratio":15.217592592592593,"baseline_entropy_bits_observed":0.7078087969775162,"conditional_entropy_bits_observed":0.5330360629323294,"information_bits_observed":0.17477273404518678,"information_fraction_observed":0.2469208277595602,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2ca92e10e428","condition_context_id":"condition:sepsis"},{"id":"diagnostics-2024:108:f5c40af5dbbe","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"SIRS criteria","test_or_feature":"SIRS criteria","target_condition":"Sepsis","citation":"Spoto S, Nobile E, Carnà EPR, et al. Best diagnostic accuracy of sepsis combining SIRS criteria or qSOFA score with Procalcitonin and Mid-Regional pro-Adrenomedullin outside ICU. Sci Rep. 2020;10(1):16605. Published 2020 Oct 6. doi:10.1038/s41598-020-73676-y","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"108","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":108,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.75,"specificity":0.84},"tp":157.0,"fp":8.0,"fn":52.0,"tn":42.0,"sample_size":259.0,"observed_prevalence":0.806949806949807,"sensitivity":0.7511961722488039,"specificity":0.84,"ppv_observed":0.9515151515151515,"npv_observed":0.44680851063829785,"youden_j":0.5911961722488037,"lr_positive":4.694976076555023,"lr_negative":0.2961950330371383,"diagnostic_odds_ratio":15.850961538461538,"baseline_entropy_bits_observed":0.7078087969775162,"conditional_entropy_bits_observed":0.538296767305897,"information_bits_observed":0.16951202967161916,"information_fraction_observed":0.23948844715616577,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cf910d14c3c7","condition_context_id":"condition:sepsis"},{"id":"diagnostics-2024:109:5e879495db3b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"SOFA score","test_or_feature":"SOFA score","target_condition":"Sepsis","citation":"Spoto S, Nobile E, Carnà EPR, et al. Best diagnostic accuracy of sepsis combining SIRS criteria or qSOFA score with Procalcitonin and Mid-Regional pro-Adrenomedullin outside ICU. Sci Rep. 2020;10(1):16605. Published 2020 Oct 6. doi:10.1038/s41598-020-73676-y","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"109","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":109,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.67,"specificity":0.82},"tp":139.0,"fp":9.0,"fn":70.0,"tn":41.0,"sample_size":259.0,"observed_prevalence":0.806949806949807,"sensitivity":0.6650717703349283,"specificity":0.82,"ppv_observed":0.9391891891891891,"npv_observed":0.36936936936936937,"youden_j":0.4850717703349283,"lr_positive":3.6948431685273784,"lr_negative":0.4084490605671607,"diagnostic_odds_ratio":9.046031746031746,"baseline_entropy_bits_observed":0.7078087969775162,"conditional_entropy_bits_observed":0.5961686555247447,"information_bits_observed":0.11164014145277146,"information_fraction_observed":0.15772641132675516,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"288b82a17c67","condition_context_id":"condition:sepsis"},{"id":"diagnostics-2024:110:d8521d2daac2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"WHO partograph alert line","test_or_feature":"WHO partograph alert line","target_condition":"Severe adverse birth outcome","citation":"Souza, JP, Oladapo, OT, Fawole, B, Mugerwa, K, Reis, R, Barbosa-Junior, F, Oliveira-Ciabati, L, Alves, D, Gülmezoglu, AM. Cervical dilatation over time is a poor predictor of severe adverse birth outcomes: a diagnostic accuracy study. BJOG 2018; 125: 991– 1000.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"110","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":110,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.57,"specificity":0.51},"tp":110.0,"fp":4053.0,"fn":84.0,"tn":4242.0,"sample_size":8489.0,"observed_prevalence":0.022853104016963128,"sensitivity":0.5670103092783505,"specificity":0.5113924050632911,"ppv_observed":0.026423252462166705,"npv_observed":0.9805825242718447,"youden_j":0.07840271434164148,"lr_positive":1.160461513808023,"lr_negative":0.8466877615596612,"diagnostic_odds_ratio":1.3705896866518628,"baseline_entropy_bits_observed":0.15717334349081444,"conditional_entropy_bits_observed":0.15677636549613144,"information_bits_observed":0.00039697799468299544,"information_fraction_observed":0.0025257336000248398,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"20f46b68c5ef"},{"id":"diagnostics-2024:111:efb5bc2ff082","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"WHO partograph action line","test_or_feature":"WHO partograph action line","target_condition":"Severe adverse birth outcome","citation":"Souza, JP, Oladapo, OT, Fawole, B, Mugerwa, K, Reis, R, Barbosa-Junior, F, Oliveira-Ciabati, L, Alves, D, Gülmezoglu, AM. Cervical dilatation over time is a poor predictor of severe adverse birth outcomes: a diagnostic accuracy study. BJOG 2018; 125: 991– 1000.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"111","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":111,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.2,"specificity":0.85},"tp":38.0,"fp":1230.0,"fn":156.0,"tn":7065.0,"sample_size":8489.0,"observed_prevalence":0.022853104016963128,"sensitivity":0.1958762886597938,"specificity":0.8517179023508138,"ppv_observed":0.02996845425867508,"npv_observed":0.9783963439966764,"youden_j":0.04759419101060769,"lr_positive":1.3209705808398295,"lr_negative":0.9441197714886073,"diagnostic_odds_ratio":1.3991557223264541,"baseline_entropy_bits_observed":0.15717334349081444,"conditional_entropy_bits_observed":0.15690687961785774,"information_bits_observed":0.0002664638729567015,"information_fraction_observed":0.0016953502867505916,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bd74fe44852b"},{"id":"diagnostics-2024:112:871d50616766","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Prenatal US","test_or_feature":"Prenatal US","target_condition":"Cleft lip","citation":"Sommerlad M, Patel N, Vijayalakshmi B, et al. Detection of lip, alveolar ridge and hard palate abnormalities using two-dimensional ultrasound enhanced with the three-dimensional reverse-face view. Ultrasound Obstet Gynecol. 2010;36(5):596-600. doi:10.1002/uog.7739","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"112","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":112,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.92,"specificity":0.95},"tp":72.0,"fp":6.0,"fn":6.0,"tn":116.0,"sample_size":200.0,"observed_prevalence":0.39,"sensitivity":0.9230769230769231,"specificity":0.9508196721311475,"ppv_observed":0.9230769230769231,"npv_observed":0.9508196721311475,"youden_j":0.8738965952080706,"lr_positive":18.76923076923075,"lr_negative":0.08090185676392568,"diagnostic_odds_ratio":232.0,"baseline_entropy_bits_observed":0.9647995485050872,"conditional_entropy_bits_observed":0.3251569135331438,"information_bits_observed":0.6396426349719434,"information_fraction_observed":0.6629798241127294,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"64a975069b26"},{"id":"diagnostics-2024:113:591dff3a1e61","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Prenatal US","test_or_feature":"Prenatal US","target_condition":"Cleft alveolar ridge","citation":"Sommerlad M, Patel N, Vijayalakshmi B, et al. Detection of lip, alveolar ridge and hard palate abnormalities using two-dimensional ultrasound enhanced with the three-dimensional reverse-face view. Ultrasound Obstet Gynecol. 2010;36(5):596-600. doi:10.1002/uog.7739","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"113","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":113,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.85,"specificity":0.93},"tp":90.0,"fp":7.0,"fn":16.0,"tn":87.0,"sample_size":200.0,"observed_prevalence":0.53,"sensitivity":0.8490566037735849,"specificity":0.925531914893617,"ppv_observed":0.9278350515463918,"npv_observed":0.8446601941747572,"youden_j":0.7745885186672019,"lr_positive":11.401617250673848,"lr_negative":0.1630882671871611,"diagnostic_odds_ratio":69.91071428571429,"baseline_entropy_bits_observed":0.9974015885677396,"conditional_entropy_bits_observed":0.5022337636455477,"information_bits_observed":0.4951678249221919,"information_fraction_observed":0.49645782661450216,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9a512ddbaa10"},{"id":"diagnostics-2024:114:b40bb2d5cd47","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Prenatal US","test_or_feature":"Prenatal US","target_condition":"Cleft secondary hard palate","citation":"Sommerlad M, Patel N, Vijayalakshmi B, et al. Detection of lip, alveolar ridge and hard palate abnormalities using two-dimensional ultrasound enhanced with the three-dimensional reverse-face view. Ultrasound Obstet Gynecol. 2010;36(5):596-600. doi:10.1002/uog.7739","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"114","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":114,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.79,"specificity":0.92},"tp":27.0,"fp":5.0,"fn":7.0,"tn":61.0,"sample_size":100.0,"observed_prevalence":0.34,"sensitivity":0.7941176470588235,"specificity":0.9242424242424242,"ppv_observed":0.84375,"npv_observed":0.8970588235294118,"youden_j":0.7183600713012477,"lr_positive":10.482352941176464,"lr_negative":0.22275795564127296,"diagnostic_odds_ratio":47.05714285714286,"baseline_entropy_bits_observed":0.9248187049730301,"conditional_entropy_bits_observed":0.5252940812643333,"information_bits_observed":0.3995246237086968,"information_fraction_observed":0.43200318241870755,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bce380bc11ed"},{"id":"diagnostics-2024:115:a52382b0b153","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal CT","test_or_feature":"Abdominal CT","target_condition":"Nephrolithiasis","citation":"Smith-Bindman R, Aubin C, Bailitz J, et al. Ultrasonography versus computed tomography for suspected nephrolithiasis. N Engl J Med. 2014;371(12):1100-1110. doi:10.1056/NEJMoa1404446","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"115","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":115,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.86,"specificity":0.53},"tp":236.0,"fp":266.0,"fn":38.0,"tn":299.0,"sample_size":839.0,"observed_prevalence":0.3265792610250298,"sensitivity":0.8613138686131386,"specificity":0.5292035398230088,"ppv_observed":0.4701195219123506,"npv_observed":0.887240356083086,"youden_j":0.3905174084361476,"lr_positive":1.8294824652873056,"lr_negative":0.2620657666674805,"diagnostic_odds_ratio":6.981005144440047,"baseline_entropy_bits_observed":0.9113931767126181,"conditional_entropy_bits_observed":0.800910657631434,"information_bits_observed":0.11048251908118412,"information_fraction_observed":0.1212237724663388,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"90c635390fd3"},{"id":"diagnostics-2024:116:2621186b866c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"SASQ-Modified (5,4)","test_or_feature":"SASQ-Modified (5,4)","target_condition":"AUD (DSM4)","citation":"Smith PC, Schmidt SM, Allensworth-Davies D, Saitz R. Primary care validation of a single-question alcohol screening test [published correction appears in J Gen Intern Med. 2010 Apr;25(4):375]. J Gen Intern Med. 2009;24(7):783-788. doi:10.1007/s11606-009-0928-6","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"116","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":116,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.88,"specificity":0.67},"tp":29.0,"fp":83.0,"fn":4.0,"tn":170.0,"sample_size":286.0,"observed_prevalence":0.11538461538461539,"sensitivity":0.8787878787878788,"specificity":0.6719367588932806,"ppv_observed":0.25892857142857145,"npv_observed":0.9770114942528736,"youden_j":0.5507246376811594,"lr_positive":2.678714859437751,"lr_negative":0.1803921568627451,"diagnostic_odds_ratio":14.849397590361447,"baseline_entropy_bits_observed":0.5159469300074474,"conditional_entropy_bits_observed":0.41919489071407945,"information_bits_observed":0.09675203929336795,"information_fraction_observed":0.18752323866326986,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"74f55509a714"},{"id":"diagnostics-2024:117:715dbb5e89c3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Symmetrical chest rise","test_or_feature":"Symmetrical chest rise","target_condition":"Endotracheal intubation","citation":"Sitzwohl C, Langheinrich A, Schober A, Krafft P, Sessler D I, Herkner H et al. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial BMJ 2010; 341 :c5943 doi:10.1136/bmj.c5944","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"117","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":117,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.43,"specificity":0.9},"tp":34.0,"fp":8.0,"fn":46.0,"tn":72.0,"sample_size":160.0,"observed_prevalence":0.5,"sensitivity":0.425,"specificity":0.9,"ppv_observed":0.8095238095238095,"npv_observed":0.6101694915254238,"youden_j":0.32499999999999996,"lr_positive":4.250000000000001,"lr_negative":0.6388888888888888,"diagnostic_odds_ratio":6.6521739130434785,"baseline_entropy_bits_observed":1.0,"conditional_entropy_bits_observed":0.8958564056026537,"information_bits_observed":0.10414359439734633,"information_fraction_observed":0.10414359439734633,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"af631fa63004"},{"id":"diagnostics-2024:118:229297ba7c39","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Auscultation","test_or_feature":"Auscultation","target_condition":"Endotracheal intubation","citation":"Sitzwohl C, Langheinrich A, Schober A, Krafft P, Sessler D I, Herkner H et al. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial BMJ 2010; 341 :c5943 doi:10.1136/bmj.c5943","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"118","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":118,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.65,"specificity":0.93},"tp":52.0,"fp":6.0,"fn":28.0,"tn":74.0,"sample_size":160.0,"observed_prevalence":0.5,"sensitivity":0.65,"specificity":0.925,"ppv_observed":0.896551724137931,"npv_observed":0.7254901960784313,"youden_j":0.5750000000000002,"lr_positive":8.666666666666671,"lr_negative":0.37837837837837834,"diagnostic_odds_ratio":22.904761904761905,"baseline_entropy_bits_observed":1.0,"conditional_entropy_bits_observed":0.7144509711042051,"information_bits_observed":0.2855490288957949,"information_fraction_observed":0.2855490288957949,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1184ef11e1a4"},{"id":"diagnostics-2024:119:e48d6ab7465a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Left-sided abdominal pain","test_or_feature":"Left-sided abdominal pain","target_condition":"Diverticulitis","citation":"Sigurdardottir J., Chabok A., Wagner P., & Nikberg M. Increased accuracy in diagnosing diverticulitis using predictive clinical factors. Upsala Journal of Medical Sciences. 2022; 127(1). doi: https://doi.org/10.48101/ujms.v127.8803","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"119","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":119,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.98,"specificity":0.07},"tp":101.0,"fp":40.0,"fn":2.0,"tn":3.0,"sample_size":146.0,"observed_prevalence":0.7054794520547946,"sensitivity":0.9805825242718447,"specificity":0.06976744186046512,"ppv_observed":0.7163120567375887,"npv_observed":0.6,"youden_j":0.05034996613230969,"lr_positive":1.0541262135922331,"lr_negative":0.27831715210355973,"diagnostic_odds_ratio":3.7875,"baseline_entropy_bits_observed":0.8744893619480877,"conditional_entropy_bits_observed":0.8642123979936812,"information_bits_observed":0.01027696395440647,"information_fraction_observed":0.011751959945530523,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"24d0bff6bd95"},{"id":"diagnostics-2024:120:8adbb1eac42b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"VAS scale pain > 5/10","test_or_feature":"VAS scale pain > 5/10","target_condition":"Diverticulitis","citation":"Sigurdardottir J., Chabok A., Wagner P., & Nikberg M. Increased accuracy in diagnosing diverticulitis using predictive clinical factors. Upsala Journal of Medical Sciences. 2022; 127(1). doi: https://doi.org/10.48101/ujms.v127.8803","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"120","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":120,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.79,"specificity":0.29},"tp":72.0,"fp":25.0,"fn":19.0,"tn":10.0,"sample_size":126.0,"observed_prevalence":0.7222222222222222,"sensitivity":0.7912087912087912,"specificity":0.2857142857142857,"ppv_observed":0.7422680412371134,"npv_observed":0.3448275862068966,"youden_j":0.07692307692307687,"lr_positive":1.1076923076923075,"lr_negative":0.730769230769231,"diagnostic_odds_ratio":1.5157894736842106,"baseline_entropy_bits_observed":0.8524051786494786,"conditional_entropy_bits_observed":0.8477149682407509,"information_bits_observed":0.004690210408727746,"information_fraction_observed":0.005502325098679896,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6614de4a0a4d"},{"id":"diagnostics-2024:121:57ec4ae7a392","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Vanillylmandelic acid to creatinine ratio","test_or_feature":"Vanillylmandelic acid to creatinine ratio","target_condition":"Neuroblastoma","citation":"Sies CW, Florkowski CM, Sullivan M, Mackay R, George PM. Urinary VMA, dopamine and the likelihood of neuroblastoma: a preferred way of reporting laboratory results?. Ann Clin Biochem. 2006;43(Pt 4):300-305. doi:10.1258/000456306777695645","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"121","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":121,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.95,"specificity":0.97},"tp":19.0,"fp":2.0,"fn":1.0,"tn":57.0,"sample_size":79.0,"observed_prevalence":0.25316455696202533,"sensitivity":0.95,"specificity":0.9661016949152542,"ppv_observed":0.9047619047619048,"npv_observed":0.9827586206896551,"youden_j":0.9161016949152541,"lr_positive":28.02499999999998,"lr_negative":0.05175438596491233,"diagnostic_odds_ratio":541.5,"baseline_entropy_bits_observed":0.8162554088088008,"conditional_entropy_bits_observed":0.21286341813841458,"information_bits_observed":0.6033919906703862,"information_fraction_observed":0.7392195924936583,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2a523f24ea56"},{"id":"diagnostics-2024:122:6fda34dcd1f9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transesophageal echocardiography","test_or_feature":"Transesophageal echocardiography","target_condition":"Infective endocarditis","citation":"Shively BK, Gurule FT, Roldan CA, Leggett JH, Schiller NB. Diagnostic value of transesophageal compared with transthoracic echocardiography in infective endocarditis. J Am Coll Cardiol. 1991;18(2):391-397. doi:10.1016/0735-1097(91)90591-v","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"122","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":122,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1991,"source_reported":{"sensitivity":0.94,"specificity":0.98},"tp":15.0,"fp":1.0,"fn":1.0,"tn":49.0,"sample_size":66.0,"observed_prevalence":0.24242424242424243,"sensitivity":0.9375,"specificity":0.98,"ppv_observed":0.9375,"npv_observed":0.98,"youden_j":0.9175,"lr_positive":46.87499999999996,"lr_negative":0.06377551020408163,"diagnostic_odds_ratio":735.0,"baseline_entropy_bits_observed":0.7990485210442682,"conditional_entropy_bits_observed":0.1889192150448978,"information_bits_observed":0.6101293059993703,"information_fraction_observed":0.763569783224176,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0a5a4c05efb5","condition_context_id":"condition:endocarditis"},{"id":"diagnostics-2024:123:36ed8a9e61bd","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transthoracic echocardiography","test_or_feature":"Transthoracic echocardiography","target_condition":"Infective endocarditis","citation":"Shively BK, Gurule FT, Roldan CA, Leggett JH, Schiller NB. Diagnostic value of transesophageal compared with transthoracic echocardiography in infective endocarditis. J Am Coll Cardiol. 1991;18(2):391-397. doi:10.1016/0735-1097(91)90591-v","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"123","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":123,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1991,"source_reported":{"sensitivity":0.69,"specificity":0.92},"tp":11.0,"fp":4.0,"fn":5.0,"tn":46.0,"sample_size":66.0,"observed_prevalence":0.24242424242424243,"sensitivity":0.6875,"specificity":0.92,"ppv_observed":0.7333333333333333,"npv_observed":0.9019607843137255,"youden_j":0.6074999999999999,"lr_positive":8.593750000000004,"lr_negative":0.33967391304347827,"diagnostic_odds_ratio":25.3,"baseline_entropy_bits_observed":0.7990485210442682,"conditional_entropy_bits_observed":0.5477244411606723,"information_bits_observed":0.25132407988359584,"information_fraction_observed":0.31452918472978714,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8b2bcb602be6","condition_context_id":"condition:endocarditis"},{"id":"diagnostics-2024:124:61dfd8827d47","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Thoracic aortic dissection","citation":"Shiga T, Wajima Z, Apfel CC, Inoue T, Ohe Y. Diagnostic accuracy of transesophageal echocardiography, helical computed tomography, and magnetic resonance imaging for suspected thoracic aortic dissection: systematic review and meta-analysis. Arch Intern Med. 2006;166(13):1350-1356. doi:10.1001/archinte.166.13.1370","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"124","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":124,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.93,"specificity":0.99},"tp":644.0,"fp":19.0,"fn":46.0,"tn":2693.0,"sample_size":3402.0,"observed_prevalence":0.20282186948853614,"sensitivity":0.9333333333333333,"specificity":0.9929941002949852,"ppv_observed":0.971342383107089,"npv_observed":0.9832055494706097,"youden_j":0.9263274336283187,"lr_positive":133.2210526315789,"lr_negative":0.06713702190865205,"diagnostic_odds_ratio":1984.3157894736842,"baseline_entropy_bits_observed":0.7275360592098339,"conditional_entropy_bits_observed":0.13562671617983846,"information_bits_observed":0.5919093430299954,"information_fraction_observed":0.8135807641931306,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9c653ad3e54a"},{"id":"diagnostics-2024:125:c143482786f6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Helical CT","test_or_feature":"Helical CT","target_condition":"Thoracic aortic dissection","citation":"Shiga T, Wajima Z, Apfel CC, Inoue T, Ohe Y. Diagnostic accuracy of transesophageal echocardiography, helical computed tomography, and magnetic resonance imaging for suspected thoracic aortic dissection: systematic review and meta-analysis. Arch Intern Med. 2006;166(13):1350-1356. doi:10.1001/archinte.166.13.1363","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"125","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":125,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.98,"specificity":0.99},"tp":207.0,"fp":8.0,"fn":5.0,"tn":719.0,"sample_size":939.0,"observed_prevalence":0.22577209797657083,"sensitivity":0.9764150943396226,"specificity":0.9889958734525447,"ppv_observed":0.9627906976744186,"npv_observed":0.9930939226519337,"youden_j":0.9654109677921672,"lr_positive":88.73172169811312,"lr_negative":0.02384732463851791,"diagnostic_odds_ratio":3720.825,"baseline_entropy_bits_observed":0.7705679972097454,"conditional_entropy_bits_observed":0.09838952148809621,"information_bits_observed":0.6721784757216492,"information_fraction_observed":0.8723155881838226,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"21ffde9dbaff"},{"id":"diagnostics-2024:126:a990ab41c5d1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TEE","test_or_feature":"TEE","target_condition":"Thoracic aortic dissection","citation":"Shiga T, Wajima Z, Apfel CC, Inoue T, Ohe Y. Diagnostic accuracy of transesophageal echocardiography, helical computed tomography, and magnetic resonance imaging for suspected thoracic aortic dissection: systematic review and meta-analysis. Arch Intern Med. 2006;166(13):1350-1356. doi:10.1001/archinte.166.13.1360","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"126","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":126,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.95,"specificity":0.99},"tp":1258.0,"fp":40.0,"fn":69.0,"tn":5509.0,"sample_size":6876.0,"observed_prevalence":0.19299011052937753,"sensitivity":0.9480030143180106,"specificity":0.9927914939628762,"ppv_observed":0.9691833590138675,"npv_observed":0.9876299749013984,"youden_j":0.9407945082808868,"lr_positive":131.511718161267,"lr_negative":0.05237452778169526,"diagnostic_odds_ratio":2510.986231884058,"baseline_entropy_bits_observed":0.707684799802032,"conditional_entropy_bits_observed":0.11544451031113857,"information_bits_observed":0.5922402894908935,"information_fraction_observed":0.8368701569633359,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"51cc86ab61e1"},{"id":"diagnostics-2024:127:f57ba2a4767c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Cardiac troponin I (< 5ng/L)","test_or_feature":"Cardiac troponin I (< 5ng/L)","target_condition":"MI/cardiac death, 1y","citation":"Shah AS, Anand A, Sandoval Y, et al. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study. Lancet. 2015;386(10012):2481-2488. doi:10.1016/S0140-6736(15)00391-9","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"127","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":127,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.8,"specificity":0.6},"tp":48.0,"fp":1405.0,"fn":12.0,"tn":2148.0,"sample_size":3613.0,"observed_prevalence":0.016606698034874065,"sensitivity":0.8,"specificity":0.6045595271601464,"ppv_observed":0.03303509979353063,"npv_observed":0.9944444444444445,"youden_j":0.40455952716014654,"lr_positive":2.023060498220641,"lr_negative":0.3308193668528863,"diagnostic_odds_ratio":6.115302491103203,"baseline_entropy_bits_observed":0.12193866454112216,"conditional_entropy_bits_observed":0.11386997904158096,"information_bits_observed":0.008068685499541206,"information_fraction_observed":0.06617003335164583,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a2e6430f00a2"},{"id":"diagnostics-2024:128:3acb23c49029","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Cardiac troponin I (< 5ng/L)","test_or_feature":"Cardiac troponin I (< 5ng/L)","target_condition":"MI/cardiac death, 30d","citation":"Shah AS, Anand A, Sandoval Y, et al. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study. Lancet. 2015;386(10012):2481-2488. doi:10.1016/S0140-6736(15)00391-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"128","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":128,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":1.0,"specificity":0.6},"tp":12.0,"fp":1441.0,"fn":0.0,"tn":2160.0,"sample_size":3613.0,"observed_prevalence":0.0033213396069748133,"sensitivity":1.0,"specificity":0.5998333796167731,"ppv_observed":0.008258774948382657,"npv_observed":1.0,"youden_j":0.599833379616773,"lr_positive":2.4989590562109645,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.03213168751496373,"conditional_entropy_bits_observed":0.02775503220317002,"information_bits_observed":0.004376655311793709,"information_fraction_observed":0.13620994259188846,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"53cce3853546"},{"id":"diagnostics-2024:129:7afa5f58660f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Recurrent soft-tissue sarcoma","citation":"Sedaghat, S., Sedaghat, M., Meschede, J. et al. Diagnostic value of MRI for detecting recurrent soft-tissue sarcoma in a long-term analysis at a multidisciplinary sarcoma center. BMC Cancer 21, 398 (2021). https://doi.org/10.1186/s12885-021-08113-y","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"129","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":129,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.92,"specificity":0.98},"tp":65.0,"fp":23.0,"fn":6.0,"tn":961.0,"sample_size":1055.0,"observed_prevalence":0.06729857819905213,"sensitivity":0.9154929577464789,"specificity":0.9766260162601627,"ppv_observed":0.7386363636363636,"npv_observed":0.9937952430196484,"youden_j":0.8921189740066415,"lr_positive":39.167176974892925,"lr_negative":0.08652958332722661,"diagnostic_odds_ratio":452.6449275362319,"baseline_entropy_bits_observed":0.35576063076170916,"conditional_entropy_bits_observed":0.11901219610438453,"information_bits_observed":0.23674843465732465,"information_fraction_observed":0.665471146007441,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"30c6be7a3a85"},{"id":"diagnostics-2024:130:13a532b4ccc7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Stridor","test_or_feature":"Stridor","target_condition":"Post-extubation stridor","citation":"Schweiger C, Eneas LV, Manica D, et al. Accuracy of stridor-based diagnosis of post-intubation subglottic stenosis in pediatric patients. J Pediatr (Rio J). 2020;96(1):39-45. doi:10.1016/j.jped.2018.08.004","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"130","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":130,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.78,"specificity":0.6},"tp":65.0,"fp":42.0,"fn":18.0,"tn":62.0,"sample_size":187.0,"observed_prevalence":0.44385026737967914,"sensitivity":0.7831325301204819,"specificity":0.5961538461538461,"ppv_observed":0.6074766355140186,"npv_observed":0.775,"youden_j":0.37928637627432815,"lr_positive":1.9391853126792884,"lr_negative":0.36377769141080457,"diagnostic_odds_ratio":5.330687830687831,"baseline_entropy_bits_observed":0.99088374604556,"conditional_entropy_bits_observed":0.8820382580877344,"information_bits_observed":0.10884548795782556,"information_fraction_observed":0.10984688001211894,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8c411c9a10be"},{"id":"diagnostics-2024:131:6fbadbfd279f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urine ketone dip test","test_or_feature":"Urine ketone dip test","target_condition":"Diabetic ketoacidosis","citation":"Schwab TM, Hendey GW, Soliz TC. Screening for ketonemia in patients with diabetes. Ann Emerg Med. 1999;34(3):342-346. doi:10.1016/s0196-0644(99)70128-9","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"131","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":131,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.99,"specificity":0.69},"tp":97.0,"fp":186.0,"fn":1.0,"tn":413.0,"sample_size":697.0,"observed_prevalence":0.1406025824964132,"sensitivity":0.9897959183673469,"specificity":0.6894824707846411,"ppv_observed":0.34275618374558303,"npv_observed":0.9975845410628019,"youden_j":0.679278389151988,"lr_positive":3.1875685758174237,"lr_negative":0.014799624450264384,"diagnostic_odds_ratio":215.38172043010752,"baseline_entropy_bits_observed":0.5858147480150903,"conditional_entropy_bits_observed":0.39110134343137326,"information_bits_observed":0.194713404583717,"information_fraction_observed":0.3323805097831052,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2753f77b5f0f"},{"id":"diagnostics-2024:132:4e55c26bf595","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"FDG PET scan","test_or_feature":"FDG PET scan","target_condition":"Cervical lymph node metastsis of head/neck cancer","citation":"Schöder H, Carlson DL, Kraus DH, et al. 18F-FDG PET/CT for detecting nodal metastases in patients with oral cancer staged N0 by clinical examination and CT/MRI. J Nucl Med. 2006;47(5):755-762.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"132","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":132,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.67,"specificity":0.95},"tp":6.0,"fp":6.0,"fn":3.0,"tn":127.0,"sample_size":142.0,"observed_prevalence":0.06338028169014084,"sensitivity":0.6666666666666666,"specificity":0.9548872180451128,"ppv_observed":0.5,"npv_observed":0.9769230769230769,"youden_j":0.6215538847117794,"lr_positive":14.777777777777779,"lr_negative":0.3490813648293964,"diagnostic_odds_ratio":42.333333333333336,"baseline_entropy_bits_observed":0.34071973264102695,"conditional_entropy_bits_observed":0.22950685191176454,"information_bits_observed":0.11121288072926241,"information_fraction_observed":0.3264057525145844,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"23cb6ac495d0"},{"id":"diagnostics-2024:133:3f8c4e0b8685","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"HOMA-IR","test_or_feature":"HOMA-IR","target_condition":"Insulin resistance","citation":"Sánchez-García A, Rodríguez-Gutiérrez R, Mancillas-Adame L, et al. Diagnostic Accuracy of the Triglyceride and Glucose Index for Insulin Resistance: A Systematic Review. Int J Endocrinol. 2020;2020:4678526. Published 2020 Mar 10. doi:10.1155/2020/4678526","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"133","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":133,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.91,"specificity":1.0},"tp":567.0,"fp":15.0,"fn":57.0,"tn":4899.0,"sample_size":5538.0,"observed_prevalence":0.11267605633802817,"sensitivity":0.9086538461538461,"specificity":0.996947496947497,"ppv_observed":0.9742268041237113,"npv_observed":0.988498789346247,"youden_j":0.9056013431013432,"lr_positive":297.67500000000103,"lr_negative":0.09162584200857318,"diagnostic_odds_ratio":3248.8105263157895,"baseline_entropy_bits_observed":0.5079353563991224,"conditional_entropy_bits_observed":0.09922098503214027,"information_bits_observed":0.4087143713669821,"information_fraction_observed":0.8046582428607805,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ba780dcc1e69"},{"id":"diagnostics-2024:134:2655986f9fe0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hyperinsulinemic-euglycemia clamp","test_or_feature":"Hyperinsulinemic-euglycemia clamp","target_condition":"Insulin resistance","citation":"Sánchez-García A, Rodríguez-Gutiérrez R, Mancillas-Adame L, et al. Diagnostic Accuracy of the Triglyceride and Glucose Index for Insulin Resistance: A Systematic Review. Int J Endocrinol. 2020;2020:4678526. Published 2020 Mar 10. doi:10.1155/2020/4678526","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"134","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":134,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.67,"specificity":0.72},"tp":135.0,"fp":79.0,"fn":67.0,"tn":202.0,"sample_size":483.0,"observed_prevalence":0.41821946169772256,"sensitivity":0.6683168316831684,"specificity":0.7188612099644128,"ppv_observed":0.6308411214953271,"npv_observed":0.7509293680297398,"youden_j":0.3871780416475812,"lr_positive":2.3771775911768396,"lr_negative":0.46140084305460244,"diagnostic_odds_ratio":5.152087662951067,"baseline_entropy_bits_observed":0.9806153715936556,"conditional_entropy_bits_observed":0.871929255969339,"information_bits_observed":0.10868611562431663,"information_fraction_observed":0.11083460322234642,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5fa5440f49aa"},{"id":"diagnostics-2024:135:93443acc6df9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid immunoassay chromatographic test","test_or_feature":"Rapid immunoassay chromatographic test","target_condition":"Hepatitis B","citation":"Saboor Soomro R, Shah IA, Saboor A, Bhutto AUB, Memon S. Sensitivity and Specificity of Hepatitis B Virus Screening via Rapid Immunoassay Chromatographic Test. Cureus. 2021;13(1):e12909. Published 2021 Jan 25. doi:10.7759/cureus.12909","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"135","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":135,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.91,"specificity":0.98},"tp":32.0,"fp":2.0,"fn":3.0,"tn":114.0,"sample_size":151.0,"observed_prevalence":0.23178807947019867,"sensitivity":0.9142857142857143,"specificity":0.9827586206896551,"ppv_observed":0.9411764705882353,"npv_observed":0.9743589743589743,"youden_j":0.8970443349753694,"lr_positive":53.02857142857132,"lr_negative":0.08721804511278199,"diagnostic_odds_ratio":608.0,"baseline_entropy_bits_observed":0.7811153285444683,"conditional_entropy_bits_observed":0.20597390514454209,"information_bits_observed":0.5751414233999262,"information_fraction_observed":0.7363079463203542,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"62d355be1e7a"},{"id":"diagnostics-2024:136:e29439ed16b9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"T2 hyperintensities on brain MRI","test_or_feature":"T2 hyperintensities on brain MRI","target_condition":"Neurofibromatosis type 1","citation":"Sabol Z, Resić B, Gjergja Juraski R, et al. Clinical sensitivity and specificity of multiple T2-hyperintensities on brain magnetic resonance imaging in diagnosis of neurofibromatosis type 1 in children: diagnostic accuracy study. Croat Med J. 2011;52(4):488-496. doi:10.3325/cmj.2011.52.488","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"136","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":136,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.73,"specificity":0.96},"tp":119.0,"fp":7.0,"fn":43.0,"tn":156.0,"sample_size":325.0,"observed_prevalence":0.49846153846153846,"sensitivity":0.7345679012345679,"specificity":0.9570552147239264,"ppv_observed":0.9444444444444444,"npv_observed":0.7839195979899497,"youden_j":0.6916231159584942,"lr_positive":17.10493827160495,"lr_negative":0.27734251345362454,"diagnostic_odds_ratio":61.674418604651166,"baseline_entropy_bits_observed":0.9999931706635867,"conditional_entropy_bits_observed":0.5810419722043881,"information_bits_observed":0.4189511984591986,"information_fraction_observed":0.41895405963741356,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e1b433d170a4"},{"id":"diagnostics-2024:137:cd833fcbd17a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Self-diagnosis (bacterial infection)","test_or_feature":"Self-diagnosis (bacterial infection)","target_condition":"Vaginal Candida infection","citation":"Ryan-Wenger NA, Neal JL, Jones AS, Lowe NK. Accuracy of vaginal symptom self-diagnosis algorithms for deployed military women. Nurs Res. 2010;59(1):2-10. doi:10.1097/NNR.0b013e3181c3b9dd","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"137","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":137,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.6,"specificity":0.5},"tp":193.0,"fp":109.0,"fn":127.0,"tn":107.0,"sample_size":536.0,"observed_prevalence":0.5970149253731343,"sensitivity":0.603125,"specificity":0.49537037037037035,"ppv_observed":0.6390728476821192,"npv_observed":0.45726495726495725,"youden_j":0.09849537037037037,"lr_positive":1.1951834862385322,"lr_negative":0.8011682242990654,"diagnostic_odds_ratio":1.491800910207325,"baseline_entropy_bits_observed":0.9726699911457106,"conditional_entropy_bits_observed":0.9658346143661907,"information_bits_observed":0.006835376779519953,"information_fraction_observed":0.007027436686381723,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"27625ef272d5"},{"id":"diagnostics-2024:138:8ab4fe1c0aec","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Self-diagnosis (yeast infection)","test_or_feature":"Self-diagnosis (yeast infection)","target_condition":"Vaginal Candida infection","citation":"Ryan-Wenger NA, Neal JL, Jones AS, Lowe NK. Accuracy of vaginal symptom self-diagnosis algorithms for deployed military women. Nurs Res. 2010;59(1):2-10. doi:10.1097/NNR.0b013e3181c3b9dd","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"138","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":138,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.18,"specificity":0.89},"tp":26.0,"fp":43.0,"fn":122.0,"tn":345.0,"sample_size":536.0,"observed_prevalence":0.27611940298507465,"sensitivity":0.17567567567567569,"specificity":0.8891752577319587,"ppv_observed":0.37681159420289856,"npv_observed":0.7387580299785867,"youden_j":0.06485093340763437,"lr_positive":1.5851665619107473,"lr_negative":0.9270661966314141,"diagnostic_odds_ratio":1.7098741898589402,"baseline_entropy_bits_observed":0.8501091888128283,"conditional_entropy_bits_observed":0.8449821946473259,"information_bits_observed":0.00512699416550233,"information_fraction_observed":0.006030983117194796,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f724f3f0e1fa"},{"id":"diagnostics-2024:139:4b5da50f7949","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"24-hour urinary copper","test_or_feature":"24-hour urinary copper","target_condition":"Wilson's disease","citation":"Ryan A, Nevitt SJ, Tuohy O, Cook P. Biomarkers for diagnosis of Wilson's disease. Cochrane Database Syst Rev. 2019;2019(11):CD012267. Published 2019 Nov 19. doi:10.1002/14651858.CD012267.pub4","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"139","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":139,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.75,"specificity":0.89},"tp":149.0,"fp":38.0,"fn":49.0,"tn":296.0,"sample_size":532.0,"observed_prevalence":0.37218045112781956,"sensitivity":0.7525252525252525,"specificity":0.8862275449101796,"ppv_observed":0.7967914438502673,"npv_observed":0.8579710144927536,"youden_j":0.6387527974354321,"lr_positive":6.614300903774587,"lr_negative":0.2792451542451543,"diagnostic_odds_ratio":23.68635875402793,"baseline_entropy_bits_observed":0.9523316000461215,"conditional_entropy_bits_observed":0.638306505030195,"information_bits_observed":0.31402509501592646,"information_fraction_observed":0.32974343705566234,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"db16c082032e"},{"id":"diagnostics-2024:140:09cd85735784","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hepatic copper content","test_or_feature":"Hepatic copper content","target_condition":"Wilson's disease","citation":"Ryan A, Nevitt SJ, Tuohy O, Cook P. Biomarkers for diagnosis of Wilson's disease. Cochrane Database Syst Rev. 2019;2019(11):CD012267. Published 2019 Nov 19. doi:10.1002/14651858.CD012267.pub3","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"140","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":140,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.92,"specificity":0.94},"tp":633.0,"fp":93.0,"fn":53.0,"tn":1403.0,"sample_size":2182.0,"observed_prevalence":0.31439046746104493,"sensitivity":0.922740524781341,"specificity":0.9378342245989305,"ppv_observed":0.871900826446281,"npv_observed":0.9635989010989011,"youden_j":0.8605747493802716,"lr_positive":14.843223925514913,"lr_negative":0.08238073765296777,"diagnostic_odds_ratio":180.1783323189288,"baseline_entropy_bits_observed":0.8981766596570382,"conditional_entropy_bits_observed":0.33422821724677443,"information_bits_observed":0.5639484424102638,"information_fraction_observed":0.6278814266066579,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"54ae6a31ff39"},{"id":"diagnostics-2024:141:a2529c3a8915","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ceruloplasmin","test_or_feature":"Ceruloplasmin","target_condition":"Wilson's disease","citation":"Ryan A, Nevitt SJ, Tuohy O, Cook P. Biomarkers for diagnosis of Wilson's disease. Cochrane Database Syst Rev. 2019;2019(11):CD012267. Published 2019 Nov 19. doi:10.1002/14651858.CD012267.pub2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"141","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":141,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.92,"specificity":0.88},"tp":986.0,"fp":1001.0,"fn":84.0,"tn":7233.0,"sample_size":9304.0,"observed_prevalence":0.11500429922613929,"sensitivity":0.9214953271028037,"specificity":0.8784308962837017,"ppv_observed":0.49622546552591845,"npv_observed":0.988519885198852,"youden_j":0.7999262233865054,"lr_positive":7.580012510853633,"lr_negative":0.08936920733243667,"diagnostic_odds_ratio":84.81682603111175,"baseline_entropy_bits_observed":0.5148283099828876,"conditional_entropy_bits_observed":0.28469075797134685,"information_bits_observed":0.2301375520115408,"information_fraction_observed":0.4470180593199902,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7414baf89cbd"},{"id":"diagnostics-2024:142:e4a3d65cf02c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Albumin levels","test_or_feature":"Albumin levels","target_condition":"Liver disease","citation":"Rondana M, Milani L, Merkel C, Caregaro L, Gatta A. Value of prealbumin plasma levels as liver test. Digestion. 1987;37(2):72-78. doi:10.1159/000199474","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"142","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":142,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1987,"source_reported":{"sensitivity":0.42,"specificity":0.86},"tp":42.0,"fp":9.0,"fn":58.0,"tn":56.0,"sample_size":165.0,"observed_prevalence":0.6060606060606061,"sensitivity":0.42,"specificity":0.8615384615384616,"ppv_observed":0.8235294117647058,"npv_observed":0.49122807017543857,"youden_j":0.2815384615384615,"lr_positive":3.033333333333334,"lr_negative":0.6732142857142858,"diagnostic_odds_ratio":4.505747126436781,"baseline_entropy_bits_observed":0.9672947789468944,"conditional_entropy_bits_observed":0.8985559026243216,"information_bits_observed":0.0687388763225728,"information_fraction_observed":0.0710630076980356,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"be4b01d68d13"},{"id":"diagnostics-2024:143:fc7edb9d6cb4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Apolipoprotein A levels","test_or_feature":"Apolipoprotein A levels","target_condition":"Liver disease","citation":"Rondana M, Milani L, Merkel C, Caregaro L, Gatta A. Value of prealbumin plasma levels as liver test. Digestion. 1987;37(2):72-78. doi:10.1159/000199473","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"143","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":143,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1987,"source_reported":{"sensitivity":0.53,"specificity":0.86},"tp":53.0,"fp":9.0,"fn":47.0,"tn":56.0,"sample_size":165.0,"observed_prevalence":0.6060606060606061,"sensitivity":0.53,"specificity":0.8615384615384616,"ppv_observed":0.8548387096774194,"npv_observed":0.5436893203883495,"youden_j":0.3915384615384616,"lr_positive":3.8277777777777793,"lr_negative":0.5455357142857142,"diagnostic_odds_ratio":7.016548463356974,"baseline_entropy_bits_observed":0.9672947789468944,"conditional_entropy_bits_observed":0.8453519077269854,"information_bits_observed":0.12194287121990899,"information_fraction_observed":0.1260658838174126,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f01a4a2084b5"},{"id":"diagnostics-2024:144:c7331970fc67","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Prothrombin activity","test_or_feature":"Prothrombin activity","target_condition":"Liver disease","citation":"Rondana M, Milani L, Merkel C, Caregaro L, Gatta A. Value of prealbumin plasma levels as liver test. Digestion. 1987;37(2):72-78. doi:10.1159/000199472","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"144","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":144,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1987,"source_reported":{"sensitivity":0.63,"specificity":0.89},"tp":63.0,"fp":7.0,"fn":37.0,"tn":58.0,"sample_size":165.0,"observed_prevalence":0.6060606060606061,"sensitivity":0.63,"specificity":0.8923076923076924,"ppv_observed":0.9,"npv_observed":0.6105263157894737,"youden_j":0.5223076923076924,"lr_positive":5.850000000000002,"lr_negative":0.41465517241379307,"diagnostic_odds_ratio":14.108108108108109,"baseline_entropy_bits_observed":0.9672947789468944,"conditional_entropy_bits_observed":0.7542624369516328,"information_bits_observed":0.21303234199526166,"information_fraction_observed":0.22023518231659697,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"16ed5b7818a7"},{"id":"diagnostics-2024:145:1beb6e6e1799","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transthyretin levels","test_or_feature":"Transthyretin levels","target_condition":"Liver disease","citation":"Rondana M, Milani L, Merkel C, Caregaro L, Gatta A. Value of prealbumin plasma levels as liver test. Digestion. 1987;37(2):72-78. doi:10.1159/000199471","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"145","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":145,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1987,"source_reported":{"sensitivity":0.84,"specificity":0.89},"tp":84.0,"fp":7.0,"fn":16.0,"tn":58.0,"sample_size":165.0,"observed_prevalence":0.6060606060606061,"sensitivity":0.84,"specificity":0.8923076923076924,"ppv_observed":0.9230769230769231,"npv_observed":0.7837837837837838,"youden_j":0.7323076923076923,"lr_positive":7.800000000000003,"lr_negative":0.17931034482758623,"diagnostic_odds_ratio":43.5,"baseline_entropy_bits_observed":0.9672947789468944,"conditional_entropy_bits_observed":0.5535746401782142,"information_bits_observed":0.4137201387686802,"information_fraction_observed":0.4277084377723018,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f3eec312bae0"},{"id":"diagnostics-2024:146:ada814ed6ed6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum lipase","test_or_feature":"Serum lipase","target_condition":"Acute pancreatitis","citation":"Rompianesi G, Hann A, Komolafe O, Pereira SP, Davidson BR, Gurusamy KS. Serum amylase and lipase and urinary trypsinogen and amylase for diagnosis of acute pancreatitis. Cochrane Database of Systematic Reviews. 2017;4. doi: 10.1002/14651858.CD012010.pub2.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"146","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":146,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.75,"specificity":0.94},"tp":227.0,"fp":19.0,"fn":77.0,"tn":311.0,"sample_size":634.0,"observed_prevalence":0.4794952681388013,"sensitivity":0.7467105263157895,"specificity":0.9424242424242424,"ppv_observed":0.9227642276422764,"npv_observed":0.8015463917525774,"youden_j":0.6891347687400318,"lr_positive":12.969182825484756,"lr_negative":0.2687637502115417,"diagnostic_odds_ratio":48.25495557074505,"baseline_entropy_bits_observed":0.99878651470097,"conditional_entropy_bits_observed":0.5921535466363848,"information_bits_observed":0.40663296806458527,"information_fraction_observed":0.40712701070691615,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5122700bb1b5","condition_context_id":"condition:pancreatitis"},{"id":"diagnostics-2024:147:e6807b44e545","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum amylase","test_or_feature":"Serum amylase","target_condition":"Acute pancreatitis","citation":"Rompianesi G, Hann A, Komolafe O, Pereira SP, Davidson BR, Gurusamy KS. Serum amylase and lipase and urinary trypsinogen and amylase for diagnosis of acute pancreatitis. Cochrane Database of Systematic Reviews. 2017;4. doi: 10.1002/14651858.CD012010.pub2.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"147","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":147,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.76,"specificity":0.91},"tp":198.0,"fp":37.0,"fn":61.0,"tn":353.0,"sample_size":649.0,"observed_prevalence":0.39907550077041604,"sensitivity":0.7644787644787645,"specificity":0.9051282051282051,"ppv_observed":0.8425531914893617,"npv_observed":0.8526570048309179,"youden_j":0.6696069696069697,"lr_positive":8.058019409370761,"lr_negative":0.26020759731807885,"diagnostic_odds_ratio":30.967656180770934,"baseline_entropy_bits_observed":0.9704072275166029,"conditional_entropy_bits_observed":0.6122089617679491,"information_bits_observed":0.35819826574865377,"information_fraction_observed":0.36912159719309723,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b3b88b38bb6e","condition_context_id":"condition:pancreatitis"},{"id":"diagnostics-2024:148:61e41d2c0a38","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urinary trypsinogen","test_or_feature":"Urinary trypsinogen","target_condition":"Acute pancreatitis","citation":"Rompianesi G, Hann A, Komolafe O, Pereira SP, Davidson BR, Gurusamy KS. Serum amylase and lipase and urinary trypsinogen and amylase for diagnosis of acute pancreatitis. Cochrane Database of Systematic Reviews. 2017;4. doi: 10.1002/14651858.CD012010.pub2.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"148","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":148,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.7,"specificity":0.9},"tp":248.0,"fp":50.0,"fn":107.0,"tn":436.0,"sample_size":841.0,"observed_prevalence":0.4221165279429251,"sensitivity":0.6985915492957746,"specificity":0.897119341563786,"ppv_observed":0.8322147651006712,"npv_observed":0.8029465930018416,"youden_j":0.5957108908595607,"lr_positive":6.790309859154931,"lr_negative":0.33597364000516866,"diagnostic_odds_ratio":20.210841121495328,"baseline_entropy_bits_observed":0.9824262258537348,"conditional_entropy_bits_observed":0.6935366778396534,"information_bits_observed":0.2888895480140814,"information_fraction_observed":0.2940572435991664,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"084bab77c784","condition_context_id":"condition:pancreatitis"},{"id":"diagnostics-2024:149:5fae975e964e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NEXUS Criteria for Chest CT, major criteria","test_or_feature":"NEXUS Criteria for Chest CT, major criteria","target_condition":"Major and minor chest injury","citation":"Rodriguez RM, Langdorf MI, Nishijima D, Baumann BM, Hendey GW, et al. Derivation and Validation of Two Decision Instruments for Selective Chest CT in Blunt Trauma: A Multicenter Prospective Observational Study (NEXUS Chest CT). PLOS Medicine. 2015;12(10): e1001883. doi: https://doi.org/10.1371/journal.pmed.1001886","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"149","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":149,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.91,"specificity":0.38},"tp":636.0,"fp":1196.0,"fn":65.0,"tn":731.0,"sample_size":2628.0,"observed_prevalence":0.2667427701674277,"sensitivity":0.9072753209700428,"specificity":0.3793461338868708,"ppv_observed":0.3471615720524017,"npv_observed":0.9183417085427136,"youden_j":0.2866214548569137,"lr_positive":1.4618056383856792,"lr_negative":0.2444329090160431,"diagnostic_odds_ratio":5.980396192436326,"baseline_entropy_bits_observed":0.8367517884337066,"conditional_entropy_bits_observed":0.7729399525709592,"information_bits_observed":0.06381183586274741,"information_fraction_observed":0.07626136776139444,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d4e7a748aa6a"},{"id":"diagnostics-2024:150:8fe1eae1ee0d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NEXUS Criteria for Chest CT, major criteria","test_or_feature":"NEXUS Criteria for Chest CT, major criteria","target_condition":"Major chest injury","citation":"Rodriguez RM, Langdorf MI, Nishijima D, Baumann BM, Hendey GW, et al. Derivation and Validation of Two Decision Instruments for Selective Chest CT in Blunt Trauma: A Multicenter Prospective Observational Study (NEXUS Chest CT). PLOS Medicine. 2015;12(10): e1001883. doi: https://doi.org/10.1371/journal.pmed.1001885","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"150","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":150,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.99,"specificity":0.32},"tp":117.0,"fp":1715.0,"fn":1.0,"tn":795.0,"sample_size":2628.0,"observed_prevalence":0.04490106544901065,"sensitivity":0.9915254237288136,"specificity":0.31673306772908366,"ppv_observed":0.0638646288209607,"npv_observed":0.9987437185929648,"youden_j":0.3082584914578972,"lr_positive":1.4511538271482927,"lr_negative":0.026756209359343284,"diagnostic_odds_ratio":54.23615160349854,"baseline_entropy_bits_observed":0.26432881511364825,"conditional_entropy_bits_observed":0.2430438827817246,"information_bits_observed":0.02128493233192366,"information_fraction_observed":0.08052444952992431,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c74052d918b1"},{"id":"diagnostics-2024:151:c89771a25119","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NEXUS Criteria for Chest CT, all criteria","test_or_feature":"NEXUS Criteria for Chest CT, all criteria","target_condition":"Major and minor chest injury","citation":"Rodriguez RM, Langdorf MI, Nishijima D, Baumann BM, Hendey GW, et al. Derivation and Validation of Two Decision Instruments for Selective Chest CT in Blunt Trauma: A Multicenter Prospective Observational Study (NEXUS Chest CT). PLOS Medicine. 2015;12(10): e1001883. doi: https://doi.org/10.1371/journal.pmed.1001884","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"151","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":151,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.95,"specificity":0.25},"tp":669.0,"fp":1436.0,"fn":32.0,"tn":491.0,"sample_size":2628.0,"observed_prevalence":0.2667427701674277,"sensitivity":0.9543509272467903,"specificity":0.25480020757654387,"ppv_observed":0.3178147268408551,"npv_observed":0.9388145315487572,"youden_j":0.20915113482333414,"lr_positive":1.2806645103095855,"lr_negative":0.17915634052023452,"diagnostic_odds_ratio":7.148306928969359,"baseline_entropy_bits_observed":0.8367517884337066,"conditional_entropy_bits_observed":0.7885817327710267,"information_bits_observed":0.048170055662679845,"information_fraction_observed":0.05756791479686956,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ae2ff89e698e"},{"id":"diagnostics-2024:152:5ac1b236f0d9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NEXUS Criteria for Chest CT, all criteria","test_or_feature":"NEXUS Criteria for Chest CT, all criteria","target_condition":"Major chest injury","citation":"Rodriguez RM, Langdorf MI, Nishijima D, Baumann BM, Hendey GW, et al. Derivation and Validation of Two Decision Instruments for Selective Chest CT in Blunt Trauma: A Multicenter Prospective Observational Study (NEXUS Chest CT). PLOS Medicine. 2015;12(10): e1001883. doi: https://doi.org/10.1371/journal.pmed.1001883","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"152","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":152,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.99,"specificity":0.21},"tp":117.0,"fp":1988.0,"fn":1.0,"tn":522.0,"sample_size":2628.0,"observed_prevalence":0.04490106544901065,"sensitivity":0.9915254237288136,"specificity":0.20796812749003984,"ppv_observed":0.05558194774346793,"npv_observed":0.9980879541108987,"youden_j":0.19949355121885337,"lr_positive":1.2518756607441257,"lr_negative":0.0407493993116435,"diagnostic_odds_ratio":30.72132796780684,"baseline_entropy_bits_observed":0.26432881511364825,"conditional_entropy_bits_observed":0.25201216191904446,"information_bits_observed":0.012316653194603788,"information_fraction_observed":0.046595953563777145,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"79651bc7cc39"},{"id":"diagnostics-2024:153:b2eb952febb7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Glued eye(s)","test_or_feature":"Glued eye(s)","target_condition":"Acute conjunctivitis","citation":"Rietveld RP, ter Riet G, Bindels PJ, Sloos JH, van Weert HC. Predicting bacterial cause in infectious conjunctivitis: cohort study on informativeness of combinations of signs and symptoms. BMJ. 2004;329(7459):206-210. doi:10.1136/bmj.38128.631319.AE","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"153","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":153,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.91,"specificity":0.28},"tp":52.0,"fp":87.0,"fn":5.0,"tn":33.0,"sample_size":177.0,"observed_prevalence":0.3220338983050847,"sensitivity":0.9122807017543859,"specificity":0.275,"ppv_observed":0.37410071942446044,"npv_observed":0.868421052631579,"youden_j":0.18728070175438605,"lr_positive":1.2583182093163945,"lr_negative":0.3189792663476876,"diagnostic_odds_ratio":3.9448275862068964,"baseline_entropy_bits_observed":0.906579548498746,"conditional_entropy_bits_observed":0.8696071114349258,"information_bits_observed":0.03697243706382025,"information_fraction_observed":0.040782341853006616,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"343dfde5bd05"},{"id":"diagnostics-2024:154:44beacfb05a5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Eye burning","test_or_feature":"Eye burning","target_condition":"Acute conjunctivitis","citation":"Rietveld RP, ter Riet G, Bindels PJ, Sloos JH, van Weert HC. Predicting bacterial cause in infectious conjunctivitis: cohort study on informativeness of combinations of signs and symptoms. BMJ. 2004;329(7459):206-210. doi:10.1136/bmj.38128.631319.AE","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"154","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":154,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.65,"specificity":0.43},"tp":37.0,"fp":69.0,"fn":20.0,"tn":51.0,"sample_size":177.0,"observed_prevalence":0.3220338983050847,"sensitivity":0.6491228070175439,"specificity":0.425,"ppv_observed":0.3490566037735849,"npv_observed":0.7183098591549296,"youden_j":0.07412280701754392,"lr_positive":1.1289092295957286,"lr_negative":0.8255933952528379,"diagnostic_odds_ratio":1.367391304347826,"baseline_entropy_bits_observed":0.906579548498746,"conditional_entropy_bits_observed":0.9029457473687754,"information_bits_observed":0.003633801129970582,"information_fraction_observed":0.004008254031307004,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e0e6578fc1e1"},{"id":"diagnostics-2024:155:cc6900c5f168","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Eye itchiness","test_or_feature":"Eye itchiness","target_condition":"Acute conjunctivitis","citation":"Rietveld RP, ter Riet G, Bindels PJ, Sloos JH, van Weert HC. Predicting bacterial cause in infectious conjunctivitis: cohort study on informativeness of combinations of signs and symptoms. BMJ. 2004;329(7459):206-210. doi:10.1136/bmj.38128.631319.AE","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"155","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":155,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.58,"specificity":0.37},"tp":33.0,"fp":76.0,"fn":24.0,"tn":44.0,"sample_size":177.0,"observed_prevalence":0.3220338983050847,"sensitivity":0.5789473684210527,"specificity":0.36666666666666664,"ppv_observed":0.30275229357798167,"npv_observed":0.6470588235294118,"youden_j":-0.05438596491228065,"lr_positive":0.9141274238227147,"lr_negative":1.1483253588516746,"diagnostic_odds_ratio":0.7960526315789473,"baseline_entropy_bits_observed":0.906579548498746,"conditional_entropy_bits_observed":0.9046213356373887,"information_bits_observed":0.0019582128613573335,"information_fraction_observed":0.002160001143418737,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e5f8e664f2c1"},{"id":"diagnostics-2024:156:20c8ea036cf2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Free fluid on TVUS","test_or_feature":"Free fluid on TVUS","target_condition":"Ectopic pregnancy","citation":"Richardson A, Gallos I, Dobson S, Campbell BK, Coomarasamy A, Raine-Fenning N. Accuracy of first-trimester ultrasound in diagnosis of tubal ectopic pregnancy in the absence of an obvious extrauterine embryo: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2016;47(1):28-37. doi:10.1002/uog.14847","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"156","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":156,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.41,"specificity":0.91},"tp":410.0,"fp":211.0,"fn":583.0,"tn":2028.0,"sample_size":3232.0,"observed_prevalence":0.307240099009901,"sensitivity":0.41289023162134947,"specificity":0.905761500669942,"ppv_observed":0.6602254428341385,"npv_observed":0.7767139027192647,"youden_j":0.3186517322912914,"lr_positive":4.381332836967782,"lr_negative":0.6481946604535496,"diagnostic_odds_ratio":6.759285603960557,"baseline_entropy_bits_observed":0.889961897308527,"conditional_entropy_bits_observed":0.7965731501239592,"information_bits_observed":0.0933887471845678,"information_fraction_observed":0.10493566911909298,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e012a3820af0","condition_context_id":"condition:ectopic_pregnancy"},{"id":"diagnostics-2024:157:eb04bf48bfb1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Adnexal mass on TVUS","test_or_feature":"Adnexal mass on TVUS","target_condition":"Ectopic pregnancy","citation":"Richardson A, Gallos I, Dobson S, Campbell BK, Coomarasamy A, Raine-Fenning N. Accuracy of first-trimester ultrasound in diagnosis of tubal ectopic pregnancy in the absence of an obvious extrauterine embryo: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2016;47(1):28-37. doi:10.1002/uog.14846","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"157","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":157,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.55,"specificity":0.92},"tp":605.0,"fp":138.0,"fn":494.0,"tn":1550.0,"sample_size":2787.0,"observed_prevalence":0.3943308216720488,"sensitivity":0.5505004549590536,"specificity":0.9182464454976303,"ppv_observed":0.8142664872139973,"npv_observed":0.7583170254403131,"youden_j":0.468746900456684,"lr_positive":6.73365773891944,"lr_negative":0.4895195045349145,"diagnostic_odds_ratio":13.755647479903773,"baseline_entropy_bits_observed":0.9675375838706073,"conditional_entropy_bits_observed":0.7697374280552541,"information_bits_observed":0.19780015581535315,"information_fraction_observed":0.20443666387000609,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"334b78f4ea24","condition_context_id":"condition:ectopic_pregnancy"},{"id":"diagnostics-2024:158:55a215fc0c74","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pseudosac on TVUS","test_or_feature":"Pseudosac on TVUS","target_condition":"Ectopic pregnancy","citation":"Richardson A, Gallos I, Dobson S, Campbell BK, Coomarasamy A, Raine-Fenning N. Accuracy of first-trimester ultrasound in diagnosis of tubal ectopic pregnancy in the absence of an obvious extrauterine embryo: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2016;47(1):28-37. doi:10.1002/uog.14845","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"158","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":158,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.05,"specificity":0.83},"tp":29.0,"fp":217.0,"fn":552.0,"tn":1040.0,"sample_size":1838.0,"observed_prevalence":0.31610446137105547,"sensitivity":0.04991394148020654,"specificity":0.8273667462211615,"ppv_observed":0.11788617886178862,"npv_observed":0.6532663316582915,"youden_j":-0.12271931229863198,"lr_positive":0.28913283152359265,"lr_negative":1.1483251688070966,"diagnostic_odds_ratio":0.25178654912175247,"baseline_entropy_bits_observed":0.9000947891048074,"conditional_entropy_bits_observed":0.8765282221048141,"information_bits_observed":0.023566566999993377,"information_fraction_observed":0.026182316890681692,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"279e1a7032a5","condition_context_id":"condition:ectopic_pregnancy"},{"id":"diagnostics-2024:159:ecdc2e190c94","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Empty uterus on TVUS","test_or_feature":"Empty uterus on TVUS","target_condition":"Ectopic pregnancy","citation":"Richardson A, Gallos I, Dobson S, Campbell BK, Coomarasamy A, Raine-Fenning N. Accuracy of first-trimester ultrasound in diagnosis of tubal ectopic pregnancy in the absence of an obvious extrauterine embryo: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2016;47(1):28-37. doi:10.1002/uog.14844","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"159","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":159,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.51,"specificity":0.7},"tp":379.0,"fp":536.0,"fn":361.0,"tn":1223.0,"sample_size":2499.0,"observed_prevalence":0.2961184473789516,"sensitivity":0.5121621621621621,"specificity":0.6952814098919841,"ppv_observed":0.41420765027322404,"npv_observed":0.7720959595959596,"youden_j":0.20744357205414632,"lr_positive":1.6807709762000804,"lr_negative":0.7016408477160726,"diagnostic_odds_ratio":2.3954862116012734,"baseline_entropy_bits_observed":0.8764942370009694,"conditional_entropy_bits_observed":0.8491497669989854,"information_bits_observed":0.027344470001984034,"information_fraction_observed":0.031197546826487337,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ef39fd1b1e9a","condition_context_id":"condition:ectopic_pregnancy"},{"id":"diagnostics-2024:160:ffe96651b283","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Median nerve US","test_or_feature":"Median nerve US","target_condition":"Carpal tunnel syndrome","citation":"Reza Salman Roghani, Seyed Ebrahim Hashemi, Mohammad Taghi Holisaz, Faeze Gohari, Ahmad Delbari & Johan Lokk. The diagnostic accuracy of median nerve ultrasonography in elderly patients with carpal tunnel syndrome: sensitivity and specificity assessment. Clinical Interventions in Aging. 2018; 13:1953-1962, doi: 10.2147/CIA.S177307","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"160","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":160,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.97,"specificity":0.93},"tp":196.0,"fp":7.0,"fn":7.0,"tn":96.0,"sample_size":306.0,"observed_prevalence":0.6633986928104575,"sensitivity":0.9655172413793104,"specificity":0.9320388349514563,"ppv_observed":0.9655172413793104,"npv_observed":0.9320388349514563,"youden_j":0.8975560763307668,"lr_positive":14.206896551724144,"lr_negative":0.03699712643678156,"diagnostic_odds_ratio":384.0,"baseline_entropy_bits_observed":0.9215291973055202,"conditional_entropy_bits_observed":0.2641511341955685,"information_bits_observed":0.6573780631099517,"information_fraction_observed":0.713355653876268,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"929eb98049e0"},{"id":"diagnostics-2024:161:5050313f0b7b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"c-ANCA","test_or_feature":"c-ANCA","target_condition":"Wegener's granulomatosis","citation":"Rao JK, Weinberger M, Oddone EZ, Allen NB, Landsman P, Feussner JR. The role of antineutrophil cytoplasmic antibody (c-ANCA) testing in the diagnosis of Wegener granulomatosis. A literature review and meta-analysis. Ann Intern Med. 1995;123(12):925-932. doi:10.7326/0003-4819-123-12-199512150-00005","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"161","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":161,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1995,"source_reported":{"sensitivity":0.66,"specificity":0.98},"tp":486.0,"fp":242.0,"fn":250.0,"tn":11848.0,"sample_size":12826.0,"observed_prevalence":0.05738343988772805,"sensitivity":0.6603260869565217,"specificity":0.9799834574028122,"ppv_observed":0.6675824175824175,"npv_observed":0.9793354273433625,"youden_j":0.6403095443593338,"lr_positive":32.989018145885716,"lr_negative":0.3466118845961894,"diagnostic_odds_ratio":95.1756694214876,"baseline_entropy_bits_observed":0.3169693705008161,"conditional_entropy_bits_observed":0.18898691101980472,"information_bits_observed":0.12798245948101136,"information_fraction_observed":0.4037691694904062,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0ebaa3423cfd"},{"id":"diagnostics-2024:162:6f3845f3a494","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Foot X-ray","test_or_feature":"Foot X-ray","target_condition":"Lisfranc injury","citation":"Rankine JJ, Nicholas CM, Wells G, Barron DA. The diagnostic accuracy of radiographs in Lisfranc injury and the potential value of a craniocaudal projection. AJR Am J Roentgenol. 2012;198(4):W365-W369. doi:10.2214/AJR.11.7222","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"162","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":162,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.69,"specificity":0.8},"tp":31.0,"fp":3.0,"fn":14.0,"tn":12.0,"sample_size":60.0,"observed_prevalence":0.75,"sensitivity":0.6888888888888889,"specificity":0.8,"ppv_observed":0.9117647058823529,"npv_observed":0.46153846153846156,"youden_j":0.48888888888888893,"lr_positive":3.444444444444445,"lr_negative":0.3888888888888889,"diagnostic_odds_ratio":8.857142857142858,"baseline_entropy_bits_observed":0.8112781244591328,"conditional_entropy_bits_observed":0.6754612872093835,"information_bits_observed":0.13581683724974936,"information_fraction_observed":0.16741094472416157,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7ab4f2ce033e"},{"id":"diagnostics-2024:163:74a711f59c47","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CXR and HRCT","test_or_feature":"CXR and HRCT","target_condition":"Interstitial lung disease","citation":"Raghu G, Mageto YN, Lockhart D, Schmidt RA, Wood DE, Godwin JD. The accuracy of the clinical diagnosis of new-onset idiopathic pulmonary fibrosis and other interstitial lung disease: A prospective study. Chest. 1999;116(5):1168-1174. doi:10.1378/chest.116.5.1170","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"163","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":163,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.6,"specificity":0.41},"tp":18.0,"fp":17.0,"fn":12.0,"tn":12.0,"sample_size":59.0,"observed_prevalence":0.5084745762711864,"sensitivity":0.6,"specificity":0.41379310344827586,"ppv_observed":0.5142857142857142,"npv_observed":0.5,"youden_j":0.01379310344827589,"lr_positive":1.0235294117647058,"lr_negative":0.9666666666666668,"diagnostic_odds_ratio":1.0588235294117647,"baseline_entropy_bits_observed":0.9997927658541268,"conditional_entropy_bits_observed":0.9996506316246853,"information_bits_observed":0.0001421342294415373,"information_fraction_observed":0.00014216369061253558,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"29da168e82a2"},{"id":"diagnostics-2024:164:3998a0d27db3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"Interstitial lung disease","citation":"Raghu G, Mageto YN, Lockhart D, Schmidt RA, Wood DE, Godwin JD. The accuracy of the clinical diagnosis of new-onset idiopathic pulmonary fibrosis and other interstitial lung disease: A prospective study. Chest. 1999;116(5):1168-1174. doi:10.1378/chest.116.5.1169","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"164","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":164,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.9,"specificity":0.41},"tp":27.0,"fp":17.0,"fn":3.0,"tn":12.0,"sample_size":59.0,"observed_prevalence":0.5084745762711864,"sensitivity":0.9,"specificity":0.41379310344827586,"ppv_observed":0.6136363636363636,"npv_observed":0.8,"youden_j":0.31379310344827593,"lr_positive":1.5352941176470587,"lr_negative":0.2416666666666666,"diagnostic_odds_ratio":6.352941176470588,"baseline_entropy_bits_observed":0.9997927658541268,"conditional_entropy_bits_observed":0.9012725726047813,"information_bits_observed":0.09852019324934547,"information_fraction_observed":0.0985406142293691,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8ac948722171"},{"id":"diagnostics-2024:165:9bf8a32e0213","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CXR and HRCT","test_or_feature":"CXR and HRCT","target_condition":"Idiopathic pulmonary fibrosis","citation":"Raghu G, Mageto YN, Lockhart D, Schmidt RA, Wood DE, Godwin JD. The accuracy of the clinical diagnosis of new-onset idiopathic pulmonary fibrosis and other interstitial lung disease: A prospective study. Chest. 1999;116(5):1168-1174. doi:10.1378/chest.116.5.1168","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"165","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":165,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.79,"specificity":0.9},"tp":23.0,"fp":3.0,"fn":6.0,"tn":27.0,"sample_size":59.0,"observed_prevalence":0.4915254237288136,"sensitivity":0.7931034482758621,"specificity":0.9,"ppv_observed":0.8846153846153846,"npv_observed":0.8181818181818182,"youden_j":0.693103448275862,"lr_positive":7.931034482758623,"lr_negative":0.22988505747126434,"diagnostic_odds_ratio":34.5,"baseline_entropy_bits_observed":0.9997927658541268,"conditional_entropy_bits_observed":0.6099642128183391,"information_bits_observed":0.3898285530357877,"information_fraction_observed":0.3899093555680568,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bd8ffa7dcffb"},{"id":"diagnostics-2024:166:3e1281d9b4c6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"Idiopathic pulmonary fibrosis","citation":"Raghu G, Mageto YN, Lockhart D, Schmidt RA, Wood DE, Godwin JD. The accuracy of the clinical diagnosis of new-onset idiopathic pulmonary fibrosis and other interstitial lung disease: A prospective study. Chest. 1999;116(5):1168-1174. doi:10.1378/chest.116.5.1168","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"166","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":166,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.62,"specificity":0.97},"tp":18.0,"fp":1.0,"fn":11.0,"tn":29.0,"sample_size":59.0,"observed_prevalence":0.4915254237288136,"sensitivity":0.6206896551724138,"specificity":0.9666666666666667,"ppv_observed":0.9473684210526315,"npv_observed":0.725,"youden_j":0.5873563218390805,"lr_positive":18.62068965517242,"lr_negative":0.3923900118906064,"diagnostic_odds_ratio":47.45454545454545,"baseline_entropy_bits_observed":0.9997927658541268,"conditional_entropy_bits_observed":0.6710830484957819,"information_bits_observed":0.32870971735834487,"information_fraction_observed":0.32877785135555254,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c428f6bc6bdf"},{"id":"diagnostics-2024:167:b98054330eae","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Contrast-enhanced CT","test_or_feature":"Contrast-enhanced CT","target_condition":"Sialolithiasis","citation":"Purcell YM, Kavanagh RG, Cahalane AM, Carroll AG, Khoo SG, Killeen RP. The Diagnostic Accuracy of Contrast-Enhanced CT of the Neck for the Investigation of Sialolithiasis. AJNR Am J Neuroradiol. 2017;38(11):2161-2166. doi:10.3174/ajnr.A5353","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"167","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":167,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.97,"specificity":1.0},"tp":30.0,"fp":0.0,"fn":1.0,"tn":61.0,"sample_size":92.0,"observed_prevalence":0.33695652173913043,"sensitivity":0.967741935483871,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9838709677419355,"youden_j":0.967741935483871,"lr_positive":null,"lr_negative":0.032258064516129004,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9218764863469129,"conditional_entropy_bits_observed":0.08027384405054563,"information_bits_observed":0.8416026422963673,"information_fraction_observed":0.9129234282038758,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c3c4ecfef4e0"},{"id":"diagnostics-2024:168:89871513d738","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"Croup","citation":"Porter P, Brisbane J, Tan J, et al. Diagnostic Errors Are Common in Acute Pediatric Respiratory Disease: A Prospective, Single-Blinded Multicenter Diagnostic Accuracy Study in Australian Emergency Departments. Front Pediatr. 2021;9:736018. Published 2021 Nov 18. doi:10.3389/fped.2021.736018","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"168","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":168,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.77,"specificity":0.98},"tp":63.0,"fp":11.0,"fn":19.0,"tn":509.0,"sample_size":602.0,"observed_prevalence":0.1362126245847176,"sensitivity":0.7682926829268293,"specificity":0.9788461538461538,"ppv_observed":0.8513513513513513,"npv_observed":0.9640151515151515,"youden_j":0.747138836772983,"lr_positive":36.319290465631866,"lr_negative":0.23671474435765968,"diagnostic_odds_ratio":153.4306220095694,"baseline_entropy_bits_observed":0.5742334190296702,"conditional_entropy_bits_observed":0.27063458253213235,"information_bits_observed":0.3035988364975378,"information_fraction_observed":0.5287028348342281,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fdfff9f19de5"},{"id":"diagnostics-2024:169:3961ac390a62","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Light's criteria","test_or_feature":"Light's criteria","target_condition":"Exudative pleural effusion","citation":"Porcel JM, Vives M. Classic, abbreviated, and modified Light's criteria: the end of the story?. Chest. 1999;116(6):1833-1836. doi:10.1378/chest.116.6.1833-b","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"169","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":169,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.98,"specificity":0.76},"tp":287.0,"fp":17.0,"fn":5.0,"tn":55.0,"sample_size":364.0,"observed_prevalence":0.8021978021978022,"sensitivity":0.9828767123287672,"specificity":0.7638888888888888,"ppv_observed":0.944078947368421,"npv_observed":0.9166666666666666,"youden_j":0.746765601217656,"lr_positive":4.162771958098307,"lr_negative":0.02241594022415935,"diagnostic_odds_ratio":185.7058823529412,"baseline_entropy_bits_observed":0.7175106531195437,"conditional_entropy_bits_observed":0.3279775243073898,"information_bits_observed":0.38953312881215385,"information_fraction_observed":0.5428952547513662,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"13cf6ace64d8"},{"id":"diagnostics-2024:170:11ad0cc877f8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abbreviated Light's criteria","test_or_feature":"Abbreviated Light's criteria","target_condition":"Exudative pleural effusion","citation":"Porcel JM, Vives M. Classic, abbreviated, and modified Light's criteria: the end of the story?. Chest. 1999;116(6):1833-1836. doi:10.1378/chest.116.6.1833-b","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"170","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":170,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.96,"specificity":0.79},"tp":281.0,"fp":15.0,"fn":11.0,"tn":57.0,"sample_size":364.0,"observed_prevalence":0.8021978021978022,"sensitivity":0.9623287671232876,"specificity":0.7916666666666666,"ppv_observed":0.9493243243243243,"npv_observed":0.8382352941176471,"youden_j":0.7539954337899544,"lr_positive":4.619178082191779,"lr_negative":0.04758471521268931,"diagnostic_odds_ratio":97.07272727272728,"baseline_entropy_bits_observed":0.7175106531195437,"conditional_entropy_bits_observed":0.354505593138966,"information_bits_observed":0.36300505998057764,"information_fraction_observed":0.5059228854684304,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"74ee16a12833"},{"id":"diagnostics-2024:171:3ec2a8dba6d6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CT enteroclysis","test_or_feature":"CT enteroclysis","target_condition":"Small bowel tumor","citation":"Pilleul F, Penigaud M, Milot L, Saurin JC, Chayvialle JA, Valette PJ. Possible small-bowel neoplasms: contrast-enhanced and water-enhanced multidetector CT enteroclysis. Radiology. 2006;241(3):796-801. doi:10.1148/radiol.2413051429","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"171","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":171,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.84,"specificity":0.97},"tp":42.0,"fp":5.0,"fn":8.0,"tn":164.0,"sample_size":219.0,"observed_prevalence":0.228310502283105,"sensitivity":0.84,"specificity":0.9704142011834319,"ppv_observed":0.8936170212765957,"npv_observed":0.9534883720930233,"youden_j":0.8104142011834319,"lr_positive":28.39199999999996,"lr_negative":0.16487804878048784,"diagnostic_odds_ratio":172.2,"baseline_entropy_bits_observed":0.7750544832521991,"conditional_entropy_bits_observed":0.31807174816940337,"information_bits_observed":0.4569827350827957,"information_fraction_observed":0.5896136916275286,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8bf1f14c899f"},{"id":"diagnostics-2024:172:641fff8a7bf7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Galactomannan assay","test_or_feature":"Galactomannan assay","target_condition":"Aspergillosis","citation":"Pfeiffer CD, Fine JP, Safdar N. Diagnosis of invasive aspergillosis using a galactomannan assay: a meta-analysis. Clin Infect Dis. 2006;42(10):1417-1427. doi:10.1086/503427","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"172","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":172,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.71,"specificity":0.89},"tp":163.0,"fp":454.0,"fn":66.0,"tn":3601.0,"sample_size":4284.0,"observed_prevalence":0.0534547152194211,"sensitivity":0.7117903930131004,"specificity":0.888039457459926,"ppv_observed":0.26418152350081037,"npv_observed":0.9820016362148896,"youden_j":0.5998298504730264,"lr_positive":6.357511109401147,"lr_negative":0.32454594732904135,"diagnostic_odds_ratio":19.588940061407023,"baseline_entropy_bits_observed":0.30089491114533146,"conditional_entropy_bits_observed":0.2312900628567392,"information_bits_observed":0.06960484828859226,"information_fraction_observed":0.23132610659198985,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d6bbf807b756"},{"id":"diagnostics-2024:173:ad0067e21d84","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Head CT, >6h","test_or_feature":"Head CT, >6h","target_condition":"SAH","citation":"Perry J J, Stiell I G, Sivilotti M L A, Bullard M J, Emond M, Symington C et al. Sensitivity of computed tomography performed within six hours of onset of headache for diagnosis of subarachnoid haemorrhage: prospective cohort study BMJ 2011; 343 :d4277 doi:10.1136/bmj.d4278","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"173","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":173,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.86,"specificity":1.0},"tp":102.0,"fp":0.0,"fn":17.0,"tn":2060.0,"sample_size":2179.0,"observed_prevalence":0.05461220743460303,"sensitivity":0.8571428571428571,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9918151179585941,"youden_j":0.8571428571428572,"lr_positive":null,"lr_negative":0.1428571428571429,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.30567522856930684,"conditional_entropy_bits_observed":0.0652974554785136,"information_bits_observed":0.24037777309079325,"information_fraction_observed":0.7863829012768417,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"632e5c55b55b","condition_context_id":"condition:sah"},{"id":"diagnostics-2024:174:b959c54829f3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Head CT, <6h","test_or_feature":"Head CT, <6h","target_condition":"SAH","citation":"Perry J J, Stiell I G, Sivilotti M L A, Bullard M J, Emond M, Symington C et al. Sensitivity of computed tomography performed within six hours of onset of headache for diagnosis of subarachnoid haemorrhage: prospective cohort study BMJ 2011; 343 :d4277 doi:10.1136/bmj.d4277","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"174","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":174,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":120.0,"fp":0.0,"fn":0.0,"tn":833.0,"sample_size":953.0,"observed_prevalence":0.1259181532004197,"sensitivity":1.0,"specificity":1.0,"ppv_observed":1.0,"npv_observed":1.0,"youden_j":1.0,"lr_positive":null,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.5461364769608091,"conditional_entropy_bits_observed":0.0,"information_bits_observed":0.5461364769608091,"information_fraction_observed":1.0,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0c71049a44ce","condition_context_id":"condition:sah"},{"id":"diagnostics-2024:175:7670fbcc0969","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Appendicitis","citation":"Pedram A, Asadian F, Roshan N. Diagnostic Accuracy of Abdominal Ultrasonography in Pediatric Acute Appendicitis. Bull Emerg Trauma. 2019;7(3):278-283. doi:10.29252/beat-0703011","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"175","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":175,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.58,"specificity":0.68},"tp":70.0,"fp":38.0,"fn":50.0,"tn":82.0,"sample_size":240.0,"observed_prevalence":0.5,"sensitivity":0.5833333333333334,"specificity":0.6833333333333333,"ppv_observed":0.6481481481481481,"npv_observed":0.6212121212121212,"youden_j":0.2666666666666666,"lr_positive":1.842105263157895,"lr_negative":0.6097560975609756,"diagnostic_odds_ratio":3.0210526315789474,"baseline_entropy_bits_observed":1.0,"conditional_entropy_bits_observed":0.9475197642689479,"information_bits_observed":0.052480235731052094,"information_fraction_observed":0.052480235731052094,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"139c1734de64","condition_context_id":"condition:appendicitis"},{"id":"diagnostics-2024:176:14bcfc061494","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ventilation/perfusion scan","test_or_feature":"Ventilation/perfusion scan","target_condition":"Pulmonary embolism","citation":"Patel P et al. Systematic review and meta-analysis of test accuracy for the diagnosis of suspected pulmonary embolism. Blood Adv 2020; 4 (18): 4296–4311. doi: https://doi.org/10.1182/bloodadvances.2019001055","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"176","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":176,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.96,"specificity":0.95},"tp":86.0,"fp":85.0,"fn":4.0,"tn":1624.0,"sample_size":1799.0,"observed_prevalence":0.0500277932184547,"sensitivity":0.9555555555555556,"specificity":0.9502633118782914,"ppv_observed":0.5029239766081871,"npv_observed":0.9975429975429976,"youden_j":0.905818867433847,"lr_positive":19.212287581699343,"lr_negative":0.046770662287903615,"diagnostic_odds_ratio":410.77647058823527,"baseline_entropy_bits_observed":0.28651500896454907,"conditional_entropy_bits_observed":0.11752918646254995,"information_bits_observed":0.16898582250199912,"information_fraction_observed":0.5897974528898344,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"766ea85e8470","condition_context_id":"condition:pulmonary_embolism"},{"id":"diagnostics-2024:177:38d1dcab4bfa","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Proximal compression ultrasound","test_or_feature":"Proximal compression ultrasound","target_condition":"Pulmonary embolism","citation":"Patel P et al. Systematic review and meta-analysis of test accuracy for the diagnosis of suspected pulmonary embolism. Blood Adv 2020; 4 (18): 4296–4311. doi: https://doi.org/10.1182/bloodadvances.2019001054","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"177","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":177,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.5,"specificity":0.96},"tp":43.0,"fp":65.0,"fn":43.0,"tn":1564.0,"sample_size":1715.0,"observed_prevalence":0.05014577259475218,"sensitivity":0.5,"specificity":0.960098219766728,"ppv_observed":0.39814814814814814,"npv_observed":0.9732420659614188,"youden_j":0.46009821976672804,"lr_positive":12.530769230769227,"lr_negative":0.5207800511508951,"diagnostic_odds_ratio":24.06153846153846,"baseline_entropy_bits_observed":0.28701586612580215,"conditional_entropy_bits_observed":0.22773773286857218,"information_bits_observed":0.05927813325722997,"information_fraction_observed":0.20653260064461984,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"618affc4a648","condition_context_id":"condition:pulmonary_embolism"},{"id":"diagnostics-2024:178:fb31f455d13a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CT pulmonary angiography","test_or_feature":"CT pulmonary angiography","target_condition":"Pulmonary embolism","citation":"Patel P et al. Systematic review and meta-analysis of test accuracy for the diagnosis of suspected pulmonary embolism. Blood Adv 2020; 4 (18): 4296–4311. doi: https://doi.org/10.1182/bloodadvances.2019001053","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"178","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":178,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.94,"specificity":0.98},"tp":206.0,"fp":83.0,"fn":13.0,"tn":4089.0,"sample_size":4391.0,"observed_prevalence":0.04987474379412434,"sensitivity":0.9406392694063926,"specificity":0.9801054650047939,"ppv_observed":0.71280276816609,"npv_observed":0.9968308142369576,"youden_j":0.9207447344111865,"lr_positive":47.28128954172863,"lr_negative":0.06056565615958178,"diagnostic_odds_ratio":780.6617238183503,"baseline_entropy_bits_observed":0.28586463938499757,"conditional_entropy_bits_observed":0.0857784474129737,"information_bits_observed":0.20008619197202387,"information_fraction_observed":0.6999333404875978,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cc2e25c79727","condition_context_id":"condition:pulmonary_embolism"},{"id":"diagnostics-2024:179:e1f17e3d27b4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"D-dimer assay","test_or_feature":"D-dimer assay","target_condition":"Pulmonary embolism","citation":"Patel P et al. Systematic review and meta-analysis of test accuracy for the diagnosis of suspected pulmonary embolism. Blood Adv 2020; 4 (18): 4296–4311. doi: https://doi.org/10.1182/bloodadvances.2019001052","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"179","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":179,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.98,"specificity":0.41},"tp":1120.0,"fp":12818.0,"fn":23.0,"tn":8888.0,"sample_size":22849.0,"observed_prevalence":0.050024071075320586,"sensitivity":0.9798775153105862,"specificity":0.40947203538192206,"ppv_observed":0.08035586167312384,"npv_observed":0.9974189204354169,"youden_j":0.3893495506925082,"lr_positive":1.6593244926924315,"lr_negative":0.04914251267646444,"diagnostic_odds_ratio":33.76556065858473,"baseline_entropy_bits_observed":0.28649920050125177,"conditional_entropy_bits_observed":0.2562003542015157,"information_bits_observed":0.03029884629973606,"information_fraction_observed":0.10575543054474834,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6519702a3809","condition_context_id":"condition:pulmonary_embolism"},{"id":"diagnostics-2024:180:eb7144884f1d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Dynamic CZT-SPECT","test_or_feature":"Dynamic CZT-SPECT","target_condition":"Coronary artery syndrome","citation":"Panjer M, Dobrolinska M, Wagenaar NRL, Slart RHJA. Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis. J Nucl Cardiol. 2022;29(4):1686-1697. doi:10.1007/s12350-021-02721-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"180","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":180,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.79,"specificity":0.83},"tp":150.0,"fp":57.0,"fn":39.0,"tn":273.0,"sample_size":519.0,"observed_prevalence":0.36416184971098264,"sensitivity":0.7936507936507936,"specificity":0.8272727272727273,"ppv_observed":0.7246376811594203,"npv_observed":0.875,"youden_j":0.6209235209235209,"lr_positive":4.594820384294068,"lr_negative":0.24943310657596376,"diagnostic_odds_ratio":18.42105263157895,"baseline_entropy_bits_observed":0.946083697762694,"conditional_entropy_bits_observed":0.6654072680132216,"information_bits_observed":0.2806764297494724,"information_fraction_observed":0.2966718805251778,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c805dbb6e7bd"},{"id":"diagnostics-2024:181:d0fa2571b17a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CATCH Rule - high risk factors","test_or_feature":"CATCH Rule - high risk factors","target_condition":"Need for neurologic intervention","citation":"Osmond MH, Klassen TP, Wells GA, et al. CATCH: a clinical decision rule for the use of computed tomography in children with minor head injury. CMAJ. 2010;182(4):341-348. doi:10.1503/cmaj.091421","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"181","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":181,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":1.0,"specificity":0.7},"tp":24.0,"fp":1144.0,"fn":0.0,"tn":2698.0,"sample_size":3866.0,"observed_prevalence":0.006207966890843249,"sensitivity":1.0,"specificity":0.7022384174908901,"ppv_observed":0.02054794520547945,"npv_observed":1.0,"youden_j":0.7022384174908902,"lr_positive":3.358391608391608,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.05444306921065039,"conditional_entropy_bits_observed":0.04365834854632045,"information_bits_observed":0.010784720664329943,"information_fraction_observed":0.19809170975651366,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"913426aa6abb"},{"id":"diagnostics-2024:182:94f896ab61e4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CATCH Rule - all risk factors","test_or_feature":"CATCH Rule - all risk factors","target_condition":"Brain injury on CT","citation":"Osmond MH, Klassen TP, Wells GA, et al. CATCH: a clinical decision rule for the use of computed tomography in children with minor head injury. CMAJ. 2010;182(4):341-348. doi:10.1503/cmaj.091421","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"182","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":182,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.98,"specificity":0.5},"tp":156.0,"fp":1851.0,"fn":3.0,"tn":1856.0,"sample_size":3866.0,"observed_prevalence":0.041127780651836525,"sensitivity":0.9811320754716981,"specificity":0.500674399784192,"ppv_observed":0.07772795216741404,"npv_observed":0.9983862291554599,"youden_j":0.48180647525589015,"lr_positive":1.9649144266740057,"lr_negative":0.03768501951854261,"diagnostic_odds_ratio":52.140464613722315,"baseline_entropy_bits_observed":0.24743934072654283,"conditional_entropy_bits_observed":0.2129214680776534,"information_bits_observed":0.03451787264888945,"information_fraction_observed":0.1395003419728507,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c1120732a400"},{"id":"diagnostics-2024:183:da6b18cf4d41","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum 1,3-β-d-glucan","test_or_feature":"Serum 1,3-β-d-glucan","target_condition":"Pneumocystis jiroveci pneumonia","citation":"Onishi A, Sugiyama D, Kogata Y, et al. Diagnostic accuracy of serum 1,3-β-D-glucan for pneumocystis jiroveci pneumonia, invasive candidiasis, and invasive aspergillosis: systematic review and meta-analysis. J Clin Microbiol. 2012;50(1):7-15. doi:10.1128/JCM.05267-11","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"183","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":183,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.46,"specificity":0.99},"tp":273.0,"fp":13.0,"fn":321.0,"tn":1724.0,"sample_size":2331.0,"observed_prevalence":0.2548262548262548,"sensitivity":0.4595959595959596,"specificity":0.9925158318940702,"ppv_observed":0.9545454545454546,"npv_observed":0.8430317848410758,"youden_j":0.4521117914900299,"lr_positive":61.40909090909079,"lr_negative":0.5444790128664839,"diagnostic_odds_ratio":112.78504672897196,"baseline_entropy_bits_observed":0.8188383260247876,"conditional_entropy_bits_observed":0.582807400122837,"information_bits_observed":0.23603092590195052,"information_fraction_observed":0.2882509506459099,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fe25c8e341c6"},{"id":"diagnostics-2024:184:580439445ee3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Physical examination with point-of-care US","test_or_feature":"Physical examination with point-of-care US","target_condition":"Splenomegaly","citation":"Olson AP, Trappey B, Wagner M, Newman M, Nixon LJ, Schnobrich D. Point-of-care ultrasonography improves the diagnosis of splenomegaly in hospitalized patients. Crit Ultrasound J. 2015;7(1):13. doi:10.1186/s13089-015-0030-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"184","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":184,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":1.0,"specificity":0.74},"tp":5.0,"fp":9.0,"fn":0.0,"tn":25.0,"sample_size":39.0,"observed_prevalence":0.1282051282051282,"sensitivity":1.0,"specificity":0.7352941176470589,"ppv_observed":0.35714285714285715,"npv_observed":1.0,"youden_j":0.7352941176470589,"lr_positive":3.7777777777777786,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.5524951143251111,"conditional_entropy_bits_observed":0.3375385492663804,"information_bits_observed":0.21495656505873073,"information_fraction_observed":0.38906509665937306,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0cb239760b45"},{"id":"diagnostics-2024:185:eb1e048ae507","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Physical examination alone","test_or_feature":"Physical examination alone","target_condition":"Splenomegaly","citation":"Olson AP, Trappey B, Wagner M, Newman M, Nixon LJ, Schnobrich D. Point-of-care ultrasonography improves the diagnosis of splenomegaly in hospitalized patients. Crit Ultrasound J. 2015;7(1):13. doi:10.1186/s13089-015-0030-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"185","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":185,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.4,"specificity":0.88},"tp":2.0,"fp":4.0,"fn":3.0,"tn":30.0,"sample_size":39.0,"observed_prevalence":0.1282051282051282,"sensitivity":0.4,"specificity":0.8823529411764706,"ppv_observed":0.3333333333333333,"npv_observed":0.9090909090909091,"youden_j":0.2823529411764705,"lr_positive":3.3999999999999995,"lr_negative":0.68,"diagnostic_odds_ratio":5.0,"baseline_entropy_bits_observed":0.5524951143251111,"conditional_entropy_bits_observed":0.5131583480188944,"information_bits_observed":0.03933676630621674,"information_fraction_observed":0.07119839666685152,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"125bff898fd4"},{"id":"diagnostics-2024:186:106046bd88d5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urogenital cytology","test_or_feature":"Urogenital cytology","target_condition":"Endometrial cancer","citation":"O’Flynn, H., Ryan, N.A.J., Narine, N. et al. Diagnostic accuracy of cytology for the detection of endometrial cancer in urine and vaginal samples. Nat Commun 12, 952 (2021). https://doi.org/10.1038/s41467-021-21257-6","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"186","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":186,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.91,"specificity":0.83},"tp":95.0,"fp":14.0,"fn":9.0,"tn":69.0,"sample_size":187.0,"observed_prevalence":0.5561497326203209,"sensitivity":0.9134615384615384,"specificity":0.8313253012048193,"ppv_observed":0.8715596330275229,"npv_observed":0.8846153846153846,"youden_j":0.7447868396663577,"lr_positive":5.415521978021978,"lr_negative":0.10409698996655521,"diagnostic_odds_ratio":52.023809523809526,"baseline_entropy_bits_observed":0.99088374604556,"conditional_entropy_bits_observed":0.5376294130535795,"information_bits_observed":0.4532543329919805,"information_fraction_observed":0.45742432934321264,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e9bf380b7928"},{"id":"diagnostics-2024:187:b92f40aec053","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal CT","test_or_feature":"Abdominal CT","target_condition":"Appendicitis","citation":"Nyamuryekung'e MK, Patel MR, Jusabani A, Zehri AA, Ali A. Diagnostic accuracy of computed tomography in adults with suspected acute appendicitis at the emergency department in a private tertiary hospital in Tanzania. PLoS One. 2022;17(10):e0276720. Published 2022 Oct 27. doi:10.1371/journal.pone.0276720","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"187","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":187,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":1.0,"specificity":0.97},"tp":43.0,"fp":4.0,"fn":0.0,"tn":124.0,"sample_size":171.0,"observed_prevalence":0.25146198830409355,"sensitivity":1.0,"specificity":0.96875,"ppv_observed":0.9148936170212766,"npv_observed":1.0,"youden_j":0.96875,"lr_positive":32.0,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8135871087327387,"conditional_entropy_bits_observed":0.11541690980502191,"information_bits_observed":0.6981701989277167,"information_fraction_observed":0.8581382269136517,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8dde1ce2a11b","condition_context_id":"condition:appendicitis"},{"id":"diagnostics-2024:188:90c1b38a9514","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Noninvasive fractional flow reserve","test_or_feature":"Noninvasive fractional flow reserve","target_condition":"Coronary artery syndrome","citation":"Nørgaard BL, Leipsic J, Gaur S, et al. Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). J Am Coll Cardiol. 2014;63(12):1145-1155. doi:10.1016/j.jacc.2013.11.044","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"188","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":188,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.86,"specificity":0.79},"tp":69.0,"fp":37.0,"fn":11.0,"tn":137.0,"sample_size":254.0,"observed_prevalence":0.31496062992125984,"sensitivity":0.8625,"specificity":0.7873563218390804,"ppv_observed":0.6509433962264151,"npv_observed":0.9256756756756757,"youden_j":0.6498563218390805,"lr_positive":4.056081081081081,"lr_negative":0.17463503649635032,"diagnostic_odds_ratio":23.226044226044227,"baseline_entropy_bits_observed":0.898816907761663,"conditional_entropy_bits_observed":0.6119549648827419,"information_bits_observed":0.2868619428789211,"information_fraction_observed":0.31915503636140713,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b8d6b988a6cf"},{"id":"diagnostics-2024:189:ce0a666a8a91","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Coronary CTA","test_or_feature":"Coronary CTA","target_condition":"Coronary artery syndrome","citation":"Nørgaard BL, Leipsic J, Gaur S, et al. Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). J Am Coll Cardiol. 2014;63(12):1145-1155. doi:10.1016/j.jacc.2013.11.043","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"189","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":189,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.94,"specificity":0.34},"tp":75.0,"fp":115.0,"fn":5.0,"tn":59.0,"sample_size":254.0,"observed_prevalence":0.31496062992125984,"sensitivity":0.9375,"specificity":0.3390804597701149,"ppv_observed":0.39473684210526316,"npv_observed":0.921875,"youden_j":0.2765804597701149,"lr_positive":1.4184782608695652,"lr_negative":0.1843220338983051,"diagnostic_odds_ratio":7.695652173913044,"baseline_entropy_bits_observed":0.898816907761663,"conditional_entropy_bits_observed":0.823599321064175,"information_bits_observed":0.07521758669748801,"information_fraction_observed":0.0836851043276472,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c10513df93b3"},{"id":"diagnostics-2024:190:a711c3670396","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Automated detection of Brugada-type ECG","test_or_feature":"Automated detection of Brugada-type ECG","target_condition":"Ventricular tachycardia","citation":"Nishizaki M, Sugi K, Izumida N, et al. Classification and assessment of computerized diagnostic criteria for Brugada-type electrocardiograms. Heart Rhythm. 2010;7(11):1660-1666. doi:10.1016/j.hrthm.2010.06.038","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"190","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":190,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.88,"specificity":1.0},"tp":480.0,"fp":477.0,"fn":68.0,"tn":192196.0,"sample_size":193221.0,"observed_prevalence":0.002836130648324975,"sensitivity":0.8759124087591241,"specificity":0.9975243028343359,"ppv_observed":0.5015673981191222,"npv_observed":0.9996463196438231,"youden_j":0.87343671159346,"lr_positive":353.80434283615836,"lr_negative":0.12439555696868446,"diagnostic_odds_ratio":2844.187939326674,"baseline_entropy_bits_observed":0.028084805186331375,"conditional_entropy_bits_observed":0.009495433911566455,"information_bits_observed":0.01858937127476492,"information_fraction_observed":0.6619013787502503,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e533d379444f","condition_context_id":"condition:cardiac_arrhythmia"},{"id":"diagnostics-2024:191:f72cc051bbaa","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Automated detection of Brugada Type S ECG","test_or_feature":"Automated detection of Brugada Type S ECG","target_condition":"Ventricular tachycardia","citation":"Nishizaki M, Sugi K, Izumida N, et al. Classification and assessment of computerized diagnostic criteria for Brugada-type electrocardiograms. Heart Rhythm. 2010;7(11):1660-1666. doi:10.1016/j.hrthm.2010.06.037","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"191","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":191,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.76,"specificity":1.0},"tp":16.0,"fp":129.0,"fn":5.0,"tn":192544.0,"sample_size":192694.0,"observed_prevalence":0.0001089810788088887,"sensitivity":0.7619047619047619,"specificity":0.9993304718357009,"ppv_observed":0.1103448275862069,"npv_observed":0.9999740325839137,"youden_j":0.7612352337404626,"lr_positive":1137.97268364709,"lr_negative":0.23825475636490265,"diagnostic_odds_ratio":4776.285271317829,"baseline_entropy_bits_observed":0.0015918050051681647,"conditional_entropy_bits_observed":0.0008096597387515941,"information_bits_observed":0.0007821452664165706,"information_fraction_observed":0.49135746142093684,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1ac7900ce427","condition_context_id":"condition:cardiac_arrhythmia"},{"id":"diagnostics-2024:192:70b4a97f58e6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Automated detection of Brugada Type 2 or 3 ECG","test_or_feature":"Automated detection of Brugada Type 2 or 3 ECG","target_condition":"Ventricular tachycardia","citation":"Nishizaki M, Sugi K, Izumida N, et al. Classification and assessment of computerized diagnostic criteria for Brugada-type electrocardiograms. Heart Rhythm. 2010;7(11):1660-1666. doi:10.1016/j.hrthm.2010.06.036","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"192","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":192,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.86,"specificity":1.0},"tp":306.0,"fp":315.0,"fn":49.0,"tn":192358.0,"sample_size":193028.0,"observed_prevalence":0.0018391114242493317,"sensitivity":0.8619718309859155,"specificity":0.9983651056453161,"ppv_observed":0.4927536231884058,"npv_observed":0.9997453315108078,"youden_j":0.8603369366312315,"lr_positive":527.2339637826805,"lr_negative":0.1382542000252171,"diagnostic_odds_ratio":3813.5113702623908,"baseline_entropy_bits_observed":0.01936242803738027,"conditional_entropy_bits_observed":0.00661357143300572,"information_bits_observed":0.01274885660437455,"information_fraction_observed":0.658432743030066,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7204283548ea","condition_context_id":"condition:cardiac_arrhythmia"},{"id":"diagnostics-2024:193:43ae1a20b1f3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Automated detection of Brugada Type 1 ECG","test_or_feature":"Automated detection of Brugada Type 1 ECG","target_condition":"Ventricular tachycardia","citation":"Nishizaki M, Sugi K, Izumida N, et al. Classification and assessment of computerized diagnostic criteria for Brugada-type electrocardiograms. Heart Rhythm. 2010;7(11):1660-1666. doi:10.1016/j.hrthm.2010.06.035","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"193","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":193,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.92,"specificity":1.0},"tp":158.0,"fp":33.0,"fn":14.0,"tn":192640.0,"sample_size":192845.0,"observed_prevalence":0.0008919080090227903,"sensitivity":0.9186046511627907,"specificity":0.9998287253533188,"ppv_observed":0.8272251308900523,"npv_observed":0.9999273308625827,"youden_j":0.9184333765161095,"lr_positive":5363.342847074054,"lr_negative":0.08140929218496488,"diagnostic_odds_ratio":65881.21212121213,"baseline_entropy_bits_observed":0.01032193449007121,"conditional_entropy_bits_observed":0.0017604796929248643,"information_bits_observed":0.008561454797146347,"information_fraction_observed":0.8294428535059692,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c6b32cbd43a5","condition_context_id":"condition:cardiac_arrhythmia"},{"id":"diagnostics-2024:194:8215aa7891f7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Uterosacral ligament endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub9","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"194","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":194,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.86,"specificity":0.84},"tp":121.0,"fp":9.0,"fn":20.0,"tn":48.0,"sample_size":198.0,"observed_prevalence":0.7121212121212122,"sensitivity":0.8581560283687943,"specificity":0.8421052631578947,"ppv_observed":0.9307692307692308,"npv_observed":0.7058823529411765,"youden_j":0.700261291526689,"lr_positive":5.43498817966903,"lr_negative":0.16843971631205673,"diagnostic_odds_ratio":32.266666666666666,"baseline_entropy_bits_observed":0.8659653498997097,"conditional_entropy_bits_observed":0.5385189406219832,"information_bits_observed":0.3274464092777265,"information_fraction_observed":0.37812876614018,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c88dfc2978ae"},{"id":"diagnostics-2024:195:b9d03b09a45e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Uterosacral ligament endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"195","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":195,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.68,"specificity":0.97},"tp":136.0,"fp":18.0,"fn":63.0,"tn":534.0,"sample_size":751.0,"observed_prevalence":0.26498002663115844,"sensitivity":0.6834170854271356,"specificity":0.967391304347826,"ppv_observed":0.8831168831168831,"npv_observed":0.8944723618090452,"youden_j":0.6508083897749617,"lr_positive":20.958123953098806,"lr_negative":0.3272542487719497,"diagnostic_odds_ratio":64.04232804232804,"baseline_entropy_bits_observed":0.8341686985399236,"conditional_entropy_bits_observed":0.49326069177689363,"information_bits_observed":0.34090800676302996,"information_fraction_observed":0.4086799317209263,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a89737513987"},{"id":"diagnostics-2024:196:35a03395f413","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Deep infiltrating endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub7","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"196","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":196,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.96,"specificity":0.93},"tp":160.0,"fp":3.0,"fn":6.0,"tn":43.0,"sample_size":212.0,"observed_prevalence":0.7830188679245284,"sensitivity":0.963855421686747,"specificity":0.9347826086956522,"ppv_observed":0.9815950920245399,"npv_observed":0.8775510204081632,"youden_j":0.8986380303823993,"lr_positive":14.779116465863464,"lr_negative":0.03866629307929392,"diagnostic_odds_ratio":382.22222222222223,"baseline_entropy_bits_observed":0.7546167018169156,"conditional_entropy_bits_observed":0.22575910075779365,"information_bits_observed":0.5288576010591219,"information_fraction_observed":0.7008294406760067,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b1f549161eb1"},{"id":"diagnostics-2024:197:7b8ef7c14b7e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Deep infiltrating endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub6","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"197","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":197,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.77,"specificity":0.95},"tp":71.0,"fp":9.0,"fn":21.0,"tn":181.0,"sample_size":282.0,"observed_prevalence":0.3262411347517731,"sensitivity":0.7717391304347826,"specificity":0.9526315789473684,"ppv_observed":0.8875,"npv_observed":0.8960396039603961,"youden_j":0.724370709382151,"lr_positive":16.292270531400952,"lr_negative":0.23961085755464812,"diagnostic_odds_ratio":67.994708994709,"baseline_entropy_bits_observed":0.9110397724692714,"conditional_entropy_bits_observed":0.4887972523710077,"information_bits_observed":0.4222425200982637,"information_fraction_observed":0.4634732015637721,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bfca885c4d33"},{"id":"diagnostics-2024:198:a2c5d4482600","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Ovarian endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub5","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"198","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":198,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.95,"specificity":0.91},"tp":72.0,"fp":9.0,"fn":4.0,"tn":94.0,"sample_size":179.0,"observed_prevalence":0.4245810055865922,"sensitivity":0.9473684210526315,"specificity":0.912621359223301,"ppv_observed":0.8888888888888888,"npv_observed":0.9591836734693877,"youden_j":0.8599897802759324,"lr_positive":10.8421052631579,"lr_negative":0.057670772676371836,"diagnostic_odds_ratio":188.0,"baseline_entropy_bits_observed":0.9835250212777537,"conditional_entropy_bits_observed":0.36242535073977544,"information_bits_observed":0.6210996705379782,"information_fraction_observed":0.6315036802328344,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e85793e84001"},{"id":"diagnostics-2024:199:e5c36478796c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Ovarian endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub4","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"199","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":199,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.92,"specificity":0.95},"tp":182.0,"fp":28.0,"fn":16.0,"tn":539.0,"sample_size":765.0,"observed_prevalence":0.25882352941176473,"sensitivity":0.9191919191919192,"specificity":0.9506172839506173,"ppv_observed":0.8666666666666667,"npv_observed":0.9711711711711711,"youden_j":0.8698092031425366,"lr_positive":18.613636363636367,"lr_negative":0.08500590318772133,"diagnostic_odds_ratio":218.96875,"baseline_entropy_bits_observed":0.8249658680139926,"conditional_entropy_bits_observed":0.2922557469794831,"information_bits_observed":0.5327101210345095,"information_fraction_observed":0.6457359530727567,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ac3aea24f825"},{"id":"diagnostics-2024:200:6e36ddb91ebc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Pelvic endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub3","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"200","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":200,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.78,"specificity":0.78},"tp":196.0,"fp":11.0,"fn":56.0,"tn":40.0,"sample_size":303.0,"observed_prevalence":0.8316831683168316,"sensitivity":0.7777777777777778,"specificity":0.7843137254901961,"ppv_observed":0.9468599033816425,"npv_observed":0.4166666666666667,"youden_j":0.5620915032679739,"lr_positive":3.606060606060606,"lr_negative":0.2833333333333333,"diagnostic_odds_ratio":12.727272727272727,"baseline_entropy_bits_observed":0.6538398806263331,"conditional_entropy_bits_observed":0.5151231801626401,"information_bits_observed":0.138716700463693,"information_fraction_observed":0.21215698915583436,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7ee5a07b3adf"},{"id":"diagnostics-2024:201:ba5fb8ca544e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Pelvic endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"201","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":201,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.41,"specificity":0.96},"tp":257.0,"fp":24.0,"fn":372.0,"tn":569.0,"sample_size":1222.0,"observed_prevalence":0.5147299509001637,"sensitivity":0.40858505564387915,"specificity":0.9595278246205734,"ppv_observed":0.9145907473309609,"npv_observed":0.6046758767268863,"youden_j":0.36811288026445244,"lr_positive":10.095455749867526,"lr_negative":0.6163603901637603,"diagnostic_odds_ratio":16.379144265232974,"baseline_entropy_bits_observed":0.9993738621322704,"conditional_entropy_bits_observed":0.8423223753640474,"information_bits_observed":0.157051486768223,"information_fraction_observed":0.15714988426166857,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9643eba02d8f"},{"id":"diagnostics-2024:202:c083dbea0d5f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Rectosigmoid endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub17","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"202","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":202,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.92,"specificity":0.96},"tp":341.0,"fp":10.0,"fn":28.0,"tn":233.0,"sample_size":612.0,"observed_prevalence":0.6029411764705882,"sensitivity":0.924119241192412,"specificity":0.9588477366255144,"ppv_observed":0.9715099715099715,"npv_observed":0.89272030651341,"youden_j":0.8829669778179263,"lr_positive":22.456097560975593,"lr_negative":0.07913744373495234,"diagnostic_odds_ratio":283.7607142857143,"baseline_entropy_bits_observed":0.9692040949598235,"conditional_entropy_bits_observed":0.316790204515464,"information_bits_observed":0.6524138904443595,"information_fraction_observed":0.6731439681663789,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"89b4c61c7dfd"},{"id":"diagnostics-2024:203:39d7df9e5786","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Rectosigmoid endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub16","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"203","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":203,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.86,"specificity":0.95},"tp":578.0,"fp":43.0,"fn":93.0,"tn":901.0,"sample_size":1615.0,"observed_prevalence":0.4154798761609907,"sensitivity":0.8614008941877794,"specificity":0.9544491525423728,"ppv_observed":0.9307568438003221,"npv_observed":0.9064386317907445,"youden_j":0.8158500467301524,"lr_positive":18.910754514261928,"lr_negative":0.14521371352578938,"diagnostic_odds_ratio":130.22705676419105,"baseline_entropy_bits_observed":0.9792884754587478,"conditional_entropy_bits_observed":0.4155034024577112,"information_bits_observed":0.5637850730010365,"information_fraction_observed":0.5757088816315656,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"399c008c78e2"},{"id":"diagnostics-2024:204:89c6e5600e50","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Pouch of Douglas obliteration (endometriosis)","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub15","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"204","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":204,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.9,"specificity":0.96},"tp":74.0,"fp":3.0,"fn":8.0,"tn":69.0,"sample_size":154.0,"observed_prevalence":0.5324675324675324,"sensitivity":0.9024390243902439,"specificity":0.9583333333333334,"ppv_observed":0.961038961038961,"npv_observed":0.8961038961038961,"youden_j":0.8607723577235773,"lr_positive":21.658536585365873,"lr_negative":0.10180275715800634,"diagnostic_odds_ratio":212.75,"baseline_entropy_bits_observed":0.9969562518473081,"conditional_entropy_bits_observed":0.35936690383516495,"information_bits_observed":0.6375893480121431,"information_fraction_observed":0.6395359343308427,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ad2451689853"},{"id":"diagnostics-2024:205:bfb47bf88be0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Pouch of Douglas obliteration (endometriosis)","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub14","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"205","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":205,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.83,"specificity":0.97},"tp":152.0,"fp":17.0,"fn":32.0,"tn":554.0,"sample_size":755.0,"observed_prevalence":0.24370860927152319,"sensitivity":0.8260869565217391,"specificity":0.9702276707530648,"ppv_observed":0.8994082840236687,"npv_observed":0.9453924914675768,"youden_j":0.7963146272748038,"lr_positive":27.746803069053726,"lr_negative":0.17924972531784647,"diagnostic_odds_ratio":154.7941176470588,"baseline_entropy_bits_observed":0.8011533640049265,"conditional_entropy_bits_observed":0.34263725971813946,"information_bits_observed":0.4585161042867871,"information_fraction_observed":0.5723200137295654,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d47f6e708504"},{"id":"diagnostics-2024:206:4ee498f72d13","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"MRI for vaginal wall endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub13","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"206","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":206,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.77,"specificity":0.94},"tp":44.0,"fp":11.0,"fn":13.0,"tn":180.0,"sample_size":248.0,"observed_prevalence":0.22983870967741934,"sensitivity":0.7719298245614035,"specificity":0.9424083769633508,"ppv_observed":0.8,"npv_observed":0.9326424870466321,"youden_j":0.7143382015247544,"lr_positive":13.403508771929822,"lr_negative":0.2420077972709552,"diagnostic_odds_ratio":55.38461538461539,"baseline_entropy_bits_observed":0.7777300323134144,"conditional_entropy_bits_observed":0.4371410473240678,"information_bits_observed":0.34058898498934664,"information_fraction_observed":0.4379270065941005,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"23d9aef75650"},{"id":"diagnostics-2024:207:d14b2e59d830","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Vaginal wall endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub12","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"207","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":207,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.61,"specificity":0.98},"tp":70.0,"fp":11.0,"fn":44.0,"tn":554.0,"sample_size":679.0,"observed_prevalence":0.16789396170839468,"sensitivity":0.6140350877192983,"specificity":0.9805309734513274,"ppv_observed":0.8641975308641975,"npv_observed":0.9264214046822743,"youden_j":0.5945660611706258,"lr_positive":31.539074960127614,"lr_negative":0.3936284755209323,"diagnostic_odds_ratio":80.12396694214875,"baseline_entropy_bits_observed":0.6528643047591333,"conditional_entropy_bits_observed":0.4022815039788984,"information_bits_observed":0.25058280078023487,"information_fraction_observed":0.38382064841588254,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e70e59ab8624"},{"id":"diagnostics-2024:208:939502a2018b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Rectovaginal septum endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub11","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"208","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":208,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.81,"specificity":0.86},"tp":96.0,"fp":23.0,"fn":22.0,"tn":147.0,"sample_size":288.0,"observed_prevalence":0.4097222222222222,"sensitivity":0.8135593220338984,"specificity":0.8647058823529412,"ppv_observed":0.8067226890756303,"npv_observed":0.8698224852071006,"youden_j":0.6782652043868396,"lr_positive":6.013264554163598,"lr_negative":0.21561166839617196,"diagnostic_odds_ratio":27.889328063241106,"baseline_entropy_bits_observed":0.9763543800252756,"conditional_entropy_bits_observed":0.6200495944646738,"information_bits_observed":0.35630478556060186,"information_fraction_observed":0.36493387324321513,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ddf0a790e0de"},{"id":"diagnostics-2024:209:62e18a5c3e0b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TVUS","test_or_feature":"TVUS","target_condition":"Rectovaginal septum endometriosis","citation":"Nisenblat V, Bossuyt PM, Farquhar C, Johnson N, Hull ML. Imaging modalities for the non-invasive diagnosis of endometriosis. Cochrane Database Syst Rev. 2016;2(2):CD009591. Published 2016 Feb 26. doi:10.1002/14651858.CD009591.pub10","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"209","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":209,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.77,"specificity":0.99},"tp":196.0,"fp":10.0,"fn":57.0,"tn":721.0,"sample_size":984.0,"observed_prevalence":0.2571138211382114,"sensitivity":0.7747035573122529,"specificity":0.9863201094391245,"ppv_observed":0.9514563106796117,"npv_observed":0.9267352185089974,"youden_j":0.7610236667513774,"lr_positive":56.630830039525804,"lr_negative":0.22842121997883924,"diagnostic_odds_ratio":247.92280701754385,"baseline_entropy_bits_observed":0.8223597827387397,"conditional_entropy_bits_observed":0.35751370416008393,"information_bits_observed":0.46484607857865573,"information_fraction_observed":0.5652587691369818,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e08b607a39ee"},{"id":"diagnostics-2024:210:839feae3471b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Bacterial meningitis score","test_or_feature":"Bacterial meningitis score","target_condition":"Bacterial meningitis, children","citation":"Nigrovic LE, Kuppermann N, Macias CG, et al. Clinical Prediction Rule for Identifying Children With Cerebrospinal Fluid Pleocytosis at Very Low Risk of Bacterial Meningitis. JAMA. 2007;297(1):52–60. doi:10.1001/jama.297.1.52","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"210","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":210,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2007,"source_reported":{"sensitivity":0.98,"specificity":0.62},"tp":119.0,"fp":1070.0,"fn":2.0,"tn":1712.0,"sample_size":2903.0,"observed_prevalence":0.04168101963486049,"sensitivity":0.9834710743801653,"specificity":0.6153846153846154,"ppv_observed":0.10008410428931876,"npv_observed":0.9988331388564761,"youden_j":0.5988556897647808,"lr_positive":2.5570247933884303,"lr_negative":0.026859504132231315,"diagnostic_odds_ratio":95.2,"baseline_entropy_bits_observed":0.24994721565293274,"conditional_entropy_bits_observed":0.19990447629186905,"information_bits_observed":0.05004273936106368,"information_fraction_observed":0.20021322994272175,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"588daba3e819"},{"id":"diagnostics-2024:211:f55d4168dfaf","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Head CT","test_or_feature":"Head CT","target_condition":"Fungal sinutitis","citation":"Naz N, Ahmad Z, Malik S, Zahid T. Diagnostic Accuracy of C.T Scan in Fungal Sinusitis, Diagnosis and Extent. Ann. Pak. Inst. Med. Sci. 2016; 12(2):61-65.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"211","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":211,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.89,"specificity":0.87},"tp":67.0,"fp":3.0,"fn":8.0,"tn":20.0,"sample_size":98.0,"observed_prevalence":0.7653061224489796,"sensitivity":0.8933333333333333,"specificity":0.8695652173913043,"ppv_observed":0.9571428571428572,"npv_observed":0.7142857142857143,"youden_j":0.7628985507246377,"lr_positive":6.8488888888888875,"lr_negative":0.12266666666666669,"diagnostic_odds_ratio":55.833333333333336,"baseline_entropy_bits_observed":0.786104468844776,"conditional_entropy_bits_observed":0.42892167186917435,"information_bits_observed":0.3571827969756017,"information_fraction_observed":0.4543706480901979,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"31ed91f7f513"},{"id":"diagnostics-2024:212:172e8befc89b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical examination","test_or_feature":"Clinical examination","target_condition":"Fetal presentation","citation":"Nassar N, Roberts CL, Cameron CA, Olive EC. Diagnostic accuracy of clinical examination for detection of non-cephalic presentation in late pregnancy: cross sectional analytic study. BMJ. 2006;333(7568):578-580. doi:10.1136/bmj.38919.681563.4F","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"212","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":212,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.7,"specificity":0.95},"tp":91.0,"fp":74.0,"fn":39.0,"tn":1429.0,"sample_size":1633.0,"observed_prevalence":0.07960808328230251,"sensitivity":0.7,"specificity":0.9507651363938789,"ppv_observed":0.5515151515151515,"npv_observed":0.973433242506812,"youden_j":0.6507651363938789,"lr_positive":14.217567567567576,"lr_negative":0.31553533939818057,"diagnostic_odds_ratio":45.05855855855856,"baseline_entropy_bits_observed":0.400796739707442,"conditional_entropy_bits_observed":0.2592654251734372,"information_bits_observed":0.1415313145340048,"information_fraction_observed":0.3531249147318771,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bfa98dc7aaf0"},{"id":"diagnostics-2024:213:d63d28772a3a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CSF lactate","test_or_feature":"CSF lactate","target_condition":"Bacterial meningitis, children","citation":"Nasir H, Afzal MF, Hamid MH, Laeeq A. Diagnostic accuracy of cerebrospinal fluid lactate in confirmed cases of acute bacterial meningitis in children. Pak J Med Sci. 2020;36(7):1558-1561. doi:10.12669/pjms.36.7.1682","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"213","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":213,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":1.0,"specificity":0.61},"tp":19.0,"fp":91.0,"fn":0.0,"tn":140.0,"sample_size":250.0,"observed_prevalence":0.076,"sensitivity":1.0,"specificity":0.6060606060606061,"ppv_observed":0.17272727272727273,"npv_observed":1.0,"youden_j":0.606060606060606,"lr_positive":2.5384615384615388,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.38792567937193734,"conditional_entropy_bits_observed":0.29211853389681236,"information_bits_observed":0.09580714547512498,"information_fraction_observed":0.24697293984311494,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3a64bd62cd6a"},{"id":"diagnostics-2024:214:7c74a98be9d2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Wayne's criteria","test_or_feature":"Wayne's criteria","target_condition":"Hyperthyroidism","citation":"Naraintran S, Sandeep Kumar DS, Raveendran K, Eashwara Pillai BK. Accuracy of Wayne’s criteria in diagnosing hyperthyroidism: a prospective study in south Kerala, India. International Surgery Journal. 2018;5(4). doi: https://doi.org/10.18203/2349-2902.isj20181056","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"214","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":214,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.87,"specificity":0.97},"tp":20.0,"fp":1.0,"fn":3.0,"tn":30.0,"sample_size":54.0,"observed_prevalence":0.42592592592592593,"sensitivity":0.8695652173913043,"specificity":0.967741935483871,"ppv_observed":0.9523809523809523,"npv_observed":0.9090909090909091,"youden_j":0.8373071528751752,"lr_positive":26.95652173913046,"lr_negative":0.1347826086956522,"diagnostic_odds_ratio":200.0,"baseline_entropy_bits_observed":0.9841095278800531,"conditional_entropy_bits_observed":0.37599082498179015,"information_bits_observed":0.608118702898263,"information_fraction_observed":0.6179380299347967,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"153031768154"},{"id":"diagnostics-2024:215:4cc839e0ed3c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"SLE","citation":"Narain S, Richards HB, Satoh M, et al. Diagnostic Accuracy for Lupus and Other Systemic Autoimmune Diseases in the Community Setting. Arch Intern Med. 2004;164(22):2435–2441. doi:10.1001/archinte.164.22.2435","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"215","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":215,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.88,"specificity":0.52},"tp":118.0,"fp":164.0,"fn":16.0,"tn":178.0,"sample_size":476.0,"observed_prevalence":0.2815126050420168,"sensitivity":0.8805970149253731,"specificity":0.52046783625731,"ppv_observed":0.41843971631205673,"npv_observed":0.9175257731958762,"youden_j":0.4010648511826831,"lr_positive":1.83636694575901,"lr_negative":0.22941472413214825,"diagnostic_odds_ratio":8.004573170731707,"baseline_entropy_bits_observed":0.8575036632820642,"conditional_entropy_bits_observed":0.748457171148489,"information_bits_observed":0.1090464921335752,"information_fraction_observed":0.1271673775902061,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d175df21336f"},{"id":"diagnostics-2024:216:01a979ff71a9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum tryptase","test_or_feature":"Serum tryptase","target_condition":"Anaphylaxis","citation":"Nam YH, Jin HJ, Lee SK. Clinical significance of serum tryptase. Journal of Allergy and Clinical Immunology. 2018;141(2):AB162. doi:10.1016/j.jaci.2017.12.519","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"216","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":216,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.24,"specificity":1.0},"tp":20.0,"fp":0.0,"fn":64.0,"tn":21.0,"sample_size":105.0,"observed_prevalence":0.8,"sensitivity":0.23809523809523808,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.24705882352941178,"youden_j":0.23809523809523814,"lr_positive":null,"lr_negative":0.7619047619047619,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.7219280948873623,"conditional_entropy_bits_observed":0.6529482256509589,"information_bits_observed":0.06897986923640342,"information_fraction_observed":0.09554950101667106,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3537257cc7a9","condition_context_id":"condition:anaphylaxis"},{"id":"diagnostics-2024:217:4c6588337f7e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Colposcopy","test_or_feature":"Colposcopy","target_condition":"Cervical cancer","citation":"Najib FS, Hashemi M, Shiravani Z, Poordast T, Sharifi S, Askary E. Diagnostic Accuracy of Cervical Pap Smear and Colposcopy in Detecting Premalignant and Malignant Lesions of Cervix. Indian J Surg Oncol. 2020;11(3):453-458. doi:10.1007/s13193-020-01118-2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"217","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":217,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.65,"specificity":0.53},"tp":57.0,"fp":34.0,"fn":31.0,"tn":38.0,"sample_size":160.0,"observed_prevalence":0.55,"sensitivity":0.6477272727272727,"specificity":0.5277777777777778,"ppv_observed":0.6263736263736264,"npv_observed":0.5507246376811594,"youden_j":0.1755050505050506,"lr_positive":1.3716577540106951,"lr_negative":0.6674641148325359,"diagnostic_odds_ratio":2.0550284629981026,"baseline_entropy_bits_observed":0.9927744539878083,"conditional_entropy_bits_observed":0.9702981327063989,"information_bits_observed":0.022476321281409417,"information_fraction_observed":0.02263990697093968,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fe67877c9ece"},{"id":"diagnostics-2024:218:90c10cfa2011","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pap smear","test_or_feature":"Pap smear","target_condition":"Cervical cancer","citation":"Najib FS, Hashemi M, Shiravani Z, Poordast T, Sharifi S, Askary E. Diagnostic Accuracy of Cervical Pap Smear and Colposcopy in Detecting Premalignant and Malignant Lesions of Cervix. Indian J Surg Oncol. 2020;11(3):453-458. doi:10.1007/s13193-020-01118-2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"218","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":218,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.47,"specificity":0.64},"tp":41.0,"fp":26.0,"fn":47.0,"tn":46.0,"sample_size":160.0,"observed_prevalence":0.55,"sensitivity":0.4659090909090909,"specificity":0.6388888888888888,"ppv_observed":0.6119402985074627,"npv_observed":0.4946236559139785,"youden_j":0.10479797979797967,"lr_positive":1.29020979020979,"lr_negative":0.8359683794466405,"diagnostic_odds_ratio":1.5433715220949265,"baseline_entropy_bits_observed":0.9927744539878083,"conditional_entropy_bits_observed":0.9846822145327271,"information_bits_observed":0.008092239455081196,"information_fraction_observed":0.008151135862305913,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f51ec18bd21d"},{"id":"diagnostics-2024:219:cfdff99d6d7d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid PCR test","test_or_feature":"Rapid PCR test","target_condition":"Hepatitis C","citation":"Nabeeta R et al. Diagnostic accuracy of various hepatitis c rapid tests against elisa in detection of hepatitis c infection. Makerere University Institutional Repository. Accessed at: http://makir.mak.ac.ug/handle/10570/8598","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"219","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":219,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":null,"source_reported":{"sensitivity":0.66,"specificity":0.86},"tp":111.0,"fp":19.0,"fn":56.0,"tn":114.0,"sample_size":300.0,"observed_prevalence":0.5566666666666666,"sensitivity":0.6646706586826348,"specificity":0.8571428571428571,"ppv_observed":0.8538461538461538,"npv_observed":0.6705882352941176,"youden_j":0.521813515825492,"lr_positive":4.6526946107784415,"lr_negative":0.3912175648702595,"diagnostic_odds_ratio":11.892857142857142,"baseline_entropy_bits_observed":0.9907147546131312,"conditional_entropy_bits_observed":0.7781738455560404,"information_bits_observed":0.21254090905709078,"information_fraction_observed":0.2145328996741215,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1082e5d24c61"},{"id":"diagnostics-2024:220:6b57014b1e00","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NT pro-BNP","test_or_feature":"NT pro-BNP","target_condition":"Congestive heart failure","citation":"Mueller T, Gegenhuber A, Poelz W, Haltmayer M. Diagnostic accuracy of B type natriuretic peptide and amino terminal proBNP in the emergency diagnosis of heart failure. Heart. 2005;91(5):606-612. doi:10.1136/hrt.2004.037762","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"220","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":220,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.87,"specificity":0.81},"tp":118.0,"fp":22.0,"fn":18.0,"tn":93.0,"sample_size":251.0,"observed_prevalence":0.5418326693227091,"sensitivity":0.8676470588235294,"specificity":0.808695652173913,"ppv_observed":0.8428571428571429,"npv_observed":0.8378378378378378,"youden_j":0.6763427109974425,"lr_positive":4.535427807486631,"lr_negative":0.16366223908918404,"diagnostic_odds_ratio":27.71212121212121,"baseline_entropy_bits_observed":0.994944740131452,"conditional_entropy_bits_observed":0.6327489587387677,"information_bits_observed":0.36219578139268427,"information_fraction_observed":0.3640360783703736,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3181aca09b76"},{"id":"diagnostics-2024:221:0a396b2acda9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"BNP","test_or_feature":"BNP","target_condition":"Congestive heart failure","citation":"Mueller T, Gegenhuber A, Poelz W, Haltmayer M. Diagnostic accuracy of B type natriuretic peptide and amino terminal proBNP in the emergency diagnosis of heart failure. Heart. 2005;91(5):606-612. doi:10.1136/hrt.2004.037762","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"221","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":221,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.8,"specificity":0.86},"tp":110.0,"fp":16.0,"fn":27.0,"tn":98.0,"sample_size":251.0,"observed_prevalence":0.545816733067729,"sensitivity":0.8029197080291971,"specificity":0.8596491228070176,"ppv_observed":0.873015873015873,"npv_observed":0.784,"youden_j":0.6625688308362148,"lr_positive":5.72080291970803,"lr_negative":0.22925666617011767,"diagnostic_odds_ratio":24.953703703703702,"baseline_entropy_bits_observed":0.9939345619970958,"conditional_entropy_bits_observed":0.650546654081011,"information_bits_observed":0.34338790791608487,"information_fraction_observed":0.3454834161578217,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4b0e0f7c1a95"},{"id":"diagnostics-2024:222:38b1baf84fd4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Liver stiffness measurement","test_or_feature":"Liver stiffness measurement","target_condition":"Cirrhosis","citation":"Mózes FE, Lee JA, Selvaraj EA, et al. Diagnostic accuracy of non-invasive tests for advanced fibrosis in patients with NAFLD: an individual patient data meta-analysis. Gut. 2022;71(5):1006-1019. doi:10.1136/gutjnl-2021-324243","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"222","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":222,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.83,"specificity":0.72},"tp":502.0,"fp":251.0,"fn":102.0,"tn":654.0,"sample_size":1509.0,"observed_prevalence":0.4002650762094102,"sensitivity":0.8311258278145696,"specificity":0.7226519337016575,"ppv_observed":0.6666666666666666,"npv_observed":0.8650793650793651,"youden_j":0.5537777615162272,"lr_positive":2.9966887417218544,"lr_negative":0.23368673673977758,"diagnostic_odds_ratio":12.823529411764707,"baseline_entropy_bits_observed":0.9711054429218381,"conditional_entropy_bits_observed":0.7441925957570066,"information_bits_observed":0.2269128471648315,"information_fraction_observed":0.23366447878420055,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"19b5fc66cc96"},{"id":"diagnostics-2024:223:74082d34b018","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"FIB-4","test_or_feature":"FIB-4","target_condition":"Cirrhosis","citation":"Mózes FE, Lee JA, Selvaraj EA, et al. Diagnostic accuracy of non-invasive tests for advanced fibrosis in patients with NAFLD: an individual patient data meta-analysis. Gut. 2022;71(5):1006-1019. doi:10.1136/gutjnl-2021-324243","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"223","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":223,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.54,"specificity":0.91},"tp":459.0,"fp":239.0,"fn":396.0,"tn":2311.0,"sample_size":3405.0,"observed_prevalence":0.2511013215859031,"sensitivity":0.5368421052631579,"specificity":0.9062745098039215,"ppv_observed":0.6575931232091691,"npv_observed":0.8537125969708164,"youden_j":0.44311661506707933,"lr_positive":5.72781325699185,"lr_negative":0.5110569587100594,"diagnostic_odds_ratio":11.20777862305059,"baseline_entropy_bits_observed":0.8130190161420181,"conditional_entropy_bits_observed":0.6674282365725952,"information_bits_observed":0.1455907795694229,"information_fraction_observed":0.17907426109205682,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ff4b72a872cc"},{"id":"diagnostics-2024:224:38fe1ed9da8d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Single fiber electromyography","test_or_feature":"Single fiber electromyography","target_condition":"Myasthenia gravis","citation":"Morren JA, Levin KH, Shields RW. Diagnostic Accuracy of Single Fiber Electromyography for Myasthenia Gravis in Patients Followed Longitudinally. J Clin Neurophysiol. 2016;33(5):469-474. doi:10.1097/WNP.0000000000000285","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"224","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":224,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.78,"specificity":0.91},"tp":84.0,"fp":22.0,"fn":24.0,"tn":218.0,"sample_size":348.0,"observed_prevalence":0.3103448275862069,"sensitivity":0.7777777777777778,"specificity":0.9083333333333333,"ppv_observed":0.7924528301886793,"npv_observed":0.9008264462809917,"youden_j":0.6861111111111111,"lr_positive":8.484848484848484,"lr_negative":0.24464831804281345,"diagnostic_odds_ratio":34.68181818181818,"baseline_entropy_bits_observed":0.8935711016541907,"conditional_entropy_bits_observed":0.5487328438564278,"information_bits_observed":0.3448382577977629,"information_fraction_observed":0.3859102618240381,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6153bc358976"},{"id":"diagnostics-2024:225:59c4e8aab19a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Blood culture","test_or_feature":"Blood culture","target_condition":"Typhoid fever","citation":"Moore CE, Pan-Ngum W, Wijedoru LPM, et al. Evaluation of the diagnostic accuracy of a typhoid IgM flow assay for the diagnosis of typhoid fever in Cambodian children using a Bayesian latent class model assuming an imperfect gold standard. Am J Trop Med Hyg. 2014;90(1):114-120. doi:10.4269/ajtmh.13-0384","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"225","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":225,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.75,"specificity":1.0},"tp":24.0,"fp":0.0,"fn":8.0,"tn":456.0,"sample_size":488.0,"observed_prevalence":0.06557377049180328,"sensitivity":0.75,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9827586206896551,"youden_j":0.75,"lr_positive":null,"lr_negative":0.25,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.3491843735073079,"conditional_entropy_bits_observed":0.11947814606571984,"information_bits_observed":0.22970622744158808,"information_fraction_observed":0.6578365037769386,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5acf31de3725"},{"id":"diagnostics-2024:226:704e4033e2f6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PCR test","test_or_feature":"PCR test","target_condition":"Typhoid fever","citation":"Moore CE, Pan-Ngum W, Wijedoru LPM, et al. Evaluation of the diagnostic accuracy of a typhoid IgM flow assay for the diagnosis of typhoid fever in Cambodian children using a Bayesian latent class model assuming an imperfect gold standard. Am J Trop Med Hyg. 2014;90(1):114-120. doi:10.4269/ajtmh.13-0384","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"226","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":226,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.56,"specificity":1.0},"tp":18.0,"fp":0.0,"fn":14.0,"tn":456.0,"sample_size":488.0,"observed_prevalence":0.06557377049180328,"sensitivity":0.5625,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9702127659574468,"youden_j":0.5625,"lr_positive":null,"lr_negative":0.4375,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.3491843735073079,"conditional_entropy_bits_observed":0.1861929293393878,"information_bits_observed":0.1629914441679201,"information_fraction_observed":0.4667776009870869,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b5ac524953a5"},{"id":"diagnostics-2024:227:015ec57a390b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"IgMFA assay","test_or_feature":"IgMFA assay","target_condition":"Typhoid fever","citation":"Moore CE, Pan-Ngum W, Wijedoru LPM, et al. Evaluation of the diagnostic accuracy of a typhoid IgM flow assay for the diagnosis of typhoid fever in Cambodian children using a Bayesian latent class model assuming an imperfect gold standard. Am J Trop Med Hyg. 2014;90(1):114-120. doi:10.4269/ajtmh.13-0384","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"227","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":227,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.59,"specificity":0.98},"tp":19.0,"fp":10.0,"fn":13.0,"tn":446.0,"sample_size":488.0,"observed_prevalence":0.06557377049180328,"sensitivity":0.59375,"specificity":0.9780701754385965,"ppv_observed":0.6551724137931034,"npv_observed":0.971677559912854,"youden_j":0.5718201754385965,"lr_positive":27.075000000000053,"lr_negative":0.41535874439461884,"diagnostic_odds_ratio":65.18461538461538,"baseline_entropy_bits_observed":0.3491843735073079,"conditional_entropy_bits_observed":0.23008869073984756,"information_bits_observed":0.11909568276746035,"information_fraction_observed":0.3410681914864322,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"37b5b6f20d33"},{"id":"diagnostics-2024:228:47a03f03a8e8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"(401.5 nM/L)","test_or_feature":"(401.5 nM/L)","target_condition":"Adrenal insufficiency","citation":"Mongioì LM, Condorelli RA, Barbagallo F, Cannarella R, La Vignera S, Calogero AE. Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value. J Clin Med. 2019;8(6):806. Published 2019 Jun 5. doi:10.3390/jcm8060806","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"228","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":228,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":1.0,"specificity":0.97},"tp":4.0,"fp":3.0,"fn":0.0,"tn":100.0,"sample_size":107.0,"observed_prevalence":0.037383177570093455,"sensitivity":1.0,"specificity":0.970873786407767,"ppv_observed":0.5714285714285714,"npv_observed":1.0,"youden_j":0.970873786407767,"lr_positive":34.33333333333335,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.2301627406079554,"conditional_entropy_bits_observed":0.06445417712373608,"information_bits_observed":0.16570856348421933,"information_fraction_observed":0.7199625927572559,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2d1eb6069c65"},{"id":"diagnostics-2024:229:36a6c01e64a8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Amsel's criteria","test_or_feature":"Amsel's criteria","target_condition":"Bacterial vaginosis","citation":"Mohammadzadeh F, Dolatian M, Jorjani M, Alavi Majd H. Diagnostic value of Amsel's clinical criteria for diagnosis of bacterial vaginosis. Glob J Health Sci. 2014;7(3):8-14. Published 2014 Oct 29. doi:10.5539/gjhs.v7n3p8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"229","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":229,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.91,"specificity":0.91},"tp":42.0,"fp":7.0,"fn":4.0,"tn":67.0,"sample_size":120.0,"observed_prevalence":0.38333333333333336,"sensitivity":0.9130434782608695,"specificity":0.9054054054054054,"ppv_observed":0.8571428571428571,"npv_observed":0.9436619718309859,"youden_j":0.8184488836662749,"lr_positive":9.652173913043475,"lr_negative":0.0960415314730695,"diagnostic_odds_ratio":100.5,"baseline_entropy_bits_observed":0.9603622703154779,"conditional_entropy_bits_observed":0.426633632289131,"information_bits_observed":0.533728638026347,"information_fraction_observed":0.5557576078566869,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d57aacfd6bfa"},{"id":"diagnostics-2024:230:f0a23bab5fec","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Vertebral osteomyelitis","citation":"Modic MT, Feiglin DH, Piraino DW, et al. Vertebral osteomyelitis: assessment using MR. Radiology. 1985;157(1):157-166. doi:10.1148/radiology.157.1.3875878","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"230","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":230,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1985,"source_reported":{"sensitivity":0.96,"specificity":0.93},"tp":22.0,"fp":1.0,"fn":1.0,"tn":13.0,"sample_size":37.0,"observed_prevalence":0.6216216216216216,"sensitivity":0.9565217391304348,"specificity":0.9285714285714286,"ppv_observed":0.9565217391304348,"npv_observed":0.9285714285714286,"youden_j":0.8850931677018634,"lr_positive":13.391304347826093,"lr_negative":0.04682274247491636,"diagnostic_odds_ratio":286.0,"baseline_entropy_bits_observed":0.9568886656798212,"conditional_entropy_bits_observed":0.30085626898008144,"information_bits_observed":0.6560323966997398,"information_fraction_observed":0.68558905568566,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"06f01a57afc3"},{"id":"diagnostics-2024:231:1dbb626abc61","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lumbar X-ray","test_or_feature":"Lumbar X-ray","target_condition":"Vertebral osteomyelitis","citation":"Modic MT, Feiglin DH, Piraino DW, et al. Vertebral osteomyelitis: assessment using MR. Radiology. 1985;157(1):157-166. doi:10.1148/radiology.157.1.3875878","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"231","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":231,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1985,"source_reported":{"sensitivity":0.83,"specificity":0.57},"tp":19.0,"fp":6.0,"fn":4.0,"tn":8.0,"sample_size":37.0,"observed_prevalence":0.6216216216216216,"sensitivity":0.8260869565217391,"specificity":0.5714285714285714,"ppv_observed":0.76,"npv_observed":0.6666666666666666,"youden_j":0.3975155279503104,"lr_positive":1.9275362318840579,"lr_negative":0.30434782608695654,"diagnostic_odds_ratio":6.333333333333333,"baseline_entropy_bits_observed":0.9568886656798212,"conditional_entropy_bits_observed":0.8350150538720792,"information_bits_observed":0.12187361180774203,"information_fraction_observed":0.1273644637865545,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5e182e4f8e54"},{"id":"diagnostics-2024:232:6450e1364011","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Mirels' score","test_or_feature":"Mirels' score","target_condition":"Impending pathologic fracture","citation":"Mirels H. Metastatic disease in long bones: A proposed scoring system for diagnosing impending pathologic fractures. 1989. Clin Orthop Relat Res. 2003;(415 Suppl):S4-S13. doi:10.1097/01.blo.0000093045.56370.dd","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"232","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":232,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1989,"source_reported":{"sensitivity":0.96,"specificity":0.94},"tp":26.0,"fp":3.0,"fn":1.0,"tn":48.0,"sample_size":78.0,"observed_prevalence":0.34615384615384615,"sensitivity":0.9629629629629629,"specificity":0.9411764705882353,"ppv_observed":0.896551724137931,"npv_observed":0.9795918367346939,"youden_j":0.9041394335511983,"lr_positive":16.370370370370367,"lr_negative":0.03935185185185191,"diagnostic_odds_ratio":416.0,"baseline_entropy_bits_observed":0.9305861291319928,"conditional_entropy_bits_observed":0.26868860271663375,"information_bits_observed":0.661897526415359,"information_fraction_observed":0.711269495315545,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"39e042f1cb72"},{"id":"diagnostics-2024:233:d7799b2b0a6c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ACR criteria","test_or_feature":"ACR criteria","target_condition":"Henoch-Schonlein purpura","citation":"Mills JA, Michel BA, Bloch DA, et al. The American College of Rheumatology 1990 criteria for the classification of Henoch-Schönlein purpura. Arthritis Rheum. 1990;33(8):1114-1121. doi:10.1002/art.1780330809","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"233","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":233,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1990,"source_reported":{"sensitivity":0.87,"specificity":0.88},"tp":74.0,"fp":89.0,"fn":11.0,"tn":633.0,"sample_size":807.0,"observed_prevalence":0.10532837670384139,"sensitivity":0.8705882352941177,"specificity":0.8767313019390581,"ppv_observed":0.4539877300613497,"npv_observed":0.9829192546583851,"youden_j":0.7473195372331758,"lr_positive":7.062524785194975,"lr_negative":0.14760709971192268,"diagnostic_odds_ratio":47.84678243105209,"baseline_entropy_bits_observed":0.4856620888239488,"conditional_entropy_bits_observed":0.300275758388819,"information_bits_observed":0.1853863304351298,"information_fraction_observed":0.3817187602269937,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d380cd6e158f"},{"id":"diagnostics-2024:234:43035822ae9a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rheumatoid factor","test_or_feature":"Rheumatoid factor","target_condition":"Rheumatoid arthritis","citation":"Miller A, Nightingale AL, Sammon CJ, et al. Estimating the diagnostic accuracy of rheumatoid factor in UK primary care: a study using the Clinical Practice Research Datalink. Rheumatology (Oxford). 2015;54(10):1882-1889. doi:10.1093/rheumatology/kev131","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"234","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":234,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.58,"specificity":0.94},"tp":1013.0,"fp":3702.0,"fn":740.0,"tn":56981.0,"sample_size":62436.0,"observed_prevalence":0.02807675059260683,"sensitivity":0.5778665145464917,"specificity":0.9389944465501047,"ppv_observed":0.21484623541887593,"npv_observed":0.9871797092912458,"youden_j":0.5168609610965964,"lr_positive":9.472359184825708,"lr_negative":0.44955908632307684,"diagnostic_odds_ratio":21.07033196081008,"baseline_entropy_bits_observed":0.18465320525098314,"conditional_entropy_bits_observed":0.14817135705009837,"information_bits_observed":0.036481848200884764,"information_fraction_observed":0.1975695366419345,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4bd3e124a11f"},{"id":"diagnostics-2024:235:d315e68b2459","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Venous blood gas","test_or_feature":"Venous blood gas","target_condition":"Diabetic ketoacidosis","citation":"Menchine, M., Probst, M.A., Agy, C., Bach, D. and Arora, S. (2011), Diagnostic Accuracy of Venous Blood Gas Electrolytes for Identifying Diabetic Ketoacidosis in the Emergency Department. Academic Emergency Medicine, 18: 1105-1108. https://doi.org/10.1111/j.1553-2712.2011.01158.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"235","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":235,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.98,"specificity":1.0},"tp":45.0,"fp":0.0,"fn":1.0,"tn":296.0,"sample_size":342.0,"observed_prevalence":0.13450292397660818,"sensitivity":0.9782608695652174,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9966329966329966,"youden_j":0.9782608695652173,"lr_positive":null,"lr_negative":0.021739130434782594,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.5696593973280274,"conditional_entropy_bits_observed":0.02822977383525819,"information_bits_observed":0.5414296234927692,"information_fraction_observed":0.9504444691553072,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b114462e7c14"},{"id":"diagnostics-2024:236:83fb3fe5ac0f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Indirect immunofluorescence on human salt-split skin substrate","test_or_feature":"Indirect immunofluorescence on human salt-split skin substrate","target_condition":"Pemphigoid","citation":"Meijer JM, Diercks GFH, de Lang EWG, Pas HH, Jonkman MF. Assessment of Diagnostic Strategy for Early Recognition of Bullous and Nonbullous Variants of Pemphigoid. JAMA Dermatol. 2019;155(2):158–165. doi:10.1001/jamadermatol.2018.4390","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"236","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":236,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.77,"specificity":1.0},"tp":263.0,"fp":0.0,"fn":80.0,"tn":781.0,"sample_size":1124.0,"observed_prevalence":0.30516014234875444,"sensitivity":0.7667638483965015,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9070847851335656,"youden_j":0.7667638483965016,"lr_positive":null,"lr_negative":0.23323615160349853,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8875074507492531,"conditional_entropy_bits_observed":0.34173908799716,"information_bits_observed":0.5457683627520931,"information_fraction_observed":0.6149451052961229,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"faa72478b781"},{"id":"diagnostics-2024:237:8f5727f0e675","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Direct immunofluorescence microscopy","test_or_feature":"Direct immunofluorescence microscopy","target_condition":"Pemphigoid","citation":"Meijer JM, Diercks GFH, de Lang EWG, Pas HH, Jonkman MF. Assessment of Diagnostic Strategy for Early Recognition of Bullous and Nonbullous Variants of Pemphigoid. JAMA Dermatol. 2019;155(2):158–165. doi:10.1001/jamadermatol.2018.4390","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"237","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":237,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.88,"specificity":0.99},"tp":303.0,"fp":6.0,"fn":40.0,"tn":775.0,"sample_size":1124.0,"observed_prevalence":0.30516014234875444,"sensitivity":0.8833819241982507,"specificity":0.9923175416133163,"ppv_observed":0.9805825242718447,"npv_observed":0.950920245398773,"youden_j":0.8756994658115671,"lr_positive":114.98688046647305,"lr_negative":0.11752092542085964,"diagnostic_odds_ratio":978.4375,"baseline_entropy_bits_observed":0.8875074507492531,"conditional_entropy_bits_observed":0.24280036942759325,"information_bits_observed":0.6447070813216598,"information_fraction_observed":0.7264244156794222,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0eae6d10431f"},{"id":"diagnostics-2024:238:9451017b177f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Teleretinal screening","test_or_feature":"Teleretinal screening","target_condition":"Age-related macular degeneration","citation":"Mehraban Far P, Tai F, Ogunbameru A, et alDiagnostic accuracy of teleretinal screening for detection of diabetic retinopathy and age-related macular degeneration: a systematic review and meta-analysisBMJ Open Ophthalmology 2022;7:e000915. doi: 10.1136/bmjophth-2021-000915","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"238","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":238,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.69,"specificity":0.97},"tp":232.0,"fp":23.0,"fn":102.0,"tn":744.0,"sample_size":1101.0,"observed_prevalence":0.3033605812897366,"sensitivity":0.6946107784431138,"specificity":0.970013037809648,"ppv_observed":0.9098039215686274,"npv_observed":0.8794326241134752,"youden_j":0.6646238162527618,"lr_positive":23.16375943764645,"lr_negative":0.3148300173845856,"diagnostic_odds_ratio":73.57544757033249,"baseline_entropy_bits_observed":0.8853601374325948,"conditional_entropy_bits_observed":0.5092495821381564,"information_bits_observed":0.3761105552944384,"information_fraction_observed":0.4248108079330292,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"794694be74a3"},{"id":"diagnostics-2024:239:9b86ce971165","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"First day pulse oximetry","test_or_feature":"First day pulse oximetry","target_condition":"Congenital heart defects","citation":"Meberg A, Brügmann-Pieper S, Due R Jr, et al. First day of life pulse oximetry screening to detect congenital heart defects [published correction appears in J Pediatr. 2009 Apr;154(4):629]. J Pediatr. 2008;152(6):761-765. doi:10.1016/j.jpeds.2007.12.043","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"239","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":239,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.78,"specificity":0.99},"tp":21.0,"fp":2.0,"fn":6.0,"tn":295.0,"sample_size":324.0,"observed_prevalence":0.08333333333333333,"sensitivity":0.7777777777777778,"specificity":0.9932659932659933,"ppv_observed":0.9130434782608695,"npv_observed":0.9800664451827242,"youden_j":0.7710437710437712,"lr_positive":115.50000000000053,"lr_negative":0.223728813559322,"diagnostic_odds_ratio":516.25,"baseline_entropy_bits_observed":0.41381685030363374,"conditional_entropy_bits_observed":0.16131024462279522,"information_bits_observed":0.2525066056808385,"information_fraction_observed":0.6101892793770105,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fbe694aa2445"},{"id":"diagnostics-2024:240:59ddafdcc324","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Compartment pressure monitoring","test_or_feature":"Compartment pressure monitoring","target_condition":"Acute compartment syndrome","citation":"McQueen MM, Duckworth AD, Aitken SA, Court-Brown CM. The estimated sensitivity and specificity of compartment pressure monitoring for acute compartment syndrome. J Bone Joint Surg Am. 2013;95(8):673-677. doi:10.2106/JBJS.K.01731","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"240","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":240,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.97,"specificity":0.99},"tp":141.0,"fp":6.0,"fn":5.0,"tn":689.0,"sample_size":841.0,"observed_prevalence":0.17360285374554102,"sensitivity":0.9657534246575342,"specificity":0.9913669064748202,"ppv_observed":0.9591836734693877,"npv_observed":0.9927953890489913,"youden_j":0.9571203311323544,"lr_positive":111.86643835616479,"lr_negative":0.034544803865041676,"diagnostic_odds_ratio":3238.3,"baseline_entropy_bits_observed":0.6658805906284652,"conditional_entropy_bits_observed":0.09386095745542011,"information_bits_observed":0.572019633173045,"information_fraction_observed":0.8590423586805058,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"19505f333c5e"},{"id":"diagnostics-2024:241:786adbb2f12e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ultra rapid urease test","test_or_feature":"Ultra rapid urease test","target_condition":"H.pylori infection","citation":"McNicholl AG, Ducons J, Barrio J, et al. Accuracy of the Ultra-Rapid Urease Test for diagnosis of Helicobacter pylori infection. Gastroenterol Hepatol. 2017;40(10):651-657. doi:10.1016/j.gastrohep.2017.07.007","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"241","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":241,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.91,"specificity":0.94},"tp":42.0,"fp":2.0,"fn":4.0,"tn":32.0,"sample_size":80.0,"observed_prevalence":0.575,"sensitivity":0.9130434782608695,"specificity":0.9411764705882353,"ppv_observed":0.9545454545454546,"npv_observed":0.8888888888888888,"youden_j":0.8542199488491047,"lr_positive":15.521739130434778,"lr_negative":0.09239130434782615,"diagnostic_odds_ratio":168.0,"baseline_entropy_bits_observed":0.9837082626231857,"conditional_entropy_bits_observed":0.3731869939407048,"information_bits_observed":0.6105212686824808,"information_fraction_observed":0.6206324495582122,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3dbd58700d18"},{"id":"diagnostics-2024:242:9fe911d5d0f1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid urease test","test_or_feature":"Rapid urease test","target_condition":"H.pylori infection","citation":"McNicholl AG, Ducons J, Barrio J, et al. Accuracy of the Ultra-Rapid Urease Test for diagnosis of Helicobacter pylori infection. Gastroenterol Hepatol. 2017;40(10):651-657. doi:10.1016/j.gastrohep.2017.07.007","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"242","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":242,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.86,"specificity":0.91},"tp":38.0,"fp":3.0,"fn":6.0,"tn":30.0,"sample_size":77.0,"observed_prevalence":0.5714285714285714,"sensitivity":0.8636363636363636,"specificity":0.9090909090909091,"ppv_observed":0.926829268292683,"npv_observed":0.8333333333333334,"youden_j":0.7727272727272727,"lr_positive":9.499999999999996,"lr_negative":0.15,"diagnostic_odds_ratio":63.333333333333336,"baseline_entropy_bits_observed":0.9852281360342515,"conditional_entropy_bits_observed":0.5049909916319799,"information_bits_observed":0.4802371444022716,"information_fraction_observed":0.487437504916705,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"61f3aaea6cc2"},{"id":"diagnostics-2024:243:2347f89a1236","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Centor Score - modified/McIsaac","test_or_feature":"Centor Score - modified/McIsaac","target_condition":"Streptococcal pharyngitis, adults","citation":"McIsaac WJ, Kellner JD, Aufricht P, Vanjaka A, Low DE. Empirical Validation of Guidelines for the Management of Pharyngitis in Children and Adults. JAMA. 2004;291(13):1587–1595. doi:10.1001/jama.291.13.1587","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"243","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":243,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":1.0,"specificity":0.89},"tp":251.0,"fp":9.0,"fn":0.0,"tn":73.0,"sample_size":333.0,"observed_prevalence":0.7537537537537538,"sensitivity":1.0,"specificity":0.8902439024390244,"ppv_observed":0.9653846153846154,"npv_observed":1.0,"youden_j":0.8902439024390243,"lr_positive":9.111111111111112,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8052741736168278,"conditional_entropy_bits_observed":0.16945607907739813,"information_bits_observed":0.6358180945394297,"information_fraction_observed":0.7895672248914938,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"61129ca96ce7"},{"id":"diagnostics-2024:244:0976e4d6231c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Centor Score - rapid approach","test_or_feature":"Centor Score - rapid approach","target_condition":"Streptococcal pharyngitis, children","citation":"McIsaac WJ, Kellner JD, Aufricht P, Vanjaka A, Low DE. Empirical Validation of Guidelines for the Management of Pharyngitis in Children and Adults. JAMA. 2004;291(13):1587–1595. doi:10.1001/jama.291.13.1587","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"244","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":244,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.93,"specificity":0.98},"tp":296.0,"fp":3.0,"fn":22.0,"tn":133.0,"sample_size":454.0,"observed_prevalence":0.7004405286343612,"sensitivity":0.9308176100628931,"specificity":0.9779411764705882,"ppv_observed":0.9899665551839465,"npv_observed":0.8580645161290322,"youden_j":0.9087587865334812,"lr_positive":42.197064989517756,"lr_negative":0.07074289497328225,"diagnostic_odds_ratio":596.4848484848485,"baseline_entropy_bits_observed":0.8807517335674103,"conditional_entropy_bits_observed":0.25454326022627505,"information_bits_observed":0.6262084733411353,"information_fraction_observed":0.7109931771632522,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"342092251506"},{"id":"diagnostics-2024:245:4cecb5065966","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Centor Score - modified/McIsaac","test_or_feature":"Centor Score - modified/McIsaac","target_condition":"Streptococcal pharyngitis, adults","citation":"McIsaac WJ, Kellner JD, Aufricht P, Vanjaka A, Low DE. Empirical Validation of Guidelines for the Management of Pharyngitis in Children and Adults. JAMA. 2004;291(13):1587–1595. doi:10.1001/jama.291.13.1587","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"245","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":245,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":1.0,"specificity":0.84},"tp":270.0,"fp":29.0,"fn":0.0,"tn":155.0,"sample_size":454.0,"observed_prevalence":0.5947136563876652,"sensitivity":1.0,"specificity":0.842391304347826,"ppv_observed":0.903010033444816,"npv_observed":1.0,"youden_j":0.8423913043478262,"lr_positive":6.344827586206895,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.97395903548868,"conditional_entropy_bits_observed":0.30254370159209143,"information_bits_observed":0.6714153338965886,"information_fraction_observed":0.6893671185664484,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"25a4b485723f"},{"id":"diagnostics-2024:246:6acb894395a5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Centor Score - rapid approach","test_or_feature":"Centor Score - rapid approach","target_condition":"Streptococcal pharyngitis, children","citation":"McIsaac WJ, Kellner JD, Aufricht P, Vanjaka A, Low DE. Empirical Validation of Guidelines for the Management of Pharyngitis in Children and Adults. JAMA. 2004;291(13):1587–1595. doi:10.1001/jama.291.13.1587","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"246","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":246,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.94,"specificity":0.97},"tp":258.0,"fp":2.0,"fn":17.0,"tn":56.0,"sample_size":333.0,"observed_prevalence":0.8258258258258259,"sensitivity":0.9381818181818182,"specificity":0.9655172413793104,"ppv_observed":0.9923076923076923,"npv_observed":0.7671232876712328,"youden_j":0.9036990595611285,"lr_positive":27.207272727272763,"lr_negative":0.06402597402597397,"diagnostic_odds_ratio":424.94117647058823,"baseline_entropy_bits_observed":0.6671650186307059,"conditional_entropy_bits_observed":0.22245479984972436,"information_bits_observed":0.4447102187809815,"information_fraction_observed":0.666567050673172,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"18a3d1cb5b33"},{"id":"diagnostics-2024:247:443b648ad3cc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"RUDAS","test_or_feature":"RUDAS","target_condition":"Alzheimer's dementia","citation":"Matías-Guiu JA, Valles-Salgado M, Rognoni T, Hamre-Gil F, Moreno-Ramos T, Matías-Guiu J. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease. Dement Geriatr Cogn Disord. 2017;43(5-6):237-246. doi:10.1159/000469662","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"247","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":247,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.9,"specificity":0.69},"tp":83.0,"fp":21.0,"fn":9.0,"tn":47.0,"sample_size":160.0,"observed_prevalence":0.575,"sensitivity":0.9021739130434783,"specificity":0.6911764705882353,"ppv_observed":0.7980769230769231,"npv_observed":0.8392857142857143,"youden_j":0.5933503836317136,"lr_positive":2.921325051759834,"lr_negative":0.14153561517113783,"diagnostic_odds_ratio":20.64021164021164,"baseline_entropy_bits_observed":0.9837082626231857,"conditional_entropy_bits_observed":0.6943479162495058,"information_bits_observed":0.2893603463736799,"information_fraction_observed":0.2941526033359352,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"93c1a87f5774"},{"id":"diagnostics-2024:248:4edb5a870a7f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MoCA","test_or_feature":"MoCA","target_condition":"Alzheimer's dementia","citation":"Matías-Guiu JA, Valles-Salgado M, Rognoni T, Hamre-Gil F, Moreno-Ramos T, Matías-Guiu J. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease. Dement Geriatr Cogn Disord. 2017;43(5-6):237-246. doi:10.1159/000469661","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"248","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":248,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.99,"specificity":0.15},"tp":91.0,"fp":58.0,"fn":1.0,"tn":10.0,"sample_size":160.0,"observed_prevalence":0.575,"sensitivity":0.9891304347826086,"specificity":0.14705882352941177,"ppv_observed":0.610738255033557,"npv_observed":0.9090909090909091,"youden_j":0.13618925831202033,"lr_positive":1.1596701649175412,"lr_negative":0.07391304347826119,"diagnostic_odds_ratio":15.689655172413794,"baseline_entropy_bits_observed":0.9837082626231857,"conditional_entropy_bits_observed":0.9282397901844887,"information_bits_observed":0.055468472438697014,"information_fraction_observed":0.056387116532683315,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"480db881de77"},{"id":"diagnostics-2024:249:3d51e96a5baf","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MIS","test_or_feature":"MIS","target_condition":"Alzheimer's dementia","citation":"Matías-Guiu JA, Valles-Salgado M, Rognoni T, Hamre-Gil F, Moreno-Ramos T, Matías-Guiu J. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease. Dement Geriatr Cogn Disord. 2017;43(5-6):237-246. doi:10.1159/000469660","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"249","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":249,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.88,"specificity":0.6},"tp":81.0,"fp":27.0,"fn":11.0,"tn":41.0,"sample_size":160.0,"observed_prevalence":0.575,"sensitivity":0.8804347826086957,"specificity":0.6029411764705882,"ppv_observed":0.75,"npv_observed":0.7884615384615384,"youden_j":0.4833759590792839,"lr_positive":2.217391304347826,"lr_negative":0.19830328738069986,"diagnostic_odds_ratio":11.181818181818182,"baseline_entropy_bits_observed":0.9837082626231857,"conditional_entropy_bits_observed":0.7895470174410715,"information_bits_observed":0.1941612451821142,"information_fraction_observed":0.19737685710228564,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1ed5660d2e8c"},{"id":"diagnostics-2024:250:6d8000832c1d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MMSE","test_or_feature":"MMSE","target_condition":"Alzheimer's dementia","citation":"Matías-Guiu JA, Valles-Salgado M, Rognoni T, Hamre-Gil F, Moreno-Ramos T, Matías-Guiu J. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease. Dement Geriatr Cogn Disord. 2017;43(5-6):237-246. doi:10.1159/000469659","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"250","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":250,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.78,"specificity":0.82},"tp":72.0,"fp":12.0,"fn":20.0,"tn":56.0,"sample_size":160.0,"observed_prevalence":0.575,"sensitivity":0.782608695652174,"specificity":0.8235294117647058,"ppv_observed":0.8571428571428571,"npv_observed":0.7368421052631579,"youden_j":0.6061381074168799,"lr_positive":4.434782608695651,"lr_negative":0.2639751552795031,"diagnostic_odds_ratio":16.8,"baseline_entropy_bits_observed":0.9837082626231857,"conditional_entropy_bits_observed":0.7055785430603432,"information_bits_observed":0.2781297195628425,"information_fraction_observed":0.282735979894256,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"62a677f6b329"},{"id":"diagnostics-2024:251:fbfea0aa1220","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ACE-III","test_or_feature":"ACE-III","target_condition":"Alzheimer's dementia","citation":"Matías-Guiu JA, Valles-Salgado M, Rognoni T, Hamre-Gil F, Moreno-Ramos T, Matías-Guiu J. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease. Dement Geriatr Cogn Disord. 2017;43(5-6):237-246. doi:10.1159/000469658","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"251","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":251,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.7,"specificity":0.9},"tp":64.0,"fp":7.0,"fn":28.0,"tn":61.0,"sample_size":160.0,"observed_prevalence":0.575,"sensitivity":0.6956521739130435,"specificity":0.8970588235294118,"ppv_observed":0.9014084507042254,"npv_observed":0.6853932584269663,"youden_j":0.5927109974424551,"lr_positive":6.757763975155282,"lr_negative":0.3392729864575909,"diagnostic_odds_ratio":19.918367346938776,"baseline_entropy_bits_observed":0.9837082626231857,"conditional_entropy_bits_observed":0.70587450610931,"information_bits_observed":0.27783375651387565,"information_fraction_observed":0.28243511523731224,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f756d5e66653"},{"id":"diagnostics-2024:252:032cfaee14d2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ECG, low voltage","test_or_feature":"ECG, low voltage","target_condition":"Cardiac tamponade","citation":"Mathur AP, Saini A, Lucas BP, AlYousef T, Margeta B, Mba B. Diagnostic accuracy retrospectively of electrocardiographic findings and cancer history for tamponade in patients determined to have pericardial effusion by transthoracic echocardiogram. Am J Cardiol. 2013;111(7):1062-1066. doi:10.1016/j.amjcard.2012.11.065","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"252","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":252,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.56,"specificity":0.66},"tp":36.0,"fp":54.0,"fn":28.0,"tn":106.0,"sample_size":224.0,"observed_prevalence":0.2857142857142857,"sensitivity":0.5625,"specificity":0.6625,"ppv_observed":0.4,"npv_observed":0.7910447761194029,"youden_j":0.2250000000000001,"lr_positive":1.6666666666666665,"lr_negative":0.6603773584905661,"diagnostic_odds_ratio":2.5238095238095237,"baseline_entropy_bits_observed":0.863120568566631,"conditional_entropy_bits_observed":0.8324821384863823,"information_bits_observed":0.03063843008024869,"information_fraction_observed":0.03549727720094701,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a47cdd112ce2"},{"id":"diagnostics-2024:253:685f5c9fff8e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ECG, electrical alternans","test_or_feature":"ECG, electrical alternans","target_condition":"Cardiac tamponade","citation":"Mathur AP, Saini A, Lucas BP, AlYousef T, Margeta B, Mba B. Diagnostic accuracy retrospectively of electrocardiographic findings and cancer history for tamponade in patients determined to have pericardial effusion by transthoracic echocardiogram. Am J Cardiol. 2013;111(7):1062-1066. doi:10.1016/j.amjcard.2012.11.064","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"253","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":253,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.34,"specificity":0.93},"tp":22.0,"fp":11.0,"fn":42.0,"tn":149.0,"sample_size":224.0,"observed_prevalence":0.2857142857142857,"sensitivity":0.34375,"specificity":0.93125,"ppv_observed":0.6666666666666666,"npv_observed":0.7801047120418848,"youden_j":0.2749999999999999,"lr_positive":5.000000000000002,"lr_negative":0.7046979865771812,"diagnostic_odds_ratio":7.095238095238095,"baseline_entropy_bits_observed":0.863120568566631,"conditional_entropy_bits_observed":0.7833001222011435,"information_bits_observed":0.07982044636548746,"information_fraction_observed":0.09247890650786351,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"12ba391c849c"},{"id":"diagnostics-2024:254:3965ef65178e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Nystagmus suppression test (7-15, fast)","test_or_feature":"Nystagmus suppression test (7-15, fast)","target_condition":"Stroke","citation":"Mantokoudis G, Wyss T, Zamaro E, et al. Stroke Prediction Based on the Spontaneous Nystagmus Suppression Test in Dizzy Patients: A Diagnostic Accuracy Study. Neurology. 2021;97(1):e42-e51. doi:10.1212/WNL.0000000000012178","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"254","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":254,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.79,"specificity":0.73},"tp":15.0,"fp":9.0,"fn":4.0,"tn":24.0,"sample_size":52.0,"observed_prevalence":0.36538461538461536,"sensitivity":0.7894736842105263,"specificity":0.7272727272727273,"ppv_observed":0.625,"npv_observed":0.8571428571428571,"youden_j":0.5167464114832536,"lr_positive":2.8947368421052633,"lr_negative":0.28947368421052627,"diagnostic_odds_ratio":10.0,"baseline_entropy_bits_observed":0.9470622432515328,"conditional_entropy_bits_observed":0.759101035971237,"information_bits_observed":0.18796120728029575,"information_fraction_observed":0.19846763886919588,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"105735462bde"},{"id":"diagnostics-2024:255:9b4c59fa0526","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Nystagmus suppression test (0)","test_or_feature":"Nystagmus suppression test (0)","target_condition":"Stroke","citation":"Mantokoudis G, Wyss T, Zamaro E, et al. Stroke Prediction Based on the Spontaneous Nystagmus Suppression Test in Dizzy Patients: A Diagnostic Accuracy Study. Neurology. 2021;97(1):e42-e51. doi:10.1212/WNL.0000000000012177","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"255","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":255,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.74,"specificity":0.76},"tp":14.0,"fp":8.0,"fn":5.0,"tn":25.0,"sample_size":52.0,"observed_prevalence":0.36538461538461536,"sensitivity":0.7368421052631579,"specificity":0.7575757575757576,"ppv_observed":0.6363636363636364,"npv_observed":0.8333333333333334,"youden_j":0.4944178628389153,"lr_positive":3.039473684210526,"lr_negative":0.34736842105263166,"diagnostic_odds_ratio":8.75,"baseline_entropy_bits_observed":0.9470622432515328,"conditional_entropy_bits_observed":0.7750999875127828,"information_bits_observed":0.17196225573875001,"information_fraction_observed":0.18157439699882336,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7f77790922df"},{"id":"diagnostics-2024:256:75fdd32a59f1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Nystagmus suppression test (7-15, slow)","test_or_feature":"Nystagmus suppression test (7-15, slow)","target_condition":"Stroke","citation":"Mantokoudis G, Wyss T, Zamaro E, et al. Stroke Prediction Based on the Spontaneous Nystagmus Suppression Test in Dizzy Patients: A Diagnostic Accuracy Study. Neurology. 2021;97(1):e42-e51. doi:10.1212/WNL.0000000000012176","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"256","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":256,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.63,"specificity":0.85},"tp":12.0,"fp":5.0,"fn":7.0,"tn":28.0,"sample_size":52.0,"observed_prevalence":0.36538461538461536,"sensitivity":0.631578947368421,"specificity":0.8484848484848485,"ppv_observed":0.7058823529411765,"npv_observed":0.8,"youden_j":0.4800637958532694,"lr_positive":4.1684210526315795,"lr_negative":0.4342105263157895,"diagnostic_odds_ratio":9.6,"baseline_entropy_bits_observed":0.9470622432515328,"conditional_entropy_bits_observed":0.7716377142158224,"information_bits_observed":0.17542452903571037,"information_fraction_observed":0.18523020032287246,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"417a61c2131b"},{"id":"diagnostics-2024:257:9808a5fa1173","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transesophageal echocardiography","test_or_feature":"Transesophageal echocardiography","target_condition":"Left atrial thrombus","citation":"Manning WJ, Weintraub RM, Waksmonski CA, et al. Accuracy of transesophageal echocardiography for identifying left atrial thrombi. A prospective, intraoperative study. Ann Intern Med. 1995;123(11):817-822. doi:10.7326/0003-4819-123-11-199512010-00001","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"257","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":257,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1995,"source_reported":{"sensitivity":1.0,"specificity":0.99},"tp":14.0,"fp":2.0,"fn":0.0,"tn":215.0,"sample_size":231.0,"observed_prevalence":0.06060606060606061,"sensitivity":1.0,"specificity":0.9907834101382489,"ppv_observed":0.875,"npv_observed":1.0,"youden_j":0.9907834101382489,"lr_positive":108.50000000000047,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.32984607020714635,"conditional_entropy_bits_observed":0.03764948524326209,"information_bits_observed":0.29219658496388423,"information_fraction_observed":0.8858574085190165,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9253ec22a69e"},{"id":"diagnostics-2024:258:d4009f6683ba","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"EUS","test_or_feature":"EUS","target_condition":"Choledocholithiasis","citation":"Makmun D, Fauzi A, Shatri H. Sensitivity and Specificity of Magnetic Resonance Cholangiopancreatography versus Endoscopic Ultrasonography against Endoscopic Retrograde Cholangiopancreatography in Diagnosing Choledocholithiasis: The Indonesian Experience. Clin Endosc. 2017;50(5):486-490. doi:10.5946/ce.2016.159","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"258","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":258,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.96,"specificity":0.57},"tp":23.0,"fp":3.0,"fn":1.0,"tn":4.0,"sample_size":31.0,"observed_prevalence":0.7741935483870968,"sensitivity":0.9583333333333334,"specificity":0.5714285714285714,"ppv_observed":0.8846153846153846,"npv_observed":0.8,"youden_j":0.5297619047619047,"lr_positive":2.236111111111111,"lr_negative":0.0729166666666666,"diagnostic_odds_ratio":30.666666666666668,"baseline_entropy_bits_observed":0.7706290693639406,"conditional_entropy_bits_observed":0.549169698536466,"information_bits_observed":0.22145937082747458,"information_fraction_observed":0.28737479499736757,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5c1acb28f34e"},{"id":"diagnostics-2024:259:1529b713201d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRCP","test_or_feature":"MRCP","target_condition":"Choledocholithiasis","citation":"Makmun D, Fauzi A, Shatri H. Sensitivity and Specificity of Magnetic Resonance Cholangiopancreatography versus Endoscopic Ultrasonography against Endoscopic Retrograde Cholangiopancreatography in Diagnosing Choledocholithiasis: The Indonesian Experience. Clin Endosc. 2017;50(5):486-490. doi:10.5946/ce.2016.159","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"259","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":259,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.81,"specificity":0.4},"tp":17.0,"fp":6.0,"fn":4.0,"tn":4.0,"sample_size":31.0,"observed_prevalence":0.6774193548387096,"sensitivity":0.8095238095238095,"specificity":0.4,"ppv_observed":0.7391304347826086,"npv_observed":0.5,"youden_j":0.20952380952380967,"lr_positive":1.3492063492063493,"lr_negative":0.47619047619047616,"diagnostic_odds_ratio":2.8333333333333335,"baseline_entropy_bits_observed":0.907165767573082,"conditional_entropy_bits_observed":0.8724284414105997,"information_bits_observed":0.03473732616248226,"information_fraction_observed":0.038292148363814664,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"582c0f7b40d0"},{"id":"diagnostics-2024:260:e68c29dba85c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Calf squeeze test","test_or_feature":"Calf squeeze test","target_condition":"Achilles tendon tear","citation":"Maffulli N. The clinical diagnosis of subcutaneous tear of the Achilles tendon. A prospective study in 174 patients. Am J Sports Med. 1998;26(2):266-270. doi:10.1177/03635465980260021801","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"260","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":260,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1998,"source_reported":{"sensitivity":0.95,"specificity":1.0},"tp":108.0,"fp":0.0,"fn":6.0,"tn":26.0,"sample_size":140.0,"observed_prevalence":0.8142857142857143,"sensitivity":0.9473684210526315,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.8125,"youden_j":0.9473684210526314,"lr_positive":null,"lr_negative":0.052631578947368474,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.692419486327474,"conditional_entropy_bits_observed":0.1591342308857476,"information_bits_observed":0.5332852554417263,"information_fraction_observed":0.7701765562234821,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"eff11977e7a5"},{"id":"diagnostics-2024:261:3a2e07663d2d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Palpation of Achilles gap","test_or_feature":"Palpation of Achilles gap","target_condition":"Achilles tendon tear","citation":"Maffulli N. The clinical diagnosis of subcutaneous tear of the Achilles tendon. A prospective study in 174 patients. Am J Sports Med. 1998;26(2):266-270. doi:10.1177/03635465980260021801","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"261","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":261,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1998,"source_reported":{"sensitivity":0.87,"specificity":1.0},"tp":97.0,"fp":0.0,"fn":15.0,"tn":25.0,"sample_size":137.0,"observed_prevalence":0.8175182481751825,"sensitivity":0.8660714285714286,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.625,"youden_j":0.8660714285714286,"lr_positive":null,"lr_negative":0.1339285714285714,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.6854761996406743,"conditional_entropy_bits_observed":0.278666862167873,"information_bits_observed":0.4068093374728013,"information_fraction_observed":0.5934696750755901,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0376f6ceb99d"},{"id":"diagnostics-2024:262:e98973552951","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Osmole gap","test_or_feature":"Osmole gap","target_condition":"Toxic alcohol poisoning","citation":"Lynd LD, Richardson KJ, Purssell RA, et al. An evaluation of the osmole gap as a screening test for toxic alcohol poisoning. BMC Emerg Med. 2008;8:5. Published 2008 Apr 28. doi:10.1186/1471-227X-8-5","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"262","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":262,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.85,"specificity":0.5},"tp":17.0,"fp":56.0,"fn":3.0,"tn":56.0,"sample_size":132.0,"observed_prevalence":0.15151515151515152,"sensitivity":0.85,"specificity":0.5,"ppv_observed":0.2328767123287671,"npv_observed":0.9491525423728814,"youden_j":0.3500000000000001,"lr_positive":1.7,"lr_negative":0.30000000000000004,"diagnostic_odds_ratio":5.666666666666667,"baseline_entropy_bits_observed":0.6136190195993708,"conditional_entropy_bits_observed":0.5626335275509015,"information_bits_observed":0.05098549204846936,"information_fraction_observed":0.08308981700364758,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b0ab88f1d769"},{"id":"diagnostics-2024:263:880380903579","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hip US, less than 4 weeks","test_or_feature":"Hip US, less than 4 weeks","target_condition":"Congenital hip dysplasia","citation":"Lussier EC, Sun YT, Chen HW, Chang TY, Chang CH. Ultrasound screening for developmental dysplasia of the hip after 4 weeks increases exam accuracy and decreases follow-up visits. Pediatr Neonatol. 2019;60(3):270-277. doi:10.1016/j.pedneo.2018.07.008","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"263","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":263,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":1.0,"specificity":0.87},"tp":8.0,"fp":148.0,"fn":0.0,"tn":1012.0,"sample_size":1168.0,"observed_prevalence":0.00684931506849315,"sensitivity":1.0,"specificity":0.8724137931034482,"ppv_observed":0.05128205128205128,"npv_observed":1.0,"youden_j":0.8724137931034481,"lr_positive":7.837837837837836,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.05909292838573303,"conditional_entropy_bits_observed":0.03897572605259092,"information_bits_observed":0.020117202333142112,"information_fraction_observed":0.3404333290410949,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b99ed5698199"},{"id":"diagnostics-2024:265:5311aab54b61","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"Vaginal Candida infection","citation":"Lowe NK, Neal JL, Ryan-Wenger NA. Accuracy of the clinical diagnosis of vaginitis compared with a DNA probe laboratory standard. Obstet Gynecol. 2009;113(1):89-95. doi:10.1097/AOG.0b013e3181909f63","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"265","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":265,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.84,"specificity":0.85},"tp":124.0,"fp":59.0,"fn":24.0,"tn":328.0,"sample_size":535.0,"observed_prevalence":0.2766355140186916,"sensitivity":0.8378378378378378,"specificity":0.8475452196382429,"ppv_observed":0.6775956284153005,"npv_observed":0.9318181818181818,"youden_j":0.6853830574760806,"lr_positive":5.495648190563446,"lr_negative":0.19133157547791696,"diagnostic_odds_ratio":28.72316384180791,"baseline_entropy_bits_observed":0.8508258593427684,"conditional_entropy_bits_observed":0.5465057200634542,"information_bits_observed":0.30432013927931423,"information_fraction_observed":0.3576761753743478,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"076b1c92e56b"},{"id":"diagnostics-2024:266:261aeac59b53","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Spiral CT","test_or_feature":"Spiral CT","target_condition":"Colon cancer staging (T)","citation":"Liu D, Sun LM, Liang JH, Song L, Liu XP. Diagnostic accuracy of ≥ 16-slice spiral computed tomography for local staging of colon cancer: A systematic review and meta-analysis. World J Clin Cases. 2022;10(19):6483-6495. doi:10.12998/wjcc.v10.i19.6483","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"266","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":266,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.7,"specificity":0.79},"tp":1251.0,"fp":864.0,"fn":539.0,"tn":3198.0,"sample_size":5852.0,"observed_prevalence":0.3058783321941217,"sensitivity":0.6988826815642458,"specificity":0.7872968980797637,"ppv_observed":0.5914893617021276,"npv_observed":0.8557666577468558,"youden_j":0.4861795796440096,"lr_positive":3.285719273743017,"lr_negative":0.3824698397392225,"diagnostic_odds_ratio":8.590793135435993,"baseline_entropy_bits_observed":0.8883582699890727,"conditional_entropy_bits_observed":0.7327348159039522,"information_bits_observed":0.15562345408512057,"information_fraction_observed":0.17518095946473805,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2fe53610ce1f"},{"id":"diagnostics-2024:267:d6ce9a8d7427","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Spiral CT","test_or_feature":"Spiral CT","target_condition":"Colon cancer staging (N)","citation":"Liu D, Sun LM, Liang JH, Song L, Liu XP. Diagnostic accuracy of ≥ 16-slice spiral computed tomography for local staging of colon cancer: A systematic review and meta-analysis. World J Clin Cases. 2022;10(19):6483-6495. doi:10.12998/wjcc.v10.i19.6483","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"267","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":267,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.54,"specificity":0.74},"tp":193.0,"fp":179.0,"fn":163.0,"tn":507.0,"sample_size":1042.0,"observed_prevalence":0.3416506717850288,"sensitivity":0.5421348314606742,"specificity":0.739067055393586,"ppv_observed":0.5188172043010753,"npv_observed":0.7567164179104477,"youden_j":0.28120188685426006,"lr_positive":2.077678739564371,"lr_negative":0.6195177625601135,"diagnostic_odds_ratio":3.353703259416664,"baseline_entropy_bits_observed":0.9263895325101907,"conditional_entropy_bits_observed":0.8713309744625981,"information_bits_observed":0.05505855804759263,"information_fraction_observed":0.05943348463621264,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cb15b39a554d"},{"id":"diagnostics-2024:268:056344c3fe60","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Interferon-gamma","test_or_feature":"Interferon-gamma","target_condition":"Tuberculous pericarditis","citation":"Liu C, Cui YL, Ding CM, et al. Diagnostic accuracy of interferon-gamma in pericardial effusions for tuberculous pericarditis: a meta-analysis. J Thorac Dis. 2018;10(2):854-860. doi:10.21037/jtd.2017.12.107","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"268","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":268,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.95,"specificity":0.99},"tp":287.0,"fp":1.0,"fn":16.0,"tn":184.0,"sample_size":488.0,"observed_prevalence":0.6209016393442623,"sensitivity":0.9471947194719472,"specificity":0.9945945945945946,"ppv_observed":0.9965277777777778,"npv_observed":0.92,"youden_j":0.9417893140665419,"lr_positive":175.23102310231204,"lr_negative":0.05309226574831393,"diagnostic_odds_ratio":3300.5,"baseline_entropy_bits_observed":0.9574027326698087,"conditional_entropy_bits_observed":0.18452039036868462,"information_bits_observed":0.7728823423011241,"information_fraction_observed":0.8072698311042711,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"36c2362d1d18"},{"id":"diagnostics-2024:269:db08e50045f0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Colon cancer recurrence","citation":"Liemburg GB, Brandenbarg D, Berger MY, et al. Diagnostic accuracy of follow-up tests for detecting colorectal cancer recurrences in primary care: A systematic review and meta-analysis. Eur J Cancer Care (Engl). 2021;30(5):e13432. doi:10.1111/ecc.13432","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"269","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":269,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.58,"specificity":0.99},"tp":18.0,"fp":6.0,"fn":13.0,"tn":924.0,"sample_size":961.0,"observed_prevalence":0.03225806451612903,"sensitivity":0.5806451612903226,"specificity":0.9935483870967742,"ppv_observed":0.75,"npv_observed":0.9861259338313767,"youden_j":0.5741935483870968,"lr_positive":89.99999999999977,"lr_negative":0.42207792207792205,"diagnostic_odds_ratio":213.23076923076923,"baseline_entropy_bits_observed":0.205592508185083,"conditional_entropy_bits_observed":0.12312596469240991,"information_bits_observed":0.0824665434926731,"information_fraction_observed":0.4011164814353705,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"344916b2348b"},{"id":"diagnostics-2024:270:d94744b9be21","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CEA","test_or_feature":"CEA","target_condition":"Colon cancer recurrence","citation":"Liemburg GB, Brandenbarg D, Berger MY, et al. Diagnostic accuracy of follow-up tests for detecting colorectal cancer recurrences in primary care: A systematic review and meta-analysis. Eur J Cancer Care (Engl). 2021;30(5):e13432. doi:10.1111/ecc.13432","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"270","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":270,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.63,"specificity":0.89},"tp":377.0,"fp":231.0,"fn":225.0,"tn":1968.0,"sample_size":2801.0,"observed_prevalence":0.21492324169939309,"sensitivity":0.6262458471760798,"specificity":0.8949522510231923,"ppv_observed":0.6200657894736842,"npv_observed":0.8974008207934336,"youden_j":0.5211980981992721,"lr_positive":5.9615351425982634,"lr_negative":0.4176246860059962,"diagnostic_odds_ratio":14.274862914862915,"baseline_entropy_bits_observed":0.7507885426188066,"conditional_entropy_bits_observed":0.5815492174859113,"information_bits_observed":0.1692393251328953,"information_fraction_observed":0.2254154339417273,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2bba452541df"},{"id":"diagnostics-2024:271:b298f6032199","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pelvic MRI with diffusion-weighting","test_or_feature":"Pelvic MRI with diffusion-weighting","target_condition":"Pelvic inflammatory disease","citation":"Li W, Zhang Y, Cui Y, Zhang P, Wu X. Pelvic inflammatory disease: evaluation of diagnostic accuracy with conventional MR with added diffusion-weighted imaging. Abdom Imaging. 2013;38(1):193-200. doi:10.1007/s00261-012-9896-1","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"271","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":271,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.91,"specificity":0.97},"tp":118.0,"fp":1.0,"fn":11.0,"tn":29.0,"sample_size":159.0,"observed_prevalence":0.8113207547169812,"sensitivity":0.9147286821705426,"specificity":0.9666666666666667,"ppv_observed":0.9915966386554622,"npv_observed":0.725,"youden_j":0.8813953488372093,"lr_positive":27.441860465116285,"lr_negative":0.0882117080994387,"diagnostic_odds_ratio":311.09090909090907,"baseline_entropy_bits_observed":0.6987003526563343,"conditional_entropy_bits_observed":0.2658701958536643,"information_bits_observed":0.43283015680267006,"information_fraction_observed":0.6194789442385807,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3e4b7bca3f21"},{"id":"diagnostics-2024:272:800f90eef207","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pelvic MRI","test_or_feature":"Pelvic MRI","target_condition":"Pelvic inflammatory disease","citation":"Li W, Zhang Y, Cui Y, Zhang P, Wu X. Pelvic inflammatory disease: evaluation of diagnostic accuracy with conventional MR with added diffusion-weighted imaging. Abdom Imaging. 2013;38(1):193-200. doi:10.1007/s00261-012-9896-0","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"272","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":272,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.91,"specificity":0.93},"tp":117.0,"fp":2.0,"fn":12.0,"tn":28.0,"sample_size":159.0,"observed_prevalence":0.8113207547169812,"sensitivity":0.9069767441860465,"specificity":0.9333333333333333,"ppv_observed":0.9831932773109243,"npv_observed":0.7,"youden_j":0.8403100775193799,"lr_positive":13.6046511627907,"lr_negative":0.0996677740863788,"diagnostic_odds_ratio":136.5,"baseline_entropy_bits_observed":0.6987003526563343,"conditional_entropy_bits_observed":0.3138508025887716,"information_bits_observed":0.3848495500675627,"information_fraction_observed":0.5508077226588383,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"01e4b9548690"},{"id":"diagnostics-2024:273:6191733d915c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transcranial sonography","test_or_feature":"Transcranial sonography","target_condition":"Parkinson's disease","citation":"Li DH, He YC, Liu J, Chen SD. Diagnostic Accuracy of Transcranial Sonography of the Substantia Nigra in Parkinson's disease: A Systematic Review and Meta-analysis. Sci Rep. 2016;6:20863. Published 2016 Feb 16. doi:10.1038/srep20863","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"273","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":273,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.83,"specificity":0.87},"tp":1596.0,"fp":324.0,"fn":330.0,"tn":2145.0,"sample_size":4395.0,"observed_prevalence":0.43822525597269624,"sensitivity":0.8286604361370716,"specificity":0.8687727825030377,"ppv_observed":0.83125,"npv_observed":0.8666666666666667,"youden_j":0.6974332186401093,"lr_positive":6.31469943463713,"lr_negative":0.19722022525760846,"diagnostic_odds_ratio":32.01851851851852,"baseline_entropy_bits_observed":0.9889608227979948,"conditional_entropy_bits_observed":0.6050963943438712,"information_bits_observed":0.3838644284541236,"information_fraction_observed":0.388149277104915,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"16934c30fd21"},{"id":"diagnostics-2024:274:c6597680305e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urine vanillylmandelic acid","test_or_feature":"Urine vanillylmandelic acid","target_condition":"Pheochromocytoma","citation":"Lenders JWM, Pacak K, Walther MM, et al. Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best? JAMA. 2002;287(11):1427–1434. doi:10.1001/jama.287.11.1432","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"274","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":274,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.64,"specificity":0.95},"tp":96.0,"fp":23.0,"fn":55.0,"tn":442.0,"sample_size":616.0,"observed_prevalence":0.24512987012987014,"sensitivity":0.6357615894039735,"specificity":0.9505376344086022,"ppv_observed":0.8067226890756303,"npv_observed":0.8893360160965795,"youden_j":0.5862992238125757,"lr_positive":12.853440829254254,"lr_negative":0.3831919930478559,"diagnostic_odds_ratio":33.54308300395257,"baseline_entropy_bits_observed":0.8034675034774581,"conditional_entropy_bits_observed":0.5417808245725488,"information_bits_observed":0.26168667890490926,"information_fraction_observed":0.32569665577302476,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"967d79fe7f4c"},{"id":"diagnostics-2024:275:4e124b36296f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urine total metanephrines","test_or_feature":"Urine total metanephrines","target_condition":"Pheochromocytoma","citation":"Lenders JWM, Pacak K, Walther MM, et al. Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best? JAMA. 2002;287(11):1427–1434. doi:10.1001/jama.287.11.1431","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"275","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":275,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.77,"specificity":0.93},"tp":88.0,"fp":13.0,"fn":26.0,"tn":170.0,"sample_size":297.0,"observed_prevalence":0.3838383838383838,"sensitivity":0.7719298245614035,"specificity":0.9289617486338798,"ppv_observed":0.8712871287128713,"npv_observed":0.8673469387755102,"youden_j":0.7008915731952832,"lr_positive":10.866396761133608,"lr_negative":0.24551083591331274,"diagnostic_odds_ratio":44.260355029585796,"baseline_entropy_bits_observed":0.9607079018756469,"conditional_entropy_bits_observed":0.5610063926381079,"information_bits_observed":0.399701509237539,"information_fraction_observed":0.41604894521756103,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a6dec85e2ee3"},{"id":"diagnostics-2024:276:5c876d2dad63","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urine catecholamines","test_or_feature":"Urine catecholamines","target_condition":"Pheochromocytoma","citation":"Lenders JWM, Pacak K, Walther MM, et al. Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best? JAMA. 2002;287(11):1427–1434. doi:10.1001/jama.287.11.1430","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"276","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":276,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.86,"specificity":0.88},"tp":151.0,"fp":64.0,"fn":24.0,"tn":471.0,"sample_size":710.0,"observed_prevalence":0.24647887323943662,"sensitivity":0.8628571428571429,"specificity":0.8803738317757009,"ppv_observed":0.7023255813953488,"npv_observed":0.9515151515151515,"youden_j":0.7432309746328438,"lr_positive":7.2129464285714295,"lr_negative":0.15577797998180162,"diagnostic_odds_ratio":46.302734375,"baseline_entropy_bits_observed":0.8056494213497767,"conditional_entropy_bits_observed":0.4611626342920697,"information_bits_observed":0.34448678705770697,"information_fraction_observed":0.4275889461703546,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3a93794eb98f"},{"id":"diagnostics-2024:277:054ebf1a42c0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urine fractionated metanephrines","test_or_feature":"Urine fractionated metanephrines","target_condition":"Pheochromocytoma","citation":"Lenders JWM, Pacak K, Walther MM, et al. Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best? JAMA. 2002;287(11):1427–1434. doi:10.1001/jama.287.11.1429","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"277","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":277,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.97,"specificity":0.69},"tp":102.0,"fp":142.0,"fn":3.0,"tn":310.0,"sample_size":557.0,"observed_prevalence":0.18850987432675045,"sensitivity":0.9714285714285714,"specificity":0.6858407079646017,"ppv_observed":0.4180327868852459,"npv_observed":0.9904153354632588,"youden_j":0.6572692793931731,"lr_positive":3.0921529175050297,"lr_negative":0.04165898617511522,"diagnostic_odds_ratio":74.22535211267606,"baseline_entropy_bits_observed":0.698343803934991,"conditional_entropy_bits_observed":0.47337680514779046,"information_bits_observed":0.2249669987872005,"information_fraction_observed":0.3221436168253635,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"592c53125bfa"},{"id":"diagnostics-2024:278:d74aacf2b2ce","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Plasma catecholamines","test_or_feature":"Plasma catecholamines","target_condition":"Pheochromocytoma","citation":"Lenders JWM, Pacak K, Walther MM, et al. Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best? JAMA. 2002;287(11):1427–1434. doi:10.1001/jama.287.11.1428","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"278","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":278,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.84,"specificity":0.81},"tp":178.0,"fp":120.0,"fn":34.0,"tn":523.0,"sample_size":855.0,"observed_prevalence":0.247953216374269,"sensitivity":0.839622641509434,"specificity":0.8133748055987559,"ppv_observed":0.5973154362416108,"npv_observed":0.9389587073608617,"youden_j":0.6529974471081899,"lr_positive":4.498977987421385,"lr_negative":0.1971752227713842,"diagnostic_odds_ratio":22.817156862745097,"baseline_entropy_bits_observed":0.8080179025928295,"conditional_entropy_bits_observed":0.5549547569724198,"information_bits_observed":0.25306314562040966,"information_fraction_observed":0.31319002315216204,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"65a8a47458d4"},{"id":"diagnostics-2024:279:b11e5187f50d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Plasma free metanephrines","test_or_feature":"Plasma free metanephrines","target_condition":"Pheochromocytoma","citation":"Lenders JWM, Pacak K, Walther MM, et al. Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best? JAMA. 2002;287(11):1427–1434. doi:10.1001/jama.287.11.1427","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"279","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":279,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.99,"specificity":0.89},"tp":211.0,"fp":69.0,"fn":3.0,"tn":575.0,"sample_size":858.0,"observed_prevalence":0.2494172494172494,"sensitivity":0.985981308411215,"specificity":0.8928571428571429,"ppv_observed":0.7535714285714286,"npv_observed":0.9948096885813149,"youden_j":0.8788384512683578,"lr_positive":9.202492211838011,"lr_negative":0.01570093457943919,"diagnostic_odds_ratio":586.1111111111111,"baseline_entropy_bits_observed":0.8103531794626473,"conditional_entropy_bits_observed":0.2944590344285089,"information_bits_observed":0.5158941450341383,"information_fraction_observed":0.6366287664549333,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6efb4d781fe4"},{"id":"diagnostics-2024:280:1607e0034266","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"US","test_or_feature":"US","target_condition":"Gout","citation":"Lee YH, Song GG. Diagnostic accuracy of ultrasound in patients with gout: A meta-analysis. Seminars in Arthritis and Rheumatism. 2018;47(5):703-709. doi:10.1016/j.semarthrit.2017.09.012‌","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"280","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":280,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.65,"specificity":0.89},"tp":611.0,"fp":87.0,"fn":327.0,"tn":701.0,"sample_size":1726.0,"observed_prevalence":0.5434530706836617,"sensitivity":0.6513859275053305,"specificity":0.8895939086294417,"ppv_observed":0.8753581661891118,"npv_observed":0.6819066147859922,"youden_j":0.5409798361347722,"lr_positive":5.89990932039311,"lr_negative":0.391880013018259,"diagnostic_odds_ratio":15.055397377763718,"baseline_entropy_bits_observed":0.9945450161134581,"conditional_entropy_bits_observed":0.7568168376525151,"information_bits_observed":0.23772817846094307,"information_fraction_observed":0.23903209468582057,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"48b97f4d4ebe"},{"id":"diagnostics-2024:281:a44062062a01","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urinalysis (bacteria)","test_or_feature":"Urinalysis (bacteria)","target_condition":"UTI","citation":"Lee SP, Vasilopoulos T, Gallagher TJ. Sensitivity and specificity of urinalysis samples in critically ill patients. Anaesthesiol Intensive Ther. 2017;49(3):204-209. doi:10.5603/AIT.a2017.0039","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"281","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":281,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.44,"specificity":0.92},"tp":7.0,"fp":12.0,"fn":9.0,"tn":141.0,"sample_size":169.0,"observed_prevalence":0.09467455621301775,"sensitivity":0.4375,"specificity":0.9215686274509803,"ppv_observed":0.3684210526315789,"npv_observed":0.94,"youden_j":0.3590686274509802,"lr_positive":5.5781249999999964,"lr_negative":0.6103723404255319,"diagnostic_odds_ratio":9.13888888888889,"baseline_entropy_bits_observed":0.4518833420101387,"conditional_entropy_bits_observed":0.39737471103871275,"information_bits_observed":0.05450863097142594,"information_fraction_observed":0.12062544888012924,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ba69e3a54844","condition_context_id":"condition:uti"},{"id":"diagnostics-2024:282:2ec5196769b9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urinalysis (WBCs > 5/hpf)","test_or_feature":"Urinalysis (WBCs > 5/hpf)","target_condition":"UTI","citation":"Lee SP, Vasilopoulos T, Gallagher TJ. Sensitivity and specificity of urinalysis samples in critically ill patients. Anaesthesiol Intensive Ther. 2017;49(3):204-209. doi:10.5603/AIT.a2017.0038","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"282","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":282,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.73,"specificity":0.72},"tp":11.0,"fp":39.0,"fn":4.0,"tn":100.0,"sample_size":154.0,"observed_prevalence":0.09740259740259741,"sensitivity":0.7333333333333333,"specificity":0.7194244604316546,"ppv_observed":0.22,"npv_observed":0.9615384615384616,"youden_j":0.45275779376498804,"lr_positive":2.6136752136752133,"lr_negative":0.37066666666666676,"diagnostic_odds_ratio":7.051282051282051,"baseline_entropy_bits_observed":0.4607075274306461,"conditional_entropy_bits_observed":0.40563952504739864,"information_bits_observed":0.05506800238324744,"information_fraction_observed":0.11952920042431314,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5e34f4c3c28d","condition_context_id":"condition:uti"},{"id":"diagnostics-2024:283:773754264e67","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urinalysis (nitrites)","test_or_feature":"Urinalysis (nitrites)","target_condition":"UTI","citation":"Lee SP, Vasilopoulos T, Gallagher TJ. Sensitivity and specificity of urinalysis samples in critically ill patients. Anaesthesiol Intensive Ther. 2017;49(3):204-209. doi:10.5603/AIT.a2017.0037","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"283","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":283,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.25,"specificity":1.0},"tp":4.0,"fp":0.0,"fn":12.0,"tn":153.0,"sample_size":169.0,"observed_prevalence":0.09467455621301775,"sensitivity":0.25,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9272727272727272,"youden_j":0.25,"lr_positive":null,"lr_negative":0.75,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.4518833420101387,"conditional_entropy_bits_observed":0.36711997283982256,"information_bits_observed":0.08476336917031613,"information_fraction_observed":0.1875779903575519,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"dcbd9d10914e","condition_context_id":"condition:uti"},{"id":"diagnostics-2024:284:6141282d00e9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urinalysis (LE)","test_or_feature":"Urinalysis (LE)","target_condition":"UTI","citation":"Lee SP, Vasilopoulos T, Gallagher TJ. Sensitivity and specificity of urinalysis samples in critically ill patients. Anaesthesiol Intensive Ther. 2017;49(3):204-209. doi:10.5603/AIT.a2017.0036","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"284","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":284,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.88,"specificity":0.72},"tp":14.0,"fp":43.0,"fn":2.0,"tn":110.0,"sample_size":169.0,"observed_prevalence":0.09467455621301775,"sensitivity":0.875,"specificity":0.7189542483660131,"ppv_observed":0.24561403508771928,"npv_observed":0.9821428571428571,"youden_j":0.5939542483660132,"lr_positive":3.113372093023256,"lr_negative":0.17386363636363636,"diagnostic_odds_ratio":17.906976744186046,"baseline_entropy_bits_observed":0.4518833420101387,"conditional_entropy_bits_observed":0.356902723249306,"information_bits_observed":0.09498061876083269,"information_fraction_observed":0.2101883604257792,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0225a599815d","condition_context_id":"condition:uti"},{"id":"diagnostics-2024:285:c16b94e9f950","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Dimercaptosuccinic acid scintigraphy","test_or_feature":"Dimercaptosuccinic acid scintigraphy","target_condition":"Vesicoureteral reflux","citation":"Lee MD, Lin CC, Huang FY, Tsai TC, Huang CT, Tsai JD. Screening young children with a first febrile urinary tract infection for high-grade vesicoureteral reflux with renal ultrasound scanning and technetium-99m-labeled dimercaptosuccinic acid scanning. J Pediatr. 2009;154(6):797-802. doi:10.1016/j.jpeds.2008.12.046","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"285","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":285,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.66,"specificity":0.64},"tp":78.0,"fp":210.0,"fn":41.0,"tn":370.0,"sample_size":699.0,"observed_prevalence":0.17024320457796852,"sensitivity":0.6554621848739496,"specificity":0.6379310344827587,"ppv_observed":0.2708333333333333,"npv_observed":0.9002433090024331,"youden_j":0.29339321935670837,"lr_positive":1.810324129651861,"lr_negative":0.5400863047921871,"diagnostic_odds_ratio":3.35191637630662,"baseline_entropy_bits_observed":0.6582608255724216,"conditional_entropy_bits_observed":0.6224970957754499,"information_bits_observed":0.03576372979697173,"information_fraction_observed":0.05433063674398625,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e70a88f1ae3c"},{"id":"diagnostics-2024:286:2b3fb1f05a88","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Renal US","test_or_feature":"Renal US","target_condition":"Vesicoureteral reflux","citation":"Lee MD, Lin CC, Huang FY, Tsai TC, Huang CT, Tsai JD. Screening young children with a first febrile urinary tract infection for high-grade vesicoureteral reflux with renal ultrasound scanning and technetium-99m-labeled dimercaptosuccinic acid scanning. J Pediatr. 2009;154(6):797-802. doi:10.1016/j.jpeds.2008.12.045","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"286","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":286,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.67,"specificity":0.46},"tp":80.0,"fp":312.0,"fn":39.0,"tn":268.0,"sample_size":699.0,"observed_prevalence":0.17024320457796852,"sensitivity":0.6722689075630253,"specificity":0.46206896551724136,"ppv_observed":0.20408163265306123,"npv_observed":0.8729641693811075,"youden_j":0.13433787308026668,"lr_positive":1.2497306614953676,"lr_negative":0.7092687821397214,"diagnostic_odds_ratio":1.7619986850756082,"baseline_entropy_bits_observed":0.6582608255724216,"conditional_entropy_bits_observed":0.6506252460192927,"information_bits_observed":0.0076355795531288795,"information_fraction_observed":0.011599626252236723,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f9a5e4edabb4"},{"id":"diagnostics-2024:287:0d7b17210941","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Otomicroscopy","test_or_feature":"Otomicroscopy","target_condition":"Acute otitis media","citation":"Lee DH, Yeo SW. Clinical diagnostic accuracy of otitis media with effusion in children, and significance of myringotomy: diagnostic or therapeutic?. J Korean Med Sci. 2004;19(5):739-743. doi:10.3346/jkms.2004.19.5.741","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"287","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":287,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":1.0,"specificity":0.62},"tp":72.0,"fp":5.0,"fn":0.0,"tn":8.0,"sample_size":85.0,"observed_prevalence":0.8470588235294118,"sensitivity":1.0,"specificity":0.6153846153846154,"ppv_observed":0.935064935064935,"npv_observed":1.0,"youden_j":0.6153846153846154,"lr_positive":2.6,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.6171519192002819,"conditional_entropy_bits_observed":0.31409791829675426,"information_bits_observed":0.30305400090352763,"information_fraction_observed":0.49105251312550596,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"55775b33cd2e"},{"id":"diagnostics-2024:288:5a0caebc1dc5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Tympanometry","test_or_feature":"Tympanometry","target_condition":"Acute otitis media","citation":"Lee DH, Yeo SW. Clinical diagnostic accuracy of otitis media with effusion in children, and significance of myringotomy: diagnostic or therapeutic?. J Korean Med Sci. 2004;19(5):739-743. doi:10.3346/jkms.2004.19.5.740","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"288","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":288,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.88,"specificity":0.0},"tp":63.0,"fp":13.0,"fn":9.0,"tn":0.0,"sample_size":85.0,"observed_prevalence":0.8470588235294118,"sensitivity":0.875,"specificity":0.0,"ppv_observed":0.8289473684210527,"npv_observed":0.0,"youden_j":-0.125,"lr_positive":0.875,"lr_negative":null,"diagnostic_odds_ratio":0.0,"baseline_entropy_bits_observed":0.6171519192002819,"conditional_entropy_bits_observed":0.5902134059456889,"information_bits_observed":0.026938513254592955,"information_fraction_observed":0.04364972775179964,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d6403d828c24"},{"id":"diagnostics-2024:289:6644b9c4116b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Otoscopy","test_or_feature":"Otoscopy","target_condition":"Acute otitis media","citation":"Lee DH, Yeo SW. Clinical diagnostic accuracy of otitis media with effusion in children, and significance of myringotomy: diagnostic or therapeutic?. J Korean Med Sci. 2004;19(5):739-743. doi:10.3346/jkms.2004.19.5.739","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"289","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":289,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.97,"specificity":0.38},"tp":70.0,"fp":8.0,"fn":2.0,"tn":5.0,"sample_size":85.0,"observed_prevalence":0.8470588235294118,"sensitivity":0.9722222222222222,"specificity":0.38461538461538464,"ppv_observed":0.8974358974358975,"npv_observed":0.7142857142857143,"youden_j":0.3568376068376069,"lr_positive":1.579861111111111,"lr_negative":0.07222222222222226,"diagnostic_odds_ratio":21.875,"baseline_entropy_bits_observed":0.6171519192002819,"conditional_entropy_bits_observed":0.5088635984126368,"information_bits_observed":0.10828832078764505,"information_fraction_observed":0.17546460995854518,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0654410160e3"},{"id":"diagnostics-2024:290:d50d745008e9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Non-invasive prenatal testing","test_or_feature":"Non-invasive prenatal testing","target_condition":"Trisomy 13, trimester 2","citation":"Lee DE, Kim H, Park J, et al. Clinical Validation of Non-Invasive Prenatal Testing for Fetal Common Aneuploidies in 1,055 Korean Pregnant Women: a Single Center Experience. J Korean Med Sci. 2019;34(24):e172. Published 2019 Jun 24. doi:10.3346/jkms.2019.34.e177","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"290","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":290,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":1.0,"fp":1.0,"fn":0.0,"tn":591.0,"sample_size":593.0,"observed_prevalence":0.0016863406408094434,"sensitivity":1.0,"specificity":0.9983108108108109,"ppv_observed":0.5,"npv_observed":1.0,"youden_j":0.998310810810811,"lr_positive":592.0000000000158,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.017965204407153237,"conditional_entropy_bits_observed":0.003372681281618887,"information_bits_observed":0.01459252312553435,"information_fraction_observed":0.8122659110810907,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b8a441b7c97f"},{"id":"diagnostics-2024:291:acc71d6b93bb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Non-invasive prenatal testing","test_or_feature":"Non-invasive prenatal testing","target_condition":"Trisomy 18, trimester 2","citation":"Lee DE, Kim H, Park J, et al. Clinical Validation of Non-Invasive Prenatal Testing for Fetal Common Aneuploidies in 1,055 Korean Pregnant Women: a Single Center Experience. J Korean Med Sci. 2019;34(24):e172. Published 2019 Jun 24. doi:10.3346/jkms.2019.34.e176","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"291","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":291,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":3.0,"fp":0.0,"fn":0.0,"tn":590.0,"sample_size":593.0,"observed_prevalence":0.00505902192242833,"sensitivity":1.0,"specificity":1.0,"ppv_observed":1.0,"npv_observed":1.0,"youden_j":1.0,"lr_positive":null,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.04586491746473286,"conditional_entropy_bits_observed":0.0,"information_bits_observed":0.04586491746473286,"information_fraction_observed":1.0,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5814b3196023"},{"id":"diagnostics-2024:292:d107b19229dd","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Non-invasive prenatal testing","test_or_feature":"Non-invasive prenatal testing","target_condition":"Trisomy 21, trimester 2","citation":"Lee DE, Kim H, Park J, et al. Clinical Validation of Non-Invasive Prenatal Testing for Fetal Common Aneuploidies in 1,055 Korean Pregnant Women: a Single Center Experience. J Korean Med Sci. 2019;34(24):e172. Published 2019 Jun 24. doi:10.3346/jkms.2019.34.e175","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"292","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":292,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":18.0,"fp":1.0,"fn":0.0,"tn":574.0,"sample_size":593.0,"observed_prevalence":0.03035413153456998,"sensitivity":1.0,"specificity":0.9982608695652174,"ppv_observed":0.9473684210526315,"npv_observed":1.0,"youden_j":0.9982608695652173,"lr_positive":575.0000000000107,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.19616471296217447,"conditional_entropy_bits_observed":0.009531151314446047,"information_bits_observed":0.18663356164772843,"information_fraction_observed":0.9514125085469175,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1ce55b27d23c"},{"id":"diagnostics-2024:293:7537ebba30a0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Non-invasive prenatal testing","test_or_feature":"Non-invasive prenatal testing","target_condition":"Trisomy 13, trimester 1","citation":"Lee DE, Kim H, Park J, et al. Clinical Validation of Non-Invasive Prenatal Testing for Fetal Common Aneuploidies in 1,055 Korean Pregnant Women: a Single Center Experience. J Korean Med Sci. 2019;34(24):e172. Published 2019 Jun 24. doi:10.3346/jkms.2019.34.e174","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"293","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":293,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":8.0,"fp":0.0,"fn":0.0,"tn":454.0,"sample_size":462.0,"observed_prevalence":0.017316017316017316,"sensitivity":1.0,"specificity":1.0,"ppv_observed":1.0,"npv_observed":1.0,"youden_j":1.0,"lr_positive":null,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.1260931686236865,"conditional_entropy_bits_observed":0.0,"information_bits_observed":0.1260931686236865,"information_fraction_observed":1.0,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"27356818b864"},{"id":"diagnostics-2024:294:99c7265075f9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Non-invasive prenatal testing","test_or_feature":"Non-invasive prenatal testing","target_condition":"Trisomy 18, trimester 1","citation":"Lee DE, Kim H, Park J, et al. Clinical Validation of Non-Invasive Prenatal Testing for Fetal Common Aneuploidies in 1,055 Korean Pregnant Women: a Single Center Experience. J Korean Med Sci. 2019;34(24):e172. Published 2019 Jun 24. doi:10.3346/jkms.2019.34.e173","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"294","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":294,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.92,"specificity":1.0},"tp":36.0,"fp":0.0,"fn":3.0,"tn":423.0,"sample_size":462.0,"observed_prevalence":0.08441558441558442,"sensitivity":0.9230769230769231,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9929577464788732,"youden_j":0.9230769230769231,"lr_positive":null,"lr_negative":0.07692307692307687,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.4175498067724073,"conditional_entropy_bits_observed":0.05576201481451272,"information_bits_observed":0.36178779195789457,"information_fraction_observed":0.8664542195683335,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"99f4d7568fff"},{"id":"diagnostics-2024:295:01954f1356f3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Non-invasive prenatal testing","test_or_feature":"Non-invasive prenatal testing","target_condition":"Trisomy 21, trimester 1","citation":"Lee DE, Kim H, Park J, et al. Clinical Validation of Non-Invasive Prenatal Testing for Fetal Common Aneuploidies in 1,055 Korean Pregnant Women: a Single Center Experience. J Korean Med Sci. 2019;34(24):e172. Published 2019 Jun 24. doi:10.3346/jkms.2019.34.e172","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"295","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":295,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":39.0,"fp":0.0,"fn":0.0,"tn":423.0,"sample_size":462.0,"observed_prevalence":0.08441558441558442,"sensitivity":1.0,"specificity":1.0,"ppv_observed":1.0,"npv_observed":1.0,"youden_j":1.0,"lr_positive":null,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.4175498067724073,"conditional_entropy_bits_observed":0.0,"information_bits_observed":0.4175498067724073,"information_fraction_observed":1.0,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6cabcdd029a6"},{"id":"diagnostics-2024:296:8ee437d2414a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Spinal infection","citation":"Ledbetter LN, Salzman KL, Shah LM. Imaging Psoas Sign in Lumbar Spinal Infections: Evaluation of Diagnostic Accuracy and Comparison with Established Imaging Characteristics. AJNR Am J Neuroradiol. 2016;37(4):736-741. doi:10.3174/ajnr.A4571","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"296","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":296,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.92,"specificity":0.92},"tp":47.0,"fp":4.0,"fn":4.0,"tn":46.0,"sample_size":101.0,"observed_prevalence":0.504950495049505,"sensitivity":0.9215686274509803,"specificity":0.92,"ppv_observed":0.9215686274509803,"npv_observed":0.92,"youden_j":0.8415686274509804,"lr_positive":11.51960784313726,"lr_negative":0.08525149190110833,"diagnostic_odds_ratio":135.125,"baseline_entropy_bits_observed":0.999929285432166,"conditional_entropy_bits_observed":0.39937599922585115,"information_bits_observed":0.6005532862063148,"information_fraction_observed":0.6005957570757193,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a137fcf43782"},{"id":"diagnostics-2024:297:d0bbb9281067","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ACR criteria (5 criteria)","test_or_feature":"ACR criteria (5 criteria)","target_condition":"Wegener's granulomatosis","citation":"Leavitt RY, Fauci AS, Bloch DA, et al. The American College of Rheumatology 1990 criteria for the classification of Wegener's granulomatosis. Arthritis Rheum. 1990;33(8):1101-1107. doi:10.1002/art.1780330808","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"297","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":297,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1990,"source_reported":{"sensitivity":0.87,"specificity":0.94},"tp":74.0,"fp":46.0,"fn":11.0,"tn":676.0,"sample_size":807.0,"observed_prevalence":0.10532837670384139,"sensitivity":0.8705882352941177,"specificity":0.9362880886426593,"ppv_observed":0.6166666666666667,"npv_observed":0.9839883551673945,"youden_j":0.8068763239367769,"lr_positive":13.664450127877249,"lr_negative":0.13821789070657847,"diagnostic_odds_ratio":98.86166007905139,"baseline_entropy_bits_observed":0.4856620888239488,"conditional_entropy_bits_observed":0.2436151996581478,"information_bits_observed":0.242046889165801,"information_fraction_observed":0.4983853892156329,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"dd64b7a5eb4a"},{"id":"diagnostics-2024:298:4adddcd59de0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ACR criteria (4 criteria)","test_or_feature":"ACR criteria (4 criteria)","target_condition":"Wegener's granulomatosis","citation":"Leavitt RY, Fauci AS, Bloch DA, et al. The American College of Rheumatology 1990 criteria for the classification of Wegener's granulomatosis. Arthritis Rheum. 1990;33(8):1101-1107. doi:10.1002/art.1780330807","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"298","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":298,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1990,"source_reported":{"sensitivity":0.88,"specificity":0.92},"tp":75.0,"fp":58.0,"fn":10.0,"tn":664.0,"sample_size":807.0,"observed_prevalence":0.10532837670384139,"sensitivity":0.8823529411764706,"specificity":0.9196675900277008,"ppv_observed":0.5639097744360902,"npv_observed":0.9851632047477745,"youden_j":0.8020205312041715,"lr_positive":10.983772819472614,"lr_negative":0.12792345854004256,"diagnostic_odds_ratio":85.86206896551724,"baseline_entropy_bits_observed":0.4856620888239488,"conditional_entropy_bits_observed":0.2558790874478425,"information_bits_observed":0.2297830013761063,"information_fraction_observed":0.47313349479786554,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"dbb7dd6fd059"},{"id":"diagnostics-2024:299:8d85c70e74f7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Non-fasting 75g glucose challenge test","test_or_feature":"Non-fasting 75g glucose challenge test","target_condition":"Gestational diabetes","citation":"Lappharat S, Liabsuetrakul T. Accuracy of screening tests for gestational diabetes mellitus in Southeast Asia: A systematic review of diagnostic test accuracy studies. Medicine (Baltimore). 2020;99(46):e23161. doi:10.1097/MD.0000000000023164","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"299","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":299,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.58,"specificity":0.97},"tp":114.0,"fp":67.0,"fn":83.0,"tn":2503.0,"sample_size":2767.0,"observed_prevalence":0.07119624141669678,"sensitivity":0.5786802030456852,"specificity":0.9739299610894941,"ppv_observed":0.6298342541436464,"npv_observed":0.9679040989945862,"youden_j":0.5526101641351793,"lr_positive":22.19713614667776,"lr_negative":0.43259763410810587,"diagnostic_odds_ratio":51.311274950548466,"baseline_entropy_bits_observed":0.370372015808475,"conditional_entropy_bits_observed":0.25359508207670306,"information_bits_observed":0.11677693373177195,"information_fraction_observed":0.31529632031421906,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"639a7d63a963"},{"id":"diagnostics-2024:300:7fb912d6029a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hgb A1c","test_or_feature":"Hgb A1c","target_condition":"Gestational diabetes","citation":"Lappharat S, Liabsuetrakul T. Accuracy of screening tests for gestational diabetes mellitus in Southeast Asia: A systematic review of diagnostic test accuracy studies. Medicine (Baltimore). 2020;99(46):e23161. doi:10.1097/MD.0000000000023163","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"300","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":300,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.8,"specificity":0.68},"tp":70.0,"fp":330.0,"fn":18.0,"tn":689.0,"sample_size":1107.0,"observed_prevalence":0.07949412827461608,"sensitivity":0.7954545454545454,"specificity":0.676153091265947,"ppv_observed":0.175,"npv_observed":0.9745403111739745,"youden_j":0.47160763672049244,"lr_positive":2.456267217630854,"lr_negative":0.30251352421163746,"diagnostic_odds_ratio":8.11952861952862,"baseline_entropy_bits_observed":0.40039420687816796,"conditional_entropy_bits_observed":0.351005395847922,"information_bits_observed":0.04938881103024595,"information_fraction_observed":0.12335046357270096,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"71a043647eb1"},{"id":"diagnostics-2024:301:7158c905292d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fasting plasma glucose","test_or_feature":"Fasting plasma glucose","target_condition":"Gestational diabetes","citation":"Lappharat S, Liabsuetrakul T. Accuracy of screening tests for gestational diabetes mellitus in Southeast Asia: A systematic review of diagnostic test accuracy studies. Medicine (Baltimore). 2020;99(46):e23161. doi:10.1097/MD.0000000000023162","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"301","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":301,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.81,"specificity":0.7},"tp":191.0,"fp":355.0,"fn":44.0,"tn":810.0,"sample_size":1400.0,"observed_prevalence":0.16785714285714284,"sensitivity":0.8127659574468085,"specificity":0.6952789699570815,"ppv_observed":0.3498168498168498,"npv_observed":0.9484777517564403,"youden_j":0.5080449274038901,"lr_positive":2.667246029367695,"lr_negative":0.26929340688205944,"diagnostic_odds_ratio":9.90460947503201,"baseline_entropy_bits_observed":0.652779275040337,"conditional_entropy_bits_observed":0.5428480935562743,"information_bits_observed":0.10993118148406267,"information_fraction_observed":0.16840482792176534,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d6dd4776e36d"},{"id":"diagnostics-2024:302:653642c0a387","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"50g glucose challenge test","test_or_feature":"50g glucose challenge test","target_condition":"Gestational diabetes","citation":"Lappharat S, Liabsuetrakul T. Accuracy of screening tests for gestational diabetes mellitus in Southeast Asia: A systematic review of diagnostic test accuracy studies. Medicine (Baltimore). 2020;99(46):e23161. doi:10.1097/MD.0000000000023161","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"302","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":302,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.73,"specificity":0.75},"tp":291.0,"fp":929.0,"fn":107.0,"tn":2849.0,"sample_size":4176.0,"observed_prevalence":0.09530651340996169,"sensitivity":0.7311557788944724,"specificity":0.7541026998411858,"ppv_observed":0.23852459016393443,"npv_observed":0.9638024357239513,"youden_j":0.4852584787356582,"lr_positive":2.973419303189792,"lr_negative":0.3565087635439394,"diagnostic_odds_ratio":8.340382081023712,"baseline_entropy_bits_observed":0.4539385172711217,"conditional_entropy_bits_observed":0.3905166531724032,"information_bits_observed":0.06342186409871853,"information_fraction_observed":0.13971465668959493,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8b418d74f93b"},{"id":"diagnostics-2024:303:e8f8885af3fa","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Cuff leak test","test_or_feature":"Cuff leak test","target_condition":"Post-extubation stridor","citation":"Kuriyama A, Jackson JL, Kamei J. Performance of the cuff leak test in adults in predicting post-extubation airway complications: a systematic review and meta-analysis. Crit Care. 2020;24(1):640. Published 2020 Nov 7. doi:10.1186/s13054-020-03358-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"303","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":303,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.58,"specificity":0.82},"tp":310.0,"fp":1050.0,"fn":221.0,"tn":4948.0,"sample_size":6529.0,"observed_prevalence":0.08132945320876091,"sensitivity":0.583804143126177,"specificity":0.8249416472157386,"ppv_observed":0.22794117647058823,"npv_observed":0.9572451151093054,"youden_j":0.4087457903419156,"lr_positive":3.334911667115057,"lr_negative":0.5045155112225526,"diagnostic_odds_ratio":6.610127127774186,"baseline_entropy_bits_observed":0.40684636524612827,"conditional_entropy_bits_observed":0.3630215577679478,"information_bits_observed":0.04382480747818046,"information_fraction_observed":0.10771832126770492,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3d27f4b49556"},{"id":"diagnostics-2024:304:14c05f389c90","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Detailed history, physical examination, and lab tests","test_or_feature":"Detailed history, physical examination, and lab tests","target_condition":"Irritable bowel syndrome","citation":"Kruis W, Thieme C, Weinzierl M, Schüssler P, Holl J, Paulus W. A diagnostic score for the irritable bowel syndrome. Its value in the exclusion of organic disease. Gastroenterology. 1984;87(1):1-7.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"304","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":304,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1984,"source_reported":{"sensitivity":0.83,"specificity":0.97},"tp":90.0,"fp":11.0,"fn":18.0,"tn":360.0,"sample_size":479.0,"observed_prevalence":0.2254697286012526,"sensitivity":0.8333333333333334,"specificity":0.9703504043126685,"ppv_observed":0.8910891089108911,"npv_observed":0.9523809523809523,"youden_j":0.803683737646002,"lr_positive":28.106060606060645,"lr_negative":0.17175925925925922,"diagnostic_odds_ratio":163.63636363636363,"baseline_entropy_bits_observed":0.7700300399742332,"conditional_entropy_bits_observed":0.3226737054993137,"information_bits_observed":0.44735633447491957,"information_fraction_observed":0.5809595876154248,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"45aa02db496e"},{"id":"diagnostics-2024:305:8d8225df7dbb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PET/CT scan","test_or_feature":"PET/CT scan","target_condition":"Brain metastases in lung cancer","citation":"Krüger S, Mottaghy FM, Buck AK, et al. Brain metastasis in lung cancer. Comparison of cerebral MRI and 18F-FDG-PET/CT for diagnosis in the initial staging. Nuklearmedizin. 2011;50(3):101-106. doi:10.3413/Nukmed-0338-10-07","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"305","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":305,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.3,"specificity":0.98},"tp":6.0,"fp":2.0,"fn":14.0,"tn":80.0,"sample_size":102.0,"observed_prevalence":0.19607843137254902,"sensitivity":0.3,"specificity":0.975609756097561,"ppv_observed":0.75,"npv_observed":0.851063829787234,"youden_j":0.275609756097561,"lr_positive":12.299999999999988,"lr_negative":0.7174999999999999,"diagnostic_odds_ratio":17.142857142857142,"baseline_entropy_bits_observed":0.714015280437867,"conditional_entropy_bits_observed":0.6231800054272111,"information_bits_observed":0.09083527501065591,"information_fraction_observed":0.12721755051929917,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4bc1ddf1f536"},{"id":"diagnostics-2024:306:89aa876e0ad0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"McLean Screening Instrument","test_or_feature":"McLean Screening Instrument","target_condition":"Borderline personality disorder","citation":"Kröger C, Huget F, Roepke S. Diagnostische Effizienz des McLean Screening Instrument für Borderline-Persönlichkeitsstörung in einer Stichprobe, die eine stationäre, störungsspezifische Behandlung in Anspruch nehmen möchte [Diagnostic accuracy of the McLean Screening Instrument for borderline personality disorder in an inpatient sample who seek a disorder-specific treatment]. Psychother Psychosom Med Psychol. 2011;61(11):481-486. doi:10.1055/s-0031-1291275","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"306","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":306,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.84,"specificity":0.39},"tp":150.0,"fp":73.0,"fn":28.0,"tn":47.0,"sample_size":298.0,"observed_prevalence":0.5973154362416108,"sensitivity":0.8426966292134831,"specificity":0.39166666666666666,"ppv_observed":0.672645739910314,"npv_observed":0.6266666666666667,"youden_j":0.2343632958801498,"lr_positive":1.3852547329536706,"lr_negative":0.40162562754004316,"diagnostic_odds_ratio":3.449119373776908,"baseline_entropy_bits_observed":0.9724993184989366,"conditional_entropy_bits_observed":0.9225183531890395,"information_bits_observed":0.04998096530989704,"information_fraction_observed":0.051394344817684,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b501f81d038b"},{"id":"diagnostics-2024:307:e077d1d93a97","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CMR, Lake Louise criteria","test_or_feature":"CMR, Lake Louise criteria","target_condition":"Acute myocarditis","citation":"Kotanidis CP, Bazmpani MA, Haidich AB, Karvounis C, Antoniades C, Karamitsos TD. Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2018;11(11):1583-1590. doi:10.1016/j.jcmg.2017.12.014","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"307","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":307,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.78,"specificity":0.84},"tp":283.0,"fp":35.0,"fn":78.0,"tn":181.0,"sample_size":577.0,"observed_prevalence":0.6256499133448874,"sensitivity":0.7839335180055401,"specificity":0.8379629629629629,"ppv_observed":0.889937106918239,"npv_observed":0.6988416988416989,"youden_j":0.621896480968503,"lr_positive":4.837989711119903,"lr_negative":0.2578472934298527,"diagnostic_odds_ratio":18.763003663003662,"baseline_entropy_bits_observed":0.9539537388472538,"conditional_entropy_bits_observed":0.6718430837841081,"information_bits_observed":0.2821106550631457,"information_fraction_observed":0.29572781527545017,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c40761796691"},{"id":"diagnostics-2024:308:564168aaa998","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CMR, early gadolinium enhancement","test_or_feature":"CMR, early gadolinium enhancement","target_condition":"Acute myocarditis","citation":"Kotanidis CP, Bazmpani MA, Haidich AB, Karvounis C, Antoniades C, Karamitsos TD. Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2018;11(11):1583-1590. doi:10.1016/j.jcmg.2017.12.013","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"308","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":308,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.66,"specificity":0.7},"tp":289.0,"fp":82.0,"fn":150.0,"tn":189.0,"sample_size":710.0,"observed_prevalence":0.6183098591549295,"sensitivity":0.6583143507972665,"specificity":0.6974169741697417,"ppv_observed":0.7789757412398922,"npv_observed":0.5575221238938053,"youden_j":0.3557313249670082,"lr_positive":2.1756486471470637,"lr_negative":0.4899302165816972,"diagnostic_odds_ratio":4.440731707317073,"baseline_entropy_bits_observed":0.9592269748527185,"conditional_entropy_bits_observed":0.8710855103605558,"information_bits_observed":0.08814146449216265,"information_fraction_observed":0.09188801691663859,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"15c47a462a56"},{"id":"diagnostics-2024:309:0d466922c5e5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CMR, late gadolinium enhancement","test_or_feature":"CMR, late gadolinium enhancement","target_condition":"Acute myocarditis","citation":"Kotanidis CP, Bazmpani MA, Haidich AB, Karvounis C, Antoniades C, Karamitsos TD. Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2018;11(11):1583-1590. doi:10.1016/j.jcmg.2017.12.012","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"309","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":309,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.65,"specificity":0.92},"tp":531.0,"fp":41.0,"fn":292.0,"tn":444.0,"sample_size":1308.0,"observed_prevalence":0.6292048929663608,"sensitivity":0.6452004860267315,"specificity":0.9154639175257732,"ppv_observed":0.9283216783216783,"npv_observed":0.6032608695652174,"youden_j":0.5606644035525048,"lr_positive":7.632249651779626,"lr_negative":0.38756253215548475,"diagnostic_odds_ratio":19.692950217173404,"baseline_entropy_bits_observed":0.9512806411799437,"conditional_entropy_bits_observed":0.7080010101501844,"information_bits_observed":0.24327963102975936,"information_fraction_observed":0.2557390747781871,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3d8abe4f0d13"},{"id":"diagnostics-2024:310:211e6302f1a9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CMR, increased T2 ratio/signal","test_or_feature":"CMR, increased T2 ratio/signal","target_condition":"Acute myocarditis","citation":"Kotanidis CP, Bazmpani MA, Haidich AB, Karvounis C, Antoniades C, Karamitsos TD. Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2018;11(11):1583-1590. doi:10.1016/j.jcmg.2017.12.011","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"310","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":310,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.66,"specificity":0.81},"tp":428.0,"fp":78.0,"fn":222.0,"tn":332.0,"sample_size":1060.0,"observed_prevalence":0.6132075471698113,"sensitivity":0.6584615384615384,"specificity":0.8097560975609757,"ppv_observed":0.8458498023715415,"npv_observed":0.5992779783393501,"youden_j":0.4682176360225141,"lr_positive":3.461143984220908,"lr_negative":0.42177942539388324,"diagnostic_odds_ratio":8.206052206052206,"baseline_entropy_bits_observed":0.9626983787500768,"conditional_entropy_bits_observed":0.803703067923323,"information_bits_observed":0.15899531082675378,"information_fraction_observed":0.16515589340992343,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2c51844fc719"},{"id":"diagnostics-2024:311:f5bd334ebc78","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CMR, extracellular volume fraction","test_or_feature":"CMR, extracellular volume fraction","target_condition":"Acute myocarditis","citation":"Kotanidis CP, Bazmpani MA, Haidich AB, Karvounis C, Antoniades C, Karamitsos TD. Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2018;11(11):1583-1590. doi:10.1016/j.jcmg.2017.12.010","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"311","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":311,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.74,"specificity":0.77},"tp":165.0,"fp":35.0,"fn":58.0,"tn":114.0,"sample_size":372.0,"observed_prevalence":0.5994623655913979,"sensitivity":0.7399103139013453,"specificity":0.7651006711409396,"ppv_observed":0.825,"npv_observed":0.6627906976744186,"youden_j":0.505010985042285,"lr_positive":3.1499039077514417,"lr_negative":0.33994178270789077,"diagnostic_odds_ratio":9.266009852216749,"baseline_entropy_bits_observed":0.9712642217771441,"conditional_entropy_bits_observed":0.7860439394835823,"information_bits_observed":0.1852202822935618,"information_fraction_observed":0.1907002009758581,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fd7dcbeb8bea"},{"id":"diagnostics-2024:312:e4f7a65c95a4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CMR, T2 mapping","test_or_feature":"CMR, T2 mapping","target_condition":"Acute myocarditis","citation":"Kotanidis CP, Bazmpani MA, Haidich AB, Karvounis C, Antoniades C, Karamitsos TD. Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2018;11(11):1583-1590. doi:10.1016/j.jcmg.2017.12.009","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"312","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":312,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.72,"specificity":0.84},"tp":165.0,"fp":24.0,"fn":64.0,"tn":128.0,"sample_size":381.0,"observed_prevalence":0.6010498687664042,"sensitivity":0.7205240174672489,"specificity":0.8421052631578947,"ppv_observed":0.873015873015873,"npv_observed":0.6666666666666666,"youden_j":0.5626292806251436,"lr_positive":4.563318777292575,"lr_negative":0.3318777292576419,"diagnostic_odds_ratio":13.75,"baseline_entropy_bits_observed":0.9703331467646471,"conditional_entropy_bits_observed":0.7351557820167385,"information_bits_observed":0.23517736474790862,"information_fraction_observed":0.24236765025708285,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"df0038d3e390"},{"id":"diagnostics-2024:313:2f7c574b71f6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CMR, native T1 mapping","test_or_feature":"CMR, native T1 mapping","target_condition":"Acute myocarditis","citation":"Kotanidis CP, Bazmpani MA, Haidich AB, Karvounis C, Antoniades C, Karamitsos TD. Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2018;11(11):1583-1590. doi:10.1016/j.jcmg.2017.12.008","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"313","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":313,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.83,"specificity":0.89},"tp":286.0,"fp":26.0,"fn":58.0,"tn":213.0,"sample_size":583.0,"observed_prevalence":0.5900514579759862,"sensitivity":0.8313953488372093,"specificity":0.891213389121339,"ppv_observed":0.9166666666666666,"npv_observed":0.7859778597785978,"youden_j":0.7226087379585482,"lr_positive":7.64244186046512,"lr_negative":0.18918550060050218,"diagnostic_odds_ratio":40.39655172413793,"baseline_entropy_bits_observed":0.9764734407392262,"conditional_entropy_bits_observed":0.5696692979007378,"information_bits_observed":0.4068041428384883,"information_fraction_observed":0.4166054353004447,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b7d9ff234cad"},{"id":"diagnostics-2024:314:5015e4caf77c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hounsfield units of -44.9","test_or_feature":"Hounsfield units of -44.9","target_condition":"Bone marrow infiltration of multiple myeloma","citation":"Kosmala A, Weng AM, Heidemeier A, et al. Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis. Radiology. 2018;286(1):205-213. doi:10.1148/radiol.2017170282","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"314","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":314,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.93,"specificity":0.92},"tp":70.0,"fp":13.0,"fn":5.0,"tn":157.0,"sample_size":245.0,"observed_prevalence":0.30612244897959184,"sensitivity":0.9333333333333333,"specificity":0.9235294117647059,"ppv_observed":0.8433734939759037,"npv_observed":0.9691358024691358,"youden_j":0.8568627450980393,"lr_positive":12.205128205128213,"lr_negative":0.0721868365180467,"diagnostic_odds_ratio":169.07692307692307,"baseline_entropy_bits_observed":0.8886466698980793,"conditional_entropy_bits_observed":0.3435238681497954,"information_bits_observed":0.5451228017482839,"information_fraction_observed":0.6134303094961298,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"192bca9310f5"},{"id":"diagnostics-2024:315:ce983b7f645d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Virtual noncalcium images","test_or_feature":"Virtual noncalcium images","target_condition":"Bone marrow infiltration of multiple myeloma","citation":"Kosmala A, Weng AM, Heidemeier A, et al. Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis. Radiology. 2018;286(1):205-213. doi:10.1148/radiol.2017170281","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"315","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":315,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.91,"specificity":0.91},"tp":21.0,"fp":1.0,"fn":2.0,"tn":10.0,"sample_size":34.0,"observed_prevalence":0.6764705882352942,"sensitivity":0.9130434782608695,"specificity":0.9090909090909091,"ppv_observed":0.9545454545454546,"npv_observed":0.8333333333333334,"youden_j":0.8221343873517786,"lr_positive":10.043478260869561,"lr_negative":0.09565217391304354,"diagnostic_odds_ratio":105.0,"baseline_entropy_bits_observed":0.9081783472997051,"conditional_entropy_bits_observed":0.4020323173954947,"information_bits_observed":0.5061460299042104,"information_fraction_observed":0.5573200808069682,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"61bd317b9131"},{"id":"diagnostics-2024:316:a9f75f6eec9d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid immunochromatographic test","test_or_feature":"Rapid immunochromatographic test","target_condition":"Hypothyroidism","citation":"Kosack CS, Page A-L, Van Hulsteijn LT, Lentjes EGWM (2012) TSH-CHECK-1 Test: Diagnostic Accuracy and Potential Application to Initiating Treatment for Hypothyroidism in Patients on Anti-Tuberculosis Drugs. PLoS ONE 7(3): e33704. https://doi.org/10.1371/journal.pone.0033704","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"316","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":316,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.81,"specificity":1.0},"tp":108.0,"fp":0.0,"fn":25.0,"tn":82.0,"sample_size":215.0,"observed_prevalence":0.6186046511627907,"sensitivity":0.8120300751879699,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.7663551401869159,"youden_j":0.8120300751879699,"lr_positive":null,"lr_negative":0.18796992481203012,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9590215551692692,"conditional_entropy_bits_observed":0.39033162056684534,"information_bits_observed":0.5686899346024239,"information_fraction_observed":0.5929897316041546,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6dcfe1823a0e"},{"id":"diagnostics-2024:317:ae6150a95eb4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Technetium-99m sestamibi myocardial perfusion imaging","test_or_feature":"Technetium-99m sestamibi myocardial perfusion imaging","target_condition":"Cocaine-associated myocardial infarction","citation":"Kontos MC, Schmidt KL, Nicholson CS, Ornato JP, Jesse RL, Tatum JL. Myocardial perfusion imaging with technetium-99m sestamibi in patients with cocaine-associated chest pain. Ann Emerg Med. 1999;33(6):639-645.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"317","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":317,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":1.0,"specificity":0.93},"tp":2.0,"fp":3.0,"fn":0.0,"tn":38.0,"sample_size":43.0,"observed_prevalence":0.046511627906976744,"sensitivity":1.0,"specificity":0.926829268292683,"ppv_observed":0.4,"npv_observed":1.0,"youden_j":0.9268292682926829,"lr_positive":13.666666666666675,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.27138958750811115,"conditional_entropy_bits_observed":0.11290123191333355,"information_bits_observed":0.15848835559477759,"information_fraction_observed":0.583988343289113,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0e7d89038f1a"},{"id":"diagnostics-2024:318:f2f9a1fa9427","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"HPV test","test_or_feature":"HPV test","target_condition":"Cervical cancer","citation":"Koliopoulos G, Nyaga VN, Santesso N, et al. Cytology versus HPV testing for cervical cancer screening in the general population. Cochrane Database Syst Rev. 2017;8(8):CD008587. Published 2017 Aug 10. doi:10.1002/14651858.CD008587.pub2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"318","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":318,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.9,"specificity":0.9},"tp":2488.0,"fp":13685.0,"fn":276.0,"tn":121781.0,"sample_size":138230.0,"observed_prevalence":0.019995659408232655,"sensitivity":0.9001447178002895,"specificity":0.8989783414288456,"ppv_observed":0.1538366413157732,"npv_observed":0.997738761398363,"youden_j":0.7991230592291352,"lr_positive":8.910413178044134,"lr_negative":0.11107640484530415,"diagnostic_odds_ratio":80.21877544968838,"baseline_entropy_bits_observed":0.14141617068504211,"conditional_entropy_bits_observed":0.09289080778777686,"information_bits_observed":0.04852536289726525,"information_fraction_observed":0.34313871364357257,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7710bc1c125e"},{"id":"diagnostics-2024:319:9560d8a9946c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pap smear","test_or_feature":"Pap smear","target_condition":"Cervical cancer","citation":"Koliopoulos G, Nyaga VN, Santesso N, et al. Cytology versus HPV testing for cervical cancer screening in the general population. Cochrane Database Syst Rev. 2017;8(8):CD008587. Published 2017 Aug 10. doi:10.1002/14651858.CD008587.pub2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"319","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":319,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.75,"specificity":0.9},"tp":1230.0,"fp":7790.0,"fn":410.0,"tn":72573.0,"sample_size":82003.0,"observed_prevalence":0.019999268319451726,"sensitivity":0.75,"specificity":0.9030648432736458,"ppv_observed":0.13636363636363635,"npv_observed":0.994382253401477,"youden_j":0.6530648432736457,"lr_positive":7.737130937098841,"lr_negative":0.2768350488473675,"diagnostic_odds_ratio":27.948523748395377,"baseline_entropy_bits_observed":0.14143643434814035,"conditional_entropy_bits_observed":0.10777812275210097,"information_bits_observed":0.03365831159603938,"information_fraction_observed":0.23797483124603339,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"06dd5ae022c1"},{"id":"diagnostics-2024:320:cfda0670d414","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"iNPH Radscale","test_or_feature":"iNPH Radscale","target_condition":"Normal pressure hydrocephalus","citation":"Kockum K, Virhammar J, Riklund K, Söderström L, Larsson E-M, Laurell K. Diagnostic accuracy of the inph radscale in idiopathic normal pressure hydrocephalus. PLOS ONE. 2020;15(4). doi:10.1371/journal.pone.0232275","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"320","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":320,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":1.0,"specificity":0.96},"tp":75.0,"fp":2.0,"fn":0.0,"tn":53.0,"sample_size":130.0,"observed_prevalence":0.5769230769230769,"sensitivity":1.0,"specificity":0.9636363636363636,"ppv_observed":0.974025974025974,"npv_observed":1.0,"youden_j":0.9636363636363636,"lr_positive":27.49999999999999,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9828586897127056,"conditional_entropy_bits_observed":0.1029320142024334,"information_bits_observed":0.8799266755102723,"information_fraction_observed":0.8952728247918113,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c5e40da7a56a"},{"id":"diagnostics-2024:321:2047b10348e1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical pulmonary infection score (CPIS)","test_or_feature":"Clinical pulmonary infection score (CPIS)","target_condition":"Ventilator-associated pneumonia","citation":"Klompas M. Does this patient have ventilator-associated pneumonia?. JAMA. 2007;297(14):1583-1593. doi:10.1001/jama.297.14.1583","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"321","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":321,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2007,"source_reported":{"sensitivity":0.82,"specificity":0.75},"tp":32.0,"fp":13.0,"fn":7.0,"tn":38.0,"sample_size":90.0,"observed_prevalence":0.43333333333333335,"sensitivity":0.8205128205128205,"specificity":0.7450980392156863,"ppv_observed":0.7111111111111111,"npv_observed":0.8444444444444444,"youden_j":0.5656108597285068,"lr_positive":3.2189349112426036,"lr_negative":0.24089068825910934,"diagnostic_odds_ratio":13.362637362637363,"baseline_entropy_bits_observed":0.9871377743721863,"conditional_entropy_bits_observed":0.7454259152064117,"information_bits_observed":0.24171185916577465,"information_fraction_observed":0.24486132072040495,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"974a62cdc726"},{"id":"diagnostics-2024:322:1a6d036776e7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"New (short) PDA score, day 4","test_or_feature":"New (short) PDA score, day 4","target_condition":"Patent ductus arteriosus","citation":"Kindler A, Seipolt B, Heilmann A, Range U, Rüdiger M and Hofmann SR (2017) Development of a Diagnostic Clinical Score for Hemodynamically Significant Patent Ductus Arteriosus. Front. Pediatr. 5:280. doi: 10.3389/fped.2017.00281","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"322","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":322,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.84,"specificity":0.8},"tp":74.0,"fp":13.0,"fn":14.0,"tn":53.0,"sample_size":154.0,"observed_prevalence":0.5714285714285714,"sensitivity":0.8409090909090909,"specificity":0.803030303030303,"ppv_observed":0.8505747126436781,"npv_observed":0.7910447761194029,"youden_j":0.643939393939394,"lr_positive":4.269230769230768,"lr_negative":0.1981132075471698,"diagnostic_odds_ratio":21.54945054945055,"baseline_entropy_bits_observed":0.9852281360342515,"conditional_entropy_bits_observed":0.6654288409511533,"information_bits_observed":0.31979929508309823,"information_fraction_observed":0.3245941557966026,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"13e4cb4d8af4"},{"id":"diagnostics-2024:323:9e900e01f3ed","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Re-established PDA score, day 4","test_or_feature":"Re-established PDA score, day 4","target_condition":"Patent ductus arteriosus","citation":"Kindler A, Seipolt B, Heilmann A, Range U, Rüdiger M and Hofmann SR (2017) Development of a Diagnostic Clinical Score for Hemodynamically Significant Patent Ductus Arteriosus. Front. Pediatr. 5:280. doi: 10.3389/fped.2017.00280","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"323","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":323,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.89,"specificity":0.77},"tp":78.0,"fp":15.0,"fn":10.0,"tn":51.0,"sample_size":154.0,"observed_prevalence":0.5714285714285714,"sensitivity":0.8863636363636364,"specificity":0.7727272727272727,"ppv_observed":0.8387096774193549,"npv_observed":0.8360655737704918,"youden_j":0.6590909090909092,"lr_positive":3.8999999999999995,"lr_negative":0.14705882352941177,"diagnostic_odds_ratio":26.52,"baseline_entropy_bits_observed":0.9852281360342515,"conditional_entropy_bits_observed":0.639863906685584,"information_bits_observed":0.3453642293486675,"information_fraction_observed":0.3505423939056699,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"04db29a95d4c"},{"id":"diagnostics-2024:324:8521b2b21229","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Knee MRI","test_or_feature":"Knee MRI","target_condition":"Lateral meniscus tear","citation":"Kim SH, Lee HJ, Jang YH, Chun KJ, Park YB. Diagnostic Accuracy of Magnetic Resonance Imaging in the Detection of Type and Location of Meniscus Tears: Comparison with Arthroscopic Findings. J Clin Med. 2021;10(4):606. Published 2021 Feb 5. doi:10.3390/jcm10040607","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"324","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":324,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.81,"specificity":0.85},"tp":219.0,"fp":40.0,"fn":52.0,"tn":232.0,"sample_size":543.0,"observed_prevalence":0.4990791896869245,"sensitivity":0.8081180811808119,"specificity":0.8529411764705882,"ppv_observed":0.8455598455598455,"npv_observed":0.8169014084507042,"youden_j":0.6610592576514001,"lr_positive":5.495202952029519,"lr_negative":0.22496500827077232,"diagnostic_odds_ratio":24.426923076923078,"baseline_entropy_bits_observed":0.9999975535005097,"conditional_entropy_bits_observed":0.6553436139761735,"information_bits_observed":0.3446539395243362,"information_fraction_observed":0.3446547827220865,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3736bf63dd7f"},{"id":"diagnostics-2024:325:ece30a0ec1e8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Knee MRI","test_or_feature":"Knee MRI","target_condition":"Medial meniscus tear","citation":"Kim SH, Lee HJ, Jang YH, Chun KJ, Park YB. Diagnostic Accuracy of Magnetic Resonance Imaging in the Detection of Type and Location of Meniscus Tears: Comparison with Arthroscopic Findings. J Clin Med. 2021;10(4):606. Published 2021 Feb 5. doi:10.3390/jcm10040606","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"325","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":325,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.92,"specificity":0.8},"tp":240.0,"fp":57.0,"fn":21.0,"tn":225.0,"sample_size":543.0,"observed_prevalence":0.48066298342541436,"sensitivity":0.9195402298850575,"specificity":0.7978723404255319,"ppv_observed":0.8080808080808081,"npv_observed":0.9146341463414634,"youden_j":0.7174125703105894,"lr_positive":4.549304295220811,"lr_negative":0.10084291187739465,"diagnostic_odds_ratio":45.11278195488722,"baseline_entropy_bits_observed":0.9989208252238834,"conditional_entropy_bits_observed":0.576507255130126,"information_bits_observed":0.42241357009375735,"information_fraction_observed":0.4228699206456966,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4e3444895fe9"},{"id":"diagnostics-2024:326:29a0e1ffabb5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Magnetic resonance elastography","test_or_feature":"Magnetic resonance elastography","target_condition":"Hepatic fibrosis in AATD liver disease","citation":"Kim RG, Nguyen P, Bettencourt R, et al. Magnetic resonance elastography identifies fibrosis in adults with alpha-1 antitrypsin deficiency liver disease: a prospective study. Aliment Pharmacol Ther. 2016;44(3):287-299. doi:10.1111/apt.13691","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"326","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":326,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.8,"specificity":1.0},"tp":4.0,"fp":0.0,"fn":1.0,"tn":4.0,"sample_size":9.0,"observed_prevalence":0.5555555555555556,"sensitivity":0.8,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.8,"youden_j":0.8,"lr_positive":null,"lr_negative":0.19999999999999996,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9910760598382222,"conditional_entropy_bits_observed":0.4010711638263124,"information_bits_observed":0.5900048960119098,"information_fraction_observed":0.5953174735228888,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"757eef222db6"},{"id":"diagnostics-2024:327:f0eb0e05731e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lumbar MRI","test_or_feature":"Lumbar MRI","target_condition":"Herniated disc","citation":"Kim JH, van Rijn RM, van Tulder MW, et al. Diagnostic accuracy of diagnostic imaging for lumbar disc herniation in adults with low back pain or sciatica is unknown; a systematic review. Chiropr Man Therap. 2018;26:37. Published 2018 Aug 21. doi:10.1186/s12998-018-0207-x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"327","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":327,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.79,"specificity":0.78},"tp":207.0,"fp":30.0,"fn":55.0,"tn":106.0,"sample_size":398.0,"observed_prevalence":0.6582914572864321,"sensitivity":0.7900763358778626,"specificity":0.7794117647058824,"ppv_observed":0.8734177215189873,"npv_observed":0.6583850931677019,"youden_j":0.5694881005837451,"lr_positive":3.5816793893129772,"lr_negative":0.2693360218925536,"diagnostic_odds_ratio":13.298181818181819,"baseline_entropy_bits_observed":0.9264442868430003,"conditional_entropy_bits_observed":0.7010474795657524,"information_bits_observed":0.22539680727724787,"information_fraction_observed":0.24329234955436094,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8d8527dc6af4"},{"id":"diagnostics-2024:328:7c800a788fb0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lumbar CT","test_or_feature":"Lumbar CT","target_condition":"Herniated disc","citation":"Kim JH, van Rijn RM, van Tulder MW, et al. Diagnostic accuracy of diagnostic imaging for lumbar disc herniation in adults with low back pain or sciatica is unknown; a systematic review. Chiropr Man Therap. 2018;26:37. Published 2018 Aug 21. doi:10.1186/s12998-018-0207-x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"328","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":328,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.77,"specificity":0.8},"tp":483.0,"fp":54.0,"fn":145.0,"tn":221.0,"sample_size":903.0,"observed_prevalence":0.6954595791805094,"sensitivity":0.7691082802547771,"specificity":0.8036363636363636,"ppv_observed":0.8994413407821229,"npv_observed":0.6038251366120219,"youden_j":0.5727446438911405,"lr_positive":3.9167551309271045,"lr_negative":0.28730870104043577,"diagnostic_odds_ratio":13.63256704980843,"baseline_entropy_bits_observed":0.8867704636190114,"conditional_entropy_bits_observed":0.6725726769855465,"information_bits_observed":0.2141977866334649,"information_fraction_observed":0.24154817443885004,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7063ac6d5fab"},{"id":"diagnostics-2024:329:e810ff3bd9e5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lumbar myelography","test_or_feature":"Lumbar myelography","target_condition":"Herniated disc","citation":"Kim JH, van Rijn RM, van Tulder MW, et al. Diagnostic accuracy of diagnostic imaging for lumbar disc herniation in adults with low back pain or sciatica is unknown; a systematic review. Chiropr Man Therap. 2018;26:37. Published 2018 Aug 21. doi:10.1186/s12998-018-0207-x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"329","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":329,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.77,"specificity":0.77},"tp":475.0,"fp":66.0,"fn":141.0,"tn":218.0,"sample_size":900.0,"observed_prevalence":0.6844444444444444,"sensitivity":0.7711038961038961,"specificity":0.7676056338028169,"ppv_observed":0.878003696857671,"npv_observed":0.6072423398328691,"youden_j":0.5387095299067131,"lr_positive":3.3180834317197947,"lr_negative":0.2981949243417134,"diagnostic_odds_ratio":11.127229744251022,"baseline_entropy_bits_observed":0.8994826456532716,"conditional_entropy_bits_observed":0.707186273107586,"information_bits_observed":0.19229637254568566,"information_fraction_observed":0.21378552824221042,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0d0b4fef7221"},{"id":"diagnostics-2024:330:3662eb58488a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hepatic vein arrival time on contrast-enhanced US","test_or_feature":"Hepatic vein arrival time on contrast-enhanced US","target_condition":"Cirrhosis","citation":"Kim G, Shim KY, Baik SK. Diagnostic Accuracy of Hepatic Vein Arrival Time Performed with Contrast-Enhanced Ultrasonography for Cirrhosis: A Systematic Review and Meta-Analysis. Gut Liver. 2017;11(1):93-101. doi:10.5009/gnl16031","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"330","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":330,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.83,"specificity":0.75},"tp":134.0,"fp":81.0,"fn":27.0,"tn":237.0,"sample_size":479.0,"observed_prevalence":0.33611691022964507,"sensitivity":0.8322981366459627,"specificity":0.7452830188679245,"ppv_observed":0.6232558139534884,"npv_observed":0.8977272727272727,"youden_j":0.5775811555138872,"lr_positive":3.2675408327582236,"lr_negative":0.22501769006997405,"diagnostic_odds_ratio":14.521262002743484,"baseline_entropy_bits_observed":0.9210542942604425,"conditional_entropy_bits_observed":0.6914062544260303,"information_bits_observed":0.22964803983441218,"information_fraction_observed":0.24933170744164143,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f3ac2f0951dc"},{"id":"diagnostics-2024:331:67ced5567d66","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rinne test (256 Hz)","test_or_feature":"Rinne test (256 Hz)","target_condition":"Conductive hearing loss","citation":"Kelly EA, Li B, Adams ME. Diagnostic Accuracy of Tuning Fork Tests for Hearing Loss: A Systematic Review. Otolaryngology–Head and Neck Surgery. 2018;159(2):220-230. doi:10.1177/0194599818770405","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"331","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":331,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.77,"specificity":0.96},"tp":420.0,"fp":55.0,"fn":128.0,"tn":1392.0,"sample_size":1995.0,"observed_prevalence":0.2746867167919799,"sensitivity":0.7664233576642335,"specificity":0.9619903248099516,"ppv_observed":0.8842105263157894,"npv_observed":0.9157894736842105,"youden_j":0.7284136824741851,"lr_positive":20.16390179163901,"lr_negative":0.24280560449702163,"diagnostic_odds_ratio":83.04545454545455,"baseline_entropy_bits_observed":0.8481096810777411,"conditional_entropy_bits_observed":0.44072307559232105,"information_bits_observed":0.40738660548542005,"information_fraction_observed":0.480346604424714,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b1301d36f081"},{"id":"diagnostics-2024:332:9d2a5a35db88","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rinne test (512 Hz)","test_or_feature":"Rinne test (512 Hz)","target_condition":"Conductive hearing loss","citation":"Kelly EA, Li B, Adams ME. Diagnostic Accuracy of Tuning Fork Tests for Hearing Loss: A Systematic Review. Otolaryngology–Head and Neck Surgery. 2018;159(2):220-230. doi:10.1177/0194599818770405","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"332","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":332,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.59,"specificity":0.97},"tp":374.0,"fp":63.0,"fn":261.0,"tn":2011.0,"sample_size":2709.0,"observed_prevalence":0.23440383905500184,"sensitivity":0.5889763779527559,"specificity":0.9696239151398264,"ppv_observed":0.8558352402745996,"npv_observed":0.8851232394366197,"youden_j":0.5586002930925824,"lr_positive":19.389476315460538,"lr_negative":0.42390004581103147,"diagnostic_odds_ratio":45.74067992458797,"baseline_entropy_bits_observed":0.7856095408035535,"conditional_entropy_bits_observed":0.5274530534378463,"information_bits_observed":0.2581564873657072,"information_fraction_observed":0.3286066092090152,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b061a2395168"},{"id":"diagnostics-2024:333:d8773a4b3828","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fasting plasma glucose","test_or_feature":"Fasting plasma glucose","target_condition":"Diabetes","citation":"Kaur G, Lakshmi PVM, Rastogi A, et al. Diagnostic accuracy of tests for type 2 diabetes and prediabetes: A systematic review and meta-analysis. PLoS One. 2020;15(11):e0242415. Published 2020 Nov 20. doi:10.1371/journal.pone.0242416","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"333","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":333,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.52,"specificity":0.98},"tp":1787.0,"fp":684.0,"fn":1651.0,"tn":41795.0,"sample_size":45917.0,"observed_prevalence":0.07487422958816996,"sensitivity":0.5197789412449099,"specificity":0.9838979260340404,"ppv_observed":0.7231889923108054,"npv_observed":0.961998803111909,"youden_j":0.5036768672789502,"lr_positive":32.28024801921424,"lr_negative":0.4880801616187935,"diagnostic_odds_ratio":66.13718515448727,"baseline_entropy_bits_observed":0.38385552585871185,"conditional_entropy_bits_observed":0.2663097773065529,"information_bits_observed":0.11754574855215894,"information_fraction_observed":0.30622393227035305,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"15d46759820a"},{"id":"diagnostics-2024:334:7d2dff370a3e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hgb A1c","test_or_feature":"Hgb A1c","target_condition":"Diabetes","citation":"Kaur G, Lakshmi PVM, Rastogi A, et al. Diagnostic accuracy of tests for type 2 diabetes and prediabetes: A systematic review and meta-analysis. PLoS One. 2020;15(11):e0242415. Published 2020 Nov 20. doi:10.1371/journal.pone.0242415","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"334","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":334,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.47,"specificity":0.97},"tp":2413.0,"fp":2052.0,"fn":2719.0,"tn":57744.0,"sample_size":64928.0,"observed_prevalence":0.07904139970428782,"sensitivity":0.4701870615744349,"specificity":0.9656833232992174,"ppv_observed":0.5404255319148936,"npv_observed":0.955030349139143,"youden_j":0.43587038487365226,"lr_positive":13.701415952195381,"lr_negative":0.5486404555641294,"diagnostic_odds_ratio":24.973397082260636,"baseline_entropy_bits_observed":0.39879246341974717,"conditional_entropy_bits_observed":0.31487682363755787,"information_bits_observed":0.0839156397821893,"information_fraction_observed":0.21042433716673398,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"48b01b35cc27"},{"id":"diagnostics-2024:335:7d61bab109fa","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Chest ultrasound","test_or_feature":"Chest ultrasound","target_condition":"Pleural effusion","citation":"Kataoka H, Takada S. The role of thoracic ultrasonography for evaluation of patients with decompensated chronic heart failure. J Am Coll Cardiol. 2000;35(6):1638-1646. doi:10.1016/s0735-1097(00)00602-2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"335","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":335,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.9,"specificity":0.95},"tp":54.0,"fp":1.0,"fn":6.0,"tn":21.0,"sample_size":82.0,"observed_prevalence":0.7317073170731707,"sensitivity":0.9,"specificity":0.9545454545454546,"ppv_observed":0.9818181818181818,"npv_observed":0.7777777777777778,"youden_j":0.8545454545454545,"lr_positive":19.80000000000002,"lr_negative":0.10476190476190474,"diagnostic_odds_ratio":189.0,"baseline_entropy_bits_observed":0.8390040613676977,"conditional_entropy_bits_observed":0.3395656195458747,"information_bits_observed":0.49943844182182295,"information_fraction_observed":0.5952753566027633,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e3b84bfc0a17"},{"id":"diagnostics-2024:336:7e6de8bfa718","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Chest X-ray","test_or_feature":"Chest X-ray","target_condition":"Pleural effusion","citation":"Kataoka H, Takada S. The role of thoracic ultrasonography for evaluation of patients with decompensated chronic heart failure. J Am Coll Cardiol. 2000;35(6):1638-1646. doi:10.1016/s0735-1097(00)00602-1","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"336","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":336,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.43,"specificity":1.0},"tp":26.0,"fp":0.0,"fn":34.0,"tn":22.0,"sample_size":82.0,"observed_prevalence":0.7317073170731707,"sensitivity":0.43333333333333335,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.39285714285714285,"youden_j":0.43333333333333335,"lr_positive":null,"lr_negative":0.5666666666666667,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8390040613676977,"conditional_entropy_bits_observed":0.6601297978377287,"information_bits_observed":0.17887426352996894,"information_fraction_observed":0.2131983285496593,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"079a31265c70"},{"id":"diagnostics-2024:337:a69859d7cf60","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Speculum examination","test_or_feature":"Speculum examination","target_condition":"Preterm rupture of membranes","citation":"Kalafat E, Yuce T, Tanju O, Koc A. Preterm premature rupture of membrane assessment via transperineal ultrasonography: a diagnostic accuracy study. J Matern Fetal Neonatal Med. 2016;29(22):3690-3694. doi:10.3109/14767058.2016.1140742","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"337","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":337,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.98,"specificity":0.98},"tp":43.0,"fp":1.0,"fn":1.0,"tn":58.0,"sample_size":103.0,"observed_prevalence":0.42718446601941745,"sensitivity":0.9772727272727273,"specificity":0.9830508474576272,"ppv_observed":0.9772727272727273,"npv_observed":0.9830508474576272,"youden_j":0.9603235747303545,"lr_positive":57.65909090909106,"lr_negative":0.02311912225705327,"diagnostic_odds_ratio":2494.0,"baseline_entropy_bits_observed":0.9846468268687552,"conditional_entropy_bits_observed":0.1378509608038865,"information_bits_observed":0.8467958660648687,"information_fraction_observed":0.85999958864209,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e3ff19f7128b"},{"id":"diagnostics-2024:338:14db32921469","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transperineal ultrasonography","test_or_feature":"Transperineal ultrasonography","target_condition":"Preterm rupture of membranes","citation":"Kalafat E, Yuce T, Tanju O, Koc A. Preterm premature rupture of membrane assessment via transperineal ultrasonography: a diagnostic accuracy study. J Matern Fetal Neonatal Med. 2016;29(22):3690-3694. doi:10.3109/14767058.2016.1140742","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"338","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":338,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.95,"specificity":0.97},"tp":42.0,"fp":2.0,"fn":2.0,"tn":57.0,"sample_size":103.0,"observed_prevalence":0.42718446601941745,"sensitivity":0.9545454545454546,"specificity":0.9661016949152542,"ppv_observed":0.9545454545454546,"npv_observed":0.9661016949152542,"youden_j":0.9206471494607089,"lr_positive":28.159090909090892,"lr_negative":0.04704944178628385,"diagnostic_odds_ratio":598.5,"baseline_entropy_bits_observed":0.9846468268687552,"conditional_entropy_bits_observed":0.23629969483778157,"information_bits_observed":0.7483471320309736,"information_fraction_observed":0.7600157859755351,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b976449f1916"},{"id":"diagnostics-2024:339:c760a764fdb9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fecal calprotectin","test_or_feature":"Fecal calprotectin","target_condition":"Crohn's disease","citation":"Jung ES, Lee SP, Kae SH, Kim JH, Kim HS, Jang HJ. Diagnostic Accuracy of Fecal Calprotectin for the Detection of Small Bowel Crohn's Disease through Capsule Endoscopy: An Updated Meta-Analysis and Systematic Review. Gut Liver. 2021;15(5):732-741. doi:10.5009/gnl20249","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"339","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":339,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.74,"specificity":0.7},"tp":279.0,"fp":175.0,"fn":99.0,"tn":408.0,"sample_size":961.0,"observed_prevalence":0.39334027055150883,"sensitivity":0.7380952380952381,"specificity":0.6998284734133791,"ppv_observed":0.6145374449339207,"npv_observed":0.8047337278106509,"youden_j":0.4379237115086172,"lr_positive":2.4589115646258506,"lr_negative":0.3742413632119514,"diagnostic_odds_ratio":6.5703896103896104,"baseline_entropy_bits_observed":0.9669213460271793,"conditional_entropy_bits_observed":0.8302052443366459,"information_bits_observed":0.1367161016905334,"information_fraction_observed":0.1413931983736456,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e6fa76e5e97a"},{"id":"diagnostics-2024:340:b14948ae3764","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Multiplex respiratory pathogen panel","test_or_feature":"Multiplex respiratory pathogen panel","target_condition":"RSV","citation":"Jullien, S., Fitzgerald, F., Keddie, S. et al. Diagnostic accuracy of multiplex respiratory pathogen panels for influenza or respiratory syncytial virus infections: systematic review and meta-analysis. BMC Infect Dis 22, 785 (2022). https://doi.org/10.1186/s12879-022-07766-9","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"340","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":340,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":1.0,"specificity":0.99},"tp":470.0,"fp":57.0,"fn":2.0,"tn":5599.0,"sample_size":6128.0,"observed_prevalence":0.07702349869451697,"sensitivity":0.9957627118644068,"specificity":0.989922206506365,"ppv_observed":0.8918406072106262,"npv_observed":0.9996429209069809,"youden_j":0.9856849183707719,"lr_positive":98.80761225096694,"lr_negative":0.004280425378623895,"diagnostic_odds_ratio":23083.59649122807,"baseline_entropy_bits_observed":0.39160346950642755,"conditional_entropy_bits_observed":0.04672070651272512,"information_bits_observed":0.3448827629937024,"information_fraction_observed":0.880693839174583,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6d67b1f0611c"},{"id":"diagnostics-2024:341:0cf904b3fae6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Cardiac MRI","test_or_feature":"Cardiac MRI","target_condition":"Pulmonary hypertension","citation":"Johns CS et al. Diagnosis of Pulmonary Hypertension with Cardiac MRI: Derivation and Validation of Regression Models. Radiology. 2019; 290:1, 61-68. doi: Radiology 2019 290:1, 61-68. doi: https://doi.org/10.1148/radiol.2018180603","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"341","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":341,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.93,"specificity":0.79},"tp":471.0,"fp":20.0,"fn":35.0,"tn":77.0,"sample_size":603.0,"observed_prevalence":0.8391376451077943,"sensitivity":0.9308300395256917,"specificity":0.7938144329896907,"ppv_observed":0.9592668024439919,"npv_observed":0.6875,"youden_j":0.7246444725153824,"lr_positive":4.514525691699603,"lr_negative":0.0871361839741287,"diagnostic_odds_ratio":51.81,"baseline_entropy_bits_observed":0.6363685957351226,"conditional_entropy_bits_observed":0.3664467724826145,"information_bits_observed":0.26992182325250813,"information_fraction_observed":0.42415955950921624,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f74bf4773cc0"},{"id":"diagnostics-2024:342:d534b7a9f75d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Carotid bruits","test_or_feature":"Carotid bruits","target_condition":"Carotid artery stenosis (100%)","citation":"Johansson EP, Wester P. Carotid bruits as predictor for carotid stenoses detected by ultrasonography: an observational study. BMC Neurol. 2008;8:23. Published 2008 Jun 24. doi:10.1186/1471-2377-8-24","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"342","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":342,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.26,"specificity":0.49},"tp":15.0,"fp":269.0,"fn":42.0,"tn":256.0,"sample_size":582.0,"observed_prevalence":0.0979381443298969,"sensitivity":0.2631578947368421,"specificity":0.4876190476190476,"ppv_observed":0.0528169014084507,"npv_observed":0.8590604026845637,"youden_j":-0.24922305764411035,"lr_positive":0.5135981216982978,"lr_negative":1.5111019736842106,"diagnostic_odds_ratio":0.3398831651619756,"baseline_entropy_bits_observed":0.4624253817433871,"conditional_entropy_bits_observed":0.44593871961939224,"information_bits_observed":0.016486662123994855,"information_fraction_observed":0.035652589098458635,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3d5d1385bdbe"},{"id":"diagnostics-2024:343:0ced8a32a6de","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Carotid bruits","test_or_feature":"Carotid bruits","target_condition":"Carotid artery stenosis (50-99%)","citation":"Johansson EP, Wester P. Carotid bruits as predictor for carotid stenoses detected by ultrasonography: an observational study. BMC Neurol. 2008;8:23. Published 2008 Jun 24. doi:10.1186/1471-2377-8-23","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"343","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":343,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.71,"specificity":0.81},"tp":236.0,"fp":48.0,"fn":98.0,"tn":200.0,"sample_size":582.0,"observed_prevalence":0.5738831615120275,"sensitivity":0.7065868263473054,"specificity":0.8064516129032258,"ppv_observed":0.8309859154929577,"npv_observed":0.6711409395973155,"youden_j":0.5130384392505312,"lr_positive":3.65069860279441,"lr_negative":0.36383233532934134,"diagnostic_odds_ratio":10.034013605442176,"baseline_entropy_bits_observed":0.9841916338665683,"conditional_entropy_bits_observed":0.7877072829464062,"information_bits_observed":0.19648435092016203,"information_fraction_observed":0.19964033848595017,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d23326342a74"},{"id":"diagnostics-2024:344:4f601b60cd6c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"SARS-CoV-2 Roche/SD Biosensor rapid antigen test","test_or_feature":"SARS-CoV-2 Roche/SD Biosensor rapid antigen test","target_condition":"COVID-19","citation":"Jegerlehner S, Suter-Riniker F, Jent P, Bittel P, Nagler M. Diagnostic accuracy of a SARS-CoV-2 rapid antigen test in real-life clinical settings. Int J Infect Dis. 2021;109:118-122. doi:10.1016/j.ijid.2021.07.010","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"344","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":344,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.65,"specificity":1.0},"tp":92.0,"fp":2.0,"fn":49.0,"tn":1319.0,"sample_size":1462.0,"observed_prevalence":0.09644322845417237,"sensitivity":0.6524822695035462,"specificity":0.9984859954579863,"ppv_observed":0.9787234042553191,"npv_observed":0.9641812865497076,"youden_j":0.6509682649615325,"lr_positive":430.9645390070799,"lr_negative":0.34804467171024683,"diagnostic_odds_ratio":1238.2448979591836,"baseline_entropy_bits_observed":0.457618411899572,"conditional_entropy_bits_observed":0.21800838436383613,"information_bits_observed":0.23961002753573585,"information_fraction_observed":0.5236022443701854,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"aee3643ddc4e"},{"id":"diagnostics-2024:345:e4daaae4676c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Netherlands criteria","test_or_feature":"Netherlands criteria","target_condition":"Gout","citation":"Jatuworapruk, K et al. Performance of the Existing Classification Criteria for Gout in Thai Patients Presenting With Acute Arthritis. Medicine. 2016;95(5):p e2730. doi: 10.1097/MD.0000000000002734","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"345","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":345,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.88,"specificity":0.76},"tp":120.0,"fp":23.0,"fn":16.0,"tn":74.0,"sample_size":233.0,"observed_prevalence":0.5836909871244635,"sensitivity":0.8823529411764706,"specificity":0.7628865979381443,"ppv_observed":0.8391608391608392,"npv_observed":0.8222222222222222,"youden_j":0.6452395391146148,"lr_positive":3.7212276214833753,"lr_negative":0.1542130365659778,"diagnostic_odds_ratio":24.130434782608695,"baseline_entropy_bits_observed":0.9796947622414152,"conditional_entropy_bits_observed":0.6513306193566721,"information_bits_observed":0.328364142884743,"information_fraction_observed":0.33516984630344276,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e31cf2548496"},{"id":"diagnostics-2024:346:30d0e0225b63","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Mexico criteria","test_or_feature":"Mexico criteria","target_condition":"Gout","citation":"Jatuworapruk, K et al. Performance of the Existing Classification Criteria for Gout in Thai Patients Presenting With Acute Arthritis. Medicine. 2016;95(5):p e2730. doi: 10.1097/MD.0000000000002733","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"346","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":346,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.97,"specificity":0.68},"tp":132.0,"fp":31.0,"fn":4.0,"tn":66.0,"sample_size":233.0,"observed_prevalence":0.5836909871244635,"sensitivity":0.9705882352941176,"specificity":0.6804123711340206,"ppv_observed":0.8098159509202454,"npv_observed":0.9428571428571428,"youden_j":0.6510006064281382,"lr_positive":3.037001897533207,"lr_negative":0.04322638146167559,"diagnostic_odds_ratio":70.25806451612904,"baseline_entropy_bits_observed":0.9796947622414152,"conditional_entropy_bits_observed":0.5859329573856068,"information_bits_observed":0.39376180485580836,"information_fraction_observed":0.40192294583154875,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c0051b8f012b"},{"id":"diagnostics-2024:347:afb965f4951c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ARA criteria","test_or_feature":"ARA criteria","target_condition":"Gout","citation":"Jatuworapruk, K et al. Performance of the Existing Classification Criteria for Gout in Thai Patients Presenting With Acute Arthritis. Medicine. 2016;95(5):p e2730. doi: 10.1097/MD.0000000000002732","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"347","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":347,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.85,"specificity":0.78},"tp":116.0,"fp":21.0,"fn":20.0,"tn":76.0,"sample_size":233.0,"observed_prevalence":0.5836909871244635,"sensitivity":0.8529411764705882,"specificity":0.7835051546391752,"ppv_observed":0.8467153284671532,"npv_observed":0.7916666666666666,"youden_j":0.6364463311097635,"lr_positive":3.9397759103641454,"lr_negative":0.18769349845201241,"diagnostic_odds_ratio":20.99047619047619,"baseline_entropy_bits_observed":0.9796947622414152,"conditional_entropy_bits_observed":0.6675591467906055,"information_bits_observed":0.3121356154508097,"information_fraction_observed":0.31860496501653607,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"713210607a0f"},{"id":"diagnostics-2024:348:565216077682","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"New York criteria","test_or_feature":"New York criteria","target_condition":"Gout","citation":"Jatuworapruk, K et al. Performance of the Existing Classification Criteria for Gout in Thai Patients Presenting With Acute Arthritis. Medicine. 2016;95(5):p e2730. doi: 10.1097/MD.0000000000002731","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"348","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":348,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.79,"specificity":0.79},"tp":108.0,"fp":20.0,"fn":28.0,"tn":77.0,"sample_size":233.0,"observed_prevalence":0.5836909871244635,"sensitivity":0.7941176470588235,"specificity":0.7938144329896907,"ppv_observed":0.84375,"npv_observed":0.7333333333333333,"youden_j":0.5879320800485142,"lr_positive":3.851470588235293,"lr_negative":0.25935828877005357,"diagnostic_odds_ratio":14.85,"baseline_entropy_bits_observed":0.9796947622414152,"conditional_entropy_bits_observed":0.7205187372206898,"information_bits_observed":0.25917602502072534,"information_fraction_observed":0.2645477295680994,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"21b9253a00d2"},{"id":"diagnostics-2024:349:89446ad4cccc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rome criteria","test_or_feature":"Rome criteria","target_condition":"Gout","citation":"Jatuworapruk, K et al. Performance of the Existing Classification Criteria for Gout in Thai Patients Presenting With Acute Arthritis. Medicine. 2016;95(5):p e2730. doi: 10.1097/MD.0000000000002730","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"349","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":349,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.76,"specificity":0.81},"tp":103.0,"fp":18.0,"fn":33.0,"tn":79.0,"sample_size":233.0,"observed_prevalence":0.5836909871244635,"sensitivity":0.7573529411764706,"specificity":0.8144329896907216,"ppv_observed":0.8512396694214877,"npv_observed":0.7053571428571429,"youden_j":0.5717859308671922,"lr_positive":4.081290849673202,"lr_negative":0.297933730454207,"diagnostic_odds_ratio":13.698653198653199,"baseline_entropy_bits_observed":0.9796947622414152,"conditional_entropy_bits_observed":0.7355120755795037,"information_bits_observed":0.24418268666191145,"information_fraction_observed":0.2492436379911361,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"21bfbc15d923"},{"id":"diagnostics-2024:350:7e5d48163f81","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Homocysteine levels","test_or_feature":"Homocysteine levels","target_condition":"Vitamin B12 deficiency","citation":"Jarquin Campos A, Risch L, Nydegger U, et al. Diagnostic Accuracy of Holotranscobalamin, Vitamin B12, Methylmalonic Acid, and Homocysteine in Detecting B12 Deficiency in a Large, Mixed Patient Population. Dis Markers. 2020;2020:7468506. Published 2020 Feb 7. doi:10.1155/2020/7468509","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"350","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":350,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.68,"specificity":0.77},"tp":655.0,"fp":2532.0,"fn":312.0,"tn":8334.0,"sample_size":11833.0,"observed_prevalence":0.08172061184822108,"sensitivity":0.6773526370217167,"specificity":0.76697956929873,"ppv_observed":0.20552243489174774,"npv_observed":0.963913948646773,"youden_j":0.4443322063204467,"lr_positive":2.9068379754652347,"lr_negative":0.4206726957189857,"diagnostic_odds_ratio":6.909975391906672,"baseline_entropy_bits_observed":0.4082130448832538,"conditional_entropy_bits_observed":0.36108196486259836,"information_bits_observed":0.047131080020655414,"information_fraction_observed":0.11545706491112892,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a9d09377cb6f"},{"id":"diagnostics-2024:351:6a135d9caaf8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Methylmalonic acid levels","test_or_feature":"Methylmalonic acid levels","target_condition":"Vitamin B12 deficiency","citation":"Jarquin Campos A, Risch L, Nydegger U, et al. Diagnostic Accuracy of Holotranscobalamin, Vitamin B12, Methylmalonic Acid, and Homocysteine in Detecting B12 Deficiency in a Large, Mixed Patient Population. Dis Markers. 2020;2020:7468506. Published 2020 Feb 7. doi:10.1155/2020/7468508","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"351","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":351,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.82,"specificity":0.83},"tp":791.0,"fp":1804.0,"fn":176.0,"tn":9062.0,"sample_size":11833.0,"observed_prevalence":0.08172061184822108,"sensitivity":0.8179937952430196,"specificity":0.8339775446346401,"ppv_observed":0.3048169556840077,"npv_observed":0.9809482571985279,"youden_j":0.6519713398776599,"lr_positive":4.927006972899473,"lr_negative":0.2182387354766441,"diagnostic_odds_ratio":22.57622581132836,"baseline_entropy_bits_observed":0.4082130448832538,"conditional_entropy_bits_observed":0.30078221044127657,"information_bits_observed":0.10743083444197721,"information_fraction_observed":0.2631734477586372,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"be505cd52fad"},{"id":"diagnostics-2024:352:427a0ae0b52c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Vitamin B12 levels","test_or_feature":"Vitamin B12 levels","target_condition":"Vitamin B12 deficiency","citation":"Jarquin Campos A, Risch L, Nydegger U, et al. Diagnostic Accuracy of Holotranscobalamin, Vitamin B12, Methylmalonic Acid, and Homocysteine in Detecting B12 Deficiency in a Large, Mixed Patient Population. Dis Markers. 2020;2020:7468506. Published 2020 Feb 7. doi:10.1155/2020/7468507","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"352","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":352,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.86,"specificity":0.78},"tp":833.0,"fp":2423.0,"fn":134.0,"tn":8443.0,"sample_size":11833.0,"observed_prevalence":0.08172061184822108,"sensitivity":0.8614270941054809,"specificity":0.7770108595619363,"ppv_observed":0.2558353808353808,"npv_observed":0.9843768217325405,"youden_j":0.6384379536674172,"lr_positive":3.8630898904457918,"lr_negative":0.1783410156875334,"diagnostic_odds_ratio":21.661253164634935,"baseline_entropy_bits_observed":0.4082130448832538,"conditional_entropy_bits_observed":0.3098991888680791,"information_bits_observed":0.09831385601517467,"information_fraction_observed":0.2408395744513549,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"233c69bd2555"},{"id":"diagnostics-2024:353:2c9a5d078c92","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Holotranscobalamin levels","test_or_feature":"Holotranscobalamin levels","target_condition":"Vitamin B12 deficiency","citation":"Jarquin Campos A, Risch L, Nydegger U, et al. Diagnostic Accuracy of Holotranscobalamin, Vitamin B12, Methylmalonic Acid, and Homocysteine in Detecting B12 Deficiency in a Large, Mixed Patient Population. Dis Markers. 2020;2020:7468506. Published 2020 Feb 7. doi:10.1155/2020/7468506","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"353","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":353,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.86,"specificity":0.81},"tp":829.0,"fp":2043.0,"fn":138.0,"tn":8823.0,"sample_size":11833.0,"observed_prevalence":0.08172061184822108,"sensitivity":0.8572905894519132,"specificity":0.811982330204307,"ppv_observed":0.2886490250696379,"npv_observed":0.9845999330431872,"youden_j":0.6692729196562202,"lr_positive":4.559627775322803,"lr_negative":0.17575433016156766,"diagnostic_odds_ratio":25.943188831428632,"baseline_entropy_bits_observed":0.4082130448832538,"conditional_entropy_bits_observed":0.29733582833671957,"information_bits_observed":0.11087721654653421,"information_fraction_observed":0.2716160542548177,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"df039114e171"},{"id":"diagnostics-2024:354:1cb2857cf486","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Echocardiography","test_or_feature":"Echocardiography","target_condition":"Pulmonary hypertension","citation":"Janda S, Shahidi N, Gin K, Swiston J. Diagnostic accuracy of echocardiography for pulmonary hypertension: a systematic review and meta-analysis [published correction appears in Heart. 2011 Jul;97(13):1112]. Heart. 2011;97(8):612-622. doi:10.1136/hrt.2010.212084","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"354","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":354,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.77,"specificity":0.66},"tp":323.0,"fp":126.0,"fn":99.0,"tn":245.0,"sample_size":793.0,"observed_prevalence":0.532156368221942,"sensitivity":0.7654028436018957,"specificity":0.660377358490566,"ppv_observed":0.7193763919821826,"npv_observed":0.7122093023255814,"youden_j":0.4257802020924617,"lr_positive":2.2536861506055814,"lr_negative":0.35524712254570084,"diagnostic_odds_ratio":6.343995510662177,"baseline_entropy_bits_observed":0.9970143541141296,"conditional_entropy_bits_observed":0.8604423508772487,"information_bits_observed":0.1365720032368809,"information_fraction_observed":0.13698097993606953,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"acd5f1429c8b"},{"id":"diagnostics-2024:355:c1ba41d57334","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Speed's test","test_or_feature":"Speed's test","target_condition":"Bicep tendon tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000580","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"355","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":355,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.75,"specificity":0.45},"tp":12.0,"fp":87.0,"fn":4.0,"tn":70.0,"sample_size":173.0,"observed_prevalence":0.09248554913294797,"sensitivity":0.75,"specificity":0.445859872611465,"ppv_observed":0.12121212121212122,"npv_observed":0.9459459459459459,"youden_j":0.19585987261146487,"lr_positive":1.353448275862069,"lr_negative":0.5607142857142857,"diagnostic_odds_ratio":2.413793103448276,"baseline_entropy_bits_observed":0.4447122878911439,"conditional_entropy_bits_observed":0.4346844457270679,"information_bits_observed":0.01002784216407604,"information_fraction_observed":0.022549055731355554,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c01d9a5fc4bf"},{"id":"diagnostics-2024:356:335f99a079b2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Bicipital groove tenderness","test_or_feature":"Bicipital groove tenderness","target_condition":"Bicep tendon tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000579","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"356","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":356,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.69,"specificity":0.57},"tp":11.0,"fp":72.0,"fn":5.0,"tn":97.0,"sample_size":185.0,"observed_prevalence":0.08648648648648649,"sensitivity":0.6875,"specificity":0.5739644970414202,"ppv_observed":0.13253012048192772,"npv_observed":0.9509803921568627,"youden_j":0.26146449704142016,"lr_positive":1.613715277777778,"lr_negative":0.5444587628865979,"diagnostic_odds_ratio":2.963888888888889,"baseline_entropy_bits_observed":0.4246321376423167,"conditional_entropy_bits_observed":0.40878985733752626,"information_bits_observed":0.015842280304790457,"information_fraction_observed":0.037308246127463376,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e6c3ea3e52b1"},{"id":"diagnostics-2024:357:17e309ad41a6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hawkin's sign","test_or_feature":"Hawkin's sign","target_condition":"Supraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000578","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"357","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":357,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.64,"specificity":0.48},"tp":43.0,"fp":58.0,"fn":24.0,"tn":53.0,"sample_size":178.0,"observed_prevalence":0.37640449438202245,"sensitivity":0.6417910447761194,"specificity":0.4774774774774775,"ppv_observed":0.42574257425742573,"npv_observed":0.6883116883116883,"youden_j":0.11926852225359674,"lr_positive":1.228255275347401,"lr_negative":0.7502112081103915,"diagnostic_odds_ratio":1.6372126436781609,"baseline_entropy_bits_observed":0.9554629988004846,"conditional_entropy_bits_observed":0.9455660511948989,"information_bits_observed":0.009896947605585682,"information_fraction_observed":0.01035827407027859,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cf18706b0c09"},{"id":"diagnostics-2024:358:665c9d45e9bc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Neer's sign","test_or_feature":"Neer's sign","target_condition":"Supraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000577","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"358","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":358,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.6,"specificity":0.58},"tp":40.0,"fp":47.0,"fn":27.0,"tn":65.0,"sample_size":179.0,"observed_prevalence":0.3743016759776536,"sensitivity":0.5970149253731343,"specificity":0.5803571428571429,"ppv_observed":0.45977011494252873,"npv_observed":0.7065217391304348,"youden_j":0.17737206823027707,"lr_positive":1.4226738647189585,"lr_negative":0.6943742824339839,"diagnostic_odds_ratio":2.048857368006304,"baseline_entropy_bits_observed":0.9539178608892709,"conditional_entropy_bits_observed":0.9325425355669157,"information_bits_observed":0.0213753253223552,"information_fraction_observed":0.022407930702155507,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2bfb64837032"},{"id":"diagnostics-2024:359:145589c9a877","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Empty can test","test_or_feature":"Empty can test","target_condition":"Supraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000576","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"359","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":359,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.88,"specificity":0.62},"tp":58.0,"fp":44.0,"fn":8.0,"tn":71.0,"sample_size":181.0,"observed_prevalence":0.36464088397790057,"sensitivity":0.8787878787878788,"specificity":0.6173913043478261,"ppv_observed":0.5686274509803921,"npv_observed":0.8987341772151899,"youden_j":0.49617918313570497,"lr_positive":2.296831955922865,"lr_negative":0.19632949210414,"diagnostic_odds_ratio":11.698863636363637,"baseline_entropy_bits_observed":0.9464681647834203,"conditional_entropy_bits_observed":0.7622990583691216,"information_bits_observed":0.18416910641429873,"information_fraction_observed":0.19458563242477578,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"febd40f0585c"},{"id":"diagnostics-2024:360:fe0df715a781","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Drop arm test","test_or_feature":"Drop arm test","target_condition":"Supraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000575","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"360","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":360,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.24,"specificity":0.96},"tp":16.0,"fp":4.0,"fn":51.0,"tn":104.0,"sample_size":175.0,"observed_prevalence":0.38285714285714284,"sensitivity":0.23880597014925373,"specificity":0.9629629629629629,"ppv_observed":0.8,"npv_observed":0.6709677419354839,"youden_j":0.20176893311221655,"lr_positive":6.447761194029841,"lr_negative":0.7904707233065442,"diagnostic_odds_ratio":8.156862745098039,"baseline_entropy_bits_observed":0.9600349632933267,"conditional_entropy_bits_observed":0.8919909805030527,"information_bits_observed":0.06804398279027402,"information_fraction_observed":0.07087656740839346,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b6c759713298"},{"id":"diagnostics-2024:361:7801e4f4605d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Full can test","test_or_feature":"Full can test","target_condition":"Supraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000574","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"361","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":361,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.7,"specificity":0.81},"tp":45.0,"fp":21.0,"fn":19.0,"tn":91.0,"sample_size":176.0,"observed_prevalence":0.36363636363636365,"sensitivity":0.703125,"specificity":0.8125,"ppv_observed":0.6818181818181818,"npv_observed":0.8272727272727273,"youden_j":0.515625,"lr_positive":3.75,"lr_negative":0.36538461538461536,"diagnostic_odds_ratio":10.263157894736842,"baseline_entropy_bits_observed":0.9456603046006401,"conditional_entropy_bits_observed":0.7533385803333619,"information_bits_observed":0.19232172426727823,"information_fraction_observed":0.2033729483321151,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"dbe2b940845d"},{"id":"diagnostics-2024:362:0e33b3a4163c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hornblower's sign","test_or_feature":"Hornblower's sign","target_condition":"Infraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000573","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"362","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":362,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.17,"specificity":0.96},"tp":11.0,"fp":4.0,"fn":53.0,"tn":108.0,"sample_size":176.0,"observed_prevalence":0.36363636363636365,"sensitivity":0.171875,"specificity":0.9642857142857143,"ppv_observed":0.7333333333333333,"npv_observed":0.6708074534161491,"youden_j":0.1361607142857144,"lr_positive":4.812500000000002,"lr_negative":0.8587962962962963,"diagnostic_odds_ratio":5.60377358490566,"baseline_entropy_bits_observed":0.9456603046006401,"conditional_entropy_bits_observed":0.9074976942049244,"information_bits_observed":0.03816261039571567,"information_fraction_observed":0.04035551689127106,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"26e0bf55b079"},{"id":"diagnostics-2024:363:2dd0743094bc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"External rotation lag sign (90 degrees)","test_or_feature":"External rotation lag sign (90 degrees)","target_condition":"Infraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000572","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"363","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":363,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.08,"specificity":1.0},"tp":5.0,"fp":0.0,"fn":58.0,"tn":112.0,"sample_size":175.0,"observed_prevalence":0.36,"sensitivity":0.07936507936507936,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.6588235294117647,"youden_j":0.0793650793650793,"lr_positive":null,"lr_negative":0.9206349206349207,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9426831892554922,"conditional_entropy_bits_observed":0.899484629460334,"information_bits_observed":0.04319855979515819,"information_fraction_observed":0.04582510888867695,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2f1e7ca5dfa9"},{"id":"diagnostics-2024:364:1d176f21774e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"External rotation lag sign (0 degrees)","test_or_feature":"External rotation lag sign (0 degrees)","target_condition":"Infraspinatus tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000571","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"364","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":364,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.1,"specificity":0.98},"tp":7.0,"fp":2.0,"fn":60.0,"tn":114.0,"sample_size":183.0,"observed_prevalence":0.366120218579235,"sensitivity":0.1044776119402985,"specificity":0.9827586206896551,"ppv_observed":0.7777777777777778,"npv_observed":0.6551724137931034,"youden_j":0.08723623262995361,"lr_positive":6.059701492537301,"lr_negative":0.9112333071484683,"diagnostic_odds_ratio":6.65,"baseline_entropy_bits_observed":0.9476464437732821,"conditional_entropy_bits_observed":0.921241046365927,"information_bits_observed":0.026405397407355147,"information_fraction_observed":0.027864186670944185,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7236c683ee3c"},{"id":"diagnostics-2024:365:76181a2dd688","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Bear hug test","test_or_feature":"Bear hug test","target_condition":"Subscapularis tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000570","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"365","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":365,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.32,"specificity":0.81},"tp":20.0,"fp":21.0,"fn":43.0,"tn":91.0,"sample_size":175.0,"observed_prevalence":0.36,"sensitivity":0.31746031746031744,"specificity":0.8125,"ppv_observed":0.4878048780487805,"npv_observed":0.6791044776119403,"youden_j":0.12996031746031744,"lr_positive":1.693121693121693,"lr_negative":0.8400488400488401,"diagnostic_odds_ratio":2.0155038759689923,"baseline_entropy_bits_observed":0.9426831892554922,"conditional_entropy_bits_observed":0.9274266241389151,"information_bits_observed":0.015256565116577137,"information_fraction_observed":0.016184191349191655,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"94d803fe3b67"},{"id":"diagnostics-2024:366:4ce92375ef98","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Belly-off sign","test_or_feature":"Belly-off sign","target_condition":"Subscapularis tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000569","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"366","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":366,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.18,"specificity":0.96},"tp":11.0,"fp":4.0,"fn":51.0,"tn":104.0,"sample_size":170.0,"observed_prevalence":0.36470588235294116,"sensitivity":0.1774193548387097,"specificity":0.9629629629629629,"ppv_observed":0.7333333333333333,"npv_observed":0.6709677419354839,"youden_j":0.14038231780167254,"lr_positive":4.790322580645155,"lr_negative":0.8542183622828784,"diagnostic_odds_ratio":5.607843137254902,"baseline_entropy_bits_observed":0.9465202215633437,"conditional_entropy_bits_observed":0.9071145342317911,"information_bits_observed":0.039405687331552586,"information_fraction_observed":0.04163216636456768,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b861f30ce9a5"},{"id":"diagnostics-2024:367:d28f94d56321","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Belly-press test","test_or_feature":"Belly-press test","target_condition":"Subscapularis tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000568","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"367","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":367,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.28,"specificity":0.77},"tp":18.0,"fp":14.0,"fn":46.0,"tn":47.0,"sample_size":125.0,"observed_prevalence":0.512,"sensitivity":0.28125,"specificity":0.7704918032786885,"ppv_observed":0.5625,"npv_observed":0.5053763440860215,"youden_j":0.05174180327868849,"lr_positive":1.2254464285714284,"lr_negative":0.9328457446808511,"diagnostic_odds_ratio":1.313664596273292,"baseline_entropy_bits_observed":0.9995844639313985,"conditional_entropy_bits_observed":0.9970449959264585,"information_bits_observed":0.002539468004940093,"information_fraction_observed":0.0025405236841639996,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9205f6d2ee1d"},{"id":"diagnostics-2024:368:cf3b465b846f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Passive lift off","test_or_feature":"Passive lift off","target_condition":"Subscapularis tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000567","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"368","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":368,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.19,"specificity":0.95},"tp":11.0,"fp":5.0,"fn":48.0,"tn":96.0,"sample_size":160.0,"observed_prevalence":0.36875,"sensitivity":0.1864406779661017,"specificity":0.9504950495049505,"ppv_observed":0.6875,"npv_observed":0.6666666666666666,"youden_j":0.1369357274710521,"lr_positive":3.766101694915251,"lr_negative":0.8559322033898306,"diagnostic_odds_ratio":4.4,"baseline_entropy_bits_observed":0.949707471948113,"conditional_entropy_bits_observed":0.9160700739024964,"information_bits_observed":0.03363739804561661,"information_fraction_observed":0.035418693691665906,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7de809b3546d"},{"id":"diagnostics-2024:369:3850758c1509","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lift off test","test_or_feature":"Lift off test","target_condition":"Subscapularis tear","citation":"Jain NB, Luz J, Higgins LD, et al. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study. Am J Phys Med Rehabil. 2017;96(3):176-183. doi:10.1097/PHM.0000000000000566","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"369","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":369,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.22,"specificity":0.94},"tp":13.0,"fp":6.0,"fn":45.0,"tn":96.0,"sample_size":160.0,"observed_prevalence":0.3625,"sensitivity":0.22413793103448276,"specificity":0.9411764705882353,"ppv_observed":0.6842105263157895,"npv_observed":0.6808510638297872,"youden_j":0.16531440162271815,"lr_positive":3.810344827586206,"lr_negative":0.8243534482758621,"diagnostic_odds_ratio":4.622222222222222,"baseline_entropy_bits_observed":0.9447388286467892,"conditional_entropy_bits_observed":0.9030130168714409,"information_bits_observed":0.04172581177534829,"information_fraction_observed":0.04416650455143765,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"745cf2a237af"},{"id":"diagnostics-2024:370:a609eaa1db17","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pelvic examination","test_or_feature":"Pelvic examination","target_condition":"Pelvic inflammatory disease","citation":"Iwata H, Sugiyama Y, Satoi Y, Sasamoto N, Aoki T, Matsushima M. Diagnostic accuracy of pelvic examination in pelvic inflammatory disease: A meta-analysis. J Gen Fam Med. 2022;23(6):384-392. Published 2022 Aug 3. doi:10.1002/jgf2.572","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"370","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":370,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.84,"specificity":0.36},"tp":1319.0,"fp":791.0,"fn":251.0,"tn":442.0,"sample_size":2803.0,"observed_prevalence":0.560114163396361,"sensitivity":0.8401273885350319,"specificity":0.3584752635847526,"ppv_observed":0.6251184834123222,"npv_observed":0.6378066378066378,"youden_j":0.19860265211978456,"lr_positive":1.3095791024825465,"lr_negative":0.44597947949390426,"diagnostic_odds_ratio":2.936411119113936,"baseline_entropy_bits_observed":0.9895477629598168,"conditional_entropy_bits_observed":0.9519094359658089,"information_bits_observed":0.03763832699400793,"information_fraction_observed":0.03803588710203201,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"670636909fc5"},{"id":"diagnostics-2024:371:a3e4cd7a7ad9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Coarse skin, bradycardia, and delayed Achilles reflex","test_or_feature":"Coarse skin, bradycardia, and delayed Achilles reflex","target_condition":"Hypothyroidism","citation":"Indra R, Patil SS, Joshi R, Pai M, Kalantri SP. Accuracy of physical examination in the diagnosis of hypothyroidism: a cross-sectional, double-blind study. J Postgrad Med. 2004;50(1):7-11.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"371","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":371,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.61,"specificity":0.84},"tp":14.0,"fp":17.0,"fn":9.0,"tn":90.0,"sample_size":130.0,"observed_prevalence":0.17692307692307693,"sensitivity":0.6086956521739131,"specificity":0.8411214953271028,"ppv_observed":0.45161290322580644,"npv_observed":0.9090909090909091,"youden_j":0.44981714750101576,"lr_positive":3.8312020460358056,"lr_negative":0.4652173913043478,"diagnostic_odds_ratio":8.235294117647058,"baseline_entropy_bits_observed":0.6732994089189621,"conditional_entropy_bits_observed":0.5715419239781595,"information_bits_observed":0.10175748494080261,"information_fraction_observed":0.15113259211705335,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fa73875fcdc4"},{"id":"diagnostics-2024:372:f8a6036ad616","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Bradycardia","test_or_feature":"Bradycardia","target_condition":"Hypothyroidism","citation":"Indra R, Patil SS, Joshi R, Pai M, Kalantri SP. Accuracy of physical examination in the diagnosis of hypothyroidism: a cross-sectional, double-blind study. J Postgrad Med. 2004;50(1):7-11.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"372","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":372,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.43,"specificity":0.89},"tp":10.0,"fp":12.0,"fn":13.0,"tn":95.0,"sample_size":130.0,"observed_prevalence":0.17692307692307693,"sensitivity":0.43478260869565216,"specificity":0.8878504672897196,"ppv_observed":0.45454545454545453,"npv_observed":0.8796296296296297,"youden_j":0.3226330759853717,"lr_positive":3.876811594202898,"lr_negative":0.6366132723112129,"diagnostic_odds_ratio":6.089743589743589,"baseline_entropy_bits_observed":0.6732994089189621,"conditional_entropy_bits_observed":0.6088808904528724,"information_bits_observed":0.0644185184660897,"information_fraction_observed":0.09567588744733782,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"916b03624311"},{"id":"diagnostics-2024:373:dcd2e946db74","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Delayed Achilles reflex","test_or_feature":"Delayed Achilles reflex","target_condition":"Hypothyroidism","citation":"Indra R, Patil SS, Joshi R, Pai M, Kalantri SP. Accuracy of physical examination in the diagnosis of hypothyroidism: a cross-sectional, double-blind study. J Postgrad Med. 2004;50(1):7-11.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"373","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":373,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.48,"specificity":0.86},"tp":11.0,"fp":15.0,"fn":12.0,"tn":92.0,"sample_size":130.0,"observed_prevalence":0.17692307692307693,"sensitivity":0.4782608695652174,"specificity":0.8598130841121495,"ppv_observed":0.4230769230769231,"npv_observed":0.8846153846153846,"youden_j":0.3380739536773669,"lr_positive":3.4115942028985504,"lr_negative":0.6068052930056711,"diagnostic_odds_ratio":5.622222222222222,"baseline_entropy_bits_observed":0.6732994089189621,"conditional_entropy_bits_observed":0.609329281948499,"information_bits_observed":0.06397012697046311,"information_fraction_observed":0.0950099259305343,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"355baab5d18e"},{"id":"diagnostics-2024:374:aa41833d700b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Coarse skin","test_or_feature":"Coarse skin","target_condition":"Hypothyroidism","citation":"Indra R, Patil SS, Joshi R, Pai M, Kalantri SP. Accuracy of physical examination in the diagnosis of hypothyroidism: a cross-sectional, double-blind study. J Postgrad Med. 2004;50(1):7-11.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"374","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":374,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.61,"specificity":0.74},"tp":14.0,"fp":28.0,"fn":9.0,"tn":79.0,"sample_size":130.0,"observed_prevalence":0.17692307692307693,"sensitivity":0.6086956521739131,"specificity":0.7383177570093458,"ppv_observed":0.3333333333333333,"npv_observed":0.8977272727272727,"youden_j":0.34701340918325885,"lr_positive":2.326086956521739,"lr_negative":0.5299944964226747,"diagnostic_odds_ratio":4.388888888888889,"baseline_entropy_bits_observed":0.6732994089189621,"conditional_entropy_bits_observed":0.6190031027030676,"information_bits_observed":0.05429630621589454,"information_fraction_observed":0.0806421415148303,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"aff3fde9c33c"},{"id":"diagnostics-2024:375:3b73a547bb8c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Facial edema","test_or_feature":"Facial edema","target_condition":"Hypothyroidism","citation":"Indra R, Patil SS, Joshi R, Pai M, Kalantri SP. Accuracy of physical examination in the diagnosis of hypothyroidism: a cross-sectional, double-blind study. J Postgrad Med. 2004;50(1):7-11.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"375","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":375,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.91,"specificity":0.21},"tp":21.0,"fp":85.0,"fn":2.0,"tn":22.0,"sample_size":130.0,"observed_prevalence":0.17692307692307693,"sensitivity":0.9130434782608695,"specificity":0.205607476635514,"ppv_observed":0.19811320754716982,"npv_observed":0.9166666666666666,"youden_j":0.11865095489638344,"lr_positive":1.1493606138107417,"lr_negative":0.42292490118577103,"diagnostic_odds_ratio":2.7176470588235295,"baseline_entropy_bits_observed":0.6732994089189621,"conditional_entropy_bits_observed":0.6619559780071363,"information_bits_observed":0.01134343091182577,"information_fraction_observed":0.016847528397564742,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e110a508801b"},{"id":"diagnostics-2024:376:69258fd874fd","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pretibial edema","test_or_feature":"Pretibial edema","target_condition":"Hypothyroidism","citation":"Indra R, Patil SS, Joshi R, Pai M, Kalantri SP. Accuracy of physical examination in the diagnosis of hypothyroidism: a cross-sectional, double-blind study. J Postgrad Med. 2004;50(1):7-11.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"376","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":376,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.78,"specificity":0.31},"tp":18.0,"fp":74.0,"fn":5.0,"tn":33.0,"sample_size":130.0,"observed_prevalence":0.17692307692307693,"sensitivity":0.782608695652174,"specificity":0.308411214953271,"ppv_observed":0.1956521739130435,"npv_observed":0.868421052631579,"youden_j":0.09101991060544501,"lr_positive":1.1316098707403055,"lr_negative":0.7048748353096178,"diagnostic_odds_ratio":1.6054054054054054,"baseline_entropy_bits_observed":0.6732994089189621,"conditional_entropy_bits_observed":0.6688930767102443,"information_bits_observed":0.004406332208717778,"information_fraction_observed":0.006544387460242255,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fa1ec1375b2c"},{"id":"diagnostics-2024:377:db38394b38e0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Slow movements","test_or_feature":"Slow movements","target_condition":"Hypothyroidism","citation":"Indra R, Patil SS, Joshi R, Pai M, Kalantri SP. Accuracy of physical examination in the diagnosis of hypothyroidism: a cross-sectional, double-blind study. J Postgrad Med. 2004;50(1):7-11.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"377","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":377,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.87,"specificity":0.13},"tp":20.0,"fp":93.0,"fn":3.0,"tn":14.0,"sample_size":130.0,"observed_prevalence":0.17692307692307693,"sensitivity":0.8695652173913043,"specificity":0.1308411214953271,"ppv_observed":0.17699115044247787,"npv_observed":0.8235294117647058,"youden_j":0.00040633888663133,"lr_positive":1.0004675081813932,"lr_negative":0.9968944099378885,"diagnostic_odds_ratio":1.003584229390681,"baseline_entropy_bits_observed":0.6732994089189621,"conditional_entropy_bits_observed":0.6732992562492915,"information_bits_observed":1.5266967057225855e-07,"information_fraction_observed":2.26748558739094e-07,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"622d2aeaa4ab"},{"id":"diagnostics-2024:378:f8dc93b8733a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"IgG-specific ELISA","test_or_feature":"IgG-specific ELISA","target_condition":"Heparin-induced thrombocytopenia","citation":"Husseinzadeh HD, Gimotty PA, Pishko AM, Buckley M, Warkentin TE, Cuker A. Diagnostic accuracy of IgG-specific versus polyspecific enzyme-linked immunoassays in heparin-induced thrombocytopenia: a systematic review and meta-analysis. J Thromb Haemost. 2017;15(6):1203-1212. doi:10.1111/jth.13692","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"378","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":378,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.97,"specificity":0.87},"tp":151.0,"fp":233.0,"fn":5.0,"tn":1559.0,"sample_size":1948.0,"observed_prevalence":0.08008213552361396,"sensitivity":0.967948717948718,"specificity":0.8699776785714286,"ppv_observed":0.3932291666666667,"npv_observed":0.9968030690537084,"youden_j":0.8379263965201464,"lr_positive":7.444481126884562,"lr_negative":0.03684149931744543,"diagnostic_odds_ratio":202.0678111587983,"baseline_entropy_bits_observed":0.4024685337097871,"conditional_entropy_bits_observed":0.21556392651581402,"information_bits_observed":0.18690460719397306,"information_fraction_observed":0.4643955776397333,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"940a199a8e26"},{"id":"diagnostics-2024:379:aa3e42f8f782","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Polyspecific ELISA","test_or_feature":"Polyspecific ELISA","target_condition":"Heparin-induced thrombocytopenia","citation":"Husseinzadeh HD, Gimotty PA, Pishko AM, Buckley M, Warkentin TE, Cuker A. Diagnostic accuracy of IgG-specific versus polyspecific enzyme-linked immunoassays in heparin-induced thrombocytopenia: a systematic review and meta-analysis. J Thromb Haemost. 2017;15(6):1203-1212. doi:10.1111/jth.13692","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"379","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":379,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.97,"specificity":0.82},"tp":151.0,"fp":323.0,"fn":5.0,"tn":1469.0,"sample_size":1948.0,"observed_prevalence":0.08008213552361396,"sensitivity":0.967948717948718,"specificity":0.8197544642857143,"ppv_observed":0.31856540084388185,"npv_observed":0.9966078697421981,"youden_j":0.7877031822344323,"lr_positive":5.370167500198461,"lr_negative":0.03909863678413712,"diagnostic_odds_ratio":137.34922600619194,"baseline_entropy_bits_observed":0.4024685337097871,"conditional_entropy_bits_observed":0.2444318738029112,"information_bits_observed":0.15803665990687588,"information_fraction_observed":0.39266836204599614,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6be8e31d90db"},{"id":"diagnostics-2024:380:0f31161aa0df","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"OSOM saline","test_or_feature":"OSOM saline","target_condition":"Vaginal Trichomonas vaginalis infection","citation":"Huppert JS, Batteiger BE, Braslins P, et al. Use of an immunochromatographic assay for rapid detection of Trichomonas vaginalis in vaginal specimens. J Clin Microbiol. 2005;43(2):684-687. doi:10.1128/JCM.43.2.684-687.2007","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"380","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":380,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.75,"specificity":0.99},"tp":79.0,"fp":5.0,"fn":26.0,"tn":337.0,"sample_size":447.0,"observed_prevalence":0.2348993288590604,"sensitivity":0.7523809523809524,"specificity":0.9853801169590644,"ppv_observed":0.9404761904761905,"npv_observed":0.928374655647383,"youden_j":0.7377610693400167,"lr_positive":51.462857142857246,"lr_negative":0.2512929207291225,"diagnostic_odds_ratio":204.7923076923077,"baseline_entropy_bits_observed":0.7864546465839443,"conditional_entropy_bits_observed":0.3632390221375633,"information_bits_observed":0.42321562444638094,"information_fraction_observed":0.5381309987609157,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4d189b2326fc"},{"id":"diagnostics-2024:381:701cde67388c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Wet mount","test_or_feature":"Wet mount","target_condition":"Vaginal Trichomonas vaginalis infection","citation":"Huppert JS, Batteiger BE, Braslins P, et al. Use of an immunochromatographic assay for rapid detection of Trichomonas vaginalis in vaginal specimens. J Clin Microbiol. 2005;43(2):684-687. doi:10.1128/JCM.43.2.684-687.2006","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"381","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":381,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.71,"specificity":1.0},"tp":75.0,"fp":0.0,"fn":30.0,"tn":344.0,"sample_size":449.0,"observed_prevalence":0.23385300668151449,"sensitivity":0.7142857142857143,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9197860962566845,"youden_j":0.7142857142857144,"lr_positive":null,"lr_negative":0.2857142857142857,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.7846677261165043,"conditional_entropy_bits_observed":0.33562747107393953,"information_bits_observed":0.44904025504256473,"information_fraction_observed":0.572268031546251,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2a516d303114"},{"id":"diagnostics-2024:382:8d735b758a0a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"OSOM swab","test_or_feature":"OSOM swab","target_condition":"Vaginal Trichomonas vaginalis infection","citation":"Huppert JS, Batteiger BE, Braslins P, et al. Use of an immunochromatographic assay for rapid detection of Trichomonas vaginalis in vaginal specimens. J Clin Microbiol. 2005;43(2):684-687. doi:10.1128/JCM.43.2.684-687.2005","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"382","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":382,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.83,"specificity":0.99},"tp":85.0,"fp":4.0,"fn":17.0,"tn":331.0,"sample_size":437.0,"observed_prevalence":0.2334096109839817,"sensitivity":0.8333333333333334,"specificity":0.9880597014925373,"ppv_observed":0.9550561797752809,"npv_observed":0.9511494252873564,"youden_j":0.8213930348258707,"lr_positive":69.7916666666666,"lr_negative":0.16868076535750248,"diagnostic_odds_ratio":413.75,"baseline_entropy_bits_observed":0.7839078322655578,"conditional_entropy_bits_observed":0.2780365729638841,"information_bits_observed":0.5058712593016736,"information_fraction_observed":0.6453198175602664,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ff7c96b0c369"},{"id":"diagnostics-2024:383:826c44c33826","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ACR criteria","test_or_feature":"ACR criteria","target_condition":"Temporal arteritis","citation":"Hunder GG, Bloch DA, Michel BA, et al. The American College of Rheumatology 1990 criteria for the classification of giant cell arteritis. Arthritis Rheum. 1990;33(8):1122-1128. doi:10.1002/art.1780330810","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"383","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":383,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1990,"source_reported":{"sensitivity":0.93,"specificity":0.91},"tp":200.0,"fp":52.0,"fn":14.0,"tn":541.0,"sample_size":807.0,"observed_prevalence":0.265179677819083,"sensitivity":0.9345794392523364,"specificity":0.9123102866779089,"ppv_observed":0.7936507936507936,"npv_observed":0.9747747747747748,"youden_j":0.8468897259302453,"lr_positive":10.65780014378145,"lr_negative":0.07170867379549814,"diagnostic_odds_ratio":148.62637362637363,"baseline_entropy_bits_observed":0.8344624174839443,"conditional_entropy_bits_observed":0.34615501728795367,"information_bits_observed":0.48830740019599067,"information_fraction_observed":0.585176024665468,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c323a6c82762","condition_context_id":"condition:temporal_arteritis"},{"id":"diagnostics-2024:384:fa4c54aab394","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Chvostek's sign","test_or_feature":"Chvostek's sign","target_condition":"Hypocalcemia","citation":"Hujoel IA. The association between serum calcium levels and Chvostek sign: A population-based study. Neurol Clin Pract. 2016;6(4):321-328. doi:10.1212/CPJ.0000000000000270","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"384","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":384,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.17,"specificity":0.96},"tp":1.0,"fp":122.0,"fn":5.0,"tn":3307.0,"sample_size":3435.0,"observed_prevalence":0.0017467248908296944,"sensitivity":0.16666666666666666,"specificity":0.9644211140274133,"ppv_observed":0.008130081300813009,"npv_observed":0.9984903381642513,"youden_j":0.13108778069408,"lr_positive":4.684426229508199,"lr_negative":0.8640762019957666,"diagnostic_odds_ratio":5.421311475409836,"baseline_entropy_bits_observed":0.018519766277626325,"conditional_entropy_bits_observed":0.01817908320097988,"information_bits_observed":0.000340683076646444,"information_fraction_observed":0.018395646658782204,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ff613ca0c324"},{"id":"diagnostics-2024:385:3abc979f9535","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Nasal secretion tests","test_or_feature":"Nasal secretion tests","target_condition":"Bacterial sinusitis","citation":"Huang SW, Small PA Jr. Rapid diagnosis of bacterial sinusitis in patients using a simple test of nasal secretions. Allergy Asthma Proc. 2008;29(6):640-643. doi:10.2500/aap.2008.29.3163","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"385","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":385,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":1.0,"specificity":0.9},"tp":144.0,"fp":7.0,"fn":0.0,"tn":66.0,"sample_size":217.0,"observed_prevalence":0.663594470046083,"sensitivity":1.0,"specificity":0.9041095890410958,"ppv_observed":0.9536423841059603,"npv_observed":1.0,"youden_j":0.904109589041096,"lr_positive":10.428571428571423,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9213374397904044,"conditional_entropy_bits_observed":0.18837986624880512,"information_bits_observed":0.7329575735415993,"information_fraction_observed":0.7955365123426876,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"89c25c10c30f"},{"id":"diagnostics-2024:386:7c5bc70f73b4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fine-needle biopsy","test_or_feature":"Fine-needle biopsy","target_condition":"Thyroid carcinoma","citation":"Hsiao V, Massoud E, Jensen C, et al. Diagnostic Accuracy of Fine-Needle Biopsy in the Detection of Thyroid Malignancy: A Systematic Review and Meta-analysis. JAMA Surg. 2022;157(12):1105–1113. doi:10.1001/jamasurg.2022.4989","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"386","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":386,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.87,"specificity":0.73},"tp":1660.0,"fp":3932.0,"fn":246.0,"tn":10741.0,"sample_size":16579.0,"observed_prevalence":0.11496471439773207,"sensitivity":0.8709338929695698,"specificity":0.7320248074695018,"ppv_observed":0.2968526466380544,"npv_observed":0.9776099026121781,"youden_j":0.6029587004390717,"lr_positive":3.2500541738409203,"lr_negative":0.1763138430739691,"diagnostic_odds_ratio":18.43334656642599,"baseline_entropy_bits_observed":0.5147117618279412,"conditional_entropy_bits_observed":0.3984377008639997,"information_bits_observed":0.1162740609639415,"information_fraction_observed":0.22590130940666128,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ba7fcbd57d10"},{"id":"diagnostics-2024:387:4dee97f1de53","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Laboratory Risk Indicator for Necrotizing Fasciitis score of 8","test_or_feature":"Laboratory Risk Indicator for Necrotizing Fasciitis score of 8","target_condition":"Necrotizing fascitis","citation":"Hsiao C-T, Chang C-P, Huang T-Y, Chen Y-C, Fann W-C. Prospective Validation of the Laboratory Risk Indicator for Necrotizing Fasciitis (LRINEC) Score for Necrotizing Fasciitis of the Extremities. PLoS ONE. 2020; 15(1): e0227748. doi: https:// doi.org/10.1371/journal.pone.0227749","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"387","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":387,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.27,"specificity":0.93},"tp":29.0,"fp":58.0,"fn":77.0,"tn":767.0,"sample_size":931.0,"observed_prevalence":0.11385606874328678,"sensitivity":0.27358490566037735,"specificity":0.9296969696969697,"ppv_observed":0.3333333333333333,"npv_observed":0.9087677725118484,"youden_j":0.2032818753573471,"lr_positive":3.8915094339622636,"lr_negative":0.7813460923470517,"diagnostic_odds_ratio":4.98051948051948,"baseline_entropy_bits_observed":0.5114385678503393,"conditional_entropy_bits_observed":0.4852120370820059,"information_bits_observed":0.026226530768333367,"information_fraction_observed":0.05127992376204205,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"98d5e3c93726"},{"id":"diagnostics-2024:388:26a774e29a84","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Laboratory Risk Indicator for Necrotizing Fasciitis score of 6","test_or_feature":"Laboratory Risk Indicator for Necrotizing Fasciitis score of 6","target_condition":"Necrotizing fascitis","citation":"Hsiao C-T, Chang C-P, Huang T-Y, Chen Y-C, Fann W-C. Prospective Validation of the Laboratory Risk Indicator for Necrotizing Fasciitis (LRINEC) Score for Necrotizing Fasciitis of the Extremities. PLoS ONE. 2020; 15(1): e0227748. doi: https:// doi.org/10.1371/journal.pone.0227748","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"388","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":388,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.43,"specificity":0.83},"tp":46.0,"fp":140.0,"fn":60.0,"tn":685.0,"sample_size":931.0,"observed_prevalence":0.11385606874328678,"sensitivity":0.4339622641509434,"specificity":0.8303030303030303,"ppv_observed":0.24731182795698925,"npv_observed":0.9194630872483222,"youden_j":0.2642652944539736,"lr_positive":2.5572776280323453,"lr_negative":0.6817242804021484,"diagnostic_odds_ratio":3.751190476190476,"baseline_entropy_bits_observed":0.5114385678503393,"conditional_entropy_bits_observed":0.4845659370443137,"information_bits_observed":0.026872630806025533,"information_fraction_observed":0.05254322316554193,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4d4d249ccffe"},{"id":"diagnostics-2024:389:3a64298409c4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal MRI","test_or_feature":"Abdominal MRI","target_condition":"Cervical cancer staging","citation":"Hricak H, Gatsonis C, Chi DS, et al. Role of imaging in pretreatment evaluation of early invasive cervical cancer: results of the intergroup study American College of Radiology Imaging Network 6651-Gynecologic Oncology Group 183. J Clin Oncol. 2005;23(36):9329-9337. doi:10.1200/JCO.2005.02.0356","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"389","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":389,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.53,"specificity":0.75},"tp":19.0,"fp":32.0,"fn":17.0,"tn":98.0,"sample_size":166.0,"observed_prevalence":0.21686746987951808,"sensitivity":0.5277777777777778,"specificity":0.7538461538461538,"ppv_observed":0.37254901960784315,"npv_observed":0.8521739130434782,"youden_j":0.2816239316239315,"lr_positive":2.1440972222222223,"lr_negative":0.6264172335600907,"diagnostic_odds_ratio":3.422794117647059,"baseline_entropy_bits_observed":0.7544062039636578,"conditional_entropy_bits_observed":0.7113614007179224,"information_bits_observed":0.04304480324573534,"information_fraction_observed":0.057057859571643915,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"471585e87f99"},{"id":"diagnostics-2024:390:b0dd764e4580","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal CT","test_or_feature":"Abdominal CT","target_condition":"Cervical cancer staging","citation":"Hricak H, Gatsonis C, Chi DS, et al. Role of imaging in pretreatment evaluation of early invasive cervical cancer: results of the intergroup study American College of Radiology Imaging Network 6651-Gynecologic Oncology Group 183. J Clin Oncol. 2005;23(36):9329-9337. doi:10.1200/JCO.2005.02.0355","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"390","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":390,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.42,"specificity":0.82},"tp":15.0,"fp":23.0,"fn":21.0,"tn":107.0,"sample_size":166.0,"observed_prevalence":0.21686746987951808,"sensitivity":0.4166666666666667,"specificity":0.823076923076923,"ppv_observed":0.39473684210526316,"npv_observed":0.8359375,"youden_j":0.23974358974358978,"lr_positive":2.3550724637681157,"lr_negative":0.7087227414330217,"diagnostic_odds_ratio":3.3229813664596275,"baseline_entropy_bits_observed":0.7544062039636578,"conditional_entropy_bits_observed":0.7180742660490391,"information_bits_observed":0.03633193791461864,"information_fraction_observed":0.04815964890496694,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8c56c5cfe2c3"},{"id":"diagnostics-2024:391:2a2cc01bfff1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical FIGO guidelines","test_or_feature":"Clinical FIGO guidelines","target_condition":"Cervical cancer staging","citation":"Hricak H, Gatsonis C, Chi DS, et al. Role of imaging in pretreatment evaluation of early invasive cervical cancer: results of the intergroup study American College of Radiology Imaging Network 6651-Gynecologic Oncology Group 183. J Clin Oncol. 2005;23(36):9329-9337. doi:10.1200/JCO.2005.02.0354","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"391","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":391,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.29,"specificity":0.99},"tp":10.0,"fp":1.0,"fn":25.0,"tn":129.0,"sample_size":165.0,"observed_prevalence":0.21212121212121213,"sensitivity":0.2857142857142857,"specificity":0.9923076923076923,"ppv_observed":0.9090909090909091,"npv_observed":0.8376623376623377,"youden_j":0.2780219780219779,"lr_positive":37.142857142857274,"lr_negative":0.7198228128460686,"diagnostic_odds_ratio":51.6,"baseline_entropy_bits_observed":0.7455178428108284,"conditional_entropy_bits_observed":0.6265143844192943,"information_bits_observed":0.11900345839153414,"information_fraction_observed":0.15962523169513287,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cd3a7f9a91f3"},{"id":"diagnostics-2024:392:ba5a72956f20","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fetal fibronectin test, asymptomatic, < 34 weeks","test_or_feature":"Fetal fibronectin test, asymptomatic, < 34 weeks","target_condition":"Risk of preterm labor","citation":"Honest H, Bachmann LM, Gupta JK, Kleijnen J, Khan KS. Accuracy of cervicovaginal fetal fibronectin test in predicting risk of spontaneous preterm birth: systematic review. BMJ. 2002;325(7359):301. doi:10.1136/bmj.325.7359.301","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"392","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":392,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.18,"specificity":0.03},"tp":278.0,"fp":22407.0,"fn":1249.0,"tn":743.0,"sample_size":24677.0,"observed_prevalence":0.06187948291931758,"sensitivity":0.18205631958087753,"specificity":0.032095032397408206,"ppv_observed":0.012254793916685033,"npv_observed":0.3729919678714859,"youden_j":-0.7858486480217143,"lr_positive":0.188093176163579,"lr_negative":25.485055453166467,"diagnostic_odds_ratio":0.007380528424167459,"baseline_entropy_bits_observed":0.334861019310599,"conditional_entropy_bits_observed":0.16461901016468156,"information_bits_observed":0.17024200914591742,"information_fraction_observed":0.5083960190302417,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4ecd698a5807"},{"id":"diagnostics-2024:393:77c5f598fbb8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fetal fibronectin test, asymptomatic < 37 weeks","test_or_feature":"Fetal fibronectin test, asymptomatic < 37 weeks","target_condition":"Risk of preterm labor","citation":"Honest H, Bachmann LM, Gupta JK, Kleijnen J, Khan KS. Accuracy of cervicovaginal fetal fibronectin test in predicting risk of spontaneous preterm birth: systematic review. BMJ. 2002;325(7359):301. doi:10.1136/bmj.325.7359.301","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"393","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":393,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.36,"specificity":0.12},"tp":852.0,"fp":8643.0,"fn":1488.0,"tn":1132.0,"sample_size":12115.0,"observed_prevalence":0.1931489888567891,"sensitivity":0.3641025641025641,"specificity":0.11580562659846547,"ppv_observed":0.08973143759873618,"npv_observed":0.43206106870229005,"youden_j":-0.5200918092989705,"lr_positive":0.4117901844385704,"lr_negative":5.491075473407629,"diagnostic_odds_ratio":0.07499262875420348,"baseline_entropy_bits_observed":0.7080126172244787,"conditional_entropy_bits_observed":0.5547471513876537,"information_bits_observed":0.153265465836825,"information_fraction_observed":0.2164727889139177,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"069727c7edd9"},{"id":"diagnostics-2024:394:60f7089b184e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fetal fibronectin test, symptomatic, < 34 weeks","test_or_feature":"Fetal fibronectin test, symptomatic, < 34 weeks","target_condition":"Risk of preterm labor","citation":"Honest H, Bachmann LM, Gupta JK, Kleijnen J, Khan KS. Accuracy of cervicovaginal fetal fibronectin test in predicting risk of spontaneous preterm birth: systematic review. BMJ. 2002;325(7359):301. doi:10.1136/bmj.325.7359.301","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"394","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":394,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.47,"specificity":0.07},"tp":88.0,"fp":461.0,"fn":101.0,"tn":33.0,"sample_size":683.0,"observed_prevalence":0.2767203513909224,"sensitivity":0.4656084656084656,"specificity":0.06680161943319839,"ppv_observed":0.16029143897996356,"npv_observed":0.2462686567164179,"youden_j":-0.467589914958336,"lr_positive":0.49893835577132756,"lr_negative":7.999679333012666,"diagnostic_odds_ratio":0.062369794463177336,"baseline_entropy_bits_observed":0.8509434804707442,"conditional_entropy_bits_observed":0.6684188169259566,"information_bits_observed":0.18252466354478758,"information_fraction_observed":0.21449681175512908,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7cb8b2f5fe72"},{"id":"diagnostics-2024:395:d51a61d3b3d8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fetal fibronectin test, symptomatic, < 37 weeks","test_or_feature":"Fetal fibronectin test, symptomatic, < 37 weeks","target_condition":"Risk of preterm labor","citation":"Honest H, Bachmann LM, Gupta JK, Kleijnen J, Khan KS. Accuracy of cervicovaginal fetal fibronectin test in predicting risk of spontaneous preterm birth: systematic review. BMJ. 2002;325(7359):301. doi:10.1136/bmj.325.7359.301","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"395","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":395,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.6,"specificity":0.13},"tp":698.0,"fp":3233.0,"fn":474.0,"tn":481.0,"sample_size":4886.0,"observed_prevalence":0.23986901350798198,"sensitivity":0.5955631399317406,"specificity":0.12950996230479267,"ppv_observed":0.17756296107860595,"npv_observed":0.5036649214659686,"youden_j":-0.2749268977634667,"lr_positive":0.6841699665037069,"lr_negative":3.1228243207765396,"diagnostic_odds_ratio":0.21908692139735142,"baseline_entropy_bits_observed":0.7948223855691336,"conditional_entropy_bits_observed":0.7382877370523021,"information_bits_observed":0.05653464851683154,"information_fraction_observed":0.07112865659457972,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6d57d20a597f"},{"id":"diagnostics-2024:396:2d3127d17c3f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NEXUS Criteria for C-spine Imaging","test_or_feature":"NEXUS Criteria for C-spine Imaging","target_condition":"Clinincally significant injury","citation":"Hoffman, J.R. et al. Validity of a set of clinical criteria to rule out injury to the cervical spine in patients with blunt trauma. New England Journal of Medicine. 2000; 343(2): 94–99. doi: https://doi.org/10.1056/nejm200007133430203.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"396","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":396,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":1.0,"specificity":0.13},"tp":576.0,"fp":29814.0,"fn":2.0,"tn":4307.0,"sample_size":34699.0,"observed_prevalence":0.016657540563128622,"sensitivity":0.9965397923875432,"specificity":0.12622725008059552,"ppv_observed":0.01895360315893386,"npv_observed":0.9995358551868183,"youden_j":0.12276704246813863,"lr_positive":1.140502255854812,"lr_negative":0.027412524714334457,"diagnostic_odds_ratio":41.60515194204065,"baseline_entropy_bits_observed":0.12223790779339579,"conditional_entropy_bits_observed":0.11941598237811246,"information_bits_observed":0.0028219254152833245,"information_fraction_observed":0.023085517956122823,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0cc331f543c7"},{"id":"diagnostics-2024:397:9a18800a8bda","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"NEXUS Criteria for C-spine Imaging","test_or_feature":"NEXUS Criteria for C-spine Imaging","target_condition":"Any cervical spine injury","citation":"Hoffman, J.R. et al. Validity of a set of clinical criteria to rule out injury to the cervical spine in patients with blunt trauma. New England Journal of Medicine. 2000; 343(2): 94–99. doi: https://doi.org/10.1056/nejm200007133430203.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"397","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":397,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.99,"specificity":0.13},"tp":810.0,"fp":28950.0,"fn":8.0,"tn":4301.0,"sample_size":34069.0,"observed_prevalence":0.024010097155772108,"sensitivity":0.9902200488997555,"specificity":0.12934949324832337,"ppv_observed":0.02721774193548387,"npv_observed":0.9981434207472731,"youden_j":0.11956954214807891,"lr_positive":1.137333569808835,"lr_negative":0.07560873146575943,"diagnostic_odds_ratio":15.042357512953368,"baseline_entropy_bits_observed":0.16339951716542922,"conditional_entropy_bits_observed":0.1599134017231392,"information_bits_observed":0.003486115442290022,"information_fraction_observed":0.021334918871030707,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d12dbac0fd5d"},{"id":"diagnostics-2024:398:d6002d053bcb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Teddy bear sign","test_or_feature":"Teddy bear sign","target_condition":"Psychogenic nonepileptic seizure","citation":"Hoerth MT, Wellik KE, Demaerschalk BM, et al. Clinical predictors of psychogenic nonepileptic seizures: a critically appraised topic. Neurologist. 2008;14(4):266-270. doi:10.1097/NRL.0b013e31817acee7","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"398","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":398,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.05,"specificity":0.99},"tp":20.0,"fp":5.0,"fn":361.0,"tn":448.0,"sample_size":834.0,"observed_prevalence":0.4568345323741007,"sensitivity":0.05249343832020997,"specificity":0.9889624724061811,"ppv_observed":0.8,"npv_observed":0.553770086526576,"youden_j":0.04145591072639099,"lr_positive":4.755905511811047,"lr_negative":0.9580814116985376,"diagnostic_odds_ratio":4.96398891966759,"baseline_entropy_bits_observed":0.9946170768308745,"conditional_entropy_bits_observed":0.9835566061870031,"information_bits_observed":0.01106047064387139,"information_fraction_observed":0.011120330528722785,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f8ed533e37ff"},{"id":"diagnostics-2024:399:1acd403ba9d4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ictal eye closure","test_or_feature":"Ictal eye closure","target_condition":"Psychogenic nonepileptic seizure","citation":"Hoerth MT, Wellik KE, Demaerschalk BM, et al. Clinical predictors of psychogenic nonepileptic seizures: a critically appraised topic. Neurologist. 2008;14(4):266-270. doi:10.1097/NRL.0b013e31817acee6","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"399","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":399,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.72,"specificity":0.82},"tp":147.0,"fp":85.0,"fn":56.0,"tn":384.0,"sample_size":672.0,"observed_prevalence":0.3020833333333333,"sensitivity":0.7241379310344828,"specificity":0.8187633262260128,"ppv_observed":0.6336206896551724,"npv_observed":0.8727272727272727,"youden_j":0.5429012572604957,"lr_positive":3.9955375253549694,"lr_negative":0.3369252873563218,"diagnostic_odds_ratio":11.858823529411765,"baseline_entropy_bits_observed":0.8838226609360484,"conditional_entropy_bits_observed":0.687295125960784,"information_bits_observed":0.19652753497526443,"information_fraction_observed":0.2223608237959456,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"857646ac85bd"},{"id":"diagnostics-2024:400:93e4d71d583e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ictal stutter","test_or_feature":"Ictal stutter","target_condition":"Psychogenic nonepileptic seizure","citation":"Hoerth MT, Wellik KE, Demaerschalk BM, et al. Clinical predictors of psychogenic nonepileptic seizures: a critically appraised topic. Neurologist. 2008;14(4):266-270. doi:10.1097/NRL.0b013e31817acee5","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"400","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":400,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.09,"specificity":1.0},"tp":11.0,"fp":0.0,"fn":106.0,"tn":113.0,"sample_size":230.0,"observed_prevalence":0.508695652173913,"sensitivity":0.09401709401709402,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.5159817351598174,"youden_j":0.09401709401709413,"lr_positive":null,"lr_negative":0.905982905982906,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9997818120566598,"conditional_entropy_bits_observed":0.9514720657219202,"information_bits_observed":0.04830974633473961,"information_fraction_observed":0.04832028923927033,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2c3bbe023810"},{"id":"diagnostics-2024:401:e57a73ec10e9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pelvic thrusting","test_or_feature":"Pelvic thrusting","target_condition":"Psychogenic nonepileptic seizure","citation":"Hoerth MT, Wellik KE, Demaerschalk BM, et al. Clinical predictors of psychogenic nonepileptic seizures: a critically appraised topic. Neurologist. 2008;14(4):266-270. doi:10.1097/NRL.0b013e31817acee4","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"401","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":401,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.78,"specificity":0.76},"tp":78.0,"fp":36.0,"fn":22.0,"tn":114.0,"sample_size":250.0,"observed_prevalence":0.4,"sensitivity":0.78,"specificity":0.76,"ppv_observed":0.6842105263157895,"npv_observed":0.8382352941176471,"youden_j":0.54,"lr_positive":3.2500000000000004,"lr_negative":0.28947368421052627,"diagnostic_odds_ratio":11.227272727272727,"baseline_entropy_bits_observed":0.9709505944546686,"conditional_entropy_bits_observed":0.757635110707388,"information_bits_observed":0.2133154837472806,"information_fraction_observed":0.21969756748239963,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"553c2b4fd663"},{"id":"diagnostics-2024:402:a6bb327b56ce","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hyperventilation test","test_or_feature":"Hyperventilation test","target_condition":"Syncope","citation":"Hoefnagels WA, Padberg GW, Overweg J, Roos RA, van Dijk JG, Kamphuisen HA. Syncope or seizure? The diagnostic value of the EEG and hyperventilation test in transient loss of consciousness. J Neurol Neurosurg Psychiatry. 1991;54(11):953-956. doi:10.1136/jnnp.54.11.953","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"402","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":402,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1991,"source_reported":{"sensitivity":0.57,"specificity":0.84},"tp":26.0,"fp":6.0,"fn":20.0,"tn":31.0,"sample_size":83.0,"observed_prevalence":0.5542168674698795,"sensitivity":0.5652173913043478,"specificity":0.8378378378378378,"ppv_observed":0.8125,"npv_observed":0.6078431372549019,"youden_j":0.4030552291421856,"lr_positive":3.485507246376811,"lr_negative":0.5189340813464236,"diagnostic_odds_ratio":6.716666666666667,"baseline_entropy_bits_observed":0.9915017866855546,"conditional_entropy_bits_observed":0.8620944246362718,"information_bits_observed":0.12940736204928271,"information_fraction_observed":0.13051651927110752,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"39045d3755d1"},{"id":"diagnostics-2024:403:ee4586c03b99","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CD38","test_or_feature":"CD38","target_condition":"Tuberculosis","citation":"Hiza, H., Hella, J., Arbués, A. et al. Case–control diagnostic accuracy study of a non-sputum CD38-based TAM-TB test from a single milliliter of blood. Sci Rep. 2021; 11:13190. doi: https://doi.org/10.1038/s41598-021-92596-z","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"403","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":403,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.82,"specificity":0.93},"tp":373.0,"fp":7.0,"fn":81.0,"tn":99.0,"sample_size":560.0,"observed_prevalence":0.8107142857142857,"sensitivity":0.8215859030837004,"specificity":0.9339622641509434,"ppv_observed":0.9815789473684211,"npv_observed":0.55,"youden_j":0.7555481672346438,"lr_positive":12.441157960981752,"lr_negative":0.19102923508209857,"diagnostic_odds_ratio":65.12698412698413,"baseline_entropy_bits_observed":0.6999748358489405,"conditional_entropy_bits_observed":0.4090038919177833,"information_bits_observed":0.2909709439311572,"information_fraction_observed":0.41568772051392827,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5f7b3420a68b"},{"id":"diagnostics-2024:404:9d35d5d94e16","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CD27","test_or_feature":"CD27","target_condition":"Tuberculosis","citation":"Hiza, H., Hella, J., Arbués, A. et al. Case–control diagnostic accuracy study of a non-sputum CD38-based TAM-TB test from a single milliliter of blood. Sci Rep. 2021; 11:13190. doi: https://doi.org/10.1038/s41598-021-92596-z","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"404","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":404,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.8,"specificity":0.77},"tp":364.0,"fp":24.0,"fn":90.0,"tn":82.0,"sample_size":560.0,"observed_prevalence":0.8107142857142857,"sensitivity":0.801762114537445,"specificity":0.7735849056603774,"ppv_observed":0.9381443298969072,"npv_observed":0.47674418604651164,"youden_j":0.5753470201978224,"lr_positive":3.541116005873716,"lr_negative":0.2562587299881809,"diagnostic_odds_ratio":13.818518518518518,"baseline_entropy_bits_observed":0.6999748358489405,"conditional_entropy_bits_observed":0.5386095151417494,"information_bits_observed":0.16136532070719112,"information_fraction_observed":0.23053017400473363,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c72b298caf2f"},{"id":"diagnostics-2024:405:a01bf8769c53","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TTE","test_or_feature":"TTE","target_condition":"Bicuspid aortic valve","citation":"Hillebrand M, Koschyk D, ter Hark P, Schüler H, Rybczynski M, Berger J, Gulati A, Bernhardt AM, Detter C, Girdauskas E, Blankenberg S, von Kodolitsch Y. Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: a retrospective study and meta-analysis. Cardiovasc Diagn Ther 2017;7(4):367-379. doi: 10.21037/cdt.2017.05.03","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"405","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":405,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.8,"specificity":0.81},"tp":555.0,"fp":134.0,"fn":140.0,"tn":555.0,"sample_size":1384.0,"observed_prevalence":0.5021676300578035,"sensitivity":0.7985611510791367,"specificity":0.8055152394775036,"ppv_observed":0.8055152394775036,"npv_observed":0.7985611510791367,"youden_j":0.6040763905566404,"lr_positive":4.106034575324814,"lr_negative":0.2500745349666213,"diagnostic_odds_ratio":16.419243070362473,"baseline_entropy_bits_observed":0.9999864426057916,"conditional_entropy_bits_observed":0.7178084245777345,"information_bits_observed":0.2821780180280571,"information_fraction_observed":0.28218184367855026,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3b7ba150b145"},{"id":"diagnostics-2024:406:69f819877247","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CVA tenderness","test_or_feature":"CVA tenderness","target_condition":"Nephrolithiasis","citation":"Higuchi H, Harada T, Hiroshige J. Evaluation of the usefulness of costovertebral angle tenderness in patients with suspected ureteral stone. J Gen Fam Med. 2022;00:1–3. doi:10.1002/jgf2.581","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"406","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":406,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.65,"specificity":0.5},"tp":52.0,"fp":26.0,"fn":28.0,"tn":26.0,"sample_size":132.0,"observed_prevalence":0.6060606060606061,"sensitivity":0.65,"specificity":0.5,"ppv_observed":0.6666666666666666,"npv_observed":0.48148148148148145,"youden_j":0.1499999999999999,"lr_positive":1.3,"lr_negative":0.7,"diagnostic_odds_ratio":1.8571428571428572,"baseline_entropy_bits_observed":0.9672947789468944,"conditional_entropy_bits_observed":0.9513153763923953,"information_bits_observed":0.015979402554499145,"information_fraction_observed":0.01651968241976465,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"912aa7e7af76"},{"id":"diagnostics-2024:407:51db56be46c7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"FAST exam","test_or_feature":"FAST exam","target_condition":"Hemoperitoneum","citation":"Heydari F, Ashrafi A, Kolahdouzan M. Diagnostic Accuracy of Focused Assessment with Sonography for Blunt Abdominal Trauma in Pediatric Patients Performed by Emergency Medicine Residents versus Radiology Residents. Adv J Emerg Med. 2018;2(3):e31. Published 2018 May 8. doi:10.22114/AJEM.v0i0.89","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"407","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":407,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.82,"specificity":0.86},"tp":115.0,"fp":16.0,"fn":26.0,"tn":99.0,"sample_size":256.0,"observed_prevalence":0.55078125,"sensitivity":0.8156028368794326,"specificity":0.8608695652173913,"ppv_observed":0.8778625954198473,"npv_observed":0.792,"youden_j":0.6764724020968238,"lr_positive":5.862145390070923,"lr_negative":0.21419872483702276,"diagnostic_odds_ratio":27.36778846153846,"baseline_entropy_bits_observed":0.9925464978639333,"conditional_entropy_bits_observed":0.6341888861953671,"information_bits_observed":0.3583576116685663,"information_fraction_observed":0.36104868884207475,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9f7c7de7a79a"},{"id":"diagnostics-2024:408:7cb37240c986","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Oscillometric ankle brachial index","test_or_feature":"Oscillometric ankle brachial index","target_condition":"Peripheral arterial disease","citation":"Herráiz-Adillo Á, Soriano-Cano A, Martínez-Hortelano JA, et al. Simultaneous inter-arm and inter-leg systolic blood pressure differences to diagnose peripheral artery disease: a diagnostic accuracy study. Blood Press. 2018;27(2):112-119. doi:10.1080/08037051.2017.1400905","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"408","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":408,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.78,"specificity":0.98},"tp":18.0,"fp":3.0,"fn":5.0,"tn":145.0,"sample_size":171.0,"observed_prevalence":0.13450292397660818,"sensitivity":0.782608695652174,"specificity":0.9797297297297297,"ppv_observed":0.8571428571428571,"npv_observed":0.9666666666666667,"youden_j":0.7623384253819037,"lr_positive":38.608695652173886,"lr_negative":0.22188905547226384,"diagnostic_odds_ratio":174.0,"baseline_entropy_bits_observed":0.5696593973280274,"conditional_entropy_bits_observed":0.2576109555439105,"information_bits_observed":0.3120484417841169,"information_fraction_observed":0.5477807322195895,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9cfae34b4dc5"},{"id":"diagnostics-2024:409:16a3936667b8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Inter-leg systolic blood pressure difference","test_or_feature":"Inter-leg systolic blood pressure difference","target_condition":"Peripheral arterial disease","citation":"Herráiz-Adillo Á, Soriano-Cano A, Martínez-Hortelano JA, et al. Simultaneous inter-arm and inter-leg systolic blood pressure differences to diagnose peripheral artery disease: a diagnostic accuracy study. Blood Press. 2018;27(2):112-119. doi:10.1080/08037051.2017.1400904","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"409","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":409,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.7,"specificity":0.85},"tp":16.0,"fp":22.0,"fn":7.0,"tn":126.0,"sample_size":171.0,"observed_prevalence":0.13450292397660818,"sensitivity":0.6956521739130435,"specificity":0.8513513513513513,"ppv_observed":0.42105263157894735,"npv_observed":0.9473684210526315,"youden_j":0.5470035252643948,"lr_positive":4.6798418972332,"lr_negative":0.35748792270531404,"diagnostic_odds_ratio":13.090909090909092,"baseline_entropy_bits_observed":0.5696593973280274,"conditional_entropy_bits_observed":0.4495763684625802,"information_bits_observed":0.1200830288654472,"information_fraction_observed":0.2107979424699979,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ebd1e5e0a39e"},{"id":"diagnostics-2024:410:e9f2e1f1d3f3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Inter-arm systolic blood pressure difference","test_or_feature":"Inter-arm systolic blood pressure difference","target_condition":"Peripheral arterial disease","citation":"Herráiz-Adillo Á, Soriano-Cano A, Martínez-Hortelano JA, et al. Simultaneous inter-arm and inter-leg systolic blood pressure differences to diagnose peripheral artery disease: a diagnostic accuracy study. Blood Press. 2018;27(2):112-119. doi:10.1080/08037051.2017.1400903","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"410","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":410,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.13,"specificity":0.93},"tp":3.0,"fp":10.0,"fn":20.0,"tn":138.0,"sample_size":171.0,"observed_prevalence":0.13450292397660818,"sensitivity":0.13043478260869565,"specificity":0.9324324324324325,"ppv_observed":0.23076923076923078,"npv_observed":0.8734177215189873,"youden_j":0.06286721504112802,"lr_positive":1.9304347826086963,"lr_negative":0.9325771896660365,"diagnostic_odds_ratio":2.07,"baseline_entropy_bits_observed":0.5696593973280274,"conditional_entropy_bits_observed":0.5655787670388583,"information_bits_observed":0.004080630289169052,"information_fraction_observed":0.007163280915419182,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2efd52654c70"},{"id":"diagnostics-2024:411:6b51be9e6634","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Physical examination","test_or_feature":"Physical examination","target_condition":"Peripheral arterial disease","citation":"Herráiz-Adillo Á, Piñar-Serrano O, Mariana-Herráiz JÁ, Martínez-Vizcaíno V, Pozuelo-Carrascosa DP, Notario-Pacheco B. Physical examination to screen for peripheral artery disease in a defined Primary Care population: A diagnostic accuracy study. Int J Clin Pract. 2018;72(11):e13253. doi:10.1111/ijcp.13253","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"411","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":411,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.87,"specificity":0.97},"tp":33.0,"fp":2.0,"fn":5.0,"tn":57.0,"sample_size":97.0,"observed_prevalence":0.3917525773195876,"sensitivity":0.868421052631579,"specificity":0.9661016949152542,"ppv_observed":0.9428571428571428,"npv_observed":0.9193548387096774,"youden_j":0.8345227475468331,"lr_positive":25.618421052631565,"lr_negative":0.13619575253924282,"diagnostic_odds_ratio":188.1,"baseline_entropy_bits_observed":0.9659212398860464,"conditional_entropy_bits_observed":0.37253298573612414,"information_bits_observed":0.5933882541499222,"information_fraction_observed":0.6143236421842495,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b0346bc6ab22"},{"id":"diagnostics-2024:412:ce9672e02e96","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical evaluation with unintended weight loss","test_or_feature":"Clinical evaluation with unintended weight loss","target_condition":"Cancer","citation":"Hernández JL, Riancho JA, Matorras P, González-Macías J. Clinical evaluation for cancer in patients with involuntary weight loss without specific symptoms. Am J Med. 2003;114(8):631-637. doi:10.1016/s0002-9343(03)00115-3","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"412","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":412,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2003,"source_reported":{"sensitivity":0.91,"specificity":0.35},"tp":95.0,"fp":112.0,"fn":9.0,"tn":60.0,"sample_size":276.0,"observed_prevalence":0.37681159420289856,"sensitivity":0.9134615384615384,"specificity":0.3488372093023256,"ppv_observed":0.45893719806763283,"npv_observed":0.8695652173913043,"youden_j":0.2622987477638641,"lr_positive":1.4028159340659339,"lr_negative":0.24807692307692314,"diagnostic_odds_ratio":5.654761904761905,"baseline_entropy_bits_observed":0.9557589912150009,"conditional_entropy_bits_observed":0.8860043221328636,"information_bits_observed":0.06975466908213723,"information_fraction_observed":0.07298353426260963,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f3554e0778fe"},{"id":"diagnostics-2024:413:77bbae2dc06c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Acute low back pain and clinical diagnosis of fracture","test_or_feature":"Acute low back pain and clinical diagnosis of fracture","target_condition":"Vertebral fracture","citation":"Henschke N, Maher CG, Refshauge KM, et al. Prevalence of and screening for serious spinal pathology in patients presenting to primary care settings with acute low back pain. Arthritis Rheum. 2009;60(10):3072-3080. doi:10.1002/art.24857","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"413","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":413,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.5,"specificity":1.0},"tp":4.0,"fp":0.0,"fn":4.0,"tn":1164.0,"sample_size":1172.0,"observed_prevalence":0.006825938566552901,"sensitivity":0.5,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9965753424657534,"youden_j":0.5,"lr_positive":null,"lr_negative":0.5,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.05892502921299665,"conditional_entropy_bits_observed":0.032867052582438334,"information_bits_observed":0.026057976630558317,"information_fraction_observed":0.4422225492051331,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"025c01ccfd8c"},{"id":"diagnostics-2024:414:d9d3393d25d9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Acute low back pain and altered sensation","test_or_feature":"Acute low back pain and altered sensation","target_condition":"Vertebral fracture","citation":"Henschke N, Maher CG, Refshauge KM, et al. Prevalence of and screening for serious spinal pathology in patients presenting to primary care settings with acute low back pain. Arthritis Rheum. 2009;60(10):3072-3080. doi:10.1002/art.24856","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"414","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":414,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.0,"specificity":0.98},"tp":0.0,"fp":23.0,"fn":8.0,"tn":1141.0,"sample_size":1172.0,"observed_prevalence":0.006825938566552901,"sensitivity":0.0,"specificity":0.9802405498281787,"ppv_observed":0.0,"npv_observed":0.9930374238468234,"youden_j":-0.019759450171821347,"lr_positive":0.0,"lr_negative":1.0201577563540754,"diagnostic_odds_ratio":0.0,"baseline_entropy_bits_observed":0.05892502921299665,"conditional_entropy_bits_observed":0.0587291739889064,"information_bits_observed":0.00019585522409025502,"information_fraction_observed":0.003323803597657898,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3916bc24ca7d"},{"id":"diagnostics-2024:415:24278cc70535","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Acute low back pain and chronic steroid use","test_or_feature":"Acute low back pain and chronic steroid use","target_condition":"Vertebral fracture","citation":"Henschke N, Maher CG, Refshauge KM, et al. Prevalence of and screening for serious spinal pathology in patients presenting to primary care settings with acute low back pain. Arthritis Rheum. 2009;60(10):3072-3080. doi:10.1002/art.24855","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"415","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":415,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.25,"specificity":1.0},"tp":2.0,"fp":0.0,"fn":6.0,"tn":1164.0,"sample_size":1172.0,"observed_prevalence":0.006825938566552901,"sensitivity":0.25,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9948717948717949,"youden_j":0.25,"lr_positive":null,"lr_negative":0.75,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.05892502921299665,"conditional_entropy_bits_observed":0.046312217390126156,"information_bits_observed":0.012612811822870496,"information_fraction_observed":0.2140484610924653,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fb653917a46e"},{"id":"diagnostics-2024:416:506f5be35aa4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Acute low back pain and significant trauma","test_or_feature":"Acute low back pain and significant trauma","target_condition":"Vertebral fracture","citation":"Henschke N, Maher CG, Refshauge KM, et al. Prevalence of and screening for serious spinal pathology in patients presenting to primary care settings with acute low back pain. Arthritis Rheum. 2009;60(10):3072-3080. doi:10.1002/art.24854","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"416","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":416,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.25,"specificity":0.98},"tp":2.0,"fp":23.0,"fn":6.0,"tn":1141.0,"sample_size":1172.0,"observed_prevalence":0.006825938566552901,"sensitivity":0.25,"specificity":0.9802405498281787,"ppv_observed":0.08,"npv_observed":0.994768962510898,"youden_j":0.23024054982817876,"lr_positive":12.652173913043452,"lr_negative":0.7651183172655566,"diagnostic_odds_ratio":16.536231884057973,"baseline_entropy_bits_observed":0.05892502921299665,"conditional_entropy_bits_observed":0.05474410673677084,"information_bits_observed":0.004180922476225812,"information_fraction_observed":0.07095325249840789,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"35c310e21719"},{"id":"diagnostics-2024:417:8ab0801120eb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Acute low back pain and age 70+","test_or_feature":"Acute low back pain and age 70+","target_condition":"Vertebral fracture","citation":"Henschke N, Maher CG, Refshauge KM, et al. Prevalence of and screening for serious spinal pathology in patients presenting to primary care settings with acute low back pain. Arthritis Rheum. 2009;60(10):3072-3080. doi:10.1002/art.24853","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"417","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":417,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.5,"specificity":0.96},"tp":4.0,"fp":47.0,"fn":4.0,"tn":1117.0,"sample_size":1172.0,"observed_prevalence":0.006825938566552901,"sensitivity":0.5,"specificity":0.9596219931271478,"ppv_observed":0.0784313725490196,"npv_observed":0.9964317573595004,"youden_j":0.4596219931271479,"lr_positive":12.382978723404266,"lr_negative":0.5210384959713518,"diagnostic_odds_ratio":23.76595744680851,"baseline_entropy_bits_observed":0.05892502921299665,"conditional_entropy_bits_observed":0.04992386585897447,"information_bits_observed":0.00900116335402218,"information_fraction_observed":0.15275619671711355,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5cf176913394"},{"id":"diagnostics-2024:418:4d21cf6d4ea7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Malnutrition Universal Screening Tool","test_or_feature":"Malnutrition Universal Screening Tool","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"418","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":418,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":1.0,"specificity":0.98},"tp":10.0,"fp":2.0,"fn":0.0,"tn":88.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":1.0,"specificity":0.9777777777777777,"ppv_observed":0.8333333333333334,"npv_observed":1.0,"youden_j":0.9777777777777779,"lr_positive":44.999999999999936,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.07800269059780249,"information_bits_observed":0.3909929029914787,"information_fraction_observed":0.8336813998595631,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"91e2f90f8950"},{"id":"diagnostics-2024:419:062b037c4b83","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Mid-arm circumference","test_or_feature":"Mid-arm circumference","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"419","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":419,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.7,"specificity":0.99},"tp":7.0,"fp":1.0,"fn":3.0,"tn":89.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":0.7,"specificity":0.9888888888888889,"ppv_observed":0.875,"npv_observed":0.967391304347826,"youden_j":0.6888888888888889,"lr_positive":63.00000000000022,"lr_negative":0.30337078651685395,"diagnostic_odds_ratio":207.66666666666666,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.2342105264466909,"information_bits_observed":0.23478506714259031,"information_fraction_observed":0.5006125224882204,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"276fb2e02d98"},{"id":"diagnostics-2024:420:340045b918cf","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Mini Nutritional Assessment","test_or_feature":"Mini Nutritional Assessment","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"420","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":420,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.8,"specificity":0.9},"tp":8.0,"fp":9.0,"fn":2.0,"tn":81.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":0.8,"specificity":0.9,"ppv_observed":0.47058823529411764,"npv_observed":0.9759036144578314,"youden_j":0.7000000000000002,"lr_positive":8.000000000000002,"lr_negative":0.22222222222222215,"diagnostic_odds_ratio":36.0,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.3055796585641511,"information_bits_observed":0.16341593502513013,"information_fraction_observed":0.34843810316955814,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ce340140aa62"},{"id":"diagnostics-2024:421:88429fa97983","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Body mass index","test_or_feature":"Body mass index","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"421","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":421,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.6,"specificity":0.9},"tp":6.0,"fp":9.0,"fn":4.0,"tn":81.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":0.6,"specificity":0.9,"ppv_observed":0.4,"npv_observed":0.9529411764705882,"youden_j":0.5,"lr_positive":6.000000000000001,"lr_negative":0.4444444444444445,"diagnostic_odds_ratio":13.5,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.3783463825487008,"information_bits_observed":0.09064921104058044,"information_fraction_observed":0.19328371583799075,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b37e576858ab"},{"id":"diagnostics-2024:422:df9e6a398557","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Low cholesterol","test_or_feature":"Low cholesterol","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"422","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":422,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.3,"specificity":0.9},"tp":3.0,"fp":9.0,"fn":7.0,"tn":81.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":0.3,"specificity":0.9,"ppv_observed":0.25,"npv_observed":0.9204545454545454,"youden_j":0.19999999999999996,"lr_positive":3.0000000000000004,"lr_negative":0.7777777777777777,"diagnostic_odds_ratio":3.857142857142857,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.44985985245533927,"information_bits_observed":0.019135741133941953,"information_fraction_observed":0.04080153714770274,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e034599ffab6"},{"id":"diagnostics-2024:423:a0ec5477f0c9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hemoglobin levels","test_or_feature":"Hemoglobin levels","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"423","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":423,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.5,"specificity":0.61},"tp":5.0,"fp":35.0,"fn":5.0,"tn":55.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":0.5,"specificity":0.6111111111111112,"ppv_observed":0.125,"npv_observed":0.9166666666666666,"youden_j":0.11111111111111116,"lr_positive":1.2857142857142858,"lr_negative":0.8181818181818181,"diagnostic_odds_ratio":1.5714285714285714,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.4657158874620188,"information_bits_observed":0.003279706127262416,"information_fraction_observed":0.006993042519146971,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6501be7f8e04"},{"id":"diagnostics-2024:424:71ce89349d7d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Albumin levels","test_or_feature":"Albumin levels","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"424","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":424,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.3,"specificity":0.77},"tp":3.0,"fp":21.0,"fn":7.0,"tn":69.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":0.3,"specificity":0.7666666666666667,"ppv_observed":0.125,"npv_observed":0.9078947368421053,"youden_j":0.06666666666666665,"lr_positive":1.285714285714286,"lr_negative":0.9130434782608694,"diagnostic_odds_ratio":1.4081632653061225,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.4674836568640591,"information_bits_observed":0.001511936725222096,"information_fraction_observed":0.0032237759712219418,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9429a6c28c8b"},{"id":"diagnostics-2024:425:45be11e15ce2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lymphocyte count","test_or_feature":"Lymphocyte count","target_condition":"Malnutrition","citation":"Harris DG, Davies C, Ward H, Haboubi NY. An observational study of screening for malnutrition in elderly people living in sheltered accommodation. J Hum Nutr Diet. 2008;21(1):3-12. doi:10.1111/j.1365-277X.2007.00845.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"425","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":425,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.2,"specificity":0.86},"tp":2.0,"fp":13.0,"fn":8.0,"tn":77.0,"sample_size":100.0,"observed_prevalence":0.1,"sensitivity":0.2,"specificity":0.8555555555555555,"ppv_observed":0.13333333333333333,"npv_observed":0.9058823529411765,"youden_j":0.05555555555555558,"lr_positive":1.3846153846153844,"lr_negative":0.9350649350649352,"diagnostic_odds_ratio":1.4807692307692308,"baseline_entropy_bits_observed":0.4689955935892812,"conditional_entropy_bits_observed":0.4675330853649083,"information_bits_observed":0.0014625082243729381,"information_fraction_observed":0.0031183837212204533,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5b7b0aba2272"},{"id":"diagnostics-2024:426:65689cab6144","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"2-step decision tree algorithm","test_or_feature":"2-step decision tree algorithm","target_condition":"Kawasaki disease","citation":"Hao S, Jin B, Tan Z, et al. A Classification Tool for Differentiation of Kawasaki Disease from Other Febrile Illnesses. J Pediatr. 2016;176:114-120.e8. doi:10.1016/j.jpeds.2016.05.060","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"426","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":426,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":1.0,"specificity":0.89},"tp":769.0,"fp":46.0,"fn":3.0,"tn":376.0,"sample_size":1194.0,"observed_prevalence":0.6465661641541038,"sensitivity":0.9961139896373057,"specificity":0.8909952606635071,"ppv_observed":0.943558282208589,"npv_observed":0.9920844327176781,"youden_j":0.8871092503008127,"lr_positive":9.138263122324847,"lr_negative":0.004361426524087768,"diagnostic_odds_ratio":2095.246376811594,"baseline_entropy_bits_observed":0.9370974308080293,"conditional_entropy_bits_observed":0.23490400405707704,"information_bits_observed":0.7021934267509523,"information_fraction_observed":0.7493280886977497,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f15d1c524d86"},{"id":"diagnostics-2024:427:50043e6e7e33","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal CT","test_or_feature":"Abdominal CT","target_condition":"SBO in children","citation":"Halepota HF, Mateen Khan MA, Shahzad N. Sensitivity and specificity of CT scan in small bowel obstruction among children. J Pak Med Assoc. 2018;68(5):744-746.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"427","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":427,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.97,"specificity":0.82},"tp":74.0,"fp":4.0,"fn":2.0,"tn":18.0,"sample_size":98.0,"observed_prevalence":0.7755102040816326,"sensitivity":0.9736842105263158,"specificity":0.8181818181818182,"ppv_observed":0.9487179487179487,"npv_observed":0.9,"youden_j":0.791866028708134,"lr_positive":5.355263157894738,"lr_negative":0.03216374269005844,"diagnostic_odds_ratio":166.5,"baseline_entropy_bits_observed":0.7682814090975241,"conditional_entropy_bits_observed":0.3279768968010074,"information_bits_observed":0.4403045122965167,"information_fraction_observed":0.5731031716799297,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3076e70112e1"},{"id":"diagnostics-2024:428:a20029832938","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Leukocyte esterase strip test","test_or_feature":"Leukocyte esterase strip test","target_condition":"Septic arthritis","citation":"Haertlé M, Kolbeck L, Macke C, Graulich T, Stauß R, Omar M. Diagnostic Accuracy for Periprosthetic Joint Infection Does Not Improve by a Combined Use of Glucose and Leukocyte Esterase Strip Reading as Diagnostic Parameters. Journal of Clinical Medicine. 2022; 11(11):2979. https://doi.org/10.3390/jcm11112979","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"428","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":428,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.67,"specificity":0.91},"tp":31.0,"fp":9.0,"fn":15.0,"tn":90.0,"sample_size":145.0,"observed_prevalence":0.31724137931034485,"sensitivity":0.6739130434782609,"specificity":0.9090909090909091,"ppv_observed":0.775,"npv_observed":0.8571428571428571,"youden_j":0.5830039525691699,"lr_positive":7.413043478260867,"lr_negative":0.3586956521739131,"diagnostic_odds_ratio":20.666666666666668,"baseline_entropy_bits_observed":0.9013562943838728,"conditional_entropy_bits_observed":0.6406438269769994,"information_bits_observed":0.26071246740687337,"information_fraction_observed":0.2892446294892575,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0205a5b1446f"},{"id":"diagnostics-2024:429:48d636a3cb57","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Glucose strip test","test_or_feature":"Glucose strip test","target_condition":"Septic arthritis","citation":"Haertlé M, Kolbeck L, Macke C, Graulich T, Stauß R, Omar M. Diagnostic Accuracy for Periprosthetic Joint Infection Does Not Improve by a Combined Use of Glucose and Leukocyte Esterase Strip Reading as Diagnostic Parameters. Journal of Clinical Medicine. 2022; 11(11):2979. https://doi.org/10.3390/jcm11112979","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"429","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":429,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.57,"specificity":0.88},"tp":26.0,"fp":12.0,"fn":20.0,"tn":87.0,"sample_size":145.0,"observed_prevalence":0.31724137931034485,"sensitivity":0.5652173913043478,"specificity":0.8787878787878788,"ppv_observed":0.6842105263157895,"npv_observed":0.8130841121495327,"youden_j":0.44400527009222657,"lr_positive":4.663043478260869,"lr_negative":0.494752623688156,"diagnostic_odds_ratio":9.425,"baseline_entropy_bits_observed":0.9013562943838728,"conditional_entropy_bits_observed":0.7486385126818628,"information_bits_observed":0.15271778170201,"information_fraction_observed":0.16943109251419952,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"368f4c8ae4c5"},{"id":"diagnostics-2024:430:c9e6197bd5d5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pivot shift test","test_or_feature":"Pivot shift test","target_condition":"ACL tear","citation":"Gürpınar T, Polat B, Polat AE, Çarkçı E, Öztürkmen Y. Diagnostic Accuracy of Lever Sign Test in Acute, Chronic, and Postreconstructive ACL Injuries. Biomed Res Int. 2019;2019:3639693. Published 2019 Jun 9. doi:10.1155/2019/3639696","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"430","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":430,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.52,"specificity":0.92},"tp":32.0,"fp":1.0,"fn":30.0,"tn":12.0,"sample_size":75.0,"observed_prevalence":0.8266666666666667,"sensitivity":0.5161290322580645,"specificity":0.9230769230769231,"ppv_observed":0.9696969696969697,"npv_observed":0.2857142857142857,"youden_j":0.43920595533498763,"lr_positive":6.709677419354843,"lr_negative":0.5241935483870968,"diagnostic_odds_ratio":12.8,"baseline_entropy_bits_observed":0.6652735227649414,"conditional_entropy_bits_observed":0.5695475975816995,"information_bits_observed":0.09572592518324197,"information_fraction_observed":0.14388957610306768,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7901d8d7202a"},{"id":"diagnostics-2024:431:de63c5c49239","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lever test","test_or_feature":"Lever test","target_condition":"ACL tear","citation":"Gürpınar T, Polat B, Polat AE, Çarkçı E, Öztürkmen Y. Diagnostic Accuracy of Lever Sign Test in Acute, Chronic, and Postreconstructive ACL Injuries. Biomed Res Int. 2019;2019:3639693. Published 2019 Jun 9. doi:10.1155/2019/3639695","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"431","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":431,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.92,"specificity":0.94},"tp":57.0,"fp":1.0,"fn":5.0,"tn":15.0,"sample_size":78.0,"observed_prevalence":0.7948717948717948,"sensitivity":0.9193548387096774,"specificity":0.9375,"ppv_observed":0.9827586206896551,"npv_observed":0.75,"youden_j":0.8568548387096775,"lr_positive":14.709677419354838,"lr_negative":0.08602150537634413,"diagnostic_odds_ratio":171.0,"baseline_entropy_bits_observed":0.7320666900931938,"conditional_entropy_bits_observed":0.3014580692204048,"information_bits_observed":0.430608620872789,"information_fraction_observed":0.5882095534465194,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ccc12ffeb56f"},{"id":"diagnostics-2024:432:f3b882b1f847","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Anterior drawer test","test_or_feature":"Anterior drawer test","target_condition":"ACL tear","citation":"Gürpınar T, Polat B, Polat AE, Çarkçı E, Öztürkmen Y. Diagnostic Accuracy of Lever Sign Test in Acute, Chronic, and Postreconstructive ACL Injuries. Biomed Res Int. 2019;2019:3639693. Published 2019 Jun 9. doi:10.1155/2019/3639694","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"432","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":432,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.78,"specificity":0.69},"tp":49.0,"fp":5.0,"fn":14.0,"tn":11.0,"sample_size":79.0,"observed_prevalence":0.7974683544303798,"sensitivity":0.7777777777777778,"specificity":0.6875,"ppv_observed":0.9074074074074074,"npv_observed":0.44,"youden_j":0.4652777777777777,"lr_positive":2.488888888888889,"lr_negative":0.3232323232323232,"diagnostic_odds_ratio":7.7,"baseline_entropy_bits_observed":0.7269625813353973,"conditional_entropy_bits_observed":0.6173821558391983,"information_bits_observed":0.10958042549619895,"information_fraction_observed":0.15073736710754038,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4c6dc88c2682"},{"id":"diagnostics-2024:433:a49727c69447","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lachman test","test_or_feature":"Lachman test","target_condition":"ACL tear","citation":"Gürpınar T, Polat B, Polat AE, Çarkçı E, Öztürkmen Y. Diagnostic Accuracy of Lever Sign Test in Acute, Chronic, and Postreconstructive ACL Injuries. Biomed Res Int. 2019;2019:3639693. Published 2019 Jun 9. doi:10.1155/2019/3639693","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"433","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":433,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.81,"specificity":0.63},"tp":50.0,"fp":6.0,"fn":12.0,"tn":10.0,"sample_size":78.0,"observed_prevalence":0.7948717948717948,"sensitivity":0.8064516129032258,"specificity":0.625,"ppv_observed":0.8928571428571429,"npv_observed":0.45454545454545453,"youden_j":0.43145161290322576,"lr_positive":2.150537634408602,"lr_negative":0.3096774193548388,"diagnostic_odds_ratio":6.944444444444445,"baseline_entropy_bits_observed":0.7320666900931938,"conditional_entropy_bits_observed":0.6330507153160986,"information_bits_observed":0.09901597477709523,"information_fraction_observed":0.13525540243401904,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"eb0eda120b33"},{"id":"diagnostics-2024:434:51a893517a1b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"QuickVue Rapid Strep Antigen Test","test_or_feature":"QuickVue Rapid Strep Antigen Test","target_condition":"Streptococcal pharyngitis","citation":"Gurol, Y. et al. The sensitivity and the specifity of rapid antigen test in streptococcal upper respiratory tract infections. International Journal of Pediatric Otorhinolaryngology. 2010; 74(6): 591–593. doi: https://doi.org/10.1016/j.ijporl.2010.02.020.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"434","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":434,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.81,"specificity":0.93},"tp":51.0,"fp":28.0,"fn":12.0,"tn":362.0,"sample_size":453.0,"observed_prevalence":0.1390728476821192,"sensitivity":0.8095238095238095,"specificity":0.9282051282051282,"ppv_observed":0.6455696202531646,"npv_observed":0.9679144385026738,"youden_j":0.7377289377289378,"lr_positive":11.275510204081638,"lr_negative":0.20520915548539856,"diagnostic_odds_ratio":54.94642857142857,"baseline_entropy_bits_observed":0.5818055236161184,"conditional_entropy_bits_observed":0.33261327971972154,"information_bits_observed":0.24919224389639683,"information_fraction_observed":0.42830848759836904,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"822972beb1be"},{"id":"diagnostics-2024:435:7142f406837b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care IgA/IgG against deamidated gliadin peptides","test_or_feature":"Point-of-care IgA/IgG against deamidated gliadin peptides","target_condition":"Celiac disease","citation":"Grode L, Møller Jensen T, Parkner T, et al. Diagnostic Accuracy of a Point-of-Care Test for Celiac Disease Antibody Screening among Infertile Patients. Inflamm Intest Dis. 2019;4(3):123-130. doi:10.1159/000501520","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"435","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":435,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.43,"specificity":0.87},"tp":3.0,"fp":81.0,"fn":4.0,"tn":534.0,"sample_size":622.0,"observed_prevalence":0.011254019292604502,"sensitivity":0.42857142857142855,"specificity":0.8682926829268293,"ppv_observed":0.03571428571428571,"npv_observed":0.9925650557620818,"youden_j":0.29686411149825775,"lr_positive":3.2539682539682535,"lr_negative":0.6581059390048154,"diagnostic_odds_ratio":4.944444444444445,"baseline_entropy_bits_observed":0.08899635920815303,"conditional_entropy_bits_observed":0.08473802140178102,"information_bits_observed":0.004258337806372012,"information_fraction_observed":0.04784844957996778,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7352d8d9bcc3"},{"id":"diagnostics-2024:436:7c90682f326f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care Bilistick system","test_or_feature":"Point-of-care Bilistick system","target_condition":"Neonatal hyperbilirubinemia","citation":"Greco C, Iskander IF, El Houchi SZ, et al. Diagnostic Performance Analysis of the Point-of-Care Bilistick System in Identifying Severe Neonatal Hyperbilirubinemia by a Multi-Country Approach. EClinicalMedicine. 2018;1:14-20. Published 2018 Jul 17. doi:10.1016/j.eclinm.2018.06.003","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"436","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":436,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.71,"specificity":0.99},"tp":216.0,"fp":17.0,"fn":90.0,"tn":1135.0,"sample_size":1458.0,"observed_prevalence":0.20987654320987653,"sensitivity":0.7058823529411765,"specificity":0.9852430555555556,"ppv_observed":0.927038626609442,"npv_observed":0.926530612244898,"youden_j":0.691125408496732,"lr_positive":47.83391003460216,"lr_negative":0.2985229334024358,"diagnostic_odds_ratio":160.23529411764707,"baseline_entropy_bits_observed":0.7412466905234424,"conditional_entropy_bits_observed":0.37844204047258895,"information_bits_observed":0.36280465005085344,"information_fraction_observed":0.4894519661121907,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"125b00534745"},{"id":"diagnostics-2024:437:fc0f7ceca123","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"2mg 2 day dexamethasone suppression test","test_or_feature":"2mg 2 day dexamethasone suppression test","target_condition":"Cushing's syndrome","citation":"Görges R, Knappe G, Gerl H, Ventz M, Stahl F. Diagnosis of Cushing's syndrome: re-evaluation of midnight plasma cortisol vs urinary free cortisol and low-dose dexamethasone suppression test in a large patient group. J Endocrinol Invest. 1999;22(4):241-249. doi:10.1007/BF03343555","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"437","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":437,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.78,"specificity":0.95},"tp":106.0,"fp":10.0,"fn":30.0,"tn":177.0,"sample_size":323.0,"observed_prevalence":0.42105263157894735,"sensitivity":0.7794117647058824,"specificity":0.946524064171123,"ppv_observed":0.9137931034482759,"npv_observed":0.855072463768116,"youden_j":0.7259358288770055,"lr_positive":14.575000000000003,"lr_negative":0.2330508474576271,"diagnostic_odds_ratio":62.54,"baseline_entropy_bits_observed":0.9819407868640977,"conditional_entropy_bits_observed":0.5347549420174608,"information_bits_observed":0.4471858448466369,"information_fraction_observed":0.4554101946154603,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9f35c939037d"},{"id":"diagnostics-2024:438:1f5563c4b149","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"1mg overnight dexamethasone suppression test","test_or_feature":"1mg overnight dexamethasone suppression test","target_condition":"Cushing's syndrome","citation":"Görges R, Knappe G, Gerl H, Ventz M, Stahl F. Diagnosis of Cushing's syndrome: re-evaluation of midnight plasma cortisol vs urinary free cortisol and low-dose dexamethasone suppression test in a large patient group. J Endocrinol Invest. 1999;22(4):241-249. doi:10.1007/BF03343554","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"438","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":438,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.96,"specificity":0.97},"tp":237.0,"fp":147.0,"fn":10.0,"tn":4911.0,"sample_size":5305.0,"observed_prevalence":0.04655984919886899,"sensitivity":0.9595141700404858,"specificity":0.9709371293001187,"ppv_observed":0.6171875,"npv_observed":0.9979678927047348,"youden_j":0.9304512993406044,"lr_positive":33.01512021812778,"lr_negative":0.04169768436880939,"diagnostic_odds_ratio":791.7734693877551,"baseline_entropy_bits_observed":0.27159967648561906,"conditional_entropy_bits_observed":0.08906352018349997,"information_bits_observed":0.18253615630211908,"information_fraction_observed":0.6720779592378645,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d228a8432a92"},{"id":"diagnostics-2024:439:19bba35eee79","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Midnight salivary cortisol","test_or_feature":"Midnight salivary cortisol","target_condition":"Cushing's syndrome","citation":"Görges R, Knappe G, Gerl H, Ventz M, Stahl F. Diagnosis of Cushing's syndrome: re-evaluation of midnight plasma cortisol vs urinary free cortisol and low-dose dexamethasone suppression test in a large patient group. J Endocrinol Invest. 1999;22(4):241-249. doi:10.1007/BF03343553","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"439","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":439,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.92,"specificity":0.91},"tp":180.0,"fp":10.0,"fn":15.0,"tn":98.0,"sample_size":303.0,"observed_prevalence":0.6435643564356436,"sensitivity":0.9230769230769231,"specificity":0.9074074074074074,"ppv_observed":0.9473684210526315,"npv_observed":0.8672566371681416,"youden_j":0.8304843304843306,"lr_positive":9.969230769230773,"lr_negative":0.08477237048665615,"diagnostic_odds_ratio":117.6,"baseline_entropy_bits_observed":0.9396846718728562,"conditional_entropy_bits_observed":0.39721130821836004,"information_bits_observed":0.5424733636544962,"information_fraction_observed":0.577292979115334,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fbf789001f36"},{"id":"diagnostics-2024:440:9b4546e4bdd0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Midnight serum cortisol","test_or_feature":"Midnight serum cortisol","target_condition":"Cushing's syndrome","citation":"Görges R, Knappe G, Gerl H, Ventz M, Stahl F. Diagnosis of Cushing's syndrome: re-evaluation of midnight plasma cortisol vs urinary free cortisol and low-dose dexamethasone suppression test in a large patient group. J Endocrinol Invest. 1999;22(4):241-249. doi:10.1007/BF03343552","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"440","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":440,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.95,"specificity":0.88},"tp":483.0,"fp":515.0,"fn":28.0,"tn":3709.0,"sample_size":4735.0,"observed_prevalence":0.10791974656810982,"sensitivity":0.9452054794520548,"specificity":0.8780776515151515,"ppv_observed":0.48396793587174347,"npv_observed":0.9925073588439925,"youden_j":0.8232831309672064,"lr_positive":7.7525202819523855,"lr_negative":0.06240281876368847,"diagnostic_odds_ratio":124.23349514563107,"baseline_entropy_bits_observed":0.4936092225143046,"conditional_entropy_bits_observed":0.2608642361837645,"information_bits_observed":0.23274498633054014,"information_fraction_observed":0.4715166891432935,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"39f878c99674"},{"id":"diagnostics-2024:441:1607c0d56804","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urinary free cortisol","test_or_feature":"Urinary free cortisol","target_condition":"Cushing's syndrome","citation":"Görges R, Knappe G, Gerl H, Ventz M, Stahl F. Diagnosis of Cushing's syndrome: re-evaluation of midnight plasma cortisol vs urinary free cortisol and low-dose dexamethasone suppression test in a large patient group. J Endocrinol Invest. 1999;22(4):241-249. doi:10.1007/BF03343551","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"441","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":441,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1999,"source_reported":{"sensitivity":0.64,"specificity":0.91},"tp":416.0,"fp":406.0,"fn":230.0,"tn":4174.0,"sample_size":5226.0,"observed_prevalence":0.12361270570225794,"sensitivity":0.6439628482972136,"specificity":0.911353711790393,"ppv_observed":0.5060827250608273,"npv_observed":0.9477747502270663,"youden_j":0.5553165600876067,"lr_positive":7.264408485717338,"lr_negative":0.3906684606609395,"diagnostic_odds_ratio":18.594816877275647,"baseline_entropy_bits_observed":0.5396570822629219,"conditional_entropy_bits_observed":0.4065265042069634,"information_bits_observed":0.13313057805595846,"information_fraction_observed":0.24669476679099156,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6c7db919f8d4"},{"id":"diagnostics-2024:442:5f31822fb6a4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"US","test_or_feature":"US","target_condition":"Sialolithiasis","citation":"Goncalves M, Mantsopoulos K, Schapher M, Iro H, Koch M. Ultrasound Supplemented by Sialendoscopy: Diagnostic Value in Sialolithiasis. Otolaryngology–Head and Neck Surgery. 2018;159(3):449-455. doi:10.1177/0194599818775946","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"442","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":442,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.95,"specificity":0.94},"tp":1333.0,"fp":51.0,"fn":68.0,"tn":825.0,"sample_size":2277.0,"observed_prevalence":0.6152832674571805,"sensitivity":0.9514632405424697,"specificity":0.9417808219178082,"ppv_observed":0.963150289017341,"npv_observed":0.9238521836506159,"youden_j":0.893244062460278,"lr_positive":16.34278036696477,"lr_negative":0.0515372136785413,"diagnostic_odds_ratio":317.10640138408303,"baseline_entropy_bits_observed":0.9613052946020577,"conditional_entropy_bits_observed":0.29072038237085485,"information_bits_observed":0.6705849122312029,"information_fraction_observed":0.6975774668013229,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b9c8c0d1cad0"},{"id":"diagnostics-2024:443:c0b33e5a7f05","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ottawa ankle rule","test_or_feature":"Ottawa ankle rule","target_condition":"Ankle fracture","citation":"Gomes YE, Chau M, Banwell HA, Causby RS. Diagnostic accuracy of the Ottawa ankle rule to exclude fractures in acute ankle injuries in adults: a systematic review and meta-analysis. BMC Musculoskelet Disord. 2022;23(1):885. Published 2022 Sep 23. doi:10.1186/s12891-022-05831-7","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"443","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":443,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.91,"specificity":0.24},"tp":1270.0,"fp":5191.0,"fn":130.0,"tn":1682.0,"sample_size":8273.0,"observed_prevalence":0.16922519037833916,"sensitivity":0.9071428571428571,"specificity":0.24472573839662448,"ppv_observed":0.1965639993809008,"npv_observed":0.9282560706401766,"youden_j":0.15186859553948162,"lr_positive":1.2010774142059057,"lr_negative":0.37943349753694583,"diagnostic_odds_ratio":3.1654490760636014,"baseline_entropy_bits_observed":0.6559292696000908,"conditional_entropy_bits_observed":0.639963445776728,"information_bits_observed":0.015965823823362757,"information_fraction_observed":0.024340770511882867,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e71d3f462d98"},{"id":"diagnostics-2024:444:c67bc3220550","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ophthalmoscopy","test_or_feature":"Ophthalmoscopy","target_condition":"Increased intracranial pressure","citation":"Golshani K, Ebrahim Zadeh M, Farajzadegan Z, Khorvash F. Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure. Emerg (Tehran). 2015;3(2):54-58.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"444","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":444,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":1.0,"specificity":0.35},"tp":38.0,"fp":60.0,"fn":0.0,"tn":33.0,"sample_size":131.0,"observed_prevalence":0.2900763358778626,"sensitivity":1.0,"specificity":0.3548387096774194,"ppv_observed":0.3877551020408163,"npv_observed":1.0,"youden_j":0.3548387096774195,"lr_positive":1.55,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8688198340267391,"conditional_entropy_bits_observed":0.7206632326406339,"information_bits_observed":0.1481566013861052,"information_fraction_observed":0.17052626515147615,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7bec239540d3"},{"id":"diagnostics-2024:445:f0239804201a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Optic ultrasonography","test_or_feature":"Optic ultrasonography","target_condition":"Increased intracranial pressure","citation":"Golshani K, Ebrahim Zadeh M, Farajzadegan Z, Khorvash F. Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure. Emerg (Tehran). 2015;3(2):54-58.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"445","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":445,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":1.0,"specificity":0.31},"tp":38.0,"fp":64.0,"fn":0.0,"tn":29.0,"sample_size":131.0,"observed_prevalence":0.2900763358778626,"sensitivity":1.0,"specificity":0.3118279569892473,"ppv_observed":0.37254901960784315,"npv_observed":1.0,"youden_j":0.31182795698924726,"lr_positive":1.4531249999999998,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8688198340267391,"conditional_entropy_bits_observed":0.7417262547346282,"information_bits_observed":0.12709357929211096,"information_fraction_observed":0.14628300864526475,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"05890a7b7617"},{"id":"diagnostics-2024:446:249ff19db33a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"TEE","test_or_feature":"TEE","target_condition":"Traumatic aortic injury","citation":"Goarin JP, Cluzel P, Gosgnach M, Lamine K, Coriat P, Riou B. Evaluation of transesophageal echocardiography for diagnosis of traumatic aortic injury. Anesthesiology. 2000;93(6):1373-1377. doi:10.1097/00000542-200012000-00006","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"446","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":446,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.98,"specificity":1.0},"tp":41.0,"fp":0.0,"fn":1.0,"tn":167.0,"sample_size":209.0,"observed_prevalence":0.20095693779904306,"sensitivity":0.9761904761904762,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9940476190476191,"youden_j":0.9761904761904763,"lr_positive":null,"lr_negative":0.023809523809523836,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.7238378469140183,"conditional_entropy_bits_observed":0.042252201835717706,"information_bits_observed":0.6815856450783007,"information_fraction_observed":0.9416275316138082,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0b2c8315b7ad"},{"id":"diagnostics-2024:447:f8951ac85582","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CT angiography","test_or_feature":"CT angiography","target_condition":"Traumatic aortic injury","citation":"Goarin JP, Cluzel P, Gosgnach M, Lamine K, Coriat P, Riou B. Evaluation of transesophageal echocardiography for diagnosis of traumatic aortic injury. Anesthesiology. 2000;93(6):1373-1377. doi:10.1097/00000542-200012000-00005","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"447","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":447,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.83,"specificity":1.0},"tp":35.0,"fp":0.0,"fn":7.0,"tn":167.0,"sample_size":209.0,"observed_prevalence":0.20095693779904306,"sensitivity":0.8333333333333334,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9597701149425287,"youden_j":0.8333333333333335,"lr_positive":null,"lr_negative":0.16666666666666663,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.7238378469140183,"conditional_entropy_bits_observed":0.20259362191439606,"information_bits_observed":0.5212442249996223,"information_fraction_observed":0.7201118692838104,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8eb1ca04afdf"},{"id":"diagnostics-2024:448:0b7b3ddee820","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Triggering receptor expressed on myeloid cells-1","test_or_feature":"Triggering receptor expressed on myeloid cells-1","target_condition":"Sepsis","citation":"Gibot S, Kolopp-Sarda MN, Béné MC, et al. Plasma level of a triggering receptor expressed on myeloid cells-1: its diagnostic accuracy in patients with suspected sepsis [published correction appears in Ann Intern Med. 2005 Apr 5;142(7):592]. Ann Intern Med. 2004;141(1):9-15. doi:10.7326/0003-4819-141-1-200407060-00009","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"448","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":448,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.97,"specificity":0.89},"tp":28.0,"fp":5.0,"fn":1.0,"tn":42.0,"sample_size":76.0,"observed_prevalence":0.3815789473684211,"sensitivity":0.9655172413793104,"specificity":0.8936170212765957,"ppv_observed":0.8484848484848485,"npv_observed":0.9767441860465116,"youden_j":0.859134262655906,"lr_positive":9.075862068965513,"lr_negative":0.03858784893267647,"diagnostic_odds_ratio":235.2,"baseline_entropy_bits_observed":0.959149554396894,"conditional_entropy_bits_observed":0.3565984255560726,"information_bits_observed":0.6025511288408214,"information_fraction_observed":0.6282139485741627,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"177cbab9ad82","condition_context_id":"condition:sepsis"},{"id":"diagnostics-2024:449:8de0ef584267","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Karlsson's ratio","test_or_feature":"Karlsson's ratio","target_condition":"Myometrial invasion of endometrial cancer","citation":"Frühauf F, Zikan M, Semeradova I, et al. The Diagnostic Accuracy of Ultrasound in Assessment of Myometrial Invasion in Endometrial Cancer: Subjective Assessment versus Objective Techniques. Biomed Res Int. 2017;2017:1318203. doi:10.1155/2017/1318205","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"449","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":449,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.56,"specificity":0.76},"tp":49.0,"fp":29.0,"fn":38.0,"tn":94.0,"sample_size":210.0,"observed_prevalence":0.4142857142857143,"sensitivity":0.5632183908045977,"specificity":0.7642276422764228,"ppv_observed":0.6282051282051282,"npv_observed":0.7121212121212122,"youden_j":0.3274460330810205,"lr_positive":2.3888228299643286,"lr_negative":0.5715333822450477,"diagnostic_odds_ratio":4.1796733212341195,"baseline_entropy_bits_observed":0.9786961448300948,"conditional_entropy_bits_observed":0.8979360382746298,"information_bits_observed":0.08076010655546506,"information_fraction_observed":0.08251805934055795,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"da713a2ce6dd"},{"id":"diagnostics-2024:450:45de57bd1134","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Gordon's ratio","test_or_feature":"Gordon's ratio","target_condition":"Myometrial invasion of endometrial cancer","citation":"Frühauf F, Zikan M, Semeradova I, et al. The Diagnostic Accuracy of Ultrasound in Assessment of Myometrial Invasion in Endometrial Cancer: Subjective Assessment versus Objective Techniques. Biomed Res Int. 2017;2017:1318203. doi:10.1155/2017/1318204","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"450","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":450,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.7,"specificity":0.66},"tp":61.0,"fp":42.0,"fn":26.0,"tn":81.0,"sample_size":210.0,"observed_prevalence":0.4142857142857143,"sensitivity":0.7011494252873564,"specificity":0.6585365853658537,"ppv_observed":0.5922330097087378,"npv_observed":0.7570093457943925,"youden_j":0.35968601065321004,"lr_positive":2.0533661740558293,"lr_negative":0.45381013197105147,"diagnostic_odds_ratio":4.524725274725275,"baseline_entropy_bits_observed":0.9786961448300948,"conditional_entropy_bits_observed":0.8859758551972725,"information_bits_observed":0.0927202896328223,"information_fraction_observed":0.09473858676424937,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"db6a4e464391"},{"id":"diagnostics-2024:451:482aebdf8c65","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Subjective ultrasound assessment","test_or_feature":"Subjective ultrasound assessment","target_condition":"Myometrial invasion of endometrial cancer","citation":"Frühauf F, Zikan M, Semeradova I, et al. The Diagnostic Accuracy of Ultrasound in Assessment of Myometrial Invasion in Endometrial Cancer: Subjective Assessment versus Objective Techniques. Biomed Res Int. 2017;2017:1318203. doi:10.1155/2017/1318203","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"451","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":451,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.79,"specificity":0.73},"tp":69.0,"fp":33.0,"fn":18.0,"tn":90.0,"sample_size":210.0,"observed_prevalence":0.4142857142857143,"sensitivity":0.7931034482758621,"specificity":0.7317073170731707,"ppv_observed":0.6764705882352942,"npv_observed":0.8333333333333334,"youden_j":0.5248107653490328,"lr_positive":2.956112852664577,"lr_negative":0.2827586206896551,"diagnostic_odds_ratio":10.454545454545455,"baseline_entropy_bits_observed":0.9786961448300948,"conditional_entropy_bits_observed":0.7754124426790103,"information_bits_observed":0.2032837021510845,"information_fraction_observed":0.2077086981745241,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7d7c17f4d789"},{"id":"diagnostics-2024:452:9e041e46efe4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serological testing","test_or_feature":"Serological testing","target_condition":"Neurocysticercosis","citation":"Foyaca-Sibat H, Cowan LD, Carabin H, et al. Accuracy of Serological Testing for the Diagnosis of Prevalent Neurocysticercosis in Outpatients with Epilepsy, Eastern Cape Province, South Africa. Lyke KE, ed. PLoS Neglected Tropical Diseases. 2009;3(12):e562. doi:10.1371/journal.pntd.0000562","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"452","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":452,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.55,"specificity":0.69},"tp":18.0,"fp":12.0,"fn":15.0,"tn":27.0,"sample_size":72.0,"observed_prevalence":0.4583333333333333,"sensitivity":0.5454545454545454,"specificity":0.6923076923076923,"ppv_observed":0.6,"npv_observed":0.6428571428571429,"youden_j":0.2377622377622377,"lr_positive":1.7727272727272725,"lr_negative":0.6565656565656567,"diagnostic_odds_ratio":2.7,"baseline_entropy_bits_observed":0.99498482818597,"conditional_entropy_bits_observed":0.9530628902473135,"information_bits_observed":0.041921937938656506,"information_fraction_observed":0.042133243393356536,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0927c56a5174"},{"id":"diagnostics-2024:453:b8a25750092e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"DSM5 criteria","test_or_feature":"DSM5 criteria","target_condition":"Borderline personality disorder","citation":"Fowler JC, Carlson M, Orme WH, et al. Diagnostic accuracy of DSM-5 borderline personality disorder criteria: Toward an optimized criteria set. J Affect Disord. 2021;279:203-207. doi:10.1016/j.jad.2020.09.138","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"453","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":453,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.99,"specificity":0.9},"tp":348.0,"fp":127.0,"fn":4.0,"tn":1144.0,"sample_size":1623.0,"observed_prevalence":0.21688231669747382,"sensitivity":0.9886363636363636,"specificity":0.9000786782061369,"ppv_observed":0.7326315789473684,"npv_observed":0.9965156794425087,"youden_j":0.8887150418425005,"lr_positive":9.89414817465998,"lr_negative":0.012625158931977104,"diagnostic_odds_ratio":783.6850393700787,"baseline_entropy_bits_observed":0.7544337059086421,"conditional_entropy_bits_observed":0.26882951928680654,"information_bits_observed":0.4856041866218356,"information_fraction_observed":0.6436671410869329,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"327301a927e0"},{"id":"diagnostics-2024:454:ab04d7eb938c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pre-evacuation US","test_or_feature":"Pre-evacuation US","target_condition":"Hydatidiform mole","citation":"Fowler DJ, Lindsay I, Seckl MJ, Sebire NJ. Routine pre-evacuation ultrasound diagnosis of hydatidiform mole: experience of more than 1000 cases from a regional referral center. Ultrasound Obstet Gynecol. 2006;27(1):56-60. doi:10.1002/uog.2592","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"454","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":454,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.44,"specificity":0.74},"tp":166.0,"fp":176.0,"fn":212.0,"tn":500.0,"sample_size":1054.0,"observed_prevalence":0.3586337760910816,"sensitivity":0.43915343915343913,"specificity":0.7396449704142012,"ppv_observed":0.4853801169590643,"npv_observed":0.702247191011236,"youden_j":0.17879840956764026,"lr_positive":1.6867484367484367,"lr_negative":0.7582645502645504,"diagnostic_odds_ratio":2.2244854202401374,"baseline_entropy_bits_observed":0.9415432737602487,"conditional_entropy_bits_observed":0.9177419105852531,"information_bits_observed":0.023801363174995593,"information_fraction_observed":0.025279096392394056,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8755bb8ece11"},{"id":"diagnostics-2024:455:d092df5effea","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Diagnostic algorithm by Fillippopulos et al.","test_or_feature":"Diagnostic algorithm by Fillippopulos et al.","target_condition":"Benign paroxysmal positional vertigo","citation":"Filippopulos, FM, Strobl, R, Belanovic, B, et al. Validation of a comprehensive diagnostic algorithm for patients with acute vertigo and dizziness. Eur J Neurol. 2022; 29: 3092- 3101. doi: 10.1111/ene.15448","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"455","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":455,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.77,"specificity":0.97},"tp":23.0,"fp":2.0,"fn":7.0,"tn":57.0,"sample_size":89.0,"observed_prevalence":0.33707865168539325,"sensitivity":0.7666666666666667,"specificity":0.9661016949152542,"ppv_observed":0.92,"npv_observed":0.890625,"youden_j":0.7327683615819209,"lr_positive":22.616666666666653,"lr_negative":0.24152046783625727,"diagnostic_odds_ratio":93.64285714285714,"baseline_entropy_bits_observed":0.9219957030944405,"conditional_entropy_bits_observed":0.4711040954299248,"information_bits_observed":0.45089160766451564,"information_fraction_observed":0.4890387299541792,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e06bf423496c","condition_context_id":"condition:bppv"},{"id":"diagnostics-2024:456:c6590294641d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Chest CT","test_or_feature":"Chest CT","target_condition":"Aortic regurgitation","citation":"Feuchtner G et al. Diagnostic Accuracy Of 64-slice Computed Tomography For Diagnosis Of Aortic Regurgitation In Patients Referred To Coronary CT Angiography. Circulation. 2007;116:II_410.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"456","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":456,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2007,"source_reported":{"sensitivity":0.73,"specificity":0.97},"tp":33.0,"fp":1.0,"fn":12.0,"tn":35.0,"sample_size":81.0,"observed_prevalence":0.5555555555555556,"sensitivity":0.7333333333333333,"specificity":0.9722222222222222,"ppv_observed":0.9705882352941176,"npv_observed":0.7446808510638298,"youden_j":0.7055555555555555,"lr_positive":26.399999999999988,"lr_negative":0.27428571428571435,"diagnostic_odds_ratio":96.25,"baseline_entropy_bits_observed":0.9910760598382222,"conditional_entropy_bits_observed":0.5559253221086893,"information_bits_observed":0.43515073772953294,"information_fraction_observed":0.4390689628811784,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e887f5960716"},{"id":"diagnostics-2024:457:fcf9fb764d22","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urea breath test","test_or_feature":"Urea breath test","target_condition":"H.pylori infection","citation":"Ferwana M, Abdulmajeed I, Alhajiahmed A, et al. Accuracy of urea breath test in Helicobacter pylori infection: meta-analysis. World J Gastroenterol. 2015;21(4):1305-1314. doi:10.3748/wjg.v21.i4.1329","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"457","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":457,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.96,"specificity":0.93},"tp":2432.0,"fp":112.0,"fn":100.0,"tn":1471.0,"sample_size":4115.0,"observed_prevalence":0.6153098420413122,"sensitivity":0.9605055292259084,"specificity":0.9292482627921668,"ppv_observed":0.9559748427672956,"npv_observed":0.936346276257161,"youden_j":0.8897537920180751,"lr_positive":13.575716542541187,"lr_negative":0.042501527692309346,"diagnostic_odds_ratio":319.41714285714284,"baseline_entropy_bits_observed":0.961287289386821,"conditional_entropy_bits_observed":0.291501606513245,"information_bits_observed":0.669785682873576,"information_fraction_observed":0.6967591169345577,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"803d3f773b47"},{"id":"diagnostics-2024:458:ddb6a4a7688a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Elevated GGT","test_or_feature":"Elevated GGT","target_condition":"Liver disease","citation":"Ferraris R, Colombatti G, Fiorentini MT, Carosso R, Arossa W, De La Pierre M. Diagnostic value of serum bile acids and routine liver function tests in hepatobiliary diseases. Sensitivity, specificity, and predictive value. Dig Dis Sci. 1983;28(2):129-136. doi:10.1007/BF01315146","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"458","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":458,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1983,"source_reported":{"sensitivity":0.75,"specificity":0.85},"tp":258.0,"fp":35.0,"fn":86.0,"tn":200.0,"sample_size":579.0,"observed_prevalence":0.5941278065630398,"sensitivity":0.75,"specificity":0.851063829787234,"ppv_observed":0.8805460750853242,"npv_observed":0.6993006993006993,"youden_j":0.6010638297872339,"lr_positive":5.035714285714286,"lr_negative":0.29375,"diagnostic_odds_ratio":17.142857142857142,"baseline_entropy_bits_observed":0.9742821320129038,"conditional_entropy_bits_observed":0.7028245532171662,"information_bits_observed":0.2714575787957376,"information_fraction_observed":0.27862317277121357,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d40b51ed602f"},{"id":"diagnostics-2024:459:49e3d1c00db2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Elevated ALT","test_or_feature":"Elevated ALT","target_condition":"Liver disease","citation":"Ferraris R, Colombatti G, Fiorentini MT, Carosso R, Arossa W, De La Pierre M. Diagnostic value of serum bile acids and routine liver function tests in hepatobiliary diseases. Sensitivity, specificity, and predictive value. Dig Dis Sci. 1983;28(2):129-136. doi:10.1007/BF01315145","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"459","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":459,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1983,"source_reported":{"sensitivity":0.56,"specificity":0.9},"tp":193.0,"fp":24.0,"fn":151.0,"tn":212.0,"sample_size":580.0,"observed_prevalence":0.593103448275862,"sensitivity":0.561046511627907,"specificity":0.8983050847457628,"ppv_observed":0.8894009216589862,"npv_observed":0.5840220385674931,"youden_j":0.45935159637366985,"lr_positive":5.516957364341088,"lr_negative":0.48864633611232994,"diagnostic_odds_ratio":11.29028697571744,"baseline_entropy_bits_observed":0.9748421326581824,"conditional_entropy_bits_observed":0.8007651726161674,"information_bits_observed":0.174076960042015,"information_fraction_observed":0.17856938493963634,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a15f1a0d0427"},{"id":"diagnostics-2024:460:52e0506222f0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Elevated total bilirubin","test_or_feature":"Elevated total bilirubin","target_condition":"Liver disease","citation":"Ferraris R, Colombatti G, Fiorentini MT, Carosso R, Arossa W, De La Pierre M. Diagnostic value of serum bile acids and routine liver function tests in hepatobiliary diseases. Sensitivity, specificity, and predictive value. Dig Dis Sci. 1983;28(2):129-136. doi:10.1007/BF01315144","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"460","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":460,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1983,"source_reported":{"sensitivity":0.56,"specificity":0.91},"tp":193.0,"fp":21.0,"fn":151.0,"tn":214.0,"sample_size":579.0,"observed_prevalence":0.5941278065630398,"sensitivity":0.561046511627907,"specificity":0.9106382978723404,"ppv_observed":0.9018691588785047,"npv_observed":0.5863013698630137,"youden_j":0.4716848095002475,"lr_positive":6.278377630121815,"lr_negative":0.48202836339926103,"diagnostic_odds_ratio":13.024913276568906,"baseline_entropy_bits_observed":0.9742821320129038,"conditional_entropy_bits_observed":0.7879235387148757,"information_bits_observed":0.18635859329802806,"information_fraction_observed":0.19127785184051785,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a5ed40a0b7dd"},{"id":"diagnostics-2024:461:f92136fd6d64","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Elevated AST","test_or_feature":"Elevated AST","target_condition":"Liver disease","citation":"Ferraris R, Colombatti G, Fiorentini MT, Carosso R, Arossa W, De La Pierre M. Diagnostic value of serum bile acids and routine liver function tests in hepatobiliary diseases. Sensitivity, specificity, and predictive value. Dig Dis Sci. 1983;28(2):129-136. doi:10.1007/BF01315143","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"461","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":461,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1983,"source_reported":{"sensitivity":0.74,"specificity":0.92},"tp":255.0,"fp":19.0,"fn":89.0,"tn":216.0,"sample_size":579.0,"observed_prevalence":0.5941278065630398,"sensitivity":0.7412790697674418,"specificity":0.9191489361702128,"ppv_observed":0.9306569343065694,"npv_observed":0.7081967213114754,"youden_j":0.6604280059376546,"lr_positive":9.16845165238678,"lr_negative":0.281478789836348,"diagnostic_odds_ratio":32.57244234180958,"baseline_entropy_bits_observed":0.9742821320129038,"conditional_entropy_bits_observed":0.630841144474533,"information_bits_observed":0.3434409875383708,"information_fraction_observed":0.352506708532988,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"86b6c8f05612"},{"id":"diagnostics-2024:462:160395627064","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum bile acids","test_or_feature":"Serum bile acids","target_condition":"Liver disease","citation":"Ferraris R, Colombatti G, Fiorentini MT, Carosso R, Arossa W, De La Pierre M. Diagnostic value of serum bile acids and routine liver function tests in hepatobiliary diseases. Sensitivity, specificity, and predictive value. Dig Dis Sci. 1983;28(2):129-136. doi:10.1007/BF01315142","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"462","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":462,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1983,"source_reported":{"sensitivity":0.78,"specificity":0.93},"tp":268.0,"fp":16.0,"fn":76.0,"tn":219.0,"sample_size":579.0,"observed_prevalence":0.5941278065630398,"sensitivity":0.7790697674418605,"specificity":0.9319148936170213,"ppv_observed":0.9436619718309859,"npv_observed":0.7423728813559322,"youden_j":0.7109846610588817,"lr_positive":11.442587209302328,"lr_negative":0.23707125411489852,"diagnostic_odds_ratio":48.266447368421055,"baseline_entropy_bits_observed":0.9742821320129038,"conditional_entropy_bits_observed":0.572787408248346,"information_bits_observed":0.40149472376455786,"information_fraction_observed":0.4120928738937812,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7854798c8664"},{"id":"diagnostics-2024:463:1b822ba5e7a5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Appendicitis","citation":"Fatima SR, Zaheer F, Moosa FA, Arqam SM, Mussab RM, Choudhry MS. Combined Diagnostic Accuracy of Total Leukocyte Count, Neutrophil Count, and Ultrasonography for the Diagnosis of Acute Appendicitis. Cureus. 2021;13(2):e13086. Published 2021 Feb 2. doi:10.7759/cureus.13088","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"463","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":463,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.89,"specificity":0.82},"tp":127.0,"fp":5.0,"fn":15.0,"tn":23.0,"sample_size":170.0,"observed_prevalence":0.8352941176470589,"sensitivity":0.8943661971830986,"specificity":0.8214285714285714,"ppv_observed":0.9621212121212122,"npv_observed":0.6052631578947368,"youden_j":0.7157947686116701,"lr_positive":5.008450704225352,"lr_negative":0.12859767299448863,"diagnostic_odds_ratio":38.946666666666665,"baseline_entropy_bits_observed":0.6454495903301855,"conditional_entropy_bits_observed":0.3968434685190067,"information_bits_observed":0.24860612181117875,"information_fraction_observed":0.3851673709855515,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c1e56251a5cc","condition_context_id":"condition:appendicitis"},{"id":"diagnostics-2024:464:8ad3803c7447","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Neutrophils","test_or_feature":"Neutrophils","target_condition":"Appendicitis","citation":"Fatima SR, Zaheer F, Moosa FA, Arqam SM, Mussab RM, Choudhry MS. Combined Diagnostic Accuracy of Total Leukocyte Count, Neutrophil Count, and Ultrasonography for the Diagnosis of Acute Appendicitis. Cureus. 2021;13(2):e13086. Published 2021 Feb 2. doi:10.7759/cureus.13087","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"464","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":464,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.88,"specificity":0.93},"tp":130.0,"fp":2.0,"fn":18.0,"tn":27.0,"sample_size":177.0,"observed_prevalence":0.8361581920903954,"sensitivity":0.8783783783783784,"specificity":0.9310344827586207,"ppv_observed":0.9848484848484849,"npv_observed":0.6,"youden_j":0.8094128611369991,"lr_positive":12.736486486486482,"lr_negative":0.1306306306306306,"diagnostic_odds_ratio":97.5,"baseline_entropy_bits_observed":0.6434216688864769,"conditional_entropy_bits_observed":0.33132759780834375,"information_bits_observed":0.31209407107813314,"information_fraction_observed":0.4850537154246789,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5ce726e02df7","condition_context_id":"condition:appendicitis"},{"id":"diagnostics-2024:465:01a89877d052","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Total leukocyte count","test_or_feature":"Total leukocyte count","target_condition":"Appendicitis","citation":"Fatima SR, Zaheer F, Moosa FA, Arqam SM, Mussab RM, Choudhry MS. Combined Diagnostic Accuracy of Total Leukocyte Count, Neutrophil Count, and Ultrasonography for the Diagnosis of Acute Appendicitis. Cureus. 2021;13(2):e13086. Published 2021 Feb 2. doi:10.7759/cureus.13086","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"465","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":465,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.83,"specificity":0.83},"tp":123.0,"fp":5.0,"fn":25.0,"tn":24.0,"sample_size":177.0,"observed_prevalence":0.8361581920903954,"sensitivity":0.831081081081081,"specificity":0.8275862068965517,"ppv_observed":0.9609375,"npv_observed":0.4897959183673469,"youden_j":0.6586672879776327,"lr_positive":4.82027027027027,"lr_negative":0.20411036036036043,"diagnostic_odds_ratio":23.616,"baseline_entropy_bits_observed":0.6434216688864769,"conditional_entropy_bits_observed":0.4488494518011639,"information_bits_observed":0.19457221708531297,"information_fraction_observed":0.30240233814637446,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8c0e559f791f","condition_context_id":"condition:appendicitis"},{"id":"diagnostics-2024:466:0d567748e830","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Gallbladder US (wall)","test_or_feature":"Gallbladder US (wall)","target_condition":"Biliary atresia","citation":"Farrant P, Meire HB, Mieli-Vergani G. Ultrasound features of the gall bladder in infants presenting with conjugated hyperbilirubinaemia. Br J Radiol. 2000;73(875):1154-1158. doi:10.1259/bjr.73.875.11144792","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"466","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":466,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.87,"specificity":0.94},"tp":52.0,"fp":17.0,"fn":8.0,"tn":254.0,"sample_size":331.0,"observed_prevalence":0.18126888217522658,"sensitivity":0.8666666666666667,"specificity":0.9372693726937269,"ppv_observed":0.7536231884057971,"npv_observed":0.9694656488549618,"youden_j":0.8039360393603936,"lr_positive":13.815686274509796,"lr_negative":0.142257217847769,"diagnostic_odds_ratio":97.11764705882354,"baseline_entropy_bits_observed":0.682845032355827,"conditional_entropy_bits_observed":0.3238953771473805,"information_bits_observed":0.35894965520844657,"information_fraction_observed":0.5256678136327128,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a84cc108c16d"},{"id":"diagnostics-2024:467:edf30f01b3cd","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Gallbladder US (shape)","test_or_feature":"Gallbladder US (shape)","target_condition":"Biliary atresia","citation":"Farrant P, Meire HB, Mieli-Vergani G. Ultrasound features of the gall bladder in infants presenting with conjugated hyperbilirubinaemia. Br J Radiol. 2000;73(875):1154-1158. doi:10.1259/bjr.73.875.11144791","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"467","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":467,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.73,"specificity":0.94},"tp":44.0,"fp":15.0,"fn":16.0,"tn":256.0,"sample_size":331.0,"observed_prevalence":0.18126888217522658,"sensitivity":0.7333333333333333,"specificity":0.9446494464944649,"ppv_observed":0.7457627118644068,"npv_observed":0.9411764705882353,"youden_j":0.6779827798277982,"lr_positive":13.248888888888882,"lr_negative":0.2822916666666667,"diagnostic_odds_ratio":46.93333333333333,"baseline_entropy_bits_observed":0.682845032355827,"conditional_entropy_bits_observed":0.41101958482861656,"information_bits_observed":0.2718254475272105,"information_fraction_observed":0.39807779898377244,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8497a301b372"},{"id":"diagnostics-2024:468:c4d4283fe50a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Glycosylated ferritin","test_or_feature":"Glycosylated ferritin","target_condition":"Hemophagocytic lymphohistiocytosis","citation":"Fardet L, Coppo P, Kettaneh A, Dehoux M, Cabane J, Lambotte O. Low glycosylated ferritin, a good marker for the diagnosis of hemophagocytic syndrome. Arthritis Rheum. 2008;58(5):1521-1527. doi:10.1002/art.23415","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"468","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":468,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.86,"specificity":0.76},"tp":12.0,"fp":5.0,"fn":2.0,"tn":16.0,"sample_size":35.0,"observed_prevalence":0.4,"sensitivity":0.8571428571428571,"specificity":0.7619047619047619,"ppv_observed":0.7058823529411765,"npv_observed":0.8888888888888888,"youden_j":0.6190476190476191,"lr_positive":3.599999999999999,"lr_negative":0.18750000000000008,"diagnostic_odds_ratio":19.2,"baseline_entropy_bits_observed":0.9709505944546686,"conditional_entropy_bits_observed":0.6833236526893344,"information_bits_observed":0.2876269417653342,"information_fraction_observed":0.2962323144020309,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"91b32aeae622"},{"id":"diagnostics-2024:469:ed9e7d0442e9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"3D-CTAG","test_or_feature":"3D-CTAG","target_condition":"Age-related macular degeneration","citation":"Faes L, Bodmer NS, Bachmann LM, Thiel MA, Schmid MK. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis. Eye (Lond). 2014;28(7):788-796. doi:10.1038/eye.2014.110","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"469","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":469,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":29.0,"fp":0.0,"fn":0.0,"tn":27.0,"sample_size":56.0,"observed_prevalence":0.5178571428571429,"sensitivity":1.0,"specificity":1.0,"ppv_observed":1.0,"npv_observed":1.0,"youden_j":1.0,"lr_positive":null,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9990797181805819,"conditional_entropy_bits_observed":0.0,"information_bits_observed":0.9990797181805819,"information_fraction_observed":1.0,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fee7dec2c308"},{"id":"diagnostics-2024:470:960599041590","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Modified Amsler grid","test_or_feature":"Modified Amsler grid","target_condition":"Age-related macular degeneration","citation":"Faes L, Bodmer NS, Bachmann LM, Thiel MA, Schmid MK. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis. Eye (Lond). 2014;28(7):788-796. doi:10.1038/eye.2014.109","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"470","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":470,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.73,"specificity":0.98},"tp":53.0,"fp":3.0,"fn":20.0,"tn":124.0,"sample_size":200.0,"observed_prevalence":0.365,"sensitivity":0.726027397260274,"specificity":0.9763779527559056,"ppv_observed":0.9464285714285714,"npv_observed":0.8611111111111112,"youden_j":0.7024053500161795,"lr_positive":30.735159817351654,"lr_negative":0.2806009721608484,"diagnostic_odds_ratio":109.53333333333333,"baseline_entropy_bits_observed":0.9467554496831931,"conditional_entropy_bits_observed":0.50293749931593,"information_bits_observed":0.4438179503672631,"information_fraction_observed":0.4687778142874965,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e41750561673"},{"id":"diagnostics-2024:471:6f2383e59dc0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Preferential hyperacuity perimetry (home device)","test_or_feature":"Preferential hyperacuity perimetry (home device)","target_condition":"Age-related macular degeneration","citation":"Faes L, Bodmer NS, Bachmann LM, Thiel MA, Schmid MK. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis. Eye (Lond). 2014;28(7):788-796. doi:10.1038/eye.2014.108","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"471","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":471,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.85,"specificity":0.85},"tp":56.0,"fp":10.0,"fn":10.0,"tn":55.0,"sample_size":131.0,"observed_prevalence":0.5038167938931297,"sensitivity":0.8484848484848485,"specificity":0.8461538461538461,"ppv_observed":0.8484848484848485,"npv_observed":0.8461538461538461,"youden_j":0.6946386946386947,"lr_positive":5.515151515151515,"lr_negative":0.17906336088154268,"diagnostic_odds_ratio":30.8,"baseline_entropy_bits_observed":0.9999579654725077,"conditional_entropy_bits_observed":0.6164786102876192,"information_bits_observed":0.3834793551848885,"information_fraction_observed":0.3834954752359855,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2944abd177c4"},{"id":"diagnostics-2024:472:7cd3c3377da9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Macular computerized psychophysical test","test_or_feature":"Macular computerized psychophysical test","target_condition":"Age-related macular degeneration","citation":"Faes L, Bodmer NS, Bachmann LM, Thiel MA, Schmid MK. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis. Eye (Lond). 2014;28(7):788-796. doi:10.1038/eye.2014.107","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"472","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":472,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.94,"specificity":0.94},"tp":30.0,"fp":3.0,"fn":2.0,"tn":48.0,"sample_size":83.0,"observed_prevalence":0.3855421686746988,"sensitivity":0.9375,"specificity":0.9411764705882353,"ppv_observed":0.9090909090909091,"npv_observed":0.96,"youden_j":0.8786764705882353,"lr_positive":15.937499999999996,"lr_negative":0.06640625,"diagnostic_odds_ratio":240.0,"baseline_entropy_bits_observed":0.9618624139909456,"conditional_entropy_bits_observed":0.3206989159341046,"information_bits_observed":0.641163498056841,"information_fraction_observed":0.6665854583053461,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0c2ee0c828ce"},{"id":"diagnostics-2024:473:8c38f89d7788","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"M-Chart","test_or_feature":"M-Chart","target_condition":"Age-related macular degeneration","citation":"Faes L, Bodmer NS, Bachmann LM, Thiel MA, Schmid MK. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis. Eye (Lond). 2014;28(7):788-796. doi:10.1038/eye.2014.106","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"473","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":473,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.84,"specificity":1.0},"tp":46.0,"fp":0.0,"fn":9.0,"tn":74.0,"sample_size":129.0,"observed_prevalence":0.4263565891472868,"sensitivity":0.8363636363636363,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.891566265060241,"youden_j":0.8363636363636364,"lr_positive":null,"lr_negative":0.1636363636363637,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9842944391410947,"conditional_entropy_bits_observed":0.31859999017264856,"information_bits_observed":0.6656944489684462,"information_fraction_observed":0.6763163769870913,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d023dad9ff1f"},{"id":"diagnostics-2024:474:0c6ace385a62","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Preferential hyperacuity perimetry","test_or_feature":"Preferential hyperacuity perimetry","target_condition":"Age-related macular degeneration","citation":"Faes L, Bodmer NS, Bachmann LM, Thiel MA, Schmid MK. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis. Eye (Lond). 2014;28(7):788-796. doi:10.1038/eye.2014.105","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"474","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":474,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.85,"specificity":0.86},"tp":204.0,"fp":50.0,"fn":37.0,"tn":309.0,"sample_size":600.0,"observed_prevalence":0.40166666666666667,"sensitivity":0.8464730290456431,"specificity":0.8607242339832869,"ppv_observed":0.8031496062992126,"npv_observed":0.8930635838150289,"youden_j":0.70719726302893,"lr_positive":6.077676348547717,"lr_negative":0.1783695228887188,"diagnostic_odds_ratio":34.07351351351351,"baseline_entropy_bits_observed":0.9719171868727204,"conditional_entropy_bits_observed":0.585846413001321,"information_bits_observed":0.38607077387139943,"information_fraction_observed":0.3972259973235335,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a7b17d9e6ced"},{"id":"diagnostics-2024:475:311b6184b149","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Amsler grid","test_or_feature":"Amsler grid","target_condition":"Age-related macular degeneration","citation":"Faes L, Bodmer NS, Bachmann LM, Thiel MA, Schmid MK. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis. Eye (Lond). 2014;28(7):788-796. doi:10.1038/eye.2014.104","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"475","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":475,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.86,"specificity":0.91},"tp":392.0,"fp":27.0,"fn":66.0,"tn":280.0,"sample_size":765.0,"observed_prevalence":0.5986928104575163,"sensitivity":0.8558951965065502,"specificity":0.9120521172638436,"ppv_observed":0.9355608591885441,"npv_observed":0.8092485549132948,"youden_j":0.7679473137703938,"lr_positive":9.7318453825004,"lr_negative":0.15800062383031815,"diagnostic_odds_ratio":61.59371492704826,"baseline_entropy_bits_observed":0.9717101173485823,"conditional_entropy_bits_observed":0.506838933867335,"information_bits_observed":0.46487118348124723,"information_fraction_observed":0.4784052107532844,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"99e133800865"},{"id":"diagnostics-2024:476:e202863eadc1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lymphocyte-to-monocyte ratio","test_or_feature":"Lymphocyte-to-monocyte ratio","target_condition":"Rheumatoid arthritis","citation":"Erre GL et al. Diagnostic accuracy of different blood cells-derived indexes in rheumatoid arthritis: A cross-sectional study. Medicine 99(44):p e22557, October 30, 2020. doi: 10.1097/MD.0000000000022557","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"476","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":476,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.64,"specificity":0.65},"tp":127.0,"fp":98.0,"fn":72.0,"tn":185.0,"sample_size":482.0,"observed_prevalence":0.41286307053941906,"sensitivity":0.6381909547738693,"specificity":0.6537102473498233,"ppv_observed":0.5644444444444444,"npv_observed":0.7198443579766537,"youden_j":0.29190120212369264,"lr_positive":1.842939185724541,"lr_negative":0.5534700529675405,"diagnostic_odds_ratio":3.3297902494331066,"baseline_entropy_bits_observed":0.9779794146332629,"conditional_entropy_bits_observed":0.9174306782654363,"information_bits_observed":0.06054873636782654,"information_fraction_observed":0.0619120765343839,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6293d09aec95"},{"id":"diagnostics-2024:477:a728cdaa2582","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Vaginal smear","test_or_feature":"Vaginal smear","target_condition":"Vaginal Candida infection","citation":"Engberts MK, Goedbloed AF, van Haaften M, Boon ME, Heintz PM. Microscopic diagnosis of vulvovaginal candidiasis in stained vaginal smears by Dutch general practitioners [published correction appears in Acta Cytol. 2008 Jan-Feb;52(1):128A. van Haaften, Mathilde [corrected to van Haaften, Maarten]; Boon, Maarten E [corrected to Boon, Mathilde E]]. Acta Cytol. 2007;51(6):882-885. doi:10.1159/000325864","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"477","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":477,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.52,"specificity":0.89},"tp":54.0,"fp":24.0,"fn":50.0,"tn":196.0,"sample_size":324.0,"observed_prevalence":0.32098765432098764,"sensitivity":0.5192307692307693,"specificity":0.8909090909090909,"ppv_observed":0.6923076923076923,"npv_observed":0.7967479674796748,"youden_j":0.41013986013986026,"lr_positive":4.759615384615383,"lr_negative":0.5396389324960753,"diagnostic_odds_ratio":8.82,"baseline_entropy_bits_observed":0.9054522631867892,"conditional_entropy_bits_observed":0.7674104238125194,"information_bits_observed":0.13804183937426973,"information_fraction_observed":0.15245623097613545,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d5bf4f01426c"},{"id":"diagnostics-2024:478:c3a61ae85b4f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Dermatitis herpetiformis","test_or_feature":"Dermatitis herpetiformis","target_condition":"Celiac disease","citation":"Elwenspoek MMC, Jackson J, O'Donnell R, et al. The accuracy of diagnostic indicators for coeliac disease: A systematic review and meta-analysis. PLoS One. 2021;16(10):e0258501. Published 2021 Oct 25. doi:10.1371/journal.pone.0258504","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"478","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":478,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.11,"specificity":0.96},"tp":64.0,"fp":36.0,"fn":515.0,"tn":812.0,"sample_size":1427.0,"observed_prevalence":0.40574632095304836,"sensitivity":0.11053540587219343,"specificity":0.9575471698113207,"ppv_observed":0.64,"npv_observed":0.611906556141673,"youden_j":0.06808257568351417,"lr_positive":2.6037228938783312,"lr_negative":0.928898985000468,"diagnostic_odds_ratio":2.80302049622438,"baseline_entropy_bits_observed":0.9742128864937306,"conditional_entropy_bits_observed":0.9620952960624272,"information_bits_observed":0.012117590431303449,"information_fraction_observed":0.012438339298626625,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4845e18c0119"},{"id":"diagnostics-2024:479:1888537e0bf7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Vomiting","test_or_feature":"Vomiting","target_condition":"Celiac disease","citation":"Elwenspoek MMC, Jackson J, O'Donnell R, et al. The accuracy of diagnostic indicators for coeliac disease: A systematic review and meta-analysis. PLoS One. 2021;16(10):e0258501. Published 2021 Oct 25. doi:10.1371/journal.pone.0258503","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"479","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":479,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.11,"specificity":0.89},"tp":48.0,"fp":4898.0,"fn":387.0,"tn":39604.0,"sample_size":44937.0,"observed_prevalence":0.009680218973229187,"sensitivity":0.1103448275862069,"specificity":0.8899375308974877,"ppv_observed":0.009704811969268095,"npv_observed":0.9903228226350929,"youden_j":0.00028235848369462246,"lr_positive":1.0025654383914615,"lr_negative":0.9996827210069342,"diagnostic_odds_ratio":1.0028836323004802,"baseline_entropy_bits_observed":0.07866566252361087,"conditional_entropy_bits_observed":0.0786656568991644,"information_bits_observed":5.624446478003087e-09,"information_fraction_observed":7.149811363140752e-08,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"34b861eabc38"},{"id":"diagnostics-2024:480:53733dc78c43","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Diarrhea","test_or_feature":"Diarrhea","target_condition":"Celiac disease","citation":"Elwenspoek MMC, Jackson J, O'Donnell R, et al. The accuracy of diagnostic indicators for coeliac disease: A systematic review and meta-analysis. PLoS One. 2021;16(10):e0258501. Published 2021 Oct 25. doi:10.1371/journal.pone.0258502","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"480","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":480,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.14,"specificity":0.88},"tp":161.0,"fp":6384.0,"fn":965.0,"tn":47990.0,"sample_size":55500.0,"observed_prevalence":0.020288288288288287,"sensitivity":0.14298401420959148,"specificity":0.8825909442012727,"ppv_observed":0.02459893048128342,"npv_observed":0.9802880196098458,"youden_j":0.025574958410864213,"lr_positive":1.217827817768222,"lr_negative":0.9710228633333542,"diagnostic_odds_ratio":1.2541700754476865,"baseline_entropy_bits_observed":0.14305615318645962,"conditional_entropy_bits_observed":0.14297089148554293,"information_bits_observed":8.526170091668894e-05,"information_fraction_observed":0.0005960016330479592,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"05a0b0ea04e5"},{"id":"diagnostics-2024:481:f6075f9b0599","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal pain","test_or_feature":"Abdominal pain","target_condition":"Celiac disease","citation":"Elwenspoek MMC, Jackson J, O'Donnell R, et al. The accuracy of diagnostic indicators for coeliac disease: A systematic review and meta-analysis. PLoS One. 2021;16(10):e0258501. Published 2021 Oct 25. doi:10.1371/journal.pone.0258501","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"481","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":481,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.25,"specificity":0.7},"tp":255.0,"fp":14345.0,"fn":759.0,"tn":33092.0,"sample_size":48451.0,"observed_prevalence":0.02092836061175208,"sensitivity":0.2514792899408284,"specificity":0.6975989206737357,"ppv_observed":0.017465753424657535,"npv_observed":0.9775782103926028,"youden_j":-0.0509217893854359,"lr_positive":0.8316084403571334,"lr_negative":1.0729957972645026,"diagnostic_odds_ratio":0.775034200951427,"baseline_entropy_bits_observed":0.1466217687358184,"conditional_entropy_bits_observed":0.14643345915297934,"information_bits_observed":0.00018830958283905241,"information_fraction_observed":0.0012843221334912873,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"036c2b11ce6f"},{"id":"diagnostics-2024:482:a2b6f403e2d4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"C-reactive protein","test_or_feature":"C-reactive protein","target_condition":"Spontaneous bacterial peritonitis","citation":"Elsadek, H.M., Elhawari, S.A. & Mokhtar, A. A novel serum index for accurate diagnosis of spontaneous bacterial peritonitis in cirrhotic patients without other infections. Egypt Liver Journal 10, 10 (2020). https://doi.org/10.1186/s43066-020-0021-9","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"482","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":482,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.93,"specificity":0.52},"tp":56.0,"fp":57.0,"fn":4.0,"tn":61.0,"sample_size":178.0,"observed_prevalence":0.33707865168539325,"sensitivity":0.9333333333333333,"specificity":0.5169491525423728,"ppv_observed":0.49557522123893805,"npv_observed":0.9384615384615385,"youden_j":0.4502824858757062,"lr_positive":1.9321637426900584,"lr_negative":0.12896174863387977,"diagnostic_odds_ratio":14.982456140350877,"baseline_entropy_bits_observed":0.9219957030944405,"conditional_entropy_bits_observed":0.7565873402573797,"information_bits_observed":0.16540836283706073,"information_fraction_observed":0.1794025311418592,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"514147da8aeb"},{"id":"diagnostics-2024:483:61d4ec2dba70","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Erythrocyte sedimentation rate","test_or_feature":"Erythrocyte sedimentation rate","target_condition":"Spontaneous bacterial peritonitis","citation":"Elsadek, H.M., Elhawari, S.A. & Mokhtar, A. A novel serum index for accurate diagnosis of spontaneous bacterial peritonitis in cirrhotic patients without other infections. Egypt Liver Journal 10, 10 (2020). https://doi.org/10.1186/s43066-020-0021-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"483","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":483,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.73,"specificity":0.62},"tp":44.0,"fp":45.0,"fn":16.0,"tn":73.0,"sample_size":178.0,"observed_prevalence":0.33707865168539325,"sensitivity":0.7333333333333333,"specificity":0.6186440677966102,"ppv_observed":0.4943820224719101,"npv_observed":0.8202247191011236,"youden_j":0.35197740112994347,"lr_positive":1.922962962962963,"lr_negative":0.4310502283105024,"diagnostic_odds_ratio":4.461111111111111,"baseline_entropy_bits_observed":0.9219957030944405,"conditional_entropy_bits_observed":0.8397470638140512,"information_bits_observed":0.08224863928038928,"information_fraction_observed":0.08920718285816621,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a69749f37732"},{"id":"diagnostics-2024:484:8c022fe40cf9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PEC index","test_or_feature":"PEC index","target_condition":"Spontaneous bacterial peritonitis","citation":"Elsadek, H.M., Elhawari, S.A. & Mokhtar, A. A novel serum index for accurate diagnosis of spontaneous bacterial peritonitis in cirrhotic patients without other infections. Egypt Liver Journal 10, 10 (2020). https://doi.org/10.1186/s43066-020-0021-10","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"484","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":484,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.98,"specificity":0.97},"tp":59.0,"fp":4.0,"fn":1.0,"tn":114.0,"sample_size":178.0,"observed_prevalence":0.33707865168539325,"sensitivity":0.9833333333333333,"specificity":0.9661016949152542,"ppv_observed":0.9365079365079365,"npv_observed":0.991304347826087,"youden_j":0.9494350282485875,"lr_positive":29.008333333333315,"lr_negative":0.017251461988304146,"diagnostic_odds_ratio":1681.5,"baseline_entropy_bits_observed":0.9219957030944405,"conditional_entropy_bits_observed":0.16727297478634096,"information_bits_observed":0.7547227283080995,"information_fraction_observed":0.8185751037397111,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"38ad1bf18e5c"},{"id":"diagnostics-2024:485:11830648b711","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Tinel's sign","test_or_feature":"Tinel's sign","target_condition":"Forearm flexor tenosynovitis","citation":"El Miedany Y, Ashour S, Youssef S, Mehanna A, Meky FA. Clinical diagnosis of carpal tunnel syndrome: old tests-new concepts. Joint Bone Spine. 2008;75(4):451-457. doi:10.1016/j.jbspin.2007.09.017","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"485","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":485,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.46,"specificity":0.85},"tp":55.0,"fp":44.0,"fn":64.0,"tn":251.0,"sample_size":414.0,"observed_prevalence":0.28743961352657005,"sensitivity":0.46218487394957986,"specificity":0.8508474576271187,"ppv_observed":0.5555555555555556,"npv_observed":0.7968253968253968,"youden_j":0.3130323315766985,"lr_positive":3.09873949579832,"lr_negative":0.6320934748401352,"diagnostic_odds_ratio":4.90234375,"baseline_entropy_bits_observed":0.8653908188829958,"conditional_entropy_bits_observed":0.7910860475225436,"information_bits_observed":0.07430477136045222,"information_fraction_observed":0.08586267584437882,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5575f6ffb5d0"},{"id":"diagnostics-2024:486:daac0e270d7c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Reverse Phalen's test","test_or_feature":"Reverse Phalen's test","target_condition":"Forearm flexor tenosynovitis","citation":"El Miedany Y, Ashour S, Youssef S, Mehanna A, Meky FA. Clinical diagnosis of carpal tunnel syndrome: old tests-new concepts. Joint Bone Spine. 2008;75(4):451-457. doi:10.1016/j.jbspin.2007.09.016","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"486","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":486,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.75,"specificity":0.85},"tp":89.0,"fp":44.0,"fn":30.0,"tn":251.0,"sample_size":414.0,"observed_prevalence":0.28743961352657005,"sensitivity":0.7478991596638656,"specificity":0.8508474576271187,"ppv_observed":0.6691729323308271,"npv_observed":0.8932384341637011,"youden_j":0.5987466172909843,"lr_positive":5.014323911382736,"lr_negative":0.2962938163313134,"diagnostic_odds_ratio":16.923484848484847,"baseline_entropy_bits_observed":0.8653908188829958,"conditional_entropy_bits_observed":0.6268283657434508,"information_bits_observed":0.23856245313954505,"information_fraction_observed":0.2756701919341712,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"86a86a2af63d"},{"id":"diagnostics-2024:487:ff814fedb56d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Phalen's test","test_or_feature":"Phalen's test","target_condition":"Forearm flexor tenosynovitis","citation":"El Miedany Y, Ashour S, Youssef S, Mehanna A, Meky FA. Clinical diagnosis of carpal tunnel syndrome: old tests-new concepts. Joint Bone Spine. 2008;75(4):451-457. doi:10.1016/j.jbspin.2007.09.015","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"487","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":487,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.92,"specificity":0.87},"tp":109.0,"fp":38.0,"fn":10.0,"tn":257.0,"sample_size":414.0,"observed_prevalence":0.28743961352657005,"sensitivity":0.9159663865546218,"specificity":0.8711864406779661,"ppv_observed":0.7414965986394558,"npv_observed":0.9625468164794008,"youden_j":0.7871528272325881,"lr_positive":7.1107916850950925,"lr_negative":0.09645881698983098,"diagnostic_odds_ratio":73.71842105263158,"baseline_entropy_bits_observed":0.8653908188829958,"conditional_entropy_bits_observed":0.4413998102615482,"information_bits_observed":0.4239910086214477,"information_fraction_observed":0.48994165337773576,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9f852fab6625"},{"id":"diagnostics-2024:488:c49447d4d32e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Carpal tunnel compression","test_or_feature":"Carpal tunnel compression","target_condition":"Forearm flexor tenosynovitis","citation":"El Miedany Y, Ashour S, Youssef S, Mehanna A, Meky FA. Clinical diagnosis of carpal tunnel syndrome: old tests-new concepts. Joint Bone Spine. 2008;75(4):451-457. doi:10.1016/j.jbspin.2007.09.014","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"488","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":488,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.95,"specificity":0.97},"tp":113.0,"fp":9.0,"fn":6.0,"tn":286.0,"sample_size":414.0,"observed_prevalence":0.28743961352657005,"sensitivity":0.9495798319327731,"specificity":0.9694915254237289,"ppv_observed":0.9262295081967213,"npv_observed":0.9794520547945206,"youden_j":0.9190713573565019,"lr_positive":31.125116713352043,"lr_negative":0.052006816712699105,"diagnostic_odds_ratio":598.4814814814815,"baseline_entropy_bits_observed":0.8653908188829958,"conditional_entropy_bits_observed":0.21385555866375316,"information_bits_observed":0.6515352602192427,"information_fraction_observed":0.7528797925776617,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3f25b6ad5df4"},{"id":"diagnostics-2024:489:dbdcaaf1086d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Head X-ray","test_or_feature":"Head X-ray","target_condition":"Acute rhinosinusitis","citation":"Ebell MH, McKay B, Guilbault R, Ermias Y. Diagnosis of acute rhinosinusitis in primary care: a systematic review of test accuracy. Br J Gen Pract. 2016;66(650):e612-e632. doi:10.3399/bjgp16X686581","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"489","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":489,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.87,"specificity":0.53},"tp":645.0,"fp":388.0,"fn":100.0,"tn":431.0,"sample_size":1564.0,"observed_prevalence":0.47634271099744246,"sensitivity":0.8657718120805369,"specificity":0.5262515262515263,"ppv_observed":0.6243949661181026,"npv_observed":0.8116760828625236,"youden_j":0.39202333833206326,"lr_positive":1.8274925620978344,"lr_negative":0.2550647004780517,"diagnostic_odds_ratio":7.164819587628866,"baseline_entropy_bits_observed":0.9983845383947044,"conditional_entropy_bits_observed":0.8676485239519087,"information_bits_observed":0.1307360144427957,"information_fraction_observed":0.1309475551905133,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"69672e48ec9f"},{"id":"diagnostics-2024:490:aa830b5897b5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Head US","test_or_feature":"Head US","target_condition":"Acute rhinosinusitis","citation":"Ebell MH, McKay B, Guilbault R, Ermias Y. Diagnosis of acute rhinosinusitis in primary care: a systematic review of test accuracy. Br J Gen Pract. 2016;66(650):e612-e632. doi:10.3399/bjgp16X686581","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"490","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":490,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.83,"specificity":0.55},"tp":279.0,"fp":97.0,"fn":56.0,"tn":120.0,"sample_size":552.0,"observed_prevalence":0.6068840579710145,"sensitivity":0.8328358208955224,"specificity":0.5529953917050692,"ppv_observed":0.7420212765957447,"npv_observed":0.6818181818181818,"youden_j":0.3858312126005916,"lr_positive":1.8631481766425606,"lr_negative":0.3022885572139302,"diagnostic_odds_ratio":6.163475699558174,"baseline_entropy_bits_observed":0.9667809639682556,"conditional_entropy_bits_observed":0.8487775983880674,"information_bits_observed":0.1180033655801882,"information_fraction_observed":0.12205801518456755,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"879d702d7f6f"},{"id":"diagnostics-2024:491:1279a0a9b5fb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ELISA","test_or_feature":"ELISA","target_condition":"Botulinum toxins","citation":"Dezfulian M, Hatheway CL, Yolken RH, Bartlett JG. Enzyme-linked immunosorbent assay for detection of Clostridium botulinum type A and type B toxins in stool samples of infants with botulism. J Clin Microbiol. 1984;20(3):379-383. doi:10.1128/jcm.20.3.379-383.1984","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"491","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":491,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1984,"source_reported":{"sensitivity":0.96,"specificity":0.96},"tp":24.0,"fp":2.0,"fn":1.0,"tn":53.0,"sample_size":80.0,"observed_prevalence":0.3125,"sensitivity":0.96,"specificity":0.9636363636363636,"ppv_observed":0.9230769230769231,"npv_observed":0.9814814814814815,"youden_j":0.9236363636363636,"lr_positive":26.39999999999999,"lr_negative":0.04150943396226419,"diagnostic_odds_ratio":636.0,"baseline_entropy_bits_observed":0.8960382325345574,"conditional_entropy_bits_observed":0.21695592099172983,"information_bits_observed":0.6790823115428275,"information_fraction_observed":0.7578720269803191,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0b2b9f24af53"},{"id":"diagnostics-2024:492:6ce7288ef709","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Affirm VP deoxyribonucleic acid probe test","test_or_feature":"Affirm VP deoxyribonucleic acid probe test","target_condition":"Vaginal Trichomonas vaginalis infection","citation":"DeMeo LR, Draper DL, McGregor JA, et al. Evaluation of a deoxyribonucleic acid probe for the detection of Trichomonas vaginalis in vaginal secretions. Am J Obstet Gynecol. 1996;174(4):1339-1342. doi:10.1016/s0002-9378(96)70682-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"492","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":492,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1996,"source_reported":{"sensitivity":0.9,"specificity":1.0},"tp":86.0,"fp":1.0,"fn":10.0,"tn":519.0,"sample_size":616.0,"observed_prevalence":0.15584415584415584,"sensitivity":0.8958333333333334,"specificity":0.9980769230769231,"ppv_observed":0.9885057471264368,"npv_observed":0.9810964083175804,"youden_j":0.8939102564102566,"lr_positive":465.833333333335,"lr_negative":0.10436737315350028,"diagnostic_odds_ratio":4463.4,"baseline_entropy_bits_observed":0.6242741010130388,"conditional_entropy_bits_observed":0.12892694119507264,"information_bits_observed":0.4953471598179662,"information_fraction_observed":0.7934770303847991,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e1499bd7fd1c"},{"id":"diagnostics-2024:493:05748baa217e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid antibody test","test_or_feature":"Rapid antibody test","target_condition":"HIV","citation":"Delaney KP, Branson BM, Uniyal A, et al. Performance of an oral fluid rapid HIV-1/2 test: experience from four CDC studies. AIDS. 2006;20(12):1655-1660. doi:10.1097/01.aids.0000238412.75324.82","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"493","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":493,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":1.0,"specificity":1.0},"tp":326.0,"fp":12.0,"fn":1.0,"tn":11998.0,"sample_size":12337.0,"observed_prevalence":0.026505633460322607,"sensitivity":0.9969418960244648,"specificity":0.9990008326394672,"ppv_observed":0.9644970414201184,"npv_observed":0.9999166597216435,"youden_j":0.995942728663932,"lr_positive":997.7726809378589,"lr_negative":0.0030611625892796794,"diagnostic_odds_ratio":325945.6666666667,"baseline_entropy_bits_observed":0.1765529969973511,"conditional_entropy_bits_observed":0.00727774845206257,"information_bits_observed":0.16927524854528853,"information_fraction_observed":0.9587786750956611,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b4bab1103fe0"},{"id":"diagnostics-2024:494:0d8aeca9cdd1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Bicipital groove tenderness","test_or_feature":"Bicipital groove tenderness","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100985","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"494","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":494,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.33,"specificity":0.66},"tp":41.0,"fp":46.0,"fn":84.0,"tn":89.0,"sample_size":260.0,"observed_prevalence":0.4807692307692308,"sensitivity":0.328,"specificity":0.6592592592592592,"ppv_observed":0.47126436781609193,"npv_observed":0.5144508670520231,"youden_j":-0.01274074074074072,"lr_positive":0.9626086956521738,"lr_negative":1.0193258426966292,"diagnostic_odds_ratio":0.9443581780538303,"baseline_entropy_bits_observed":0.9989326546260582,"conditional_entropy_bits_observed":0.9988013326253977,"information_bits_observed":0.00013132200066046096,"information_fraction_observed":0.00013146231635567085,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"901dc51ff6b6"},{"id":"diagnostics-2024:495:63f6e5c4482a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Kim 2 test","test_or_feature":"Kim 2 test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100984","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"495","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":495,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.37,"specificity":0.72},"tp":57.0,"fp":49.0,"fn":96.0,"tn":123.0,"sample_size":325.0,"observed_prevalence":0.4707692307692308,"sensitivity":0.37254901960784315,"specificity":0.7151162790697675,"ppv_observed":0.5377358490566038,"npv_observed":0.5616438356164384,"youden_j":0.08766529867761053,"lr_positive":1.3077230892356946,"lr_negative":0.877411127052447,"diagnostic_odds_ratio":1.4904336734693877,"baseline_entropy_bits_observed":0.997533207175089,"conditional_entropy_bits_observed":0.991251497973425,"information_bits_observed":0.006281709201663932,"information_fraction_observed":0.006297243195996536,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"89bc09e4cadb"},{"id":"diagnostics-2024:496:40710bf6d8d9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Dynamic labral shear test","test_or_feature":"Dynamic labral shear test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100983","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"496","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":496,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.74,"specificity":0.65},"tp":265.0,"fp":213.0,"fn":93.0,"tn":390.0,"sample_size":961.0,"observed_prevalence":0.372528616024974,"sensitivity":0.7402234636871509,"specificity":0.6467661691542289,"ppv_observed":0.5543933054393305,"npv_observed":0.8074534161490683,"youden_j":0.38698963284137977,"lr_positive":2.0955622000157375,"lr_negative":0.4016544907606359,"diagnostic_odds_ratio":5.217325458125095,"baseline_entropy_bits_observed":0.9525938632541302,"conditional_entropy_bits_observed":0.848366771784161,"information_bits_observed":0.10422709146996922,"information_fraction_observed":0.10941398584484038,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"883fd06563b7"},{"id":"diagnostics-2024:497:88a980dcd1a3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Jobe test","test_or_feature":"Jobe test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100982","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"497","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":497,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.39,"specificity":0.57},"tp":126.0,"fp":368.0,"fn":194.0,"tn":478.0,"sample_size":1166.0,"observed_prevalence":0.274442538593482,"sensitivity":0.39375,"specificity":0.5650118203309693,"ppv_observed":0.2550607287449393,"npv_observed":0.7113095238095238,"youden_j":-0.04123817966903065,"lr_positive":0.9051970108695653,"lr_negative":1.0729864016736401,"diagnostic_odds_ratio":0.843623935454953,"baseline_entropy_bits_observed":0.8477674161649618,"conditional_entropy_bits_observed":0.846762628405735,"information_bits_observed":0.001004787759226744,"information_fraction_observed":0.0011852162987958346,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0418e07a368b"},{"id":"diagnostics-2024:498:e0bd7b6a9ead","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Crank test","test_or_feature":"Crank test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100981","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"498","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":498,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.41,"specificity":0.64},"tp":66.0,"fp":99.0,"fn":95.0,"tn":178.0,"sample_size":438.0,"observed_prevalence":0.3675799086757991,"sensitivity":0.40993788819875776,"specificity":0.6425992779783394,"ppv_observed":0.4,"npv_observed":0.652014652014652,"youden_j":0.05253716617709703,"lr_positive":1.1469979296066253,"lr_negative":0.9182427245446297,"diagnostic_odds_ratio":1.249122807017544,"baseline_entropy_bits_observed":0.948795741400081,"conditional_entropy_bits_observed":0.9468326804855736,"information_bits_observed":0.001963060914507486,"information_fraction_observed":0.002069002661848708,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e4e132616a76"},{"id":"diagnostics-2024:499:83c8286a8d8c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Anterior slide test","test_or_feature":"Anterior slide test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100980","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"499","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":499,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.36,"specificity":0.82},"tp":104.0,"fp":159.0,"fn":183.0,"tn":741.0,"sample_size":1187.0,"observed_prevalence":0.2417860151642797,"sensitivity":0.3623693379790941,"specificity":0.8233333333333334,"ppv_observed":0.39543726235741444,"npv_observed":0.801948051948052,"youden_j":0.18570267131242746,"lr_positive":2.0511471961080803,"lr_negative":0.7744501967865254,"diagnostic_odds_ratio":2.6485204660274255,"baseline_entropy_bits_observed":0.7979977663552549,"conditional_entropy_bits_observed":0.7734517993519998,"information_bits_observed":0.024545967003255065,"information_fraction_observed":0.030759443244265453,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bc3c86683fcf"},{"id":"diagnostics-2024:500:6a08478c0988","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Yergason's test","test_or_feature":"Yergason's test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100979","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"500","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":500,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.18,"specificity":0.88},"tp":44.0,"fp":37.0,"fn":197.0,"tn":265.0,"sample_size":543.0,"observed_prevalence":0.4438305709023941,"sensitivity":0.1825726141078838,"specificity":0.8774834437086093,"ppv_observed":0.5432098765432098,"npv_observed":0.5735930735930735,"youden_j":0.060056057816493036,"lr_positive":1.4901872827184035,"lr_negative":0.9315587567525248,"diagnostic_odds_ratio":1.5996707367265743,"baseline_entropy_bits_observed":0.9908773356725116,"conditional_entropy_bits_observed":0.9858509531901585,"information_bits_observed":0.005026382482353098,"information_fraction_observed":0.005072658644414019,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"40d22b809927"},{"id":"diagnostics-2024:501:d94662201641","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Speed's test","test_or_feature":"Speed's test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100978","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"501","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":501,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.31,"specificity":0.66},"tp":88.0,"fp":104.0,"fn":198.0,"tn":200.0,"sample_size":590.0,"observed_prevalence":0.4847457627118644,"sensitivity":0.3076923076923077,"specificity":0.6578947368421053,"ppv_observed":0.4583333333333333,"npv_observed":0.5025125628140703,"youden_j":-0.03441295546558698,"lr_positive":0.8994082840236688,"lr_negative":1.0523076923076922,"diagnostic_odds_ratio":0.8547008547008547,"baseline_entropy_bits_observed":0.9993284893246792,"conditional_entropy_bits_observed":0.998355656368425,"information_bits_observed":0.000972832956254166,"information_fraction_observed":0.0009734866629406131,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cef32608ac08"},{"id":"diagnostics-2024:502:c37fb529c1b6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"O'Brien test","test_or_feature":"O'Brien test","target_condition":"Superior labrum anterior to posterior tear","citation":"Dean RS, Onsen L, Lima J, Hutchinson MR. Physical Examination Maneuvers for SLAP Lesions: A Systematic Review and Meta-analysis of Individual and Combinations of Maneuvers. The American Journal of Sports Medicine. 2022;0(0). doi:10.1177/03635465221100977","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"502","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":502,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.63,"specificity":0.54},"tp":496.0,"fp":834.0,"fn":297.0,"tn":994.0,"sample_size":2621.0,"observed_prevalence":0.3025562762304464,"sensitivity":0.6254728877679697,"specificity":0.5437636761487965,"ppv_observed":0.37293233082706767,"npv_observed":0.7699457784663052,"youden_j":0.16923656391676634,"lr_positive":1.3709405741484997,"lr_negative":0.6887681701812388,"diagnostic_odds_ratio":1.9904238225581152,"baseline_entropy_bits_observed":0.8843932620524135,"conditional_entropy_bits_observed":0.8668018536256688,"information_bits_observed":0.01759140842674478,"information_fraction_observed":0.019890934476276264,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1fcc7c962c25"},{"id":"diagnostics-2024:503:850e612a089e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Anorectal manometry","test_or_feature":"Anorectal manometry","target_condition":"Hirschsprung's disease","citation":"De Lorijn F, Reitsma JB, Voskuijl WP, et al. Diagnosis of Hirschsprung's disease: a prospective, comparative accuracy study of common tests. J Pediatr. 2005;146(6):787-792. doi:10.1016/j.jpeds.2005.01.046","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"503","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":503,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.82,"specificity":0.93},"tp":23.0,"fp":6.0,"fn":5.0,"tn":77.0,"sample_size":111.0,"observed_prevalence":0.25225225225225223,"sensitivity":0.8214285714285714,"specificity":0.927710843373494,"ppv_observed":0.7931034482758621,"npv_observed":0.9390243902439024,"youden_j":0.7491394148020654,"lr_positive":11.363095238095235,"lr_negative":0.19248608534322822,"diagnostic_odds_ratio":59.03333333333333,"baseline_entropy_bits_observed":0.8148283832923792,"conditional_entropy_bits_observed":0.43690819041261264,"information_bits_observed":0.3779201928797665,"information_fraction_observed":0.46380342244921535,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a7d0ec8c466a"},{"id":"diagnostics-2024:504:01f560c0b990","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Contrast enema","test_or_feature":"Contrast enema","target_condition":"Hirschsprung's disease","citation":"De Lorijn F, Reitsma JB, Voskuijl WP, et al. Diagnosis of Hirschsprung's disease: a prospective, comparative accuracy study of common tests. J Pediatr. 2005;146(6):787-792. doi:10.1016/j.jpeds.2005.01.045","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"504","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":504,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.75,"specificity":0.98},"tp":21.0,"fp":2.0,"fn":7.0,"tn":81.0,"sample_size":111.0,"observed_prevalence":0.25225225225225223,"sensitivity":0.75,"specificity":0.9759036144578314,"ppv_observed":0.9130434782608695,"npv_observed":0.9204545454545454,"youden_j":0.7259036144578315,"lr_positive":31.125000000000043,"lr_negative":0.2561728395061728,"diagnostic_odds_ratio":121.5,"baseline_entropy_bits_observed":0.8148283832923792,"conditional_entropy_bits_observed":0.40589105281965465,"information_bits_observed":0.4089373304727245,"information_fraction_observed":0.5018692756140631,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"caea2f2e28ac"},{"id":"diagnostics-2024:505:8b23b88f67e4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rectal suction biopsy","test_or_feature":"Rectal suction biopsy","target_condition":"Hirschsprung's disease","citation":"De Lorijn F, Reitsma JB, Voskuijl WP, et al. Diagnosis of Hirschsprung's disease: a prospective, comparative accuracy study of common tests. J Pediatr. 2005;146(6):787-792. doi:10.1016/j.jpeds.2005.01.044","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"505","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":505,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.93,"specificity":1.0},"tp":26.0,"fp":0.0,"fn":2.0,"tn":83.0,"sample_size":111.0,"observed_prevalence":0.25225225225225223,"sensitivity":0.9285714285714286,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9764705882352941,"youden_j":0.9285714285714286,"lr_positive":null,"lr_negative":0.0714285714285714,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8148283832923792,"conditional_entropy_bits_observed":0.12315276369288194,"information_bits_observed":0.6916756195994972,"information_fraction_observed":0.8488604886402294,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7f5a3c51d9d6"},{"id":"diagnostics-2024:506:8685844c0b44","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"RNA assay","test_or_feature":"RNA assay","target_condition":"HIV","citation":"Daar ES, Little S, Pitt J, et al. Diagnosis of primary HIV-1 infection. Los Angeles County Primary HIV Infection Recruitment Network. Ann Intern Med. 2001;134(1):25-29. doi:10.7326/0003-4819-134-1-200101020-00011","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"506","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":506,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2001,"source_reported":{"sensitivity":1.0,"specificity":0.97},"tp":54.0,"fp":10.0,"fn":0.0,"tn":372.0,"sample_size":436.0,"observed_prevalence":0.12385321100917432,"sensitivity":1.0,"specificity":0.9738219895287958,"ppv_observed":0.84375,"npv_observed":1.0,"youden_j":0.9738219895287958,"lr_positive":38.20000000000004,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.5403363031565519,"conditional_entropy_bits_observed":0.09178163746398872,"information_bits_observed":0.4485546656925632,"information_fraction_observed":0.830139790852815,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ef537c272eaf"},{"id":"diagnostics-2024:507:672514ddb9a8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"p24 antigen assay","test_or_feature":"p24 antigen assay","target_condition":"HIV","citation":"Daar ES, Little S, Pitt J, et al. Diagnosis of primary HIV-1 infection. Los Angeles County Primary HIV Infection Recruitment Network. Ann Intern Med. 2001;134(1):25-29. doi:10.7326/0003-4819-134-1-200101020-00010","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"507","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":507,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2001,"source_reported":{"sensitivity":0.89,"specificity":1.0},"tp":48.0,"fp":0.0,"fn":6.0,"tn":382.0,"sample_size":436.0,"observed_prevalence":0.12385321100917432,"sensitivity":0.8888888888888888,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9845360824742269,"youden_j":0.8888888888888888,"lr_positive":null,"lr_negative":0.11111111111111116,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.5403363031565519,"conditional_entropy_bits_observed":0.1024738427858316,"information_bits_observed":0.4378624603707203,"information_fraction_observed":0.810351734304734,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2c344d28bb7b"},{"id":"diagnostics-2024:508:4a9ced609dd9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fecal immunochemical test","test_or_feature":"Fecal immunochemical test","target_condition":"Colon cancer screening","citation":"D'Souza N, Georgiou Delisle T, Chen M The NICE FIT Steering Group, et alFaecal immunochemical test is superior to symptoms in predicting pathology in patients with suspected colorectal cancer symptoms referred on a 2WW pathway: a diagnostic accuracy studyGut 2021;70:1130-1138.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"508","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":508,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.31,"specificity":0.99},"tp":233.0,"fp":96.0,"fn":516.0,"tn":8977.0,"sample_size":9822.0,"observed_prevalence":0.07625738138871921,"sensitivity":0.31108144192256343,"specificity":0.9894191557368015,"ppv_observed":0.7082066869300911,"npv_observed":0.9456441588538923,"youden_j":0.3005005976593649,"lr_positive":29.40043669336895,"lr_negative":0.696285850221297,"diagnostic_odds_ratio":42.224664890180875,"baseline_entropy_bits_observed":0.38885255618858694,"conditional_entropy_bits_observed":0.3235922124699077,"information_bits_observed":0.06526034371867923,"information_fraction_observed":0.16782799207581667,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bd4781ae46ad"},{"id":"diagnostics-2024:509:c9d3c5b7f9ee","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"Serious bacterial infection","citation":"Craig JC, Williams GJ, Jones M, et al. The accuracy of clinical symptoms and signs for the diagnosis of serious bacterial infection in young febrile children: prospective cohort study of 15 781 febrile illnesses. BMJ. 2010;340:c1594. Published 2010 Apr 20. doi:10.1136/bmj.c1594","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"509","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":509,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.5,"specificity":0.9},"tp":570.0,"fp":1464.0,"fn":570.0,"tn":13177.0,"sample_size":15781.0,"observed_prevalence":0.0722387681389012,"sensitivity":0.5,"specificity":0.9000068301345536,"ppv_observed":0.28023598820059,"npv_observed":0.9585364079435513,"youden_j":0.4000068301345536,"lr_positive":5.000341530054643,"lr_negative":0.5555513394551111,"diagnostic_odds_ratio":9.00068306010929,"baseline_entropy_bits_observed":0.37422329648808517,"conditional_entropy_bits_observed":0.3271740651541588,"information_bits_observed":0.047049231333926356,"information_fraction_observed":0.12572501972876066,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"30dd8a51c857"},{"id":"diagnostics-2024:510:688a477118d1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pain during kneeling","test_or_feature":"Pain during kneeling","target_condition":"Patellofemoral pain syndrome","citation":"Cook C, Hegedus E, Hawkins R, Scovell F, Wyland D. Diagnostic accuracy and association to disability of clinical test findings associated with patellofemoral pain syndrome. Physiother Can. 2010;62(1):17-24. doi:10.3138/physio.62.1.22","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"510","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":510,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.85,"specificity":0.5},"tp":44.0,"fp":12.0,"fn":8.0,"tn":12.0,"sample_size":76.0,"observed_prevalence":0.6842105263157895,"sensitivity":0.8461538461538461,"specificity":0.5,"ppv_observed":0.7857142857142857,"npv_observed":0.6,"youden_j":0.34615384615384626,"lr_positive":1.6923076923076923,"lr_negative":0.3076923076923077,"diagnostic_odds_ratio":5.5,"baseline_entropy_bits_observed":0.8997437586982626,"conditional_entropy_bits_observed":0.8078466617845295,"information_bits_observed":0.09189709691373316,"information_fraction_observed":0.1021369651362613,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6bcd6bdf1dfc"},{"id":"diagnostics-2024:511:b546dcb75df3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pain during stair climbing","test_or_feature":"Pain during stair climbing","target_condition":"Patellofemoral pain syndrome","citation":"Cook C, Hegedus E, Hawkins R, Scovell F, Wyland D. Diagnostic accuracy and association to disability of clinical test findings associated with patellofemoral pain syndrome. Physiother Can. 2010;62(1):17-24. doi:10.3138/physio.62.1.21","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"511","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":511,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.75,"specificity":0.42},"tp":39.0,"fp":14.0,"fn":13.0,"tn":10.0,"sample_size":76.0,"observed_prevalence":0.6842105263157895,"sensitivity":0.75,"specificity":0.4166666666666667,"ppv_observed":0.7358490566037735,"npv_observed":0.43478260869565216,"youden_j":0.16666666666666674,"lr_positive":1.2857142857142858,"lr_negative":0.6,"diagnostic_odds_ratio":2.142857142857143,"baseline_entropy_bits_observed":0.8997437586982626,"conditional_entropy_bits_observed":0.8797770572634065,"information_bits_observed":0.019966701434856127,"information_fraction_observed":0.022191542027191927,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7216cb80e313"},{"id":"diagnostics-2024:512:68d3f47e5be5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pain during squatting","test_or_feature":"Pain during squatting","target_condition":"Patellofemoral pain syndrome","citation":"Cook C, Hegedus E, Hawkins R, Scovell F, Wyland D. Diagnostic accuracy and association to disability of clinical test findings associated with patellofemoral pain syndrome. Physiother Can. 2010;62(1):17-24. doi:10.3138/physio.62.1.20","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"512","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":512,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.9,"specificity":0.5},"tp":47.0,"fp":12.0,"fn":5.0,"tn":12.0,"sample_size":76.0,"observed_prevalence":0.6842105263157895,"sensitivity":0.9038461538461539,"specificity":0.5,"ppv_observed":0.7966101694915254,"npv_observed":0.7058823529411765,"youden_j":0.40384615384615374,"lr_positive":1.8076923076923077,"lr_negative":0.1923076923076923,"diagnostic_odds_ratio":9.4,"baseline_entropy_bits_observed":0.8997437586982626,"conditional_entropy_bits_observed":0.7611630485922485,"information_bits_observed":0.13858071010601414,"information_fraction_observed":0.1540224189012557,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5e784ed216fa"},{"id":"diagnostics-2024:513:61e70610eafa","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pain during resisted msucle contraction","test_or_feature":"Pain during resisted msucle contraction","target_condition":"Patellofemoral pain syndrome","citation":"Cook C, Hegedus E, Hawkins R, Scovell F, Wyland D. Diagnostic accuracy and association to disability of clinical test findings associated with patellofemoral pain syndrome. Physiother Can. 2010;62(1):17-24. doi:10.3138/physio.62.1.19","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"513","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":513,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.38,"specificity":0.83},"tp":20.0,"fp":4.0,"fn":32.0,"tn":20.0,"sample_size":76.0,"observed_prevalence":0.6842105263157895,"sensitivity":0.38461538461538464,"specificity":0.8333333333333334,"ppv_observed":0.8333333333333334,"npv_observed":0.38461538461538464,"youden_j":0.21794871794871806,"lr_positive":2.3076923076923084,"lr_negative":0.7384615384615385,"diagnostic_odds_ratio":3.125,"baseline_entropy_bits_observed":0.8997437586982626,"conditional_entropy_bits_observed":0.8629584416467111,"information_bits_observed":0.036785317051551525,"information_fraction_observed":0.040884214751066496,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"16d6957633ce"},{"id":"diagnostics-2024:514:99c158e80d92","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pain during palpation","test_or_feature":"Pain during palpation","target_condition":"Patellofemoral pain syndrome","citation":"Cook C, Hegedus E, Hawkins R, Scovell F, Wyland D. Diagnostic accuracy and association to disability of clinical test findings associated with patellofemoral pain syndrome. Physiother Can. 2010;62(1):17-24. doi:10.3138/physio.62.1.18","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"514","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":514,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.46,"specificity":0.67},"tp":24.0,"fp":8.0,"fn":28.0,"tn":16.0,"sample_size":76.0,"observed_prevalence":0.6842105263157895,"sensitivity":0.46153846153846156,"specificity":0.6666666666666666,"ppv_observed":0.75,"npv_observed":0.36363636363636365,"youden_j":0.1282051282051282,"lr_positive":1.3846153846153846,"lr_negative":0.8076923076923077,"diagnostic_odds_ratio":1.7142857142857142,"baseline_entropy_bits_observed":0.8997437586982626,"conditional_entropy_bits_observed":0.8890783340147423,"information_bits_observed":0.010665424683520275,"information_fraction_observed":0.011853846809619296,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"965317c8a785"},{"id":"diagnostics-2024:515:612015ba20e6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pain during manual compression","test_or_feature":"Pain during manual compression","target_condition":"Patellofemoral pain syndrome","citation":"Cook C, Hegedus E, Hawkins R, Scovell F, Wyland D. Diagnostic accuracy and association to disability of clinical test findings associated with patellofemoral pain syndrome. Physiother Can. 2010;62(1):17-24. doi:10.3138/physio.62.1.17","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"515","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":515,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.67,"specificity":0.54},"tp":35.0,"fp":11.0,"fn":17.0,"tn":13.0,"sample_size":76.0,"observed_prevalence":0.6842105263157895,"sensitivity":0.6730769230769231,"specificity":0.5416666666666666,"ppv_observed":0.7608695652173914,"npv_observed":0.43333333333333335,"youden_j":0.21474358974358987,"lr_positive":1.4685314685314685,"lr_negative":0.6035502958579881,"diagnostic_odds_ratio":2.4331550802139037,"baseline_entropy_bits_observed":0.8997437586982626,"conditional_entropy_bits_observed":0.8699911817329484,"information_bits_observed":0.029752576965314192,"information_fraction_observed":0.03306783367784604,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"488f8c215eb7"},{"id":"diagnostics-2024:516:dfb45742567f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Sepsis-3 criteria","test_or_feature":"Sepsis-3 criteria","target_condition":"Mortality in sepsis","citation":"Chen, Q. H., Shao, J., Liu, W. L., Wang, H. L., Liu, L., Gu, X. H., & Zheng, R. Q. (2019). Predictive accuracy of Sepsis-3 definitions for mortality among adult critically ill patients with suspected infection. Chinese medical journal, 132(10), 1147–1153. https://doi.org/10.1097/CM9.0000000000000166","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"516","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":516,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.73,"specificity":0.69},"tp":147.0,"fp":87.0,"fn":55.0,"tn":194.0,"sample_size":483.0,"observed_prevalence":0.41821946169772256,"sensitivity":0.7277227722772277,"specificity":0.6903914590747331,"ppv_observed":0.6282051282051282,"npv_observed":0.7791164658634538,"youden_j":0.4181142313519608,"lr_positive":2.3504609081597816,"lr_negative":0.3943809329386547,"diagnostic_odds_ratio":5.9598746081504705,"baseline_entropy_bits_observed":0.9806153715936556,"conditional_entropy_bits_observed":0.8539545155476704,"information_bits_observed":0.1266608560459852,"information_fraction_observed":0.12916466508182634,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"541109a5d956"},{"id":"diagnostics-2024:517:d7689a705467","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Sepsis-1 criteria","test_or_feature":"Sepsis-1 criteria","target_condition":"Mortality in sepsis","citation":"Chen, Q. H., Shao, J., Liu, W. L., Wang, H. L., Liu, L., Gu, X. H., & Zheng, R. Q. (2019). Predictive accuracy of Sepsis-3 definitions for mortality among adult critically ill patients with suspected infection. Chinese medical journal, 132(10), 1147–1153. https://doi.org/10.1097/CM9.0000000000000166","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"517","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":517,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2019,"source_reported":{"sensitivity":0.63,"specificity":0.58},"tp":130.0,"fp":185.0,"fn":75.0,"tn":254.0,"sample_size":644.0,"observed_prevalence":0.31832298136645965,"sensitivity":0.6341463414634146,"specificity":0.5785876993166287,"ppv_observed":0.4126984126984127,"npv_observed":0.7720364741641338,"youden_j":0.21273404078004332,"lr_positive":1.504812129202373,"lr_negative":0.6323218743998463,"diagnostic_odds_ratio":2.37981981981982,"baseline_entropy_bits_observed":0.9025484304987185,"conditional_entropy_bits_observed":0.8739585857676231,"information_bits_observed":0.028589844731095382,"information_fraction_observed":0.03167679845756042,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2242ff9dee1f"},{"id":"diagnostics-2024:518:81362994b126","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRCP","test_or_feature":"MRCP","target_condition":"Choledocholithiasis","citation":"Chen W, Mo JJ, Lin L, Li CQ, Zhang JF. Diagnostic value of magnetic resonance cholangiopancreatography in choledocholithiasis. World J Gastroenterol. 2015;21(11):3351-3360. doi:10.3748/wjg.v21.i11.3351","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"518","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":518,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2015,"source_reported":{"sensitivity":0.9,"specificity":0.95},"tp":664.0,"fp":85.0,"fn":74.0,"tn":1497.0,"sample_size":2320.0,"observed_prevalence":0.31810344827586207,"sensitivity":0.8997289972899729,"specificity":0.9462705436156763,"ppv_observed":0.8865153538050734,"npv_observed":0.9528962444302992,"youden_j":0.8459995409056491,"lr_positive":16.74554439662042,"lr_negative":0.10596441301754367,"diagnostic_odds_ratio":158.02988871224164,"baseline_entropy_bits_observed":0.9023070918647063,"conditional_entropy_bits_observed":0.350276229655488,"information_bits_observed":0.5520308622092183,"information_fraction_observed":0.6117993166477194,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"78083c1d408f"},{"id":"diagnostics-2024:519:d3fc5dddd6d6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Base deficit","test_or_feature":"Base deficit","target_condition":"Hyperlactatemia","citation":"Chawla LS, Jagasia D, Abell LM, et al. Anion gap, anion gap corrected for albumin, and base deficit fail to accurately diagnose clinically significant hyperlactatemia in critically ill patients. J Intensive Care Med. 2008;23(2):122-127. doi:10.1177/0885066607312987","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"519","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":519,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.65,"specificity":0.53},"tp":185.0,"fp":516.0,"fn":101.0,"tn":579.0,"sample_size":1381.0,"observed_prevalence":0.20709630702389573,"sensitivity":0.6468531468531469,"specificity":0.5287671232876713,"ppv_observed":0.26390870185449355,"npv_observed":0.8514705882352941,"youden_j":0.17562027014081805,"lr_positive":1.3726825500081317,"lr_negative":0.6678684010290227,"diagnostic_odds_ratio":2.0553189039834217,"baseline_entropy_bits_observed":0.7358956516993499,"conditional_entropy_bits_observed":0.721089387956168,"information_bits_observed":0.014806263743181947,"information_fraction_observed":0.020120058746088427,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"04d9d0906199"},{"id":"diagnostics-2024:520:20cf14111e34","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Albumin-corrected anion gap","test_or_feature":"Albumin-corrected anion gap","target_condition":"Hyperlactatemia","citation":"Chawla LS, Jagasia D, Abell LM, et al. Anion gap, anion gap corrected for albumin, and base deficit fail to accurately diagnose clinically significant hyperlactatemia in critically ill patients. J Intensive Care Med. 2008;23(2):122-127. doi:10.1177/0885066607312986","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"520","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":520,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.32,"specificity":0.8},"tp":92.0,"fp":222.0,"fn":194.0,"tn":873.0,"sample_size":1381.0,"observed_prevalence":0.20709630702389573,"sensitivity":0.32167832167832167,"specificity":0.7972602739726027,"ppv_observed":0.2929936305732484,"npv_observed":0.8181818181818182,"youden_j":0.11893859565092435,"lr_positive":1.5866565866565863,"lr_negative":0.8508158508158509,"diagnostic_odds_ratio":1.864864864864865,"baseline_entropy_bits_observed":0.7358956516993499,"conditional_entropy_bits_observed":0.7269021750122083,"information_bits_observed":0.008993476687141566,"information_fraction_observed":0.012221130355062691,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b233182712c5"},{"id":"diagnostics-2024:521:f4d5696d88cd","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Anion gap","test_or_feature":"Anion gap","target_condition":"Hyperlactatemia","citation":"Chawla LS, Jagasia D, Abell LM, et al. Anion gap, anion gap corrected for albumin, and base deficit fail to accurately diagnose clinically significant hyperlactatemia in critically ill patients. J Intensive Care Med. 2008;23(2):122-127. doi:10.1177/0885066607312985","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"521","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":521,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2008,"source_reported":{"sensitivity":0.14,"specificity":0.94},"tp":41.0,"fp":71.0,"fn":245.0,"tn":1024.0,"sample_size":1381.0,"observed_prevalence":0.20709630702389573,"sensitivity":0.14335664335664336,"specificity":0.9351598173515981,"ppv_observed":0.36607142857142855,"npv_observed":0.8069345941686368,"youden_j":0.07851646070824159,"lr_positive":2.2109228799369633,"lr_negative":0.9160395268793707,"diagnostic_odds_ratio":2.41356711698764,"baseline_entropy_bits_observed":0.7358956516993499,"conditional_entropy_bits_observed":0.7272854971506237,"information_bits_observed":0.008610154548726157,"information_fraction_observed":0.011700238381410948,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"98d43aafaed1"},{"id":"diagnostics-2024:522:b8164753d8ce","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Placental growth factor concentration, 37+ weeks","test_or_feature":"Placental growth factor concentration, 37+ weeks","target_condition":"Pre-eclampsia","citation":"Chappell LC, Duckworth S, Seed PT, et al. Diagnostic accuracy of placental growth factor in women with suspected preeclampsia: a prospective multicenter study. Circulation. 2013;128(19):2121-2131. doi:10.1161/CIRCULATIONAHA.113.003216","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"522","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":522,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.57,"specificity":0.77},"tp":49.0,"fp":27.0,"fn":37.0,"tn":88.0,"sample_size":201.0,"observed_prevalence":0.42786069651741293,"sensitivity":0.5697674418604651,"specificity":0.7652173913043478,"ppv_observed":0.6447368421052632,"npv_observed":0.704,"youden_j":0.3349848331648131,"lr_positive":2.4267872523686482,"lr_negative":0.5622357293868921,"diagnostic_odds_ratio":4.316316316316317,"baseline_entropy_bits_observed":0.9849316674824931,"conditional_entropy_bits_observed":0.8999155458510508,"information_bits_observed":0.08501612163144223,"information_fraction_observed":0.08631677144541947,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"dfda1807f9b9"},{"id":"diagnostics-2024:523:4da60fa14960","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Placental growth factor concentration, 35-36 weeks","test_or_feature":"Placental growth factor concentration, 35-36 weeks","target_condition":"Pre-eclampsia","citation":"Chappell LC, Duckworth S, Seed PT, et al. Diagnostic accuracy of placental growth factor in women with suspected preeclampsia: a prospective multicenter study. Circulation. 2013;128(19):2121-2131. doi:10.1161/CIRCULATIONAHA.113.003215","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"523","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":523,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2013,"source_reported":{"sensitivity":0.7,"specificity":0.64},"tp":47.0,"fp":25.0,"fn":20.0,"tn":45.0,"sample_size":137.0,"observed_prevalence":0.48905109489051096,"sensitivity":0.7014925373134329,"specificity":0.6428571428571429,"ppv_observed":0.6527777777777778,"npv_observed":0.6923076923076923,"youden_j":0.34434968017057566,"lr_positive":1.9641791044776122,"lr_negative":0.4643449419568822,"diagnostic_odds_ratio":4.23,"baseline_entropy_bits_observed":0.9996540760494435,"conditional_entropy_bits_observed":0.9120764667510683,"information_bits_observed":0.0875776092983751,"information_fraction_observed":0.08760791497442308,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1ec5631e9304"},{"id":"diagnostics-2024:524:aecd25f3a7fd","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CCTA","test_or_feature":"CCTA","target_condition":"Aortic stenosis","citation":"Chaikriangkrai, K et al. Diagnostic Accuracy of Coronary Computed Tomography Before Aortic Valve Replacement: Systematic Review and Meta-Analysis. Journal of Thoracic Imaging. 2018;33(4):207-216. doi: 10.1097/RTI.0000000000000322","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"524","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":524,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.95,"specificity":0.79},"tp":612.0,"fp":180.0,"fn":32.0,"tn":674.0,"sample_size":1498.0,"observed_prevalence":0.42990654205607476,"sensitivity":0.9503105590062112,"specificity":0.7892271662763466,"ppv_observed":0.7727272727272727,"npv_observed":0.9546742209631728,"youden_j":0.7395377252825579,"lr_positive":4.5086956521739125,"lr_negative":0.06295961811379175,"diagnostic_odds_ratio":71.6125,"baseline_entropy_bits_observed":0.9857770091118137,"conditional_entropy_bits_observed":0.534267096828229,"information_bits_observed":0.4515099122835846,"information_fraction_observed":0.4580243889948251,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"96a6364549a6","condition_context_id":"condition:aortic_stenosis"},{"id":"diagnostics-2024:525:7430c26e7201","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ultrasonographic abdominal examination","test_or_feature":"Ultrasonographic abdominal examination","target_condition":"Splenomegaly","citation":"Cessford, T., Meneilly, G.S., Arishenkoff, S., Eddy, C., Chen, L.Y.C., Kim, D.J. and Ma, I.W.Y. (2018), Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly. J Ultrasound Med, 37: 1621-1629. https://doi.org/10.1002/jum.14509","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"525","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":525,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.58,"specificity":1.0},"tp":7.0,"fp":0.0,"fn":5.0,"tn":7.0,"sample_size":19.0,"observed_prevalence":0.631578947368421,"sensitivity":0.5833333333333334,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.5833333333333334,"youden_j":0.5833333333333335,"lr_positive":null,"lr_negative":0.41666666666666663,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9494520153879484,"conditional_entropy_bits_observed":0.6188644778849386,"information_bits_observed":0.33058753750300984,"information_fraction_observed":0.34818772528270525,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"870fbe53cc81"},{"id":"diagnostics-2024:526:b1d788b775cf","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal examination","test_or_feature":"Abdominal examination","target_condition":"Splenomegaly","citation":"Cessford, T., Meneilly, G.S., Arishenkoff, S., Eddy, C., Chen, L.Y.C., Kim, D.J. and Ma, I.W.Y. (2018), Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly. J Ultrasound Med, 37: 1621-1629. https://doi.org/10.1002/jum.14508","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"526","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":526,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.33,"specificity":0.14},"tp":4.0,"fp":6.0,"fn":8.0,"tn":1.0,"sample_size":19.0,"observed_prevalence":0.631578947368421,"sensitivity":0.3333333333333333,"specificity":0.14285714285714285,"ppv_observed":0.4,"npv_observed":0.1111111111111111,"youden_j":-0.5238095238095238,"lr_positive":0.38888888888888884,"lr_negative":4.666666666666668,"diagnostic_odds_ratio":0.08333333333333333,"baseline_entropy_bits_observed":0.9494520153879484,"conditional_entropy_bits_observed":0.749412155659342,"information_bits_observed":0.20003985972860638,"information_fraction_observed":0.21068980473633478,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5c93aef6f9ff"},{"id":"diagnostics-2024:527:386fe119c2eb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ultrasonographic Castell's method","test_or_feature":"Ultrasonographic Castell's method","target_condition":"Splenomegaly","citation":"Cessford, T., Meneilly, G.S., Arishenkoff, S., Eddy, C., Chen, L.Y.C., Kim, D.J. and Ma, I.W.Y. (2018), Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly. J Ultrasound Med, 37: 1621-1629. https://doi.org/10.1002/jum.14507","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"527","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":527,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.92,"specificity":0.86},"tp":11.0,"fp":1.0,"fn":1.0,"tn":6.0,"sample_size":19.0,"observed_prevalence":0.631578947368421,"sensitivity":0.9166666666666666,"specificity":0.8571428571428571,"ppv_observed":0.9166666666666666,"npv_observed":0.8571428571428571,"youden_j":0.7738095238095237,"lr_positive":6.416666666666664,"lr_negative":0.09722222222222227,"diagnostic_odds_ratio":66.0,"baseline_entropy_bits_observed":0.9494520153879484,"conditional_entropy_bits_observed":0.47934271861683664,"information_bits_observed":0.4701092967711118,"information_fraction_observed":0.49513749947544633,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cdbf7d94611a"},{"id":"diagnostics-2024:528:b3e4beffea33","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Castell's method","test_or_feature":"Castell's method","target_condition":"Splenomegaly","citation":"Cessford, T., Meneilly, G.S., Arishenkoff, S., Eddy, C., Chen, L.Y.C., Kim, D.J. and Ma, I.W.Y. (2018), Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly. J Ultrasound Med, 37: 1621-1629. https://doi.org/10.1002/jum.14506","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"528","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":528,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.83,"specificity":0.71},"tp":10.0,"fp":2.0,"fn":2.0,"tn":5.0,"sample_size":19.0,"observed_prevalence":0.631578947368421,"sensitivity":0.8333333333333334,"specificity":0.7142857142857143,"ppv_observed":0.8333333333333334,"npv_observed":0.7142857142857143,"youden_j":0.5476190476190477,"lr_positive":2.916666666666667,"lr_negative":0.23333333333333328,"diagnostic_odds_ratio":12.5,"baseline_entropy_bits_observed":0.9494520153879484,"conditional_entropy_bits_observed":0.7285322652498245,"information_bits_observed":0.22091975013812393,"information_fraction_observed":0.23268132202326788,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b8793e090c72"},{"id":"diagnostics-2024:529:182b15148226","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Duke criteria","test_or_feature":"Duke criteria","target_condition":"Infective endocarditis","citation":"Cecchi E, Parrini I, Chinaglia A, et al. New diagnostic criteria for infective endocarditis. A study of sensitivity and specificity. Eur Heart J. 1997;18(7):1149-1156. doi:10.1093/oxfordjournals.eurheartj.a015411","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"529","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":529,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.75,"specificity":0.97},"tp":52.0,"fp":2.0,"fn":17.0,"tn":72.0,"sample_size":143.0,"observed_prevalence":0.4825174825174825,"sensitivity":0.7536231884057971,"specificity":0.972972972972973,"ppv_observed":0.9629629629629629,"npv_observed":0.8089887640449438,"youden_j":0.7265961613787701,"lr_positive":27.88405797101455,"lr_negative":0.25322061191626405,"diagnostic_odds_ratio":110.11764705882354,"baseline_entropy_bits_observed":0.9991179341613547,"conditional_entropy_bits_observed":0.5241948721985852,"information_bits_observed":0.47492306196276957,"information_fraction_observed":0.4753423452071383,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"661189d81c0e","condition_context_id":"condition:endocarditis"},{"id":"diagnostics-2024:530:442d1dda9cbe","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Von Reyn criteria","test_or_feature":"Von Reyn criteria","target_condition":"Infective endocarditis","citation":"Cecchi E, Parrini I, Chinaglia A, et al. New diagnostic criteria for infective endocarditis. A study of sensitivity and specificity. Eur Heart J. 1997;18(7):1149-1156. doi:10.1093/oxfordjournals.eurheartj.a015411","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"530","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":530,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.51,"specificity":0.99},"tp":35.0,"fp":1.0,"fn":34.0,"tn":73.0,"sample_size":143.0,"observed_prevalence":0.4825174825174825,"sensitivity":0.5072463768115942,"specificity":0.9864864864864865,"ppv_observed":0.9722222222222222,"npv_observed":0.6822429906542056,"youden_j":0.49373286329808064,"lr_positive":37.53623188405805,"lr_negative":0.4995036728211236,"diagnostic_odds_ratio":75.1470588235294,"baseline_entropy_bits_observed":0.9991179341613547,"conditional_entropy_bits_observed":0.7209680601609745,"information_bits_observed":0.27814987400038027,"information_fraction_observed":0.27839543710508535,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"69d8a541e2bd","condition_context_id":"condition:endocarditis"},{"id":"diagnostics-2024:531:acca48cca87c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"IgA against transglutaminase","test_or_feature":"IgA against transglutaminase","target_condition":"Celiac disease","citation":"Catassi GN, Pulvirenti A, Monachesi C, Catassi C, Lionetti E. Diagnostic Accuracy of IgA Anti-Transglutaminase and IgG Anti-Deamidated Gliadin for Diagnosis of Celiac Disease in Children under Two Years of Age: A Systematic Review and Meta-Analysis. Nutrients. 2021;14(1):7. Published 2021 Dec 21. doi:10.3390/nu14010008","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"531","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":531,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.94,"specificity":1.0},"tp":233.0,"fp":2.0,"fn":14.0,"tn":5647.0,"sample_size":5896.0,"observed_prevalence":0.04189280868385346,"sensitivity":0.9433198380566802,"specificity":0.9996459550362896,"ppv_observed":0.9914893617021276,"npv_observed":0.9975269387034092,"youden_j":0.9429657930929698,"lr_positive":2664.4068825911245,"lr_negative":0.05670023637645009,"diagnostic_odds_ratio":46991.107142857145,"baseline_entropy_bits_observed":0.25090433800263384,"conditional_entropy_bits_observed":0.026803197691954942,"information_bits_observed":0.2241011403106789,"information_fraction_observed":0.8931736377883049,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"644e06288aa5"},{"id":"diagnostics-2024:532:45c429b0759a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"IgG against deamidated gliadin peptides","test_or_feature":"IgG against deamidated gliadin peptides","target_condition":"Celiac disease","citation":"Catassi GN, Pulvirenti A, Monachesi C, Catassi C, Lionetti E. Diagnostic Accuracy of IgA Anti-Transglutaminase and IgG Anti-Deamidated Gliadin for Diagnosis of Celiac Disease in Children under Two Years of Age: A Systematic Review and Meta-Analysis. Nutrients. 2021;14(1):7. Published 2021 Dec 21. doi:10.3390/nu14010007","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"532","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":532,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.98,"specificity":0.98},"tp":241.0,"fp":88.0,"fn":6.0,"tn":5521.0,"sample_size":5856.0,"observed_prevalence":0.04217896174863388,"sensitivity":0.9757085020242915,"specificity":0.9843109288643251,"ppv_observed":0.7325227963525835,"npv_observed":0.9989144201194138,"youden_j":0.9600194308886167,"lr_positive":62.19032940743447,"lr_negative":0.024678683598215727,"diagnostic_odds_ratio":2520.001893939394,"baseline_entropy_bits_observed":0.25219496874364844,"conditional_entropy_bits_observed":0.058637050807451636,"information_bits_observed":0.1935579179361968,"information_fraction_observed":0.7674931776015916,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fca414557bc2"},{"id":"diagnostics-2024:533:97f12598692e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Fractional excretion of urea","test_or_feature":"Fractional excretion of urea","target_condition":"Prerenal kidney failure","citation":"Carvounis CP, Nisar S, Guro-Razuman S. Significance of the fractional excretion of urea in the differential diagnosis of acute renal failure. Kidney Int. 2002;62(6):2223-2229. doi:10.1046/j.1523-1755.2002.00683.x","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"533","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":533,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.89,"specificity":0.96},"tp":24.0,"fp":3.0,"fn":3.0,"tn":72.0,"sample_size":102.0,"observed_prevalence":0.2647058823529412,"sensitivity":0.8888888888888888,"specificity":0.96,"ppv_observed":0.8888888888888888,"npv_observed":0.96,"youden_j":0.8488888888888888,"lr_positive":22.2222222222222,"lr_negative":0.1157407407407408,"diagnostic_odds_ratio":192.0,"baseline_entropy_bits_observed":0.833764907210665,"conditional_entropy_bits_observed":0.31137146294238777,"information_bits_observed":0.5223934442682772,"information_fraction_observed":0.6265476512029373,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"686b25360fd7"},{"id":"diagnostics-2024:534:e29978700f1d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CSF PCR assay","test_or_feature":"CSF PCR assay","target_condition":"Neurocysticercosis","citation":"Carpio A, Campoverde A, Romo ML, et al. Validity of a PCR assay in CSF for the diagnosis of neurocysticercosis. Neurol Neuroimmunol Neuroinflamm. 2017;4(2):e324. Published 2017 Jan 16. doi:10.1212/NXI.0000000000000324","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"534","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":534,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.72,"specificity":1.0},"tp":26.0,"fp":0.0,"fn":10.0,"tn":36.0,"sample_size":72.0,"observed_prevalence":0.5,"sensitivity":0.7222222222222222,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.782608695652174,"youden_j":0.7222222222222223,"lr_positive":null,"lr_negative":0.2777777777777778,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":1.0,"conditional_entropy_bits_observed":0.4826009580253572,"information_bits_observed":0.5173990419746428,"information_fraction_observed":0.5173990419746428,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7978b83832be"},{"id":"diagnostics-2024:535:333578d8cef8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Drop arm test","test_or_feature":"Drop arm test","target_condition":"Shoulder impingement syndrome","citation":"Çalış M, Akgün K, Birtane M, et alDiagnostic values of clinical diagnostic tests in subacromial impingement syndromeAnnals of the Rheumatic Diseases 2000;59:44-47. doi: http://dx.doi.org/10.1136/ard.59.1.50","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"535","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":535,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.08,"specificity":0.97},"tp":7.0,"fp":1.0,"fn":79.0,"tn":33.0,"sample_size":120.0,"observed_prevalence":0.7166666666666667,"sensitivity":0.08139534883720931,"specificity":0.9705882352941176,"ppv_observed":0.875,"npv_observed":0.29464285714285715,"youden_j":0.051983584131326976,"lr_positive":2.767441860465116,"lr_negative":0.9464411557434813,"diagnostic_odds_ratio":2.9240506329113924,"baseline_entropy_bits_observed":0.8599530497177521,"conditional_entropy_bits_observed":0.8525715147602361,"information_bits_observed":0.007381534957516034,"information_fraction_observed":0.008583648793313485,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d8624508fa35"},{"id":"diagnostics-2024:536:b0f9038a0ccc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Painful arc test","test_or_feature":"Painful arc test","target_condition":"Shoulder impingement syndrome","citation":"Çalış M, Akgün K, Birtane M, et alDiagnostic values of clinical diagnostic tests in subacromial impingement syndromeAnnals of the Rheumatic Diseases 2000;59:44-47. doi: http://dx.doi.org/10.1136/ard.59.1.49","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"536","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":536,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.33,"specificity":0.79},"tp":28.0,"fp":7.0,"fn":58.0,"tn":27.0,"sample_size":120.0,"observed_prevalence":0.7166666666666667,"sensitivity":0.32558139534883723,"specificity":0.7941176470588235,"ppv_observed":0.8,"npv_observed":0.3176470588235294,"youden_j":0.11969904240766072,"lr_positive":1.581395348837209,"lr_negative":0.8492678725236865,"diagnostic_odds_ratio":1.8620689655172413,"baseline_entropy_bits_observed":0.8599530497177521,"conditional_entropy_bits_observed":0.8493404384745792,"information_bits_observed":0.01061261124317292,"information_fraction_observed":0.012340919363744473,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"40b31d519f36"},{"id":"diagnostics-2024:537:5a22df87e807","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Yergason's test","test_or_feature":"Yergason's test","target_condition":"Shoulder impingement syndrome","citation":"Çalış M, Akgün K, Birtane M, et alDiagnostic values of clinical diagnostic tests in subacromial impingement syndromeAnnals of the Rheumatic Diseases 2000;59:44-47. doi: http://dx.doi.org/10.1136/ard.59.1.48","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"537","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":537,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.37,"specificity":0.85},"tp":32.0,"fp":5.0,"fn":54.0,"tn":29.0,"sample_size":120.0,"observed_prevalence":0.7166666666666667,"sensitivity":0.37209302325581395,"specificity":0.8529411764705882,"ppv_observed":0.8648648648648649,"npv_observed":0.3493975903614458,"youden_j":0.22503419972640204,"lr_positive":2.5302325581395344,"lr_negative":0.7361668003207699,"diagnostic_odds_ratio":3.437037037037037,"baseline_entropy_bits_observed":0.8599530497177521,"conditional_entropy_bits_observed":0.8218586073341849,"information_bits_observed":0.038094442383567184,"information_fraction_observed":0.04429828162836364,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fb945d0af8b2"},{"id":"diagnostics-2024:538:fb91bb166539","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Speed's test","test_or_feature":"Speed's test","target_condition":"Shoulder impingement syndrome","citation":"Çalış M, Akgün K, Birtane M, et alDiagnostic values of clinical diagnostic tests in subacromial impingement syndromeAnnals of the Rheumatic Diseases 2000;59:44-47. doi: http://dx.doi.org/10.1136/ard.59.1.47","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"538","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":538,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.69,"specificity":0.56},"tp":59.0,"fp":15.0,"fn":27.0,"tn":19.0,"sample_size":120.0,"observed_prevalence":0.7166666666666667,"sensitivity":0.686046511627907,"specificity":0.5588235294117647,"ppv_observed":0.7972972972972973,"npv_observed":0.41304347826086957,"youden_j":0.2448700410396718,"lr_positive":1.5550387596899224,"lr_negative":0.5618115055079559,"diagnostic_odds_ratio":2.7679012345679013,"baseline_entropy_bits_observed":0.8599530497177521,"conditional_entropy_bits_observed":0.8234292906237226,"information_bits_observed":0.036523759094029495,"information_fraction_observed":0.0424718059968705,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a70723c549ae"},{"id":"diagnostics-2024:539:95de39e28ef5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Horizontal adduction test","test_or_feature":"Horizontal adduction test","target_condition":"Shoulder impingement syndrome","citation":"Çalış M, Akgün K, Birtane M, et alDiagnostic values of clinical diagnostic tests in subacromial impingement syndromeAnnals of the Rheumatic Diseases 2000;59:44-47. doi: http://dx.doi.org/10.1136/ard.59.1.46","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"539","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":539,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.83,"specificity":0.26},"tp":71.0,"fp":25.0,"fn":15.0,"tn":9.0,"sample_size":120.0,"observed_prevalence":0.7166666666666667,"sensitivity":0.8255813953488372,"specificity":0.2647058823529412,"ppv_observed":0.7395833333333334,"npv_observed":0.375,"youden_j":0.09028727770177847,"lr_positive":1.1227906976744186,"lr_negative":0.6589147286821705,"diagnostic_odds_ratio":1.704,"baseline_entropy_bits_observed":0.8599530497177521,"conditional_entropy_bits_observed":0.8527863825852469,"information_bits_observed":0.0071666671325052445,"information_fraction_observed":0.008333788844469402,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6667277407a4"},{"id":"diagnostics-2024:540:475f85f3fd73","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Neer's test","test_or_feature":"Neer's test","target_condition":"Shoulder impingement syndrome","citation":"Çalış M, Akgün K, Birtane M, et alDiagnostic values of clinical diagnostic tests in subacromial impingement syndromeAnnals of the Rheumatic Diseases 2000;59:44-47. doi: http://dx.doi.org/10.1136/ard.59.1.45","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"540","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":540,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.88,"specificity":0.29},"tp":76.0,"fp":24.0,"fn":10.0,"tn":10.0,"sample_size":120.0,"observed_prevalence":0.7166666666666667,"sensitivity":0.8837209302325582,"specificity":0.29411764705882354,"ppv_observed":0.76,"npv_observed":0.5,"youden_j":0.17783857729138175,"lr_positive":1.2519379844961243,"lr_negative":0.39534883720930225,"diagnostic_odds_ratio":3.1666666666666665,"baseline_entropy_bits_observed":0.8599530497177521,"conditional_entropy_bits_observed":0.8292002328204352,"information_bits_observed":0.030752816897316904,"information_fraction_observed":0.03576104173060422,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8f1a6dec2623"},{"id":"diagnostics-2024:541:b6693adefe7a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Hawkins' test","test_or_feature":"Hawkins' test","target_condition":"Shoulder impingement syndrome","citation":"Çalış M, Akgün K, Birtane M, et alDiagnostic values of clinical diagnostic tests in subacromial impingement syndromeAnnals of the Rheumatic Diseases 2000;59:44-47. doi: http://dx.doi.org/10.1136/ard.59.1.44","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"541","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":541,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2000,"source_reported":{"sensitivity":0.92,"specificity":0.26},"tp":79.0,"fp":26.0,"fn":7.0,"tn":9.0,"sample_size":121.0,"observed_prevalence":0.7107438016528925,"sensitivity":0.9186046511627907,"specificity":0.2571428571428571,"ppv_observed":0.7523809523809524,"npv_observed":0.5625,"youden_j":0.17574750830564767,"lr_positive":1.2365831842576027,"lr_negative":0.31653746770025853,"diagnostic_odds_ratio":3.9065934065934065,"baseline_entropy_bits_observed":0.8677584893617496,"conditional_entropy_bits_observed":0.8314451083462752,"information_bits_observed":0.03631338101547443,"information_fraction_observed":0.041847335935812635,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e08999507514"},{"id":"diagnostics-2024:542:1bf5d01d225c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"CEH EUS","test_or_feature":"CEH EUS","target_condition":"Pancreatic cancer","citation":"Bunganič B, Laclav M, Dvořáková T, et al. Accuracy of EUS and CEH EUS for the diagnosis of pancreatic tumours. Scand J Gastroenterol. 2018;53(10-11):1411-1417. doi:10.1080/00365521.2018.1524024","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"542","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":542,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.95,"specificity":0.63},"tp":69.0,"fp":16.0,"fn":4.0,"tn":27.0,"sample_size":116.0,"observed_prevalence":0.6293103448275862,"sensitivity":0.9452054794520548,"specificity":0.627906976744186,"ppv_observed":0.8117647058823529,"npv_observed":0.8709677419354839,"youden_j":0.5731124561962408,"lr_positive":2.5402397260273974,"lr_negative":0.08726534753932014,"diagnostic_odds_ratio":29.109375,"baseline_entropy_bits_observed":0.9512001567617836,"conditional_entropy_bits_observed":0.659553147565435,"information_bits_observed":0.29164700919634856,"information_fraction_observed":0.3066095049744488,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8c2b2276c968"},{"id":"diagnostics-2024:543:5ca18a52dbd8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"EUS","test_or_feature":"EUS","target_condition":"Pancreatic cancer","citation":"Bunganič B, Laclav M, Dvořáková T, et al. Accuracy of EUS and CEH EUS for the diagnosis of pancreatic tumours. Scand J Gastroenterol. 2018;53(10-11):1411-1417. doi:10.1080/00365521.2018.1524023","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"543","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":543,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.84,"specificity":0.63},"tp":61.0,"fp":16.0,"fn":12.0,"tn":27.0,"sample_size":116.0,"observed_prevalence":0.6293103448275862,"sensitivity":0.8356164383561644,"specificity":0.627906976744186,"ppv_observed":0.7922077922077922,"npv_observed":0.6923076923076923,"youden_j":0.46352341510035044,"lr_positive":2.245719178082192,"lr_negative":0.2617960426179604,"diagnostic_odds_ratio":8.578125,"baseline_entropy_bits_observed":0.9512001567617836,"conditional_entropy_bits_observed":0.7887651725063061,"information_bits_observed":0.16243498425547753,"information_fraction_observed":0.17076845824801246,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c68c04e38cbb"},{"id":"diagnostics-2024:544:971d258c2738","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Femoral hyaline cartilage involvement and osteophytes on knee US","test_or_feature":"Femoral hyaline cartilage involvement and osteophytes on knee US","target_condition":"Knee osteoarthritis","citation":"Brom M, Gandino IJ, Zacariaz Hereter JB, Scolnik M, Mollerach FB, Ferreyra Garrott LG, Marin J, Ruta SO, Rosa JE, García-Mónaco RD and Soriano ER (2020) Performance of Ultrasonography Compared to Conventional Radiography for the Diagnosis of Osteoarthritis in Patients With Knee Pain. Front. Med. 7:319. doi: 10.3389/fmed.2020.00322","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"544","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":544,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.75,"specificity":0.94},"tp":137.0,"fp":8.0,"fn":46.0,"tn":131.0,"sample_size":322.0,"observed_prevalence":0.5683229813664596,"sensitivity":0.7486338797814208,"specificity":0.9424460431654677,"ppv_observed":0.9448275862068966,"npv_observed":0.7401129943502824,"youden_j":0.6910799229468885,"lr_positive":13.007513661202193,"lr_negative":0.26671672298001914,"diagnostic_odds_ratio":48.76902173913044,"baseline_entropy_bits_observed":0.9864886808644701,"conditional_entropy_bits_observed":0.5930445399727805,"information_bits_observed":0.39344414089168955,"information_fraction_observed":0.3988328994782895,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8501e3f25f66"},{"id":"diagnostics-2024:545:7c6e5ad7f03c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Femoral hyaline cartilage involvement or osteophytes on knee US","test_or_feature":"Femoral hyaline cartilage involvement or osteophytes on knee US","target_condition":"Knee osteoarthritis","citation":"Brom M, Gandino IJ, Zacariaz Hereter JB, Scolnik M, Mollerach FB, Ferreyra Garrott LG, Marin J, Ruta SO, Rosa JE, García-Mónaco RD and Soriano ER (2020) Performance of Ultrasonography Compared to Conventional Radiography for the Diagnosis of Osteoarthritis in Patients With Knee Pain. Front. Med. 7:319. doi: 10.3389/fmed.2020.00321","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"545","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":545,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.95,"specificity":0.76},"tp":174.0,"fp":33.0,"fn":9.0,"tn":106.0,"sample_size":322.0,"observed_prevalence":0.5683229813664596,"sensitivity":0.9508196721311475,"specificity":0.762589928057554,"ppv_observed":0.8405797101449275,"npv_observed":0.9217391304347826,"youden_j":0.7134096001887014,"lr_positive":4.004967709885743,"lr_negative":0.06449118465821226,"diagnostic_odds_ratio":62.101010101010104,"baseline_entropy_bits_observed":0.9864886808644701,"conditional_entropy_bits_observed":0.5483139398999252,"information_bits_observed":0.4381747409645449,"information_fraction_observed":0.44417614663410826,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"d35058fb8832"},{"id":"diagnostics-2024:546:a2d0df4172c2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Osteophytes on knee US","test_or_feature":"Osteophytes on knee US","target_condition":"Knee osteoarthritis","citation":"Brom M, Gandino IJ, Zacariaz Hereter JB, Scolnik M, Mollerach FB, Ferreyra Garrott LG, Marin J, Ruta SO, Rosa JE, García-Mónaco RD and Soriano ER (2020) Performance of Ultrasonography Compared to Conventional Radiography for the Diagnosis of Osteoarthritis in Patients With Knee Pain. Front. Med. 7:319. doi: 10.3389/fmed.2020.00320","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"546","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":546,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.82,"specificity":0.86},"tp":150.0,"fp":19.0,"fn":33.0,"tn":120.0,"sample_size":322.0,"observed_prevalence":0.5683229813664596,"sensitivity":0.819672131147541,"specificity":0.8633093525179856,"ppv_observed":0.8875739644970414,"npv_observed":0.7843137254901961,"youden_j":0.6829814836655266,"lr_positive":5.996548748921483,"lr_negative":0.20887978142076502,"diagnostic_odds_ratio":28.708133971291865,"baseline_entropy_bits_observed":0.9864886808644701,"conditional_entropy_bits_observed":0.6236138537950419,"information_bits_observed":0.3628748270694282,"information_fraction_observed":0.36784489686332467,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1f81bbb55c6f"},{"id":"diagnostics-2024:547:924425174ebb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Femoral hyaline cartilage involvement on knee US","test_or_feature":"Femoral hyaline cartilage involvement on knee US","target_condition":"Knee osteoarthritis","citation":"Brom M, Gandino IJ, Zacariaz Hereter JB, Scolnik M, Mollerach FB, Ferreyra Garrott LG, Marin J, Ruta SO, Rosa JE, García-Mónaco RD and Soriano ER (2020) Performance of Ultrasonography Compared to Conventional Radiography for the Diagnosis of Osteoarthritis in Patients With Knee Pain. Front. Med. 7:319. doi: 10.3389/fmed.2020.00319","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"547","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":547,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2020,"source_reported":{"sensitivity":0.9,"specificity":0.75},"tp":165.0,"fp":35.0,"fn":18.0,"tn":104.0,"sample_size":322.0,"observed_prevalence":0.5683229813664596,"sensitivity":0.9016393442622951,"specificity":0.7482014388489209,"ppv_observed":0.825,"npv_observed":0.8524590163934426,"youden_j":0.6498407831112161,"lr_positive":3.5807962529274007,"lr_negative":0.13146279949558637,"diagnostic_odds_ratio":27.238095238095237,"baseline_entropy_bits_observed":0.9864886808644701,"conditional_entropy_bits_observed":0.6442507499420759,"information_bits_observed":0.3422379309223942,"information_fraction_observed":0.346925350043031,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"daee64794a36"},{"id":"diagnostics-2024:548:a0d73d3df10a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Pan-enteric capsule endoscopy","test_or_feature":"Pan-enteric capsule endoscopy","target_condition":"Crohn's disease","citation":"Brodersen JB, Knudsen T, Kjeldsen J, Juel MA, Rafaelsen SR, Jensen MD. Diagnostic accuracy of pan-enteric capsule endoscopy and magnetic resonance enterocolonography in suspected Crohn's disease. United European Gastroenterol J. 2022;10(9):973-982. doi:10.1002/ueg2.12307","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"548","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":548,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.88,"specificity":0.88},"tp":35.0,"fp":9.0,"fn":5.0,"tn":65.0,"sample_size":114.0,"observed_prevalence":0.3508771929824561,"sensitivity":0.875,"specificity":0.8783783783783784,"ppv_observed":0.7954545454545454,"npv_observed":0.9285714285714286,"youden_j":0.7533783783783785,"lr_positive":7.1944444444444455,"lr_negative":0.1423076923076923,"diagnostic_odds_ratio":50.55555555555556,"baseline_entropy_bits_observed":0.9348490242345944,"conditional_entropy_bits_observed":0.5100616094635766,"information_bits_observed":0.4247874147710178,"information_fraction_observed":0.45439146189280305,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"c98b4f3019f3"},{"id":"diagnostics-2024:549:e15259a02279","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Magnetic resonance enterocolonography","test_or_feature":"Magnetic resonance enterocolonography","target_condition":"Crohn's disease","citation":"Brodersen JB, Knudsen T, Kjeldsen J, Juel MA, Rafaelsen SR, Jensen MD. Diagnostic accuracy of pan-enteric capsule endoscopy and magnetic resonance enterocolonography in suspected Crohn's disease. United European Gastroenterol J. 2022;10(9):973-982. doi:10.1002/ueg2.12307","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"549","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":549,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.68,"specificity":0.76},"tp":36.0,"fp":18.0,"fn":17.0,"tn":58.0,"sample_size":129.0,"observed_prevalence":0.4108527131782946,"sensitivity":0.6792452830188679,"specificity":0.7631578947368421,"ppv_observed":0.6666666666666666,"npv_observed":0.7733333333333333,"youden_j":0.44240317775571003,"lr_positive":2.867924528301887,"lr_negative":0.4202992843201041,"diagnostic_odds_ratio":6.823529411764706,"baseline_entropy_bits_observed":0.9769460529925407,"conditional_entropy_bits_observed":0.8333303163370429,"information_bits_observed":0.14361573665549776,"information_fraction_observed":0.14700477699416462,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9267ae75f6a0"},{"id":"diagnostics-2024:550:5e1fa7411a8a","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical diagnosis","test_or_feature":"Clinical diagnosis","target_condition":"Bacterial vaginosis","citation":"Broache M, Cammarata CL, Stonebraker E, Eckert K, Van Der Pol B, Taylor SN. Performance of a Vaginal Panel Assay Compared With the Clinical Diagnosis of Vaginitis. Obstet Gynecol. 2021;138(6):853-859. doi:10.1097/AOG.0000000000004592","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"550","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":550,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.58,"specificity":0.8},"tp":142.0,"fp":44.0,"fn":103.0,"tn":178.0,"sample_size":467.0,"observed_prevalence":0.5246252676659529,"sensitivity":0.5795918367346938,"specificity":0.8018018018018018,"ppv_observed":0.7634408602150538,"npv_observed":0.6334519572953736,"youden_j":0.38139363853649577,"lr_positive":2.92430426716141,"lr_negative":0.5243292822747077,"diagnostic_odds_ratio":5.577228596646072,"baseline_entropy_bits_observed":0.9982495804262501,"conditional_entropy_bits_observed":0.8847711941040213,"information_bits_observed":0.11347838632222884,"information_fraction_observed":0.11367736941474481,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"12365c33d4bb"},{"id":"diagnostics-2024:551:a1656bfb0dc5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Multiplex PCR","test_or_feature":"Multiplex PCR","target_condition":"Bacterial vaginosis","citation":"Bornstein J, Lakovsky Y, Lavi I, Bar-Am A, Abramovici H. The classic approach to diagnosis of vulvovaginitis: a critical analysis. Infect Dis Obstet Gynecol. 2001;9(2):105-111. doi:10.1155/S1064744901000187","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"551","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":551,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2001,"source_reported":{"sensitivity":0.7,"specificity":0.97},"tp":120.0,"fp":3.0,"fn":51.0,"tn":94.0,"sample_size":268.0,"observed_prevalence":0.6380597014925373,"sensitivity":0.7017543859649122,"specificity":0.9690721649484536,"ppv_observed":0.975609756097561,"npv_observed":0.6482758620689655,"youden_j":0.670826550913366,"lr_positive":22.690058479532162,"lr_negative":0.3077640910787608,"diagnostic_odds_ratio":73.72549019607843,"baseline_entropy_bits_observed":0.9442820048695637,"conditional_entropy_bits_observed":0.5821242490129184,"information_bits_observed":0.36215775585664534,"information_fraction_observed":0.3835271179467951,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"036362bc794e"},{"id":"diagnostics-2024:552:1061d154033f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"FDG PET scan","test_or_feature":"FDG PET scan","target_condition":"Malignant adrenal mass","citation":"Boland GWL et al. Characterization of Adrenal Masses by Using FDG PET: A Systematic Review and Meta-Analysis of Diagnostic Test Performance. Radiology. 2011;259:1, 117-126. doi: https://doi.org/10.1148/radiol.11100569","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"552","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":552,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.97,"specificity":0.91},"tp":550.0,"fp":74.0,"fn":17.0,"tn":750.0,"sample_size":1391.0,"observed_prevalence":0.4076204169662114,"sensitivity":0.9700176366843033,"specificity":0.9101941747572816,"ppv_observed":0.8814102564102564,"npv_observed":0.9778357235984355,"youden_j":0.8802118114415849,"lr_positive":10.80127746794414,"lr_negative":0.03294062316284544,"diagnostic_odds_ratio":327.90143084260734,"baseline_entropy_bits_observed":0.9752340756125369,"conditional_entropy_bits_observed":0.3202449074212439,"information_bits_observed":0.654989168191293,"information_fraction_observed":0.6716225207572853,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a983b2e5fc03"},{"id":"diagnostics-2024:553:232cc9bb29da","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Clinical breast examination","test_or_feature":"Clinical breast examination","target_condition":"Breast cancer","citation":"Bobo JK, Lee NC, Thames SF. Findings from 752,081 clinical breast examinations reported to a national screening program from 1995 through 1998. J Natl Cancer Inst. 2000;92(12):971-976. doi:10.1093/jnci/92.12.971","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"553","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":553,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1995,"source_reported":{"sensitivity":0.59,"specificity":0.93},"tp":2211.0,"fp":49389.0,"fn":1549.0,"tn":698932.0,"sample_size":752081.0,"observed_prevalence":0.0049994614941741644,"sensitivity":0.5880319148936171,"specificity":0.934000248556435,"ppv_observed":0.042848837209302326,"npv_observed":0.9977886623620056,"youden_j":0.522032163450052,"lr_positive":8.909608021727644,"lr_negative":0.4410792028622149,"diagnostic_odds_ratio":20.199564984955405,"baseline_entropy_bits_observed":0.04541057992489801,"conditional_entropy_bits_observed":0.03864524465361172,"information_bits_observed":0.006765335271286289,"information_fraction_observed":0.14898147705832196,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fc0d7344ebab"},{"id":"diagnostics-2024:554:0a2f82e8c611","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ISG 1990 criteria","test_or_feature":"ISG 1990 criteria","target_condition":"Behcet disease","citation":"Blake T, Pickup L, Carruthers D, et al. Birmingham Behçet's service: classification of disease and application of the 2014 International Criteria for Behçet's Disease (ICBD) to a UK cohort. BMC Musculoskelet Disord. 2017;18(1):101. Published 2017 Mar 11. doi:10.1186/s12891-017-1463-y","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"554","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":554,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.78,"specificity":0.69},"tp":148.0,"fp":28.0,"fn":42.0,"tn":63.0,"sample_size":281.0,"observed_prevalence":0.6761565836298933,"sensitivity":0.7789473684210526,"specificity":0.6923076923076923,"ppv_observed":0.8409090909090909,"npv_observed":0.6,"youden_j":0.4712550607287449,"lr_positive":2.5315789473684207,"lr_negative":0.31929824561403514,"diagnostic_odds_ratio":7.928571428571429,"baseline_entropy_bits_observed":0.9085121642032697,"conditional_entropy_bits_observed":0.758735734402872,"information_bits_observed":0.14977642980039774,"information_fraction_observed":0.16485902523027407,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fabe5309ed74"},{"id":"diagnostics-2024:555:ced1861dda29","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ICBD 2014 criteria","test_or_feature":"ICBD 2014 criteria","target_condition":"Behcet disease","citation":"Blake T, Pickup L, Carruthers D, et al. Birmingham Behçet's service: classification of disease and application of the 2014 International Criteria for Behçet's Disease (ICBD) to a UK cohort. BMC Musculoskelet Disord. 2017;18(1):101. Published 2017 Mar 11. doi:10.1186/s12891-017-1463-y","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"555","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":555,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.98,"specificity":0.19},"tp":186.0,"fp":74.0,"fn":4.0,"tn":17.0,"sample_size":281.0,"observed_prevalence":0.6761565836298933,"sensitivity":0.9789473684210527,"specificity":0.18681318681318682,"ppv_observed":0.7153846153846154,"npv_observed":0.8095238095238095,"youden_j":0.1657605552342396,"lr_positive":1.2038406827880512,"lr_negative":0.11269349845201214,"diagnostic_odds_ratio":10.682432432432432,"baseline_entropy_bits_observed":0.9085121642032697,"conditional_entropy_bits_observed":0.8497663382272607,"information_bits_observed":0.05874582597600908,"information_fraction_observed":0.06466157338413506,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e7b7cae6a692"},{"id":"diagnostics-2024:556:43a0fc98aa77","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serology","test_or_feature":"Serology","target_condition":"H.pylori infection","citation":"Best LM, Takwoingi Y, Siddique S, et al. Non-invasive diagnostic tests for Helicobacter pylori infection. Cochrane Database Syst Rev. 2018;3(3):CD012080. Published 2018 Mar 15. doi:10.1002/14651858.CD012080.pub3","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"556","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":556,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.91,"specificity":0.86},"tp":3056.0,"fp":350.0,"fn":292.0,"tn":2067.0,"sample_size":5765.0,"observed_prevalence":0.580745880312229,"sensitivity":0.9127837514934289,"specificity":0.85519238725693,"ppv_observed":0.897240164415737,"npv_observed":0.8762187367528613,"youden_j":0.767976138750359,"lr_positive":6.303423792456049,"lr_negative":0.10198436025175726,"diagnostic_odds_ratio":61.80774951076321,"baseline_entropy_bits_observed":0.981104918048594,"conditional_entropy_bits_observed":0.5032375088265534,"information_bits_observed":0.47786740922204063,"information_fraction_observed":0.4870706490520027,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4425f55173c2"},{"id":"diagnostics-2024:557:7b31fe0a3123","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Stool antigen","test_or_feature":"Stool antigen","target_condition":"H.pylori infection","citation":"Best LM, Takwoingi Y, Siddique S, et al. Non-invasive diagnostic tests for Helicobacter pylori infection. Cochrane Database Syst Rev. 2018;3(3):CD012080. Published 2018 Mar 15. doi:10.1002/14651858.CD012080.pub2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"557","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":557,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.79,"specificity":0.88},"tp":1032.0,"fp":196.0,"fn":278.0,"tn":1481.0,"sample_size":2987.0,"observed_prevalence":0.43856712420488786,"sensitivity":0.7877862595419848,"specificity":0.8831246273106739,"ppv_observed":0.8403908794788274,"npv_observed":0.8419556566230812,"youden_j":0.6709108868526585,"lr_positive":6.740395700264842,"lr_negative":0.24029874594739467,"diagnostic_odds_ratio":28.050066069593306,"baseline_entropy_bits_observed":0.9890829782920716,"conditional_entropy_bits_observed":0.6311575227601145,"information_bits_observed":0.3579254555319571,"information_fraction_observed":0.36187606438239944,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"24c0ddc46836"},{"id":"diagnostics-2024:558:50ae7ec45bd9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum gastrin post secretin","test_or_feature":"Serum gastrin post secretin","target_condition":"Zollinger-Ellison syndrome","citation":"Berna MJ, Hoffmann KM, Long SH, Serrano J, Gibril F, Jensen RT. Serum gastrin in Zollinger-Ellison syndrome: II. Prospective study of gastrin provocative testing in 293 patients from the National Institutes of Health and comparison with 537 cases from the literature. evaluation of diagnostic criteria, proposal of new criteria, and correlations with clinical and tumoral features. Medicine (Baltimore). 2006;85(6):331-364. doi:10.1097/MD.0b013e31802b518c","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"558","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":558,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.94,"specificity":1.0},"tp":505.0,"fp":0.0,"fn":32.0,"tn":462.0,"sample_size":999.0,"observed_prevalence":0.5375375375375375,"sensitivity":0.9404096834264432,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9352226720647774,"youden_j":0.9404096834264433,"lr_positive":null,"lr_negative":0.059590316573556845,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.995930464977218,"conditional_entropy_bits_observed":0.17115651178039257,"information_bits_observed":0.8247739531968254,"information_fraction_observed":0.8281441146754078,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"b638ba2457b6"},{"id":"diagnostics-2024:559:b78537d6420e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum gastrin post calcium","test_or_feature":"Serum gastrin post calcium","target_condition":"Zollinger-Ellison syndrome","citation":"Berna MJ, Hoffmann KM, Long SH, Serrano J, Gibril F, Jensen RT. Serum gastrin in Zollinger-Ellison syndrome: II. Prospective study of gastrin provocative testing in 293 patients from the National Institutes of Health and comparison with 537 cases from the literature. evaluation of diagnostic criteria, proposal of new criteria, and correlations with clinical and tumoral features. Medicine (Baltimore). 2006;85(6):331-364. doi:10.1097/MD.0b013e31802b518c","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"559","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":559,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.62,"specificity":1.0},"tp":333.0,"fp":0.0,"fn":204.0,"tn":462.0,"sample_size":999.0,"observed_prevalence":0.5375375375375375,"sensitivity":0.6201117318435754,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.6936936936936937,"youden_j":0.6201117318435754,"lr_positive":null,"lr_negative":0.3798882681564246,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.995930464977218,"conditional_entropy_bits_observed":0.5925757413143713,"information_bits_observed":0.40335472366284675,"information_fraction_observed":0.4050028971370742,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"67a460c2d045"},{"id":"diagnostics-2024:560:d3348a584341","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Doppler ultrasound","test_or_feature":"Doppler ultrasound","target_condition":"Ovarian torsion","citation":"Ben-Ami M, Perlitz Y, Haddad S. The effectiveness of spectral and color Doppler in predicting ovarian torsion. A prospective study. Eur J Obstet Gynecol Reprod Biol. 2002;104(1):64-66. doi:10.1016/s0301-2115(02)00056-8","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"560","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":560,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2002,"source_reported":{"sensitivity":0.93,"specificity":0.98},"tp":14.0,"fp":1.0,"fn":1.0,"tn":49.0,"sample_size":65.0,"observed_prevalence":0.23076923076923078,"sensitivity":0.9333333333333333,"specificity":0.98,"ppv_observed":0.9333333333333333,"npv_observed":0.98,"youden_j":0.9133333333333333,"lr_positive":46.66666666666663,"lr_negative":0.06802721088435373,"diagnostic_odds_ratio":686.0,"baseline_entropy_bits_observed":0.7793498372920853,"conditional_entropy_bits_observed":0.19034487926788238,"information_bits_observed":0.5890049580242029,"information_fraction_observed":0.755764522991047,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"caf3749aefc7","condition_context_id":"condition:ovarian_torsion"},{"id":"diagnostics-2024:561:5ea557aeb3b5","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"D-dimer","test_or_feature":"D-dimer","target_condition":"VTE in pregnancy","citation":"Bellesini M, Robert-Ebadi H, Combescure C, Dedionigi C, Le Gal G, Righini M. D-dimer to rule out venous thromboembolism during pregnancy: A systematic review and meta-analysis. J Thromb Haemost. 2021;19(10):2454-2467. doi:10.1111/jth.15432","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"561","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":561,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.99,"specificity":1.0},"tp":68.0,"fp":1.0,"fn":1.0,"tn":354.0,"sample_size":424.0,"observed_prevalence":0.16273584905660377,"sensitivity":0.9855072463768116,"specificity":0.9971830985915493,"ppv_observed":0.9855072463768116,"npv_observed":0.9971830985915493,"youden_j":0.9826903449683608,"lr_positive":349.8550724637686,"lr_negative":0.014533693605174767,"diagnostic_odds_ratio":24072.0,"baseline_entropy_bits_observed":0.6408145851602052,"conditional_entropy_bits_observed":0.041162855406757626,"information_bits_observed":0.5996517297534476,"information_fraction_observed":0.9357647963077077,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"aa7adb87b3c6"},{"id":"diagnostics-2024:562:b802a0f66149","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal MRI","test_or_feature":"Abdominal MRI","target_condition":"Hepatocellular carcinoma","citation":"Becker-Weidman DJ, Kalb B, Sharma P, et al. Hepatocellular carcinoma lesion characterization: single-institution clinical performance review of multiphase gadolinium-enhanced MR imaging--comparison to prior same-center results after MR systems improvements. Radiology. 2011;261(3):824-833. doi:10.1148/radiol.11110157","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"562","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":562,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.97,"specificity":1.0},"tp":34.0,"fp":0.0,"fn":1.0,"tn":66.0,"sample_size":101.0,"observed_prevalence":0.3465346534653465,"sensitivity":0.9714285714285714,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9850746268656716,"youden_j":0.9714285714285715,"lr_positive":null,"lr_negative":0.02857142857142858,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9309350721504901,"conditional_entropy_bits_observed":0.07423726616844387,"information_bits_observed":0.8566978059820463,"information_fraction_observed":0.920255162374586,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a9bc397e7122"},{"id":"diagnostics-2024:563:4cd6e54decae","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRCP","test_or_feature":"MRCP","target_condition":"Choledocholithiasis","citation":"Becker CD, Grossholz M, Becker M, Mentha G, de Peyer R, Terrier F. Choledocholithiasis and bile duct stenosis: diagnostic accuracy of MR cholangiopancreatography. Radiology. 1997;205(2):523-530. doi:10.1148/radiology.205.2.9356639","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"563","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":563,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1997,"source_reported":{"sensitivity":0.87,"specificity":0.91},"tp":20.0,"fp":8.0,"fn":3.0,"tn":77.0,"sample_size":108.0,"observed_prevalence":0.21296296296296297,"sensitivity":0.8695652173913043,"specificity":0.9058823529411765,"ppv_observed":0.7142857142857143,"npv_observed":0.9625,"youden_j":0.7754475703324808,"lr_positive":9.23913043478261,"lr_negative":0.14398644833427446,"diagnostic_odds_ratio":64.16666666666667,"baseline_entropy_bits_observed":0.7471082932651728,"conditional_entropy_bits_observed":0.3946682627331831,"information_bits_observed":0.3524400305319897,"information_fraction_observed":0.47173888137646114,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"11f88003ebc3"},{"id":"diagnostics-2024:564:634fa5077b31","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Mammography","test_or_feature":"Mammography","target_condition":"Breast cancer","citation":"Banks E, Reeves G, Beral V, et al. Influence of personal characteristics of individual women on sensitivity and specificity of mammography in the Million Women Study: cohort study. BMJ. 2004;329(7464):477. doi:10.1136/bmj.329.7464.477","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"564","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":564,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.87,"specificity":0.97},"tp":629.0,"fp":3885.0,"fn":97.0,"tn":117744.0,"sample_size":122355.0,"observed_prevalence":0.00593355400269707,"sensitivity":0.8663911845730028,"specificity":0.9680586044446637,"ppv_observed":0.13934426229508196,"npv_observed":0.9991768569513158,"youden_j":0.8344497890176665,"lr_positive":27.124399842581703,"lr_negative":0.1380172799596603,"diagnostic_odds_ratio":196.52901325478646,"baseline_entropy_bits_observed":0.052424695206472846,"conditional_entropy_bits_observed":0.030757152540989173,"information_bits_observed":0.021667542665483673,"information_fraction_observed":0.4133079377981466,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"7d9df0d94df7"},{"id":"diagnostics-2024:565:b3c9e6d9ff7d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abnormal aPTT waveform","test_or_feature":"Abnormal aPTT waveform","target_condition":"Disseminated intravascular coagulation","citation":"Bakhtiari K, Meijers JC, de Jonge E, Levi M. Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation. Crit Care Med. 2004;32(12):2416-2421. doi:10.1097/01.ccm.0000147769.07699.e4","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"565","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":565,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.88,"specificity":0.97},"tp":65.0,"fp":4.0,"fn":9.0,"tn":139.0,"sample_size":217.0,"observed_prevalence":0.34101382488479265,"sensitivity":0.8783783783783784,"specificity":0.972027972027972,"ppv_observed":0.9420289855072463,"npv_observed":0.9391891891891891,"youden_j":0.8504063504063504,"lr_positive":31.402027027026968,"lr_negative":0.12512152440209992,"diagnostic_odds_ratio":250.97222222222223,"baseline_entropy_bits_observed":0.9257855632470048,"conditional_entropy_bits_observed":0.32705642240728283,"information_bits_observed":0.598729140839722,"information_fraction_observed":0.6467255103220676,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fc2be627366a"},{"id":"diagnostics-2024:566:4161dd293e6b","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ISTH DIC score","test_or_feature":"ISTH DIC score","target_condition":"Disseminated intravascular coagulation","citation":"Bakhtiari K, Meijers JC, de Jonge E, Levi M. Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation. Crit Care Med. 2004;32(12):2416-2421. doi:10.1097/01.ccm.0000147769.07699.e3","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"566","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":566,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.91,"specificity":0.97},"tp":67.0,"fp":4.0,"fn":7.0,"tn":139.0,"sample_size":217.0,"observed_prevalence":0.34101382488479265,"sensitivity":0.9054054054054054,"specificity":0.972027972027972,"ppv_observed":0.9436619718309859,"npv_observed":0.952054794520548,"youden_j":0.8774333774333773,"lr_positive":32.368243243243185,"lr_negative":0.09731674120163333,"diagnostic_odds_ratio":332.60714285714283,"baseline_entropy_bits_observed":0.9257855632470048,"conditional_entropy_bits_observed":0.2890975196206149,"information_bits_observed":0.6366880436263899,"information_fraction_observed":0.6877273408685872,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6104a864ddbf"},{"id":"diagnostics-2024:567:78512ae8b7bb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"H&P and ECG","test_or_feature":"H&P and ECG","target_condition":"Structural heart disease in athletes","citation":"Baggish, A.L. Cardiovascular screening in college athletes with and without electrocardiography. Annals of Internal Medicine, 2010;152(5):269. doi: https://doi.org/10.7326/0003-4819-152-5-201003020-00004.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"567","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":567,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.91,"specificity":0.83},"tp":10.0,"fp":86.0,"fn":1.0,"tn":413.0,"sample_size":510.0,"observed_prevalence":0.021568627450980392,"sensitivity":0.9090909090909091,"specificity":0.8276553106212425,"ppv_observed":0.10416666666666667,"npv_observed":0.9975845410628019,"youden_j":0.7367462197121517,"lr_positive":5.274841437632137,"lr_negative":0.10983931322914377,"diagnostic_odds_ratio":48.02325581395349,"baseline_entropy_bits_observed":0.15015960456806723,"conditional_entropy_bits_observed":0.11061331063620913,"information_bits_observed":0.0395462939318581,"information_fraction_observed":0.2633617346397033,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4aa73f7ea8eb"},{"id":"diagnostics-2024:568:50f9fa6a0577","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"H&P","test_or_feature":"H&P","target_condition":"Structural heart disease in athletes","citation":"Baggish, A.L. Cardiovascular screening in college athletes with and without electrocardiography. Annals of Internal Medicine, 2010;152(5):269. doi: https://doi.org/10.7326/0003-4819-152-5-201003020-00004.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"568","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":568,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2010,"source_reported":{"sensitivity":0.45,"specificity":0.94},"tp":5.0,"fp":28.0,"fn":6.0,"tn":471.0,"sample_size":510.0,"observed_prevalence":0.021568627450980392,"sensitivity":0.45454545454545453,"specificity":0.9438877755511023,"ppv_observed":0.15151515151515152,"npv_observed":0.9874213836477987,"youden_j":0.39843323009655673,"lr_positive":8.100649350649359,"lr_negative":0.5778807180081065,"diagnostic_odds_ratio":14.017857142857142,"baseline_entropy_bits_observed":0.15015960456806723,"conditional_entropy_bits_observed":0.13083965605776554,"information_bits_observed":0.019319948510301693,"information_fraction_observed":0.12866275564507082,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"06a971046442"},{"id":"diagnostics-2024:569:7abd2dede144","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ottawa knee rule","test_or_feature":"Ottawa knee rule","target_condition":"Knee fracture","citation":"Bachmann LM, Haberzeth S, Steurer J, ter Riet G. The accuracy of the Ottawa knee rule to rule out knee fractures: a systematic review. Ann Intern Med. 2004;140(2):121-124. doi:10.7326/0003-4819-140-5-200403020-00013","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"569","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":569,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2004,"source_reported":{"sensitivity":0.99,"specificity":0.49},"tp":267.0,"fp":2043.0,"fn":4.0,"tn":1935.0,"sample_size":4249.0,"observed_prevalence":0.06377971287361732,"sensitivity":0.985239852398524,"specificity":0.48642533936651583,"ppv_observed":0.11558441558441558,"npv_observed":0.9979370809695719,"youden_j":0.47166519176503985,"lr_positive":1.918396540793602,"lr_negative":0.030344117394662366,"diagnostic_odds_ratio":63.22136563876652,"baseline_entropy_bits_observed":0.3422697306424147,"conditional_entropy_bits_observed":0.29057242779734765,"information_bits_observed":0.05169730284506707,"information_fraction_observed":0.1510425790444136,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"41d163dff532"},{"id":"diagnostics-2024:570:4e839eb4b98d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PCR","test_or_feature":"PCR","target_condition":"Aspergillosis","citation":"Avni T, Levy I, Sprecher H, Yahav D, Leibovici L, Paul M. Diagnostic accuracy of PCR alone compared to galactomannan in bronchoalveolar lavage fluid for diagnosis of invasive pulmonary aspergillosis: a systematic review. J Clin Microbiol. 2012;50(11):3652-3658. doi:10.1128/JCM.00942-12","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"570","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":570,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.77,"specificity":0.94},"tp":242.0,"fp":61.0,"fn":73.0,"tn":1040.0,"sample_size":1416.0,"observed_prevalence":0.22245762711864406,"sensitivity":0.7682539682539683,"specificity":0.9445958219800181,"ppv_observed":0.7986798679867987,"npv_observed":0.9344115004492363,"youden_j":0.7128497902339865,"lr_positive":13.866354410616696,"lr_negative":0.2453388278388278,"diagnostic_odds_ratio":56.519200538962494,"baseline_entropy_bits_observed":0.7646297354881082,"conditional_entropy_bits_observed":0.4295528779055672,"information_bits_observed":0.335076857582541,"information_fraction_observed":0.43822106574058584,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0482ef78ac93"},{"id":"diagnostics-2024:571:93ec8be922c4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Carroll's ECG criteria and Doppler US","test_or_feature":"Carroll's ECG criteria and Doppler US","target_condition":"Cardiac amyloidosis","citation":"Austin BA, Tang WH, Rodriguez ER, et al. Delayed hyper-enhancement magnetic resonance imaging provides incremental diagnostic and prognostic utility in suspected cardiac amyloidosis. JACC Cardiovasc Imaging. 2009;2(12):1369-1377. doi:10.1016/j.jcmg.2009.08.011","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"571","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":571,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.88,"specificity":0.29},"tp":15.0,"fp":15.0,"fn":2.0,"tn":6.0,"sample_size":38.0,"observed_prevalence":0.4473684210526316,"sensitivity":0.8823529411764706,"specificity":0.2857142857142857,"ppv_observed":0.5,"npv_observed":0.75,"youden_j":0.16806722689075615,"lr_positive":1.2352941176470587,"lr_negative":0.41176470588235303,"diagnostic_odds_ratio":3.0,"baseline_entropy_bits_observed":0.9919924034538556,"conditional_entropy_bits_observed":0.9602690788335017,"information_bits_observed":0.03172332462035399,"information_fraction_observed":0.03197940277556738,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ed5534a9e8e1"},{"id":"diagnostics-2024:572:d238be126fd9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Doppler US","test_or_feature":"Doppler US","target_condition":"Cardiac amyloidosis","citation":"Austin BA, Tang WH, Rodriguez ER, et al. Delayed hyper-enhancement magnetic resonance imaging provides incremental diagnostic and prognostic utility in suspected cardiac amyloidosis. JACC Cardiovasc Imaging. 2009;2(12):1369-1377. doi:10.1016/j.jcmg.2009.08.010","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"572","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":572,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.35,"specificity":0.62},"tp":6.0,"fp":8.0,"fn":11.0,"tn":13.0,"sample_size":38.0,"observed_prevalence":0.4473684210526316,"sensitivity":0.35294117647058826,"specificity":0.6190476190476191,"ppv_observed":0.42857142857142855,"npv_observed":0.5416666666666666,"youden_j":-0.028011204481792618,"lr_positive":0.9264705882352943,"lr_negative":1.0452488687782804,"diagnostic_odds_ratio":0.8863636363636364,"baseline_entropy_bits_observed":0.9919924034538556,"conditional_entropy_bits_observed":0.9913902573932316,"information_bits_observed":0.0006021460606240314,"information_fraction_observed":0.0006070067255832986,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"08369c2526be"},{"id":"diagnostics-2024:573:368e06cbcfb2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Carroll's ECG criteria","test_or_feature":"Carroll's ECG criteria","target_condition":"Cardiac amyloidosis","citation":"Austin BA, Tang WH, Rodriguez ER, et al. Delayed hyper-enhancement magnetic resonance imaging provides incremental diagnostic and prognostic utility in suspected cardiac amyloidosis. JACC Cardiovasc Imaging. 2009;2(12):1369-1377. doi:10.1016/j.jcmg.2009.08.009","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"573","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":573,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.76,"specificity":0.48},"tp":13.0,"fp":11.0,"fn":4.0,"tn":10.0,"sample_size":38.0,"observed_prevalence":0.4473684210526316,"sensitivity":0.7647058823529411,"specificity":0.47619047619047616,"ppv_observed":0.5416666666666666,"npv_observed":0.7142857142857143,"youden_j":0.2408963585434174,"lr_positive":1.459893048128342,"lr_negative":0.49411764705882366,"diagnostic_odds_ratio":2.9545454545454546,"baseline_entropy_bits_observed":0.9919924034538556,"conditional_entropy_bits_observed":0.9464032588525292,"information_bits_observed":0.04558914460132646,"information_fraction_observed":0.04595715092433883,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"689a6d6b8c21"},{"id":"diagnostics-2024:574:4bacd682d7e0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"DHE-CMR","test_or_feature":"DHE-CMR","target_condition":"Cardiac amyloidosis","citation":"Austin BA, Tang WH, Rodriguez ER, et al. Delayed hyper-enhancement magnetic resonance imaging provides incremental diagnostic and prognostic utility in suspected cardiac amyloidosis. JACC Cardiovasc Imaging. 2009;2(12):1369-1377. doi:10.1016/j.jcmg.2009.08.008","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"574","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":574,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.88,"specificity":0.9},"tp":15.0,"fp":2.0,"fn":2.0,"tn":19.0,"sample_size":38.0,"observed_prevalence":0.4473684210526316,"sensitivity":0.8823529411764706,"specificity":0.9047619047619048,"ppv_observed":0.8823529411764706,"npv_observed":0.9047619047619048,"youden_j":0.7871148459383752,"lr_positive":9.264705882352942,"lr_negative":0.130030959752322,"diagnostic_odds_ratio":71.25,"baseline_entropy_bits_observed":0.9919924034538556,"conditional_entropy_bits_observed":0.48451453921194304,"information_bits_observed":0.5074778642419127,"information_fraction_observed":0.5115743452016455,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"2b292a4b9771"},{"id":"diagnostics-2024:575:c693574ea90f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum TIBC","test_or_feature":"Serum TIBC","target_condition":"Iron deficiency anemia","citation":"Asif N, Ijaz A, Rafi T, Haroon ZH, Bashir S, Ayyub M. Diagnostic Accuracy of Serum Iron and Total Iron Binding Capacity (TIBC) in Iron Deficiency State. J Coll Physicians Surg Pak. 2016;26(12):958-961.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"575","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":575,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.64,"specificity":0.43},"tp":454.0,"fp":635.0,"fn":250.0,"tn":476.0,"sample_size":1815.0,"observed_prevalence":0.3878787878787879,"sensitivity":0.6448863636363636,"specificity":0.42844284428442847,"ppv_observed":0.41689623507805323,"npv_observed":0.6556473829201102,"youden_j":0.07332920792079212,"lr_positive":1.1282972440944883,"lr_negative":0.8288471638655461,"diagnostic_odds_ratio":1.3612850393700788,"baseline_entropy_bits_observed":0.9634170035916869,"conditional_entropy_bits_observed":0.9595572571149575,"information_bits_observed":0.0038597464767293754,"information_fraction_observed":0.004006309274530101,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"77384e38e753"},{"id":"diagnostics-2024:576:7bd2d27283ba","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Serum iron","test_or_feature":"Serum iron","target_condition":"Iron deficiency anemia","citation":"Asif N, Ijaz A, Rafi T, Haroon ZH, Bashir S, Ayyub M. Diagnostic Accuracy of Serum Iron and Total Iron Binding Capacity (TIBC) in Iron Deficiency State. J Coll Physicians Surg Pak. 2016;26(12):958-961.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"576","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":576,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2016,"source_reported":{"sensitivity":0.64,"specificity":0.39},"tp":480.0,"fp":650.0,"fn":275.0,"tn":410.0,"sample_size":1815.0,"observed_prevalence":0.41597796143250687,"sensitivity":0.6357615894039735,"specificity":0.3867924528301887,"ppv_observed":0.4247787610619469,"npv_observed":0.5985401459854015,"youden_j":0.022554042234162353,"lr_positive":1.0367804381049415,"lr_negative":0.9416895493458245,"diagnostic_odds_ratio":1.100979020979021,"baseline_entropy_bits_observed":0.9795330327464804,"conditional_entropy_bits_observed":0.9791531032670946,"information_bits_observed":0.0003799294793858099,"information_fraction_observed":0.0003878679602264542,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0b0fa0484533"},{"id":"diagnostics-2024:577:27567c00033d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Point-of-care β-hydroxybutyrate","test_or_feature":"Point-of-care β-hydroxybutyrate","target_condition":"Diabetic ketoacidosis","citation":"Arora S, Henderson SO, Long T, Menchine M. Diagnostic accuracy of point-of-care testing for diabetic ketoacidosis at emergency-department triage: {beta}-hydroxybutyrate versus the urine dipstick. Diabetes Care. 2011;34(4):852-854. doi:10.2337/dc10-1845","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"577","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":577,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.98,"specificity":0.79},"tp":53.0,"fp":99.0,"fn":1.0,"tn":363.0,"sample_size":516.0,"observed_prevalence":0.10465116279069768,"sensitivity":0.9814814814814815,"specificity":0.7857142857142857,"ppv_observed":0.34868421052631576,"npv_observed":0.9972527472527473,"youden_j":0.7671957671957672,"lr_positive":4.580246913580247,"lr_negative":0.023569023569023535,"diagnostic_odds_ratio":194.33333333333334,"baseline_entropy_bits_observed":0.4835683750917698,"conditional_entropy_bits_observed":0.29408410601465507,"information_bits_observed":0.18948426907711474,"information_fraction_observed":0.39184586676321653,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"099d5b5ed35e"},{"id":"diagnostics-2024:578:9b03172a941d","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Urine dipstick","test_or_feature":"Urine dipstick","target_condition":"Diabetic ketoacidosis","citation":"Arora S, Henderson SO, Long T, Menchine M. Diagnostic accuracy of point-of-care testing for diabetic ketoacidosis at emergency-department triage: {beta}-hydroxybutyrate versus the urine dipstick. Diabetes Care. 2011;34(4):852-854. doi:10.2337/dc10-1844","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"578","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":578,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2011,"source_reported":{"sensitivity":0.98,"specificity":0.35},"tp":53.0,"fp":300.0,"fn":1.0,"tn":162.0,"sample_size":516.0,"observed_prevalence":0.10465116279069768,"sensitivity":0.9814814814814815,"specificity":0.35064935064935066,"ppv_observed":0.1501416430594901,"npv_observed":0.9938650306748467,"youden_j":0.33213083213083205,"lr_positive":1.5114814814814816,"lr_negative":0.052812071330589766,"diagnostic_odds_ratio":28.62,"baseline_entropy_bits_observed":0.4835683750917698,"conditional_entropy_bits_observed":0.434468413171452,"information_bits_observed":0.04909996192031779,"information_fraction_observed":0.10153675146973741,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"afaec813ad61"},{"id":"diagnostics-2024:579:6aca38379d70","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ACR criteria, 5 criteria","test_or_feature":"ACR criteria, 5 criteria","target_condition":"Takayasu arteritis","citation":"Arend WP, Michel BA, Bloch DA, et al. The American College of Rheumatology 1990 criteria for the classification of Takayasu arteritis. Arthritis Rheum. 1990;33(8):1129-1134. doi:10.1002/art.1780330812","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"579","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":579,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1990,"source_reported":{"sensitivity":0.92,"specificity":0.97},"tp":58.0,"fp":20.0,"fn":5.0,"tn":661.0,"sample_size":744.0,"observed_prevalence":0.0846774193548387,"sensitivity":0.9206349206349206,"specificity":0.9706314243759178,"ppv_observed":0.7435897435897436,"npv_observed":0.9924924924924925,"youden_j":0.8912663450108385,"lr_positive":31.347619047619038,"lr_negative":0.08176644333981707,"diagnostic_odds_ratio":383.38,"baseline_entropy_bits_observed":0.41844964710707017,"conditional_entropy_bits_observed":0.143190180637834,"information_bits_observed":0.27525946646923616,"information_fraction_observed":0.6578078590153633,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"65a683562414"},{"id":"diagnostics-2024:580:bcf3d4b33f51","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"ACR criteria, 6 criteria","test_or_feature":"ACR criteria, 6 criteria","target_condition":"Takayasu arteritis","citation":"Arend WP, Michel BA, Bloch DA, et al. The American College of Rheumatology 1990 criteria for the classification of Takayasu arteritis. Arthritis Rheum. 1990;33(8):1129-1134. doi:10.1002/art.1780330811","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"580","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":580,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1990,"source_reported":{"sensitivity":0.9,"specificity":0.98},"tp":57.0,"fp":15.0,"fn":6.0,"tn":666.0,"sample_size":744.0,"observed_prevalence":0.0846774193548387,"sensitivity":0.9047619047619048,"specificity":0.9779735682819384,"ppv_observed":0.7916666666666666,"npv_observed":0.9910714285714286,"youden_j":0.882735473043843,"lr_positive":41.07619047619057,"lr_negative":0.09738309738309738,"diagnostic_odds_ratio":421.8,"baseline_entropy_bits_observed":0.41844964710707017,"conditional_entropy_bits_observed":0.13792748789767179,"information_bits_observed":0.2805221592093984,"information_fraction_observed":0.6703845042020556,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fed6f2055d09"},{"id":"diagnostics-2024:581:e5f4db31d1e4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Screening funduscopic and OCT imaging","test_or_feature":"Screening funduscopic and OCT imaging","target_condition":"Glaucoma","citation":"Anton A, Nolivos K, Pazos M, et al. Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine. J Clin Med. 2021;11(1):216. Published 2021 Dec 31. doi:10.3390/jcm11010216","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"581","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":581,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.86,"specificity":0.82},"tp":50.0,"fp":51.0,"fn":8.0,"tn":236.0,"sample_size":345.0,"observed_prevalence":0.1681159420289855,"sensitivity":0.8620689655172413,"specificity":0.8222996515679443,"ppv_observed":0.49504950495049505,"npv_observed":0.9672131147540983,"youden_j":0.6843686170851857,"lr_positive":4.851250845165652,"lr_negative":0.1677381648158972,"diagnostic_odds_ratio":28.92156862745098,"baseline_entropy_bits_observed":0.65337665116315,"conditional_entropy_bits_observed":0.43996814070898116,"information_bits_observed":0.21340851045416886,"information_fraction_observed":0.3266240231790593,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"8f912a52538b"},{"id":"diagnostics-2024:582:b11dd0adef16","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Enhanced CT","test_or_feature":"Enhanced CT","target_condition":"Choledocholithiasis","citation":"Anderson SW et al. Accuracy of MDCT in Diagnosis of Choledocholithiasis. American Journal of Roentgenology. 2006;187: 174-180. doi: 10.2214/AJR.05.0460","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"582","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":582,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.86,"specificity":0.88},"tp":18.0,"fp":6.0,"fn":3.0,"tn":45.0,"sample_size":72.0,"observed_prevalence":0.2916666666666667,"sensitivity":0.8571428571428571,"specificity":0.8823529411764706,"ppv_observed":0.75,"npv_observed":0.9375,"youden_j":0.7394957983193278,"lr_positive":7.285714285714284,"lr_negative":0.16190476190476197,"diagnostic_odds_ratio":45.0,"baseline_entropy_bits_observed":0.8708644692353646,"conditional_entropy_bits_observed":0.49528608589772016,"information_bits_observed":0.3755783833376445,"information_fraction_observed":0.4312707621053932,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"44e06c609259"},{"id":"diagnostics-2024:583:ceccdbb2f213","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Unenhanced CT","test_or_feature":"Unenhanced CT","target_condition":"Choledocholithiasis","citation":"Anderson SW et al. Accuracy of MDCT in Diagnosis of Choledocholithiasis. American Journal of Roentgenology. 2006;187: 174-180. doi: 10.2214/AJR.05.0459","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"583","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":583,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2006,"source_reported":{"sensitivity":0.86,"specificity":0.92},"tp":18.0,"fp":4.0,"fn":3.0,"tn":47.0,"sample_size":72.0,"observed_prevalence":0.2916666666666667,"sensitivity":0.8571428571428571,"specificity":0.9215686274509803,"ppv_observed":0.8181818181818182,"npv_observed":0.94,"youden_j":0.7787114845938374,"lr_positive":10.92857142857142,"lr_negative":0.1550151975683891,"diagnostic_odds_ratio":70.5,"baseline_entropy_bits_observed":0.8708644692353646,"conditional_entropy_bits_observed":0.43640404919142683,"information_bits_observed":0.4344604200439378,"information_fraction_observed":0.4988840805796133,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f0f0705a2d36"},{"id":"diagnostics-2024:584:ce68cfe1bde3","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Assessment of calculation capability","test_or_feature":"Assessment of calculation capability","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043688","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"584","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":584,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.17,"specificity":0.95},"tp":8.0,"fp":1.0,"fn":38.0,"tn":18.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.17391304347826086,"specificity":0.9473684210526315,"ppv_observed":0.8888888888888888,"npv_observed":0.32142857142857145,"youden_j":0.12128146453089239,"lr_positive":3.304347826086953,"lr_negative":0.8719806763285025,"diagnostic_odds_ratio":3.789473684210526,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.8501739247905964,"information_bits_observed":0.021509692329385488,"information_fraction_observed":0.02467603142577453,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6132f0a640d9"},{"id":"diagnostics-2024:585:c0884a485707","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Assessment of naming capability","test_or_feature":"Assessment of naming capability","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043687","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"585","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":585,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.2,"specificity":1.0},"tp":9.0,"fp":0.0,"fn":35.0,"tn":17.0,"sample_size":61.0,"observed_prevalence":0.7213114754098361,"sensitivity":0.20454545454545456,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.3269230769230769,"youden_j":0.20454545454545459,"lr_positive":null,"lr_negative":0.7954545454545454,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8536576732793313,"conditional_entropy_bits_observed":0.7772310073607737,"information_bits_observed":0.07642666591855762,"information_fraction_observed":0.08952847061628827,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"599c4e1a1f08"},{"id":"diagnostics-2024:586:c235ce102596","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Assessment of construction capability","test_or_feature":"Assessment of construction capability","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043686","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"586","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":586,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.3,"specificity":0.89},"tp":14.0,"fp":2.0,"fn":32.0,"tn":17.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.30434782608695654,"specificity":0.8947368421052632,"ppv_observed":0.875,"npv_observed":0.3469387755102041,"youden_j":0.19908466819221982,"lr_positive":2.8913043478260874,"lr_negative":0.7774936061381074,"diagnostic_odds_ratio":3.71875,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.8358606946397382,"information_bits_observed":0.03582292248024366,"information_fraction_observed":0.04109624383971054,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4de89c07d4c5"},{"id":"diagnostics-2024:587:8b70a1c3d1da","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Visual field defect","test_or_feature":"Visual field defect","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043685","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"587","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":587,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.22,"specificity":0.95},"tp":10.0,"fp":1.0,"fn":36.0,"tn":18.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.21739130434782608,"specificity":0.9473684210526315,"ppv_observed":0.9090909090909091,"npv_observed":0.3333333333333333,"youden_j":0.16475972540045758,"lr_positive":4.130434782608692,"lr_negative":0.8260869565217392,"diagnostic_odds_ratio":5.0,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.8372683368473706,"information_bits_observed":0.034415280272611315,"information_fraction_observed":0.03948138934435688,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a13097930939"},{"id":"diagnostics-2024:588:f89d7d64d106","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Two point discrimination","test_or_feature":"Two point discrimination","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043684","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"588","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":588,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.2,"specificity":0.95},"tp":9.0,"fp":1.0,"fn":37.0,"tn":18.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.1956521739130435,"specificity":0.9473684210526315,"ppv_observed":0.9,"npv_observed":0.32727272727272727,"youden_j":0.1430205949656751,"lr_positive":3.7173913043478226,"lr_negative":0.8490338164251209,"diagnostic_odds_ratio":4.378378378378378,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.8439433173156358,"information_bits_observed":0.027740299804346114,"information_fraction_observed":0.031823816875209014,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"775fb0750730"},{"id":"diagnostics-2024:589:63de31b42721","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Impaired one-footed balance","test_or_feature":"Impaired one-footed balance","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043683","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"589","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":589,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.2,"specificity":0.74},"tp":9.0,"fp":5.0,"fn":37.0,"tn":14.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.1956521739130435,"specificity":0.7368421052631579,"ppv_observed":0.6428571428571429,"npv_observed":0.27450980392156865,"youden_j":-0.06750572082379869,"lr_positive":0.7434782608695651,"lr_negative":1.0916149068322982,"diagnostic_odds_ratio":0.6810810810810811,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.8677684988439618,"information_bits_observed":0.003915118276020091,"information_fraction_observed":0.004491444142262913,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0c05436d7d9f"},{"id":"diagnostics-2024:590:82aac5e31092","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"UMN weakness in lower limbs","test_or_feature":"UMN weakness in lower limbs","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043682","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"590","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":590,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.2,"specificity":1.0},"tp":9.0,"fp":0.0,"fn":37.0,"tn":19.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.1956521739130435,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.3392857142857143,"youden_j":0.19565217391304346,"lr_positive":null,"lr_negative":0.8043478260869565,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.7961765900234856,"information_bits_observed":0.07550702709649626,"information_fraction_observed":0.0866220560000535,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e8cd1be20bda"},{"id":"diagnostics-2024:591:0c32a51cd5a6","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid alternating movements","test_or_feature":"Rapid alternating movements","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043681","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"591","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":591,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.3,"specificity":1.0},"tp":14.0,"fp":0.0,"fn":32.0,"tn":19.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.30434782608695654,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.37254901960784315,"youden_j":0.30434782608695654,"lr_positive":null,"lr_negative":0.6956521739130435,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.74743184130951,"information_bits_observed":0.12425177581047187,"information_fraction_observed":0.1425422864100581,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0dab5382c046"},{"id":"diagnostics-2024:592:873718ca62c4","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"UMN weakness in upper limbs","test_or_feature":"UMN weakness in upper limbs","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043680","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"592","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":592,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.3,"specificity":1.0},"tp":14.0,"fp":0.0,"fn":32.0,"tn":19.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.30434782608695654,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.37254901960784315,"youden_j":0.30434782608695654,"lr_positive":null,"lr_negative":0.6956521739130435,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.74743184130951,"information_bits_observed":0.12425177581047187,"information_fraction_observed":0.1425422864100581,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5e290cda4b69"},{"id":"diagnostics-2024:593:5929b9572d77","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Finger rolling","test_or_feature":"Finger rolling","target_condition":"Focal cerebral hemispheric lesions","citation":"Anderson NE, Mason DF, Fink JN, Bergin PS, Charleston AJ, Gamble GD. Detection of focal cerebral hemisphere lesions using the neurological examination. J Neurol Neurosurg Psychiatry. 2005;76(4):545-549. doi:10.1136/jnnp.2004.043679","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"593","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":593,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.33,"specificity":1.0},"tp":15.0,"fp":0.0,"fn":31.0,"tn":19.0,"sample_size":65.0,"observed_prevalence":0.7076923076923077,"sensitivity":0.32608695652173914,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.38,"youden_j":0.32608695652173925,"lr_positive":null,"lr_negative":0.6739130434782609,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.8716836171199819,"conditional_entropy_bits_observed":0.7369554017125381,"information_bits_observed":0.13472821540744373,"information_fraction_observed":0.1545609126538158,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"93d51c82c77a"},{"id":"diagnostics-2024:594:0fb7170e7c85","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PSA","test_or_feature":"PSA","target_condition":"Prostate cancer","citation":"Aminsharifi A., Howard L., Wu Y., De Hoedt A., Bailey C., Freedland S.J., Polascik T.J. Prostate Specific Antigen Density as a Predictor of Clinically Significant Prostate Cancer When the Prostate Specific Antigen is in the Diagnostic Gray Zone: Defining the Optimum Cutoff Point Stratified by Race and Body Mass Index. J. Urol. 2018;200:758–766. doi: 10.1016/j.juro.2018.05.016.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"594","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":594,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.98,"specificity":0.16},"tp":489.0,"fp":1400.0,"fn":10.0,"tn":263.0,"sample_size":2162.0,"observed_prevalence":0.23080481036077705,"sensitivity":0.9799599198396793,"specificity":0.1581479254359591,"ppv_observed":0.25886712546320806,"npv_observed":0.9633699633699634,"youden_j":0.13810784527563835,"lr_positive":1.1640523904952762,"lr_negative":0.12671731295290214,"diagnostic_odds_ratio":9.186214285714286,"baseline_entropy_bits_observed":0.7794116326745109,"conditional_entropy_bits_observed":0.7494695813085561,"information_bits_observed":0.029942051365954736,"information_fraction_observed":0.038416223354545184,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3420fbba7367"},{"id":"diagnostics-2024:595:3c4e85b34db1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ascitic fluid examination","test_or_feature":"Ascitic fluid examination","target_condition":"Spontaneous bacterial peritonitis","citation":"Aminiahidashti H, Hosseininejad SM, Montazer H, et al. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis. Emerg (Tehran). 2014;2(3):138-140.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"595","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":595,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.47,"specificity":0.88},"tp":15.0,"fp":6.0,"fn":17.0,"tn":42.0,"sample_size":80.0,"observed_prevalence":0.4,"sensitivity":0.46875,"specificity":0.875,"ppv_observed":0.7142857142857143,"npv_observed":0.711864406779661,"youden_j":0.34375,"lr_positive":3.75,"lr_negative":0.6071428571428571,"diagnostic_odds_ratio":6.176470588235294,"baseline_entropy_bits_observed":0.9709505944546686,"conditional_entropy_bits_observed":0.8654658974285524,"information_bits_observed":0.10548469702611618,"information_fraction_observed":0.10864064312701857,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bf7dcb1ec623"},{"id":"diagnostics-2024:596:77cf317ba881","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Ulcerative colitis","citation":"Alshammari MT, Stevenson R, Abdul-Aema B, et al. Diagnostic Accuracy of Non-Invasive Imaging for Detection of Colonic Inflammation in Patients with Inflammatory Bowel Disease: A Systematic Review and Meta-Analysis. Diagnostics (Basel). 2021;11(10):1926. Published 2021 Oct 18. doi:10.3390/diagnostics11101929","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"596","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":596,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.93,"specificity":1.0},"tp":13.0,"fp":0.0,"fn":1.0,"tn":10.0,"sample_size":24.0,"observed_prevalence":0.5833333333333334,"sensitivity":0.9285714285714286,"specificity":1.0,"ppv_observed":1.0,"npv_observed":0.9090909090909091,"youden_j":0.9285714285714286,"lr_positive":null,"lr_negative":0.0714285714285714,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.9798687566511528,"conditional_entropy_bits_observed":0.20143611900569364,"information_bits_observed":0.7784326376454591,"information_fraction_observed":0.7944254088740093,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"300fc8668efd"},{"id":"diagnostics-2024:597:ac4706340170","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Ulcerative colitis","citation":"Alshammari MT, Stevenson R, Abdul-Aema B, et al. Diagnostic Accuracy of Non-Invasive Imaging for Detection of Colonic Inflammation in Patients with Inflammatory Bowel Disease: A Systematic Review and Meta-Analysis. Diagnostics (Basel). 2021;11(10):1926. Published 2021 Oct 18. doi:10.3390/diagnostics11101928","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"597","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":597,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.65,"specificity":0.93},"tp":20.0,"fp":2.0,"fn":11.0,"tn":27.0,"sample_size":60.0,"observed_prevalence":0.5166666666666667,"sensitivity":0.6451612903225806,"specificity":0.9310344827586207,"ppv_observed":0.9090909090909091,"npv_observed":0.7105263157894737,"youden_j":0.5761957730812013,"lr_positive":9.354838709677415,"lr_negative":0.3811230585424134,"diagnostic_odds_ratio":24.545454545454547,"baseline_entropy_bits_observed":0.9991983542636398,"conditional_entropy_bits_observed":0.7109078143284271,"information_bits_observed":0.2882905399352127,"information_fraction_observed":0.2885218322318682,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"699a42c9e8c6"},{"id":"diagnostics-2024:598:9024efbf5e32","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Abdominal US","test_or_feature":"Abdominal US","target_condition":"Crohn's disease","citation":"Alshammari MT, Stevenson R, Abdul-Aema B, et al. Diagnostic Accuracy of Non-Invasive Imaging for Detection of Colonic Inflammation in Patients with Inflammatory Bowel Disease: A Systematic Review and Meta-Analysis. Diagnostics (Basel). 2021;11(10):1926. Published 2021 Oct 18. doi:10.3390/diagnostics11101927","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"598","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":598,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.66,"specificity":0.91},"tp":223.0,"fp":28.0,"fn":113.0,"tn":272.0,"sample_size":636.0,"observed_prevalence":0.5283018867924528,"sensitivity":0.6636904761904762,"specificity":0.9066666666666666,"ppv_observed":0.8884462151394422,"npv_observed":0.7064935064935065,"youden_j":0.5703571428571428,"lr_positive":7.110969387755098,"lr_negative":0.37092962184873957,"diagnostic_odds_ratio":19.170670037926676,"baseline_entropy_bits_observed":0.9976875760352552,"conditional_entropy_bits_observed":0.7277293013647262,"information_bits_observed":0.2699582746705289,"information_fraction_observed":0.2705839795493148,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"ffc58a6a28b5"},{"id":"diagnostics-2024:599:32f60f09dac9","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Crohn's disease","citation":"Alshammari MT, Stevenson R, Abdul-Aema B, et al. Diagnostic Accuracy of Non-Invasive Imaging for Detection of Colonic Inflammation in Patients with Inflammatory Bowel Disease: A Systematic Review and Meta-Analysis. Diagnostics (Basel). 2021;11(10):1926. Published 2021 Oct 18. doi:10.3390/diagnostics11101926","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"599","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":599,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2021,"source_reported":{"sensitivity":0.74,"specificity":0.91},"tp":647.0,"fp":114.0,"fn":229.0,"tn":1126.0,"sample_size":2116.0,"observed_prevalence":0.41398865784499056,"sensitivity":0.7385844748858448,"specificity":0.9080645161290323,"ppv_observed":0.8501971090670171,"npv_observed":0.8309963099630996,"youden_j":0.6466489910148772,"lr_positive":8.033725867179365,"lr_negative":0.28788210580954926,"diagnostic_odds_ratio":27.90630506396997,"baseline_entropy_bits_observed":0.9785474817025501,"conditional_entropy_bits_observed":0.6388505621137043,"information_bits_observed":0.33969691958884585,"information_fraction_observed":0.3471440333153949,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"5c238bb7f185"},{"id":"diagnostics-2024:600:874b71cf2e82","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Rapid PCR test","test_or_feature":"Rapid PCR test","target_condition":"CNS Toxoplasmosis","citation":"Alfonso Y, Fraga J, Fonseca C, et al. Molecular diagnosis of Toxoplasma gondii infection in cerebrospinal fluid from AIDS patients. Cerebrospinal Fluid Res. 2009;6:2. Published 2009 Mar 6. doi:10.1186/1743-8454-6-2","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"600","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":600,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2009,"source_reported":{"sensitivity":0.83,"specificity":0.96},"tp":40.0,"fp":6.0,"fn":8.0,"tn":136.0,"sample_size":190.0,"observed_prevalence":0.25263157894736843,"sensitivity":0.8333333333333334,"specificity":0.9577464788732394,"ppv_observed":0.8695652173913043,"npv_observed":0.9444444444444444,"youden_j":0.7910798122065728,"lr_positive":19.722222222222197,"lr_negative":0.17401960784313722,"diagnostic_odds_ratio":113.33333333333333,"baseline_entropy_bits_observed":0.8154224977821039,"conditional_entropy_bits_observed":0.3698484472444631,"information_bits_observed":0.44557405053764076,"information_fraction_observed":0.5464333541808979,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"1bbe1308b1d5"},{"id":"diagnostics-2024:601:6787ea260d18","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Thyroid CT","test_or_feature":"Thyroid CT","target_condition":"Extrathyroidal extension of thyroid cancer","citation":"Alabousi M, Alabousi A, Adham S, et al. Diagnostic Test Accuracy of Ultrasonography vs Computed Tomography for Papillary Thyroid Cancer Cervical Lymph Node Metastasis: A Systematic Review and Meta-analysis. JAMA Otolaryngol Head Neck Surg. 2022;148(2):107–118. doi:10.1001/jamaoto.2021.3392","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"601","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":601,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.86,"specificity":0.3},"tp":150.0,"fp":142.0,"fn":24.0,"tn":61.0,"sample_size":377.0,"observed_prevalence":0.46153846153846156,"sensitivity":0.8620689655172413,"specificity":0.30049261083743845,"ppv_observed":0.5136986301369864,"npv_observed":0.7176470588235294,"youden_j":0.16256157635467972,"lr_positive":1.232394366197183,"lr_negative":0.45901639344262307,"diagnostic_odds_ratio":2.6848591549295775,"baseline_entropy_bits_observed":0.9957274520849255,"conditional_entropy_bits_observed":0.9677082987055142,"information_bits_observed":0.0280191533794113,"information_fraction_observed":0.028139380229743376,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"f9a18264000a"},{"id":"diagnostics-2024:602:a61e7ed5d766","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Thyroid US","test_or_feature":"Thyroid US","target_condition":"Extrathyroidal extension of thyroid cancer","citation":"Alabousi M, Alabousi A, Adham S, et al. Diagnostic Test Accuracy of Ultrasonography vs Computed Tomography for Papillary Thyroid Cancer Cervical Lymph Node Metastasis: A Systematic Review and Meta-analysis. JAMA Otolaryngol Head Neck Surg. 2022;148(2):107–118. doi:10.1001/jamaoto.2021.3391","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"602","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":602,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.91,"specificity":0.47},"tp":1293.0,"fp":770.0,"fn":128.0,"tn":683.0,"sample_size":2874.0,"observed_prevalence":0.4944328462073765,"sensitivity":0.9099225897255454,"specificity":0.4700619408121129,"ppv_observed":0.626757149781871,"npv_observed":0.842170160295931,"youden_j":0.37998453053765835,"lr_positive":1.7170357439885944,"lr_negative":0.19162880985180458,"diagnostic_odds_ratio":8.960217126623377,"baseline_entropy_bits_observed":0.9999105706763659,"conditional_entropy_bits_observed":0.861691101596692,"information_bits_observed":0.13821946907967386,"information_fraction_observed":0.13823183105883016,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a24328c4fe3c"},{"id":"diagnostics-2024:603:697ad73bd76c","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Thyroid CT","test_or_feature":"Thyroid CT","target_condition":"Central cervical metastasis of thyroid cancer","citation":"Alabousi M, Alabousi A, Adham S, et al. Diagnostic Test Accuracy of Ultrasonography vs Computed Tomography for Papillary Thyroid Cancer Cervical Lymph Node Metastasis: A Systematic Review and Meta-analysis. JAMA Otolaryngol Head Neck Surg. 2022;148(2):107–118. doi:10.1001/jamaoto.2021.3390","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"603","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":603,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.38,"specificity":0.89},"tp":1405.0,"fp":484.0,"fn":2293.0,"tn":3913.0,"sample_size":8095.0,"observed_prevalence":0.45682520074119826,"sensitivity":0.37993510005408326,"specificity":0.8899249488287468,"ppv_observed":0.7437797776601376,"npv_observed":0.6305188527231711,"youden_j":0.2698600488828302,"lr_positive":3.4516004854086852,"lr_negative":0.6967608906369016,"diagnostic_odds_ratio":4.953780460113966,"baseline_entropy_bits_observed":0.9946147462818706,"conditional_entropy_bits_observed":0.9201039495714941,"information_bits_observed":0.07451079671037653,"information_fraction_observed":0.07491422883977673,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a6b950824813"},{"id":"diagnostics-2024:604:75841ae52f21","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Thyroid US","test_or_feature":"Thyroid US","target_condition":"Central cervical metastasis of thyroid cancer","citation":"Alabousi M, Alabousi A, Adham S, et al. Diagnostic Test Accuracy of Ultrasonography vs Computed Tomography for Papillary Thyroid Cancer Cervical Lymph Node Metastasis: A Systematic Review and Meta-analysis. JAMA Otolaryngol Head Neck Surg. 2022;148(2):107–118. doi:10.1001/jamaoto.2021.3389","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"604","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":604,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.41,"specificity":0.89},"tp":2032.0,"fp":648.0,"fn":2923.0,"tn":5242.0,"sample_size":10845.0,"observed_prevalence":0.4568925772245274,"sensitivity":0.41009081735620584,"specificity":0.8899830220713073,"ppv_observed":0.7582089552238805,"npv_observed":0.6420085731781996,"youden_j":0.3000738394275131,"lr_positive":3.7275230157840316,"lr_negative":0.6628319507386393,"diagnostic_odds_ratio":5.623632070889455,"baseline_entropy_bits_observed":0.9946315619995711,"conditional_entropy_bits_observed":0.9056660242764942,"information_bits_observed":0.08896553772307692,"information_fraction_observed":0.0894457215335333,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"6b6d0e0381bd"},{"id":"diagnostics-2024:605:33920f151abc","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Thyroid CT","test_or_feature":"Thyroid CT","target_condition":"Lateral cervical metastasis of thyroid cancer","citation":"Alabousi M, Alabousi A, Adham S, et al. Diagnostic Test Accuracy of Ultrasonography vs Computed Tomography for Papillary Thyroid Cancer Cervical Lymph Node Metastasis: A Systematic Review and Meta-analysis. JAMA Otolaryngol Head Neck Surg. 2022;148(2):107–118. doi:10.1001/jamaoto.2021.3388","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"605","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":605,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.72,"specificity":0.9},"tp":496.0,"fp":116.0,"fn":193.0,"tn":1040.0,"sample_size":1845.0,"observed_prevalence":0.3734417344173442,"sensitivity":0.7198838896952104,"specificity":0.8996539792387543,"ppv_observed":0.8104575163398693,"npv_observed":0.8434712084347121,"youden_j":0.6195378689339648,"lr_positive":7.174015314548822,"lr_negative":0.31135983030032377,"diagnostic_odds_ratio":23.040914775772734,"baseline_entropy_bits_observed":0.9532781372816113,"conditional_entropy_bits_observed":0.6506767185190152,"information_bits_observed":0.30260141876259605,"information_fraction_observed":0.3174324543154854,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bd68478cc3bb"},{"id":"diagnostics-2024:606:60111e234dd1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Thyroid US","test_or_feature":"Thyroid US","target_condition":"Lateral cervical metastasis of thyroid cancer","citation":"Alabousi M, Alabousi A, Adham S, et al. Diagnostic Test Accuracy of Ultrasonography vs Computed Tomography for Papillary Thyroid Cancer Cervical Lymph Node Metastasis: A Systematic Review and Meta-analysis. JAMA Otolaryngol Head Neck Surg. 2022;148(2):107–118. doi:10.1001/jamaoto.2021.3387","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"606","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":606,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.82,"specificity":0.84},"tp":1020.0,"fp":307.0,"fn":224.0,"tn":1611.0,"sample_size":3162.0,"observed_prevalence":0.39342188488298546,"sensitivity":0.819935691318328,"specificity":0.8399374348279458,"ppv_observed":0.7686510926902789,"npv_observed":0.8779291553133515,"youden_j":0.6598731261462738,"lr_positive":5.12259497051646,"lr_negative":0.21437823963466598,"diagnostic_odds_ratio":23.89512563983248,"baseline_entropy_bits_observed":0.966972343798205,"conditional_entropy_bits_observed":0.6381335330803245,"information_bits_observed":0.32883881071788046,"information_fraction_observed":0.3400705437202297,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"fad5c9295eee"},{"id":"diagnostics-2024:607:bca07475b8c1","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Albumin-creatinine ratio","test_or_feature":"Albumin-creatinine ratio","target_condition":"Microalbuminuria","citation":"Al-Rubeaan K, Siddiqui K, Al-Ghonaim MA, Youssef AM, Al-Sharqawi AH, AlNaqeb D. Assessment of the diagnostic value of different biomarkers in relation to various stages of diabetic nephropathy in type 2 diabetic patients. Sci Rep. 2017;7(1):2684. Published 2017 Jun 2. doi:10.1038/s41598-017-02421-9","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"607","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":607,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.99,"specificity":0.95},"tp":183.0,"fp":13.0,"fn":1.0,"tn":270.0,"sample_size":467.0,"observed_prevalence":0.39400428265524623,"sensitivity":0.9945652173913043,"specificity":0.9540636042402827,"ppv_observed":0.9336734693877551,"npv_observed":0.996309963099631,"youden_j":0.948628821631587,"lr_positive":21.650919732441473,"lr_negative":0.005696457326892135,"diagnostic_odds_ratio":3800.769230769231,"baseline_entropy_bits_observed":0.9673350938083491,"conditional_entropy_bits_observed":0.1681510100812456,"information_bits_observed":0.7991840837271036,"information_fraction_observed":0.8261708779537362,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"97db208a48b4"},{"id":"diagnostics-2024:608:84653502d319","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Osteopontin","test_or_feature":"Osteopontin","target_condition":"Microalbuminuria","citation":"Al-Rubeaan K, Siddiqui K, Al-Ghonaim MA, Youssef AM, Al-Sharqawi AH, AlNaqeb D. Assessment of the diagnostic value of different biomarkers in relation to various stages of diabetic nephropathy in type 2 diabetic patients. Sci Rep. 2017;7(1):2684. Published 2017 Jun 2. doi:10.1038/s41598-017-02421-11","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"608","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":608,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.89,"specificity":0.55},"tp":163.0,"fp":128.0,"fn":21.0,"tn":155.0,"sample_size":467.0,"observed_prevalence":0.39400428265524623,"sensitivity":0.8858695652173914,"specificity":0.5477031802120141,"ppv_observed":0.5601374570446735,"npv_observed":0.8806818181818182,"youden_j":0.4335727454294056,"lr_positive":1.9586022418478262,"lr_negative":0.20838008415147255,"diagnostic_odds_ratio":9.399181547619047,"baseline_entropy_bits_observed":0.9673350938083491,"conditional_entropy_bits_observed":0.8153705606658427,"information_bits_observed":0.15196453314250646,"information_fraction_observed":0.15709606124619113,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"148ada4efb47"},{"id":"diagnostics-2024:609:0fdce708aac0","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transferrin-creatinine ratio","test_or_feature":"Transferrin-creatinine ratio","target_condition":"Microalbuminuria","citation":"Al-Rubeaan K, Siddiqui K, Al-Ghonaim MA, Youssef AM, Al-Sharqawi AH, AlNaqeb D. Assessment of the diagnostic value of different biomarkers in relation to various stages of diabetic nephropathy in type 2 diabetic patients. Sci Rep. 2017;7(1):2684. Published 2017 Jun 2. doi:10.1038/s41598-017-02421-10","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"609","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":609,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2017,"source_reported":{"sensitivity":0.7,"specificity":0.83},"tp":129.0,"fp":48.0,"fn":55.0,"tn":235.0,"sample_size":467.0,"observed_prevalence":0.39400428265524623,"sensitivity":0.7010869565217391,"specificity":0.8303886925795053,"ppv_observed":0.7288135593220338,"npv_observed":0.8103448275862069,"youden_j":0.5314756491012445,"lr_positive":4.133491847826088,"lr_negative":0.35996762257169285,"diagnostic_odds_ratio":11.482954545454545,"baseline_entropy_bits_observed":0.9673350938083491,"conditional_entropy_bits_observed":0.754725986719861,"information_bits_observed":0.21260910708848813,"information_fraction_observed":0.21978847707412005,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"61f535a06ee4"},{"id":"diagnostics-2024:610:7f521d9c6217","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Bishop score","test_or_feature":"Bishop score","target_condition":"Successful induction of labor","citation":"Al-Adwy AM, Sobh SM, Belal DS, et al. Diagnostic accuracy of posterior cervical angle and cervical length in the prediction of successful induction of labor. Int J Gynaecol Obstet. 2018;141(1):102-107. doi:10.1002/ijgo.12427","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"610","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":610,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.73,"specificity":0.81},"tp":36.0,"fp":4.0,"fn":13.0,"tn":17.0,"sample_size":70.0,"observed_prevalence":0.7,"sensitivity":0.7346938775510204,"specificity":0.8095238095238095,"ppv_observed":0.9,"npv_observed":0.5666666666666667,"youden_j":0.5442176870748301,"lr_positive":3.8571428571428577,"lr_negative":0.32773109243697474,"diagnostic_odds_ratio":11.76923076923077,"baseline_entropy_bits_observed":0.8812908992306927,"conditional_entropy_bits_observed":0.6910565282105261,"information_bits_observed":0.1902343710201666,"information_fraction_observed":0.21585877170208875,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"cf964e0c8a5a"},{"id":"diagnostics-2024:611:1497a75ec5c7","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Cervical length","test_or_feature":"Cervical length","target_condition":"Successful induction of labor","citation":"Al-Adwy AM, Sobh SM, Belal DS, et al. Diagnostic accuracy of posterior cervical angle and cervical length in the prediction of successful induction of labor. Int J Gynaecol Obstet. 2018;141(1):102-107. doi:10.1002/ijgo.12426","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"611","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":611,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.92,"specificity":0.81},"tp":45.0,"fp":4.0,"fn":4.0,"tn":17.0,"sample_size":70.0,"observed_prevalence":0.7,"sensitivity":0.9183673469387755,"specificity":0.8095238095238095,"ppv_observed":0.9183673469387755,"npv_observed":0.8095238095238095,"youden_j":0.7278911564625852,"lr_positive":4.821428571428572,"lr_negative":0.10084033613445376,"diagnostic_odds_ratio":47.8125,"baseline_entropy_bits_observed":0.8812908992306927,"conditional_entropy_bits_observed":0.49627415148440046,"information_bits_observed":0.38501674774629224,"information_fraction_observed":0.4368781614361226,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"47ce919bf79d"},{"id":"diagnostics-2024:612:2ab9aea40175","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Posterior cervical angle","test_or_feature":"Posterior cervical angle","target_condition":"Successful induction of labor","citation":"Al-Adwy AM, Sobh SM, Belal DS, et al. Diagnostic accuracy of posterior cervical angle and cervical length in the prediction of successful induction of labor. Int J Gynaecol Obstet. 2018;141(1):102-107. doi:10.1002/ijgo.12425","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"612","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":612,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":0.92,"specificity":0.9},"tp":45.0,"fp":2.0,"fn":4.0,"tn":19.0,"sample_size":70.0,"observed_prevalence":0.7,"sensitivity":0.9183673469387755,"specificity":0.9047619047619048,"ppv_observed":0.9574468085106383,"npv_observed":0.8260869565217391,"youden_j":0.8231292517006803,"lr_positive":9.642857142857144,"lr_negative":0.09022556390977442,"diagnostic_odds_ratio":106.875,"baseline_entropy_bits_observed":0.8812908992306927,"conditional_entropy_bits_observed":0.3894798418270965,"information_bits_observed":0.4918110574035962,"information_fraction_observed":0.5580575696775196,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"0843dcb9e201"},{"id":"diagnostics-2024:613:c932f49ae966","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Cardiac MRI","test_or_feature":"Cardiac MRI","target_condition":"Sarcoidosis","citation":"Aitken M, Chan MV, Urzua Fresno C, et al. Diagnostic Accuracy of Cardiac MRI versus FDG PET for Cardiac Sarcoidosis: A Systematic Review and Meta-Analysis. Radiology. 2022;304(3):566-579. doi:10.1148/radiol.213170","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"613","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":613,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.92,"specificity":0.72},"tp":632.0,"fp":143.0,"fn":55.0,"tn":367.0,"sample_size":1197.0,"observed_prevalence":0.5739348370927319,"sensitivity":0.9199417758369723,"specificity":0.7196078431372549,"ppv_observed":0.8154838709677419,"npv_observed":0.8696682464454977,"youden_j":0.6395496189742271,"lr_positive":3.2809112285094817,"lr_negative":0.11125257308758611,"diagnostic_odds_ratio":29.49065479974571,"baseline_entropy_bits_observed":0.9841694309150539,"conditional_entropy_bits_observed":0.643493919979213,"information_bits_observed":0.3406755109358409,"information_fraction_observed":0.3461553470717843,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"daeec892948b"},{"id":"diagnostics-2024:614:69a5fa209895","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"FDG PET scan","test_or_feature":"FDG PET scan","target_condition":"Sarcoidosis","citation":"Aitken M, Chan MV, Urzua Fresno C, et al. Diagnostic Accuracy of Cardiac MRI versus FDG PET for Cardiac Sarcoidosis: A Systematic Review and Meta-Analysis. Radiology. 2022;304(3):566-579. doi:10.1148/radiol.213170","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"614","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":614,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.81,"specificity":0.82},"tp":556.0,"fp":92.0,"fn":131.0,"tn":418.0,"sample_size":1197.0,"observed_prevalence":0.5739348370927319,"sensitivity":0.8093158660844251,"specificity":0.8196078431372549,"ppv_observed":0.8580246913580247,"npv_observed":0.761384335154827,"youden_j":0.62892370922168,"lr_positive":4.486424909815834,"lr_negative":0.23265289066254358,"diagnostic_odds_ratio":19.28377032857617,"baseline_entropy_bits_observed":0.9841694309150539,"conditional_entropy_bits_observed":0.6826507595491733,"information_bits_observed":0.3015186713658806,"information_fraction_observed":0.3063686616292652,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"3cdc52790724"},{"id":"diagnostics-2024:615:9e8d64664d22","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ultrasonography","test_or_feature":"Ultrasonography","target_condition":"Peritonsillar abscess","citation":"Ahmed K, Jones AS, Shah K, Smethurst A. The role of ultrasound in the management of peritonsillar abscess. J Laryngol Otol. 1994;108(7):610-612. doi:10.1017/s0022215100127598","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"615","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":615,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":1994,"source_reported":{"sensitivity":0.88,"specificity":0.82},"tp":14.0,"fp":2.0,"fn":2.0,"tn":9.0,"sample_size":27.0,"observed_prevalence":0.5925925925925926,"sensitivity":0.875,"specificity":0.8181818181818182,"ppv_observed":0.875,"npv_observed":0.8181818181818182,"youden_j":0.6931818181818183,"lr_positive":4.812500000000002,"lr_negative":0.15277777777777776,"diagnostic_odds_ratio":31.5,"baseline_entropy_bits_observed":0.9751190649408661,"conditional_entropy_bits_observed":0.6007945882675185,"information_bits_observed":0.37432447667334756,"information_fraction_observed":0.383875662092657,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"910a81f3fceb"},{"id":"diagnostics-2024:616:f1e7b1aef838","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MRI","test_or_feature":"MRI","target_condition":"Acoustic neuroma","citation":"Ahmad, T., Kanwal, N., Ameer, S., & Nasir, S. Diagnostic accuracy of magnetic resonance imaging in detection of acoustic neuroma. Biomedica. 2014;30(1).","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"616","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":616,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2014,"source_reported":{"sensitivity":0.98,"specificity":0.92},"tp":42.0,"fp":1.0,"fn":1.0,"tn":11.0,"sample_size":55.0,"observed_prevalence":0.7818181818181819,"sensitivity":0.9767441860465116,"specificity":0.9166666666666666,"ppv_observed":0.9767441860465116,"npv_observed":0.9166666666666666,"youden_j":0.8934108527131781,"lr_positive":11.720930232558134,"lr_negative":0.025369978858350996,"diagnostic_odds_ratio":462.0,"baseline_entropy_bits_observed":0.7568336324184035,"conditional_entropy_bits_observed":0.21487008907501626,"information_bits_observed":0.5419635433433873,"information_fraction_observed":0.7160933660038132,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bafb447a4379"},{"id":"diagnostics-2024:617:e88e2cdb64ec","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Ag/Ab combo assay","test_or_feature":"Ag/Ab combo assay","target_condition":"Neonatal HIV","citation":"Adhikari EH, Macias D, Gaffney D, et al. Diagnostic accuracy of fourth-generation ARCHITECT HIV Ag/Ab Combo assay and utility of signal-to-cutoff ratio to predict false-positive HIV tests in pregnancy. Am J Obstet Gynecol 2018;219:408.e1-9.","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"617","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":617,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2018,"source_reported":{"sensitivity":1.0,"specificity":0.97},"tp":157.0,"fp":1.0,"fn":0.0,"tn":32.0,"sample_size":190.0,"observed_prevalence":0.8263157894736842,"sensitivity":1.0,"specificity":0.9696969696969697,"ppv_observed":0.9936708860759493,"npv_observed":1.0,"youden_j":0.9696969696969697,"lr_positive":33.00000000000003,"lr_negative":0.0,"diagnostic_odds_ratio":null,"baseline_entropy_bits_observed":0.6660636950950825,"conditional_entropy_bits_observed":0.046010003347351905,"information_bits_observed":0.6200536917477305,"information_fraction_observed":0.9309225173415526,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"a0cbb4d09a72"},{"id":"diagnostics-2024:618:6f37b9736f53","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Unsaturated iron-bonding capacity","test_or_feature":"Unsaturated iron-bonding capacity","target_condition":"Hemochromatosis","citation":"Adams PC, Reboussin DM, Leiendecker-Foster C, et al. Comparison of the unsaturated iron-binding capacity with transferrin saturation as a screening test to detect C282Y homozygotes for hemochromatosis in 101,168 participants in the hemochromatosis and iron overload screening (HEIRS) study. Clin Chem. 2005;51(6):1048-1052. doi:10.1373/clinchem.2005.048372","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"618","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":618,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.79,"specificity":0.91},"tp":229.0,"fp":10904.0,"fn":61.0,"tn":114430.0,"sample_size":125624.0,"observed_prevalence":0.0023084760873718396,"sensitivity":0.7896551724137931,"specificity":0.9130004627634959,"ppv_observed":0.020569478128087668,"npv_observed":0.9994672070293735,"youden_j":0.702655635177289,"lr_positive":9.076544513876586,"lr_negative":0.23038852242147737,"diagnostic_odds_ratio":39.396687033183795,"baseline_entropy_bits_observed":0.023546160701053146,"conditional_entropy_bits_observed":0.018797574401604508,"information_bits_observed":0.004748586299448639,"information_fraction_observed":0.20167136204231584,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"bf0005e1c15e"},{"id":"diagnostics-2024:619:d86cd7c5274f","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Transferrin saturation","test_or_feature":"Transferrin saturation","target_condition":"Hemochromatosis","citation":"Adams PC, Reboussin DM, Leiendecker-Foster C, et al. Comparison of the unsaturated iron-binding capacity with transferrin saturation as a screening test to detect C282Y homozygotes for hemochromatosis in 101,168 participants in the hemochromatosis and iron overload screening (HEIRS) study. Clin Chem. 2005;51(6):1048-1052. doi:10.1373/clinchem.2005.048371","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"619","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":619,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2005,"source_reported":{"sensitivity":0.85,"specificity":0.94},"tp":154.0,"fp":4514.0,"fn":28.0,"tn":69490.0,"sample_size":74186.0,"observed_prevalence":0.002453293074164937,"sensitivity":0.8461538461538461,"specificity":0.9390032971190746,"ppv_observed":0.03299057412167952,"npv_observed":0.9995972266175667,"youden_j":0.7851571432729207,"lr_positive":13.872124331140714,"lr_negative":0.1638398441391678,"diagnostic_odds_ratio":84.66880815241471,"baseline_entropy_bits_observed":0.02480767162039333,"conditional_entropy_bits_observed":0.017962835685972803,"information_bits_observed":0.006844835934420528,"information_fraction_observed":0.2759160972121898,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"85f001d7e5d7"},{"id":"diagnostics-2024:620:3730e4dced2e","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MDCT arthrography","test_or_feature":"MDCT arthrography","target_condition":"Anterior shoulder instability","citation":"Acid S, Le Corroller T, Aswad R, Pauly V, Champsaur P. Preoperative imaging of anterior shoulder instability: diagnostic effectiveness of MDCT arthrography and comparison with MR arthrography and arthroscopy. AJR Am J Roentgenol. 2012;198(3):661-667. doi:10.2214/AJR.11.7251","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"620","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":620,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.83,"specificity":0.93},"tp":69.0,"fp":6.0,"fn":14.0,"tn":75.0,"sample_size":164.0,"observed_prevalence":0.5060975609756098,"sensitivity":0.8313253012048193,"specificity":0.9259259259259259,"ppv_observed":0.92,"npv_observed":0.8426966292134831,"youden_j":0.7572512271307452,"lr_positive":11.22289156626506,"lr_negative":0.18216867469879516,"diagnostic_odds_ratio":61.607142857142854,"baseline_entropy_bits_observed":0.9998927178165633,"conditional_entropy_bits_observed":0.524630145885258,"information_bits_observed":0.4752625719313053,"information_fraction_observed":0.4753135646083335,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"296859c93fcf"},{"id":"diagnostics-2024:621:21e0fbc005c2","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"MR arthrography","test_or_feature":"MR arthrography","target_condition":"Anterior shoulder instability","citation":"Acid S, Le Corroller T, Aswad R, Pauly V, Champsaur P. Preoperative imaging of anterior shoulder instability: diagnostic effectiveness of MDCT arthrography and comparison with MR arthrography and arthroscopy. AJR Am J Roentgenol. 2012;198(3):661-667. doi:10.2214/AJR.11.7251","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"621","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":621,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.76,"specificity":0.94},"tp":65.0,"fp":7.0,"fn":20.0,"tn":110.0,"sample_size":202.0,"observed_prevalence":0.4207920792079208,"sensitivity":0.7647058823529411,"specificity":0.9401709401709402,"ppv_observed":0.9027777777777778,"npv_observed":0.8461538461538461,"youden_j":0.7048768225238813,"lr_positive":12.781512605042014,"lr_negative":0.2502673796791444,"diagnostic_odds_ratio":51.07142857142857,"baseline_entropy_bits_observed":0.9818208799648493,"conditional_entropy_bits_observed":0.5626182827268961,"information_bits_observed":0.4192025972379533,"information_fraction_observed":0.4269644349516801,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"9946af109d52"},{"id":"diagnostics-2024:622:925f3492efeb","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"PremaQuick test","test_or_feature":"PremaQuick test","target_condition":"Risk of preterm labor","citation":"Abdelazim IA, Amer OO, Shikanova S, Karimova B. Diagnostic accuracy of PremaQuick in detection of preterm labor in symptomatic women. Ginekologia Polska. 2022;93(2):121-125. doi:10.5603/gp.a2021.0085","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"622","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":622,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2022,"source_reported":{"sensitivity":0.95,"specificity":0.98},"tp":116.0,"fp":3.0,"fn":6.0,"tn":119.0,"sample_size":244.0,"observed_prevalence":0.5,"sensitivity":0.9508196721311475,"specificity":0.9754098360655737,"ppv_observed":0.9747899159663865,"npv_observed":0.952,"youden_j":0.9262295081967213,"lr_positive":38.66666666666662,"lr_negative":0.05042016806722695,"diagnostic_odds_ratio":766.8888888888889,"baseline_entropy_bits_observed":1.0,"conditional_entropy_bits_observed":0.22513351492406608,"information_bits_observed":0.7748664850759339,"information_fraction_observed":0.7748664850759339,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"4ee3b5c39ac4"},{"id":"diagnostics-2024:623:ce24239dd5e8","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Lung CT","test_or_feature":"Lung CT","target_condition":"Idiopathic pulmonary fibrosis","citation":"Aaløkken TM, Naalsund A, Mynarek G, et al. Diagnostic accuracy of computed tomography and histopathology in the diagnosis of usual interstitial pneumonia. Acta Radiologica. 2012;53(3):296-302. doi:10.1258/ar.2011.110482","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"623","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":623,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.63,"specificity":0.96},"tp":26.0,"fp":2.0,"fn":15.0,"tn":48.0,"sample_size":91.0,"observed_prevalence":0.45054945054945056,"sensitivity":0.6341463414634146,"specificity":0.96,"ppv_observed":0.9285714285714286,"npv_observed":0.7619047619047619,"youden_j":0.5941463414634147,"lr_positive":15.853658536585352,"lr_negative":0.38109756097560976,"diagnostic_odds_ratio":41.6,"baseline_entropy_bits_observed":0.9929326437363042,"conditional_entropy_bits_observed":0.662434959974681,"information_bits_observed":0.33049768376162314,"information_fraction_observed":0.33285005367332277,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"db9be9de2197"},{"id":"diagnostics-2024:624:ec1072a42255","collection_id":"medical-diagnostics-2024","evidence_level":"diagnostic_tool","label":"Histological diagnosis","test_or_feature":"Histological diagnosis","target_condition":"Idiopathic pulmonary fibrosis","citation":"Aaløkken TM, Naalsund A, Mynarek G, et al. Diagnostic accuracy of computed tomography and histopathology in the diagnosis of usual interstitial pneumonia. Acta Radiologica. 2012;53(3):296-302. doi:10.1258/ar.2011.110482","source_url":"https://data.mendeley.com/datasets/hgwdb4mtpw/2","source_record_id":"624","source_file":"Entropy removal of medical diagnostics - data (2).csv","source_row":624,"category":"Medical diagnostic tool","quality_status":"source 2 x 2 table","source_year":2012,"source_reported":{"sensitivity":0.73,"specificity":0.74},"tp":30.0,"fp":13.0,"fn":11.0,"tn":37.0,"sample_size":91.0,"observed_prevalence":0.45054945054945056,"sensitivity":0.7317073170731707,"specificity":0.74,"ppv_observed":0.6976744186046512,"npv_observed":0.7708333333333334,"youden_j":0.4717073170731707,"lr_positive":2.8142589118198873,"lr_negative":0.3625576796308504,"diagnostic_odds_ratio":7.7622377622377625,"baseline_entropy_bits_observed":0.9929326437363042,"conditional_entropy_bits_observed":0.827380526916863,"information_bits_observed":0.16555211681944115,"information_fraction_observed":0.16673046038297767,"import_status":"included","import_notes":"Rates and information metrics recomputed from source counts.","provenance_hash":"e42c7ad18be5"}]}
